44~49W AC-DC Dual Output Desktop
Features :
3 pole AC inlet IEC320-C14 Class power (with earth pin)
P50A-D
series
Protections: Short circuit / Overload / Over voltage Fully enclosed plastic case Fix switching frequency and regulation Topology: PWM 3882 circuit LED indicator for power on Approvals: UL / CUL / TUV / CB / CE 1 year warranty
SPECIFICATION
ORDER NO. SAFETY MODEL NO. DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE P50A13-R1B PSU50A-13
Note.2 5V
TUV Rheinland Product Safety
geprUfre Sicherheit
P50A14-R1B PSU50A-14 12V 2A 0.1 ~ 2.0A 100mVp-p 10% 1.0% 9.0% 135 ~ 370VDC 74% 5V 4A 0.5 ~ 4.0A 47W 50mVp-p 6.0% 1.0% 5.0% 100mVp-p 10% 1.0% 9.0% 15V 1.8A 0.1 ~1.8A
P50A16-R1B PSU50A-16 5V 4A 0.5 ~ 4.0A 49W 50mVp-p 6.0% 1.0% 5.0% 100mVp-p 10% 1.0% 9.0% 24V 1A 0.1 ~ 1.0A
4A 0.5 ~ 4.0A 44W
RIPPLE & NOISE (max.) Note.3 50mVp-p Fixed VOLTAGE TOLERANCE Note.4 6.0% LINE REGULATION LOAD REGULATION VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (max.) LEAKAGE CURRENT(max.) OVERLOAD
Note.5 Note.6
1.0% 5.0% 90 ~ 264VAC 47 ~ 63Hz 70% 1.6A / 100VAC 40A / 230VAC 0.75mA / 240VAC
SETUP, RISE, HOLD UP TIME 1.5s, 50ms, 12ms at full load
INPUT
75%
150 ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5V: 110 ~ 140% of rated output voltage Protection type : Shut down o/p voltage, re-power on to recover 0 ~ +40 (Refer to output load derating curve) 20% ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03% / (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1950, CSA22.2, EN60950-1 approved
PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC (Note. 7)
I/P-O/P:3KVAC , I/P-FG:1.5KVAC I/P-O/P,I/P-FG:100M Ohms / 500VDC / 25 / 70% RH ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022(CISPR22) class B HARMONIC CURRENT EMS IMMUNITY MTBF Compliance to EN61000-3-2,3 Compliance to EN61000-4-2,3,4,5,6,11, ENV50204, light industry level, criteria A 280K hrs min. MIL-HDBK-217F (25 ) 147*76*43mm (L*W*H) 0.55kg; 36pcs / 21kg / CARTON Standard type R1B: DIN 5PIN for stock ; Other type available by customer requested Standard type AWM2464 18Awg*4c with shiell 4ft for stock ; Other type available by customer requested
DIMENSION PACKING PLUG CONNECTOR CABLE NOTE
OTHERS
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerence: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 20% to 100% rated load. 7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
File Name:P50A-D-SPEC 2007-05-14
44~49W AC-DC Dual Output Desktop
Mechanical Specification
P50A-D
series
Unit:mm
UL2464 18AWG 1220+100/-0
43
43
144.5
54.8 10.2
SWITCHING ADAPTOR
76
POWER LED 147
Plug Assignment
144.5 69.9 21.5
Standard plug: R1B (option)
PIN NO OUTPUT COM COM +5VDC - Vout +Vout
38
1
524 3 1 45
o
40
42
76
2 3 4 5
NAME PLATE
RUBBER FOOTX4
Derating Curve
Static Characteristics
100
100
LOAD (%)
LOAD (%)
80 60
60
0
10
20
30
40
0
50
60
70
80
90 100
260
Ta (
)
INPUT VOLTAGE
File Name:P50A-D-SPEC 2007-05-14
46.5~50W AC-DC Triple Output Desktop
Features :
3 pole AC inlet IEC320-C14
