100W DC-DC Non-Isolated Regulated Converter
NID100
series
■ Features :
Economical open frame design
Wide input range
High efficiency up to 97%
Remote ON / OFF control
Compact size 2.0"×1.082"× 0.472"(SIP package)
Protections: Short circuit / Overload / Over voltage
-30~+85℃ wide working temperature
Cooling by free air convection
Comply to BS EN/EN55032 ClassA without additional components
Trimming output (optional)
3 years warranty
■ GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
ORDER NO.
TPTC004
NID100-5
NID100-12
NID100-15
NID100-24
DC VOLTAGE
RATED CURRENT
5V
11A
12V
7.5A
15V
6.5A
24V
4. 2A
RATED POWER
55W
90W
97.5W
100.8W
120mVp-p
150mVp-p
200mVp-p
RIPPLE & NOISE (max.) Note.2 100mVp-p
OUTPUT
LINE REGULATION
Note.3 ±0.5%
±0.5%
±0.5%
±0.5%
LOAD REGULATION
Note.4 ±0.5%
±0.5%
±0.5%
±0.5%
±2.0%
±2.0%
±2.0%
±2.0%
VOLTAGE TOLERANCE
SWITCHING FREQUENCY (Typ.) 200KHz
EXTERNAL CAPACITANCE LOAD (max.) 100uF/16V low ESR
VOLTAGE RANGE
NORMAL VOLTAGE
INPUT
93% (12/24VDC)
24Vin
EFFICIENCY (Typ.)
48Vin
92%
Full load 5400mA/12VDC
DC CURRENT
No load 20mA
PROTECTION
OVERLOAD (Typ.)
PROTECTION OVER VOLTAGE
SHORT CIRCUIT
FUNCTION
ENVIRONMENT
10.5 ~ 53VDC
24VDC (or 48VDC)
REMOTE CONTROL
47uf/50V low ESR
20 ~ 53VDC
30 ~ 53VDC
24VDC (or 48VDC)
24VDC (or 48VDC)
96%
95%
97%
48VDC
------
95%
4500mA/24VDC
30mA
96%
2300mA/48VDC
4600mA/24VDC
30mA
50mA
Protection type : Hiccup mode, recovers automatically after fault condition is removed
15.6~ 18V
17.5~ 21V
6.4 ~ 7.5V
28~ 33V
Protection type : Shut off o/p voltage, clamp by TVS diode
All output equipped with short circuit
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Power on : 1.2VDC < R.C ~ com < 12VDC or open circuit ; power off : R.C ~ com < 0.4VDC or short circuit (PIN5,6,7,8 & PIN13)
SAFETY STANDARDS
EAC TP TC 004 approved
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP.
-30 ~ +85℃ (Refer to "Derating Curve")
20% ~ 85% RH non-condensing
-30 ~ +105℃
TEMP. COEFFICIENT
±0.03% / ℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARD
BS EN/EN62368-1(LVD)
EMC EMISSION
Conducted
Radiated
SAFETY &
EMC
Standard
BS EN/EN55032
Class A without external components,Class B with external components
Test Level / Note
BS EN/EN55032
Class A without external components,Class B with external components
BS EN/EN55035
Parameter
EMC IMMUNITY
Radiated
EFT / Burst
Surge
Conducted
MTBF
DIMENSION
WEIGHT
NOTE
47uf/50V low ESR
20 ~ 53VDC
Fuse recommended (8A)
120 ~ 300% rated output power
Parameter
OTHERS
68uf/25V low ESR
Standard
Test Level / Note
BS EN/EN61000-4-3
BS EN/EN61000-4-4
Level 2, 3V/m ; criteria A
BS EN/EN61000-4-5
BS EN/EN61000-4-6
17290.5K hrs min. Telcordia SR-332 (Bellcore) ; 1000.6K hrs min.
50.8*27.5*12mm or 2.0"*1.082"*0.472" inch (L*W*H)
35g;280psc/10.8Kg/0.94CUFT
Level 2, 1KV ; criteria A
Level 2, 1KV/Line-Line,criteria A
Level 2, 3V ; criteria A
MIL-HDBK-217F (25℃)
1.All parameters are specified at normal input, rated load, 25℃ 70% RH Ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100% rated load.
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
File Name:NID100-SPEC 2022-09-20
NID100
100W DC-DC Non-Isolated Regulated Converter
series
Connection diagram to obtain negative output voltage
Note:input voltage must be < 30VDC.
+ Vin
GND
NID100
+
+
6 5 4 3 2 1
13 12 11 10 9 8 7
- Vo
- Vin
Derating Curve
NID100-5V
NID100-12V,15V
100
90
80
70
60
50
40
30
20
-30
30<Vin≤50Vdc
50<Vin≤53Vdc
0 10 20 30 40 50
65
75
85
(VERTICAL)
LOAD (%)
LOAD (%)
20≤Vin≤30Vdc
10.5≤Vin≤30Vdc
30<Vin≤50Vdc
100
90
80
70
60
50
40
30
20
-30
50<Vin≤53Vdc
0 10 20 30 40 50
65
85
75
(VERTICAL)
AMBIENT TEMPERATURE (℃)
AMBIENT TEMPERATURE (℃)
NID100-24V
LOAD (%)
30≤Vin≤36Vdc
36<Vin≤50Vdc
100
90
80
70
60
50
40
30
20
-30
50<Vin≤53Vdc
0 10 20 30 40 50
65
75
85
(VERTICAL)
AMBIENT TEMPERATURE (℃)
File Name:NID100-SPEC 2022-09-20
100W DC-DC Non-Isolated Regulated Converter
NID100
Mechanical Specification
series
Unit:mm(inch)
12[0.472]max.
9 [0.315]
27 . 5 [1.082]
4.5[0.18]
50.8 [2]
1 2 3 4 5 6
SIDE
VIEW
7 8 9 1011 1213
1.3 [0.051]
0.64 [0.025]
25.4 [1]
10.2 [0.402]
4 [0.16]
2.54 [0.1]
Pin Configuration
Pin No.
Pin_Out
1,2,3,4
5,6,7,8
9,10
11
12
+ Vo u t
Com
+ Vi n
N.C.
Tr i m ( o p t i o n a l )
13
R.C.
EMC Suggestion Circuit
※Comply to EN55032 Class A without additional componenets ,required external components to meet Class B emisssion are as below:
L1
+Vin
+Vin
C1
+
C2
+
+V o
NID100
-Vin
GND
C1/C2
L1
C3
120μF/63V
15μH(NiZn)
22μF/35V
+V o
C3
+
Load
-V o
File Name:NID100-SPEC 2022-09-20