45W Single Output LED Power Supply
Features :
PLC-45
series
Universal AC input / Full range Adjustable output voltage and current level Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free air convection Built-in constant current limiting circuit Fully isolated plastic case with terminal block style of I/O Built-in active PFC function, comply with EN61000-3-2 class C ( 75% load) Class 2 power unit Pass LPS 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications Compliance to worldwide safety regulations for lighting 2 years warranty
F
110
M
M
SELV
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT PLC-45-12 12V 3.8A 0 ~ 3.8A 45.6W CONSTANT CURRENT REGION Note.6 9 ~ 12V PLC-45-15 15V 11.25 ~15V 3A 0 ~ 3A 45W 2.4Vp-p 14.5 ~ 16.2V 2.25 ~ 3.1A
LPS
PLC-45-20 20V 15 ~ 20V 2.3A 0 ~ 2.3A 46W 1.8Vp-p 19.5 ~ 22V 1.725 ~ 2.37A
( for 48V only)
( except for 48V )
PLC-45-24 24V 18 ~24V 1.9A 0 ~ 1.9A 45.6W 2.7Vp-p 24 ~ 26V 1.425 ~1.957A
PLC-45-27 27V 20.25 ~27V 1.7A 0 ~ 1.7A 45.9W 2.7Vp-p 25 ~ 30V 1.275 ~ 1.75A
PLC-45-36 36V 27 ~ 36V 1.25A 0 ~ 1.25A 45W 3.6Vp-p 32.5 ~ 39V 0.938 ~ 1.288A
PLC-45-48 48V 36 ~ 48V 0.95A 0 ~ 0.95A 45.6W 4.6Vp-p 43.6 ~ 51.8V 0.713 ~ 0.979A
RIPPLE & NOISE (max.) Note.2 2Vp-p VOLTAGE ADJ. RANGE Note.5 11.5 ~ 13V CURRENT ADJ. RANGE Note.5 2.85 ~ 3.914A VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP TIME VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) 10% 3.0% 5.0%
1500ms / 230VAC 3000ms / 115VAC at full load
Note.4 90 ~ 264VAC
127 ~ 370VDC
47 ~ 63Hz PF>0.92/115VAC, PF>0.9/230VAC at full load (Please refer to "Power Factor Characteristic" curve) 83.5% 0.55A/115VAC 40A/230VAC 95 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed Hiccup mode, recovers automatically after fault condition is removed. 13.8 ~ 16V 17.5 ~ 21V 22.8 ~ 25V 28 ~ 32V Protection type : Shut down o/p voltage, re-power on to recover 95 10 (TSW1) detect on heatsink of power transistor (Refer to "Derating Curve") Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -30 ~ +50 20 ~ 95% RH non-condensing -40 ~ +80 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes UL1310, TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), J61347-1, J61347-2-13 approved I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 75% load) ; EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61547, light industry level, criteria A 515Khrs min. MIL-HDBK-217F (25 ) 181.5*62*35mm (L*W*H) 0.41Kg; 30pcs/13.3Kg/0.67CUFT 31 ~ 35V 41 ~ 46V 54 ~ 60V 85% 0.25A/230VAC 86.5% 86.5% 86.5% 87.5% 87.5%
INPUT
EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (max.) LEAKAGE CURRENT OVER CURRENT SHORT CIRCUIT
很抱歉,暂时无法提供与“PLC-45-24”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+7.25
- 30+7
- 100+6.5
- 500+6