P50A-T
series
Class power (with earth pin) Protections: Short circuit / Overload / Over voltage Fully enclosed plastic case Fix switching frequency and regulation Topology: PWM 3882 circuit LED indicator for power on Approvals: UL / CUL / TUV / CB / CE 1 year warranty
SPECIFICATION
ORDER NO. SAFETY MODEL NO. DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE P50A13A-R1B PSU50A-13A
Note.2 5V
TUV Rheinland Product Safety
geprUfre Sicherheit
P50A13D-R1B PSU50A-13D -5V 0.5A 0.1 ~ 0.5A 100mVp-p 12% 1.0% 10% 5V 4A 0.5 ~ 4.0A 50W 50mVp-p 6.0% 1.0% 5.0% 12V 2A 0.5 ~2.0A 100mVp-p 10% 1.0% 10% -12V 0.5A 0.1 ~0.5A 100mVp-p 12% 1.0% 10%
P50A14E-R1B PSU50A-14E 5V 4A 0.5 ~ 4.0A 50W 50mVp-p 6.0% 1.0% 5.0% 100mVp-p 10% 1.0% 10% 100mVp-p 12% 1.0% 10% 15V 1.5A 0.5 ~ 1.5A -15V 0.5A 0.1 ~ 0.5A
12V 2A 0.5 ~ 2.0A 100mVp-p 10% 1.0% 10%
4A 0.5 ~ 4.0A 46.5W
RIPPLE & NOISE (max.) Note.3 50mVp-p Fixed VOLTAGE TOLERANCE Note.4 6.0% LINE REGULATION LOAD REGULATION VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (max.) LEAKAGE CURRENT (max.) OVERLOAD
Note.5 Note.6
1.0% 5.0% 90 ~ 264VAC 47 ~ 63Hz 70% 1.6A / 100VAC 40A / 230VAC
SETUP, RISE, HOLD UP TIME 1.5s, 50ms, 12ms at full load 135~ 370VAC 72% 74%
INPUT
0.75mA / 240VAC 150 ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5V: 110 ~ 140% of rated output voltage Protection type : Shut down o/p voltage, re-power on to recover 0 ~ +40 (Refer to output load derating curve) 20% ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03% / (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1950, CSA22.2, EN60950-1 approved I/P-O/P:3KVAC , I/P-FG:1.5KVAC I/P-O/P,I/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022(CISPR22) class B Compliance to EN61000-3-2,3 Compliance to EN61000-4-2,3,4,5,6,11, ENV50204, light industry level, criteria A 280K hrs min. MIL-HDBK-217F (25 ) 147*76*43mm (L*W*H) 0.55kg; 36pcs / 21kg / CARTON Standard type R1B: DIN 5PIN for stock ; Other type available by customer requested Standard type AWM2464 18Awg*4c with shiell 4ft for stock ; Other type available by customer requested
PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC EMI CONDUCTION & RADIATION (Note. 7) HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING PLUG CABLE
CONNECTOR NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerence: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 20% to 100% rated load. 7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
File Name:P50A-T-SPEC 2007-05-14
46.5~50W AC-DC Triple Output Desktop
Mechanical Specification
P 5500A --T s erriieess P A T se
Unit:mm
UL2464 18AWG 1220+100/-0
43
43
144.5
54.8 10.2
SWITCHING ADAPTOR
76
POWER LED 147
Plug Assignment
144.5 69.9 21.5
Standard plug: R1B (option)
P IN NO OUTPUT COM COM +5VDC - Vout +Vout
38
1
524 3 1 45
o
40
42
76
2 3 4 5
NAME PLATE
RUBBER FOOTX4
Derating Curve
Static Characteristics
100
100
LOAD (%)
LOAD (%)
0 10 20 30 40
80 60
60
0
50
60
70
80
90 100
260
Ta (
)
INPUT VOLTAGE
File Name:P50A-T-SPEC 2007-05-14