    RCP-MU - Power Control and Monitor System - Mean Well Enterprises Co., Ltd.

  • 数据手册
  • 价格&库存
RCP-MU 数据手册
Power Control and Monitor System Features : 1U low profile 19-inch rack mounting Control and monitor up to 3 RCP-1000 units RCP-MU Suitable for all kinds of RCP output (12V,24V,48V) Digital meters for output voltage, output current, and internal temperature on front panel Potential meter for adjusting output voltage of RCP-1000 unit on front panel Relay contacts and LED indicators for AC fail, DC fail, and over temperature warning Removable fixing accessory 3 years warranty Description : RCP-MU is the monitoring and control unit used for the RCP-1000 series rack power. It can decode the I C signal sent by RCP series and display through digital meters or relay contact signals. RCP-MU can also turn ON/OFF or trim the output voltage of RCP-1000 remotely that make the basic control more easily. 2 SPECIFICATION MODEL VOLTAGE RANGE FREQUENCY RANGE INPUT AC CURRENT (Typ.) INRUSH CURRENT (Typ.) MONITORING INPUTS DIGITAL METER OUTPUT CONTROL OUTPUT RELAY CONTACT LED INDICATOR FUNCTION REMOTE ON/OFF CONTROL VOLTAGE TRIM WORKING TEMP. ENVIRONMENT WORKING HUMIDITY STORAGE TEMP., HUMIDITY VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE RCP-MU 90 ~ 264VAC 47 ~ 63Hz 0.35A/115VAC 30A/115VAC 2 127 ~ 370VDC 0.2A/230VAC 50A/230VAC I C signal ( AC OK, DC OK, and over temperature alarm signals for each RCP-1000 unit ), output voltage of the RCP-1U rack Note.2 Display the DC output voltage, current, and internal temperature of each RCP-1000 unit Remote ON/OFF and output voltage trimming for each RCP-1000 unit Alarm for AC Fail, DC Fail, and Over Temperature ; rating : 30VDC, 1A AC Fail, DC Fail, Over Temperature The controlled RCP-1000 unit can be turned ON/OFF on the front panel for RCP-MU Output voltage of the controlled RCP-1000 unit and be trimmed by 10% on the front panel of RCP-MU -20 ~ +60 20~90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes Design refer to UL60950-1, TUV EN60950-1 I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC / 70% RH SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT EMS IMMUNITY OTHERS NOTE Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11 440*68*44mm (L*W*H) 1.15Kg; 6pcs/8Kg/1.27CUFT DIMENSION PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Resolution and tolerance of the values shown on the digital meter depends on the controlled RCP series. File Name:RCP-MU-SPEC 2008-08-07 Power Control and Monitor System Mechanical Specification RCP-MU Case No. 701A Unit:mm Your Reliab le Power Partne r PSU Output Adjus t ON OFF 1 2 3 PSU ON/O FF AC Fail DC Fail Tem p Alar m AC Fail DC Fail PSU1 1 2 3 Tem p Alar m AC Fail DC Fail VOL TS TEM P VOL TS AMP S PSU2 AMP S Tem p Alar m TEM P VOL TS AMP S TEM P BACK AC Input Terminal Block 100 - 240VAC N L Model Select Switch Alarm Signals Terminal Block Alarm Signals Temp 3 Alarm DC 3 Fail AC 3 Fail Temp 2 Alarm DC 2 Fail AC 2 Fail Temp 1 Alarm DC 1 Fail AC 1 Fail Output Voltage Lock Communication Connector w w w. m e a n w e l l . c o m Model : RCP-MU All alarm signals are potential free relays Supply Voltage: 100 - 240VAC 50/60Hz 0.35 - 0.2A MODEL SELECT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 VOLTS LOCK Communication 1 13 Enable Disable 14 25 1 2 3 123 123 AC Input Terminal Block Pin No. 1 2 3 Assignment FG AC/N AC/L Alarm Signals Pin No. Assignment Pin No. 1,2 3,4 5,6 Assignment Temp 3 Fail DC 3 Fail AC 3 Fail Pin No. 7,8 9,10 11,12 Assignment Temp 2 Fail DC 2 Fail AC 2 Fail Pin No. 13,14 15,16 17,18 Assignment Temp 1 Fail DC 1 Fail AC 1 Fail Communication Connector Pin No. Assignment Pin No. 1 2 3 4 5 Assignment ON/OFF-A AC-OK-A DC-OK-A V-TRIM-A T-ALARM-A Pin No. 6 7 8 9 10 Assignment +5V-AUX GND-AUX ON/OFF-B AC-OK-B DC-OK-B Pin No. 11 12 13 14 15 Assignment V-TRIM-B T-ALARM-B NC CS ON/OFF-C Pin No. 16 17 18 19 20 Assignment AC-OK-C DC-OK-C V-TRIM-C T-ALARM-C +S Pin No. 21 22 23 24 25 Assignment -S +V SCL SDA -V TOP PSU3 FRONT 7.1 AC Fail DC Fail Temp Alarm AC Fail DC Fail Temp Alarm AC Fail DC Fail Temp Alarm PSU1 PSU2 PSU3 ON PSU Output Adjust 1 2 3 OFF 1 2 3 PSU ON/OFF VOLTS AMPS TEMP VOLTS AMPS TEMP VOLTS AMPS TEMP Remote Adjust Remote ON/OFF Display of PSU1 Display of PSU2 440 466.1 483.6 Display of PSU3 File Name:RCP-MU-SPEC 2008-08-07 7.4 36.9 44 10.2 Partn er Your Relia ble Power 68 Power Control and Monitor System Block Diagram RCP-MU The diagram below only shows one set of input / output signals. One RCP-MU can control and monitor up to 3 units of RCP-1000 power unit. PSU ON/OFF ON / OFF PSU Output Adjust +V MCU LED Alarm Display Voltage Current Temperature AC Fail DC Fail Temp Alarm V- Trim -V Relay Contact AC Fail DC Fail Temp Alarm 12V 24V 48V 66V SCA / SDL Model Select Typical User Manual 1. Monitoring Input RCP-1U CN500 RCP-1U Address dip switch setting RCP-MU Communication ON 123456789 Module A Module B Module C OFF 2. