90W AC-DC Single Output Desktop
Features :
Universal AC input / Full range
GS90
3 pole AC inlet IEC320-C14 Built-in active PFC function, PF>0.91
series
Protections: Short circuit / Overload / Over voltage / Over temperature Fully enclosed plastic case Approvals: UL / CUL / TUV / BSMI / CB / FCC / CE Class power ( with earth pin) Pass LPS LED indicator for power on No load power consumption0.91 / 230VAC 88% 2A / 115VAC 70A / 230VAC 1mA / 240VAC 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover RTH30 > 100 Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +50 (Refer to "Derating Curve") 20% ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03% / (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, BSMI CNS14336, J60950-1(except for 48V) approved I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB17625.1 Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A 348.7Khrs min. MIL-HDBK-217F(25 ) 145*60*32mm (L*W*H) 0.45Kg; 30pcs/14.05Kg/1CUFT Standard type P1M: 2.5 * 5.5 * 11mm, tuning fork type, center positive for stock ; Other type available by customer requested See page 2 ; Other type available by customer requested PF>0.95 / 115VAC at full load 89% 1A / 230VAC 89% 89.5% 91%
CONNECTOR NOTE
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4. Tolerance: includes set up tolerance, line regulation, load regulation. 5. Line regulation is measured from low line to high line at rated load. 6. Load regulation is measured from 10% to 100% rated load 7. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. 8. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 9. Derating may be needed under low input voltages. Pleas check the derating curve for more details.
File Name:GS90-SPEC 2011-06-15
90W AC-DC Single Output Desktop
Mechanical Specification
GS90
Case No. 978A
series
Unit:mm
32
145
UL1185 14AWG 1000 50mm for 12V ~ 15V UL1185 16AWG 1200 50mm for 19 ~ 48V
7 0 10mm
C"+"
60
11 0.5mm
POWER LED
ID 2.5 x OD 5.5
Plug Assignment
Standard plug: P1M P1M
P/N CENTER OUTPUT +
Derating Curve
Static Characteristics
Ta=25
100 90
100
80
80
60
70
LOAD (%)
LOAD (%)
0 10 20 30 40 50 60 70
50 40
60 50 40
20
-30
(HORIZONTAL)
90
95
100
110
120
140
160
180
200
220
240
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (VAC) 60Hz
File Name:GS90-SPEC 2011-06-15