100W Single Output Switching Power Supply
Features :
PLN-100
series
Universal AC input / Full range (up to 295VAC) High efficiency 90% Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free air convection Built-in active PFC function IP64 design for indoor or outdoor installations Pass LPS UL1310 Class 2 power unit 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications Suitable for dry / damp locations Compliance to worldwide safety regulations for lighting 2 years warranty
F
110
M
M
SELV
LPS
( for 48V only)
( except for 48V )
IP64
PLN-100-36 36V 27 ~ 36V 2.65A 95.4W 150mVp-p 30.6 ~ 36V 2 ~ 2.65A 2.0% PLN-100-48 48V 36 ~ 48V 2A 96W 200mVp-p 40.8 ~ 48V 1.5 ~ 2A 2.0%
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT RATED POWER PLN-100-12 12V
Note.5 5A Note.5 60W
PLN-100-15 15V 11.25 ~ 15V 5A 75W 150mVp-p 12.8 ~ 15V 3.75 ~ 5A 3.0%
PLN-100-20 20V 15 ~ 20V 4.8A 96W 150mVp-p 17 ~ 20V 3.6 ~ 4.8A 3.0%
PLN-100-24 24V 18 ~ 24V 4A 96W 150mVp-p 20.4 ~ 24V 3 ~ 4A 3.0%
PLN-100-27 27V 20.25 ~ 27V 3.55A 95.85W 150mVp-p 23 ~ 27V 2.6 ~ 3.55A 3.0%
CONSTANT CURRENT REGION Note.6 9 ~ 12V
RIPPLE & NOISE (max.) Note.2 150mVp-p OUTPUT VOLTAGE ADJ. RANGE (SVR1) 10.2 ~ 12V CURRENT ADJ. RANGE(SVR2) 3.75 ~ 5A VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER CURRENT SHORT CIRCUIT PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS Note.7 SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF OTHERS DIMENSION PACKING
NOTE
3.0% 1.0% 2.0%
1200ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load 60ms/230VAC 30ms/115VAC at full load
Note.4 90 ~ 295VAC
127 ~ 417VDC
47 ~ 63Hz PF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve) 84.5% 86.5% 90% 90% 90% 0.45A/230VAC 90% 20V ~ 48V:1.1A/115VAC 89% 0.55A/230VAC 12V:0.8A/115VAC 0.4A/230VAC COLD START 40A/230VAC 75% load) ; EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A 303.1Khrs min. MIL-HDBK-217F (25 ) 200*70.5*35mm (L*W*H) 0.52Kg; 20pcs/12.5Kg/0.76CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2. 6. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:PLN-100-SPEC 2011-07-28
100W Single Output Switching Power Supply
Mechanical Specification
200 6.26
PLN-100
Case No.955A
series
Unit:mm
22.84
2-R2.5
310 20
310 20
70.5
35.25
AC/L(Brown) AC/N(Blue) FG (Green/Yellow)
T case
100
SVT 18AWG 2C
+V(Red) -V(Black)
T case: Max. Case Temperature.
6.26
22.84
SVT 18AWG 3C
Output voltage and current adjustment : remove the upper case and adjust through SVR1 & SVR2 shown in the diagram.
SVR1
SVR2
SVR1 Output voltage adjustment SVR2 Output current adjustment
Block Diagram
RECTIFIERS & FILTER O.L.P. FG PFC CONTROL DETECTION CIRCUIT O.V.P.
Fosc : 100KHz
I/P
EMI FILTER & RECTIFIERS
PFC CIRCUIT
POWER SWITCHING
35
+V -V
O.L.P.
PWM & PFC CONTROL
Derating Curve
Static Characteristics
100
100 90
80
230VAC Input only
80 70
60
LOAD (%)
40
LOAD (%)
-25 -10 0 15 30 40 50 (HORIZONTAL)
60 50 40
20
-30
90
100
125
135
145
155 165
175
180
200
230
295
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (V) 60Hz
File Name:PLN-100-SPEC 2011-07-28
100W Single Output Switching Power Supply
Power Factor Characteristic Constant Current Mode
1 .0 0 0 .9 8 0 .9 6 0 .9 4 0 .9 2 0 .9 0 0 .8 8 0 .8 6 0 .8 4 0 .8 2 0 .8 0 0 .7 8 50% 60% 70% 80% 90% 100%
(100W)
PLN-100
series
277V ac 230V ac 115V ac
PF
LOAD
EFFICIENCY vs LOAD (48V Model)
PLN-100 series possess superior working efficiency that up to 89% can be reached in field applications.
92 88 84
EFFICIENCY (%)
80 277Vac 76 72 68 64 60 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
230Vac 115Vac
DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method "direct drive" and "with LED driver". A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs. Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode [with LED driver, at area (A)] and CC mode [direct drive, at area (B)].
100
(B) Constant Current area (A) Constant Voltage area
75 (max.) (C) Hiccup Protection 50 100 Io (%)
Vo(%)
Typical LED power supply I-V curve