60W Single Output Switching Power Supply
Features :
L P V- 6 0
series
Constant voltage design Universal AC input / Full range Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage Cooling by free air convection Fully encapsulated with IP67 level (Note.8) Fully isolated plastic case Class power unit, no FG Class 2 power unit Pass LPS Suitable for LED lighting and moving sign applications (Note.7) 100% full load burn-in test Low cost, high reliability 2 years warranty
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT(max.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF OTHERS DIMENSION PACKING
NOTE
LPS IP67
LPV-60-5 5V 8A 0 ~ 8A 40W 8.0% 1.0% 6.0% 50ms/230VAC
Note.4 90 ~ 264VAC
( for 48V only)
( except for 5V,48V )
LPV-60-12 12V 5A 0 ~ 5A 60W 120mVp-p 5.0% 2.0%
LPV-60-15 15V 4A 0 ~ 4A 60W 120mVp-p
LPV-60-24 24V 2.5A 0 ~ 2.5A 60W 150mVp-p
LPV-60-36 36V 1.67A 0 ~ 1.67A 60W 150mVp-p
LPV-60-48 48V 1.25A 0 ~ 1.25A 60W 150mVp-p
RIPPLE & NOISE (max.) Note.2 80mVp-p
Note.6 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V)
16ms/115VAC at full load 127 ~ 370VDC 83% 83% 60A/230VAC 86% 86% 86%
47 ~ 63Hz 76% 1.2A/115VAC 1A/230VAC COLD START 30A/115VAC 0.25mA / 240VAC 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 -40 ~ +80 (Refer to "Derating Curve") , 10 ~ 95% RH 20 ~ 90% RH non-condensing 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48), CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), IP67 approved ; design refer to TUV EN60950-1 I/P-O/P:3KVAC I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A 732Khrs min. MIL-HDBK-217F (25 ) 162.5*42.5*32mm (L*W*H) 0.4Kg; 32pcs/13.8Kg/0.56CUFT 41.4 ~ 48.6V 55.2 ~ 64.8V
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit. 8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
File Name:LPV-60-SPEC 2012-03-20
60W Single Output Switching Power Supply
Mechanical Specification
L P V- 6 0
Case No. 976A
series
Unit:mm
600 30 UL1015 18AWG
162.5 3.5
600 30
42.5
AC/N(Blue) AC/L(Brown)
T case
81.5
3.5
3.6
15
UL1007 16AWG
3.5
3.6
3.5
+V(Red) -V(Black)
T case: Max. Case Temperature.
32
Recommend Mounting Direction
Block Diagram
fosc : 65KHz
I/P
EMI FILTER & RECTIFIERS
POWER SWITCHING
RECTIFIERS & FILTER
+V -V
O.L.P.
PWM CONTROL
DETECTION CIRCUIT
O.V.P.
Derating Curve
Static Characteristics
100
230VAC
100 90
80
80
60
115VAC
70
LOAD (%)
40
LOAD (%)
-15 0 15 30 40 50 60 70 (HORIZONTAL)
60 50 40
20
-30
90
100
125
135
145
155 165
175
180
200
230
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (V) 60Hz
File Name:LPV-60-SPEC 2012-03-20