220W AC-DC Single Output Desktop
Features :
Universal AC input / Full range 3 pole AC inlet IEC320-C14
GS220
series
Built-in active PFC function, PF>0.91 Protections: Short circuit / Overload / Over voltage / Over temperature Fully enclosed plastic case Approvals: UL / CUL / TUV / BSMI / CCC / CB / FCC / CE Class power ( with earth pin) LED indicator for power on No load power consumption0.98 / 115VAC at full load 90% 2A / 230VAC 92% 93.5% 94.5%
47 ~ 63Hz PF>0.91 / 230VAC 90% 4A / 115VAC 120A / 230VAC 1.5mA / 240VAC 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover 95 5 (TSW1) detect on heatsink of power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +60 (Refer to output load derating curve) 20% ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03% / (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943 approved
I/P-O/P: 3KVAC SAFETY & I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH ISOLATION RESISTANCE EMC EMI CONDUCTION & RADIATION Compliance to EN55022 class B, FCC PART 15 class B / CISPR22 class B, CNS13438 class B, GB9254 class B (Note. 6) HARMONIC CURRENT Compliance to EN61000-3-2,3, GB17625.1 EMS IMMUNITY OTHERS MTBF DIMENSION PACKING PLUG CABLE Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A 191.3Khrs min. MIL-HDBK-217F(25 ) 210*85*46mm (L*W*H) 1.1Kg; 12pcs/14.2Kg/0.73CUFT See page 2 ; Other type available by customer requested See page 2 ; Other type available by customer requested
CONNECTOR NOTE
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4. Tolerance: includes set up tolerance, line regulation, load regulation. 5. Line regulation is measured from low line to high line at rated load. 6. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. 7. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 8. Derating may be needed under low input voltage. Please check the derating curve for more details.
File Name:GS220-SPEC 2009-11-09
220W AC-DC Single Output Desktop
Mechanical Specification
46 210
GS220
Case No.961A
series
Unit:mm
DC OUTPUT INLET
85
UL1185 16AWGx4C 1000 50mm 30 3mm
Plug Assignment
Standard plug: R7B (option) R7B
PIN NO OUTPUT
4 3 1 2
1,4 2,3
+V -V
Derating Curve
230VAC
Static Characteristics
100 90
100
80
For others For 12~15V
80
60
LOAD (%)
LOAD (%)
10 20 30 40 50 60 70
50 40
100VAC for others 110VAC for 12~15V
70 60 50 40
20
-10
(HORIZONTAL)
90
95
100
110
120
140
160
180
200
220
240
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (VAC) 60Hz
File Name:GS220-SPEC 2009-11-09