10W DC-DC Regulated Single Output
Features :
Wide 4:1 DC input range
NSD10-S
Protections: Short circuit / Overload / Over voltage 1000VDC I/O isolation Built-in EMI filter Cooling by free air convection Built-in remote ON-OFF control 100% full load burn-in test Low cost High reliability 2 years warranty
series
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT CAPACITIVE LOAD (max.) VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION RATED DC INPUT VOLTAGE RANGE EFFICIENCY (Typ.) DC CURRENT SHUTDOWN IDLE CURRENT OVERLOAD NSD10-12S3 NSD10-12S5 NSD10-12S9 NSD10-12S12 NSD10-12S15 NSD10-48S3 NSD10-48S5 NSD10-48S9 NSD10-48S12 NSD10-48S15 3.3V 2.5A 8.25W 3300uF 2.0% max. 1.0% 2.0% 1.0% 1.0% 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 1.0% 12VDC 9.8 ~ 36VDC 72% 75% 1.4A/12VDC 20mA/12VDC 48VDC 22 ~ 72VDC 74% 77% 0.4A/48VDC 5V 2A 10W 9V 1.1A 9.9W 12V 0.83A 9.96W 15V 0.67A 10.05W 3.3V 2.5A 8.25W 5V 2A 10W 9V 1.1A 9.9W 12V 0.83A 9.96W 15V 0.67A 10.05W
0.12 ~ 2.5A 0.1 ~ 2A
0.05 ~ 1.1A 0.04 ~ 0.83A 0.03 ~ 0.67A 0.12 ~ 2.5A 0.1 ~ 2A
0.05 ~ 1.1A 0.04 ~ 0.83A 0.03 ~ 0.67A
RIPPLE & NOISE (max.) Note.2 75mVp-p
INPUT
78%
79%
80%
78%
79%
80%
Above 105% rated output power Protection type : Over power limiting, recovers automatically after fault condition is removed PROTECTION 3.8 ~ 4.95V 5.75 ~ 7.5V 10.4 ~ 13.5V 13.8 ~ 18V 17.3 ~ 22.5V 3.8 ~ 4.95V 5.75 ~ 7.5V 10.4 ~ 13.5V 13.8 ~ 18V 17.3 ~ 22.5V OVER VOLTAGE(CLAMP) SHORT CIRCUIT Note.4 Recovers automatically after fault condition is removed Logic "1" OPEN: ON logic "0" GND: OFF FUNCTION ON/OFF CONTROL -25 ~ +70 WORKING TEMP. ENVIRONMENT WORKING HUMIDITY STORAGE TEMP., HUMIDITY 0% ~ 95% RH max. -40 ~ +85 , 0 ~ 95% RH 0.03%/ (0~60 UL60950-1 approved, Design refer to TUV EN60950-1 I/P-O/P:1KVDC I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-4-2,3,4,6,8; EN55024, light industry level, criteria A 2138.2K hrs min. MIL-HDBK-217F (25 50.8*25.4*10mm (2"*1"*0.394") (L*W*H) 0.02Kg; 300pcs/7Kg/0.97CUFT )
TEMP. COEFFICIENT SAFETY STANDARDS SAFETY & ISOLATION VOLTAGE ISOLATION RESISTANCE EMC (Note 5) EMI CONDUCTION & RADIATION EMS IMMUNITY MTBF OTHERS
NOTE
DIMENSION PACKING
1. All parameters NOT specially mentioned are measured at 12, 48VDC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Short circuit not more than 60 seconds. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 6. To insure proper operation, a 220uF/100V electrolytic capacitor with Esr