SPECIFICATION
MODEL
DC VOLTAGE
OUTPUT
IRM-10-3.3
IRM-10-5
IRM-10-12
IRM-10-15
IRM-10-24
3.3V
5V
12V
15V
24V
RATED CURRENT
2.5A
2A
0.85A
0.67A
0.42A
CURRENT RANGE
0 ~ 2.5A
0 ~ 2A
0 ~ 0.85A
0 ~ 0.67A
0 ~ 0.42A
RATED POWER
8.25W
RIPPLE & NOISE (max.) Note.2 200mVp-p
10W
200mVp-p
10.2W
200mVp-p
10.05W
200mVp-p
10.08W
200mVp-p
VOLTAGE TOLERANCE Note.3 ±2.5%
±0.3%
LINE REGULATION
±2.5%
±0.3%
±2.5%
±0.3%
±2.5%
±0.3%
±2.5%
±0.3%
LOAD REGULATION
±0.5%
±0.5%
±0.5%
±0.5%
82%
82%
±0.5%
SETUP, RISE TIME
Note.4 600ms, 30ms at full load
HOLD UP TIME (Typ.)
30ms/230VAC
8ms/115VAC at full load
VOLTAGE RANGE
85 ~ 305VAC
120 ~ 430VDC
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
47 ~ 440Hz
74%
77%
0.25A/115VAC
0.15A/230VAC
82%
0.125A/277VAC
LEAKAGE CURRENT
COLD START 20A/115VAC
< 0.25mA/277VAC
OVERLOAD
115%~190% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
OVER VOLTAGE
WORKING TEMP.
3.8 ~ 4.95V
40A/230VAC
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
Protection type : Shut off o/p voltage, clamping by zener diode
-30 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
ENVIRONMENT
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
VIBRATION
SOLDERING TEMPERATURE Wave soldering: 265℃,5s (max.); Manual soldering: 390℃,3s (max.)
OPERATING ALTITUDE Note.5 2000 meters
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
SAFETY &
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Standard
Test Level / Note
Conducted
BS EN/EN55032(CISPR32), CNS13438
Class B
Radiated
BS EN/EN55032(CISPR32), CNS13438
Class B
Harmonic Current (Note 5)
BS EN/EN61000-3-2
Class A
Parameter
EMC
(Note.6)
IEC62368-1, UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, BSMI CNS14336-1 approved
I/P-O/P:3KVAC
EMC EMISSION
BS EN/EN61000-3-3
BS EN/EN55035, BS EN/EN61000-6-2
-------
Parameter
Standard
Test Level /Note
ESD
Level 3, 8KV air; Level 2, 4KV contact, criteria A
Radiated Susceptibility
BS EN/EN61000-4-2
BS EN/EN61000-4-3
EFT/Burest
BS EN/EN61000-4-4
Level 3, criteria A
Level 3, criteria A
Surge
BS EN/EN61000-4-5
Level 3,1KV/L-N, criteria A
Conducted
BS EN/EN61000-4-6
Level 3, criteria A
Magnetic Field
BS EN/EN61000-4-8
Voltage Dips and interruptions
BS EN/EN61000-4-11
Level 4, criteria A
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Voltage Flicker
EMC IMMUNITY
OTHERS
MTBF
9094.9K hrs min.
DIMENSION
45.7*25.4*21.5 mm (L*W*H)
0.033Kg;270pcs/ 9.8Kg/0.94CUFT
PACKING
NOTE
Telcordia SR-332 (Bellcore) ; 1495.8K hrs min.
MIL-HDBK-217F (25℃)
℃
℃℃
(as available on http://www.meanwell.com)
※:https://www.meanwell.com/serviceDisclaimer.aspx
File Name:IRM-10-SPEC 2022-04-25
IRM-10
10W AC-DC PCB-Mount Green Power Module
Block Diagram
series
fosc : 65KHz
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PWM
CONTROL
+V
-V
DETECTION
CIRCUIT
Derating Curve
Output Derating VS Input Voltage
100
100
90
80
80
70
50
LOAD (%)
LOAD (%)
60
40
20
-30
0
10
20
30
40
50
60
70
(HORIZONTAL)
60
50
40
85
95
100
115
120
140
160
Mechanical Specification
305
Unit:(mm)
3.5±1mm
-V
8
3.45
38.5
AC/L
240
21.5
10.75
AC/N
BOTTOM
VIEW
+V
1.04
3.45
220
Case No.222A
45.7
25.4
200
INPUT VOLTAGE (VAC) 60Hz
AMBIENT TEMPERATURE (℃)
3.6
180
P/N diameter:1.04
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
File Name:IRM-10-SPEC 2022-04-25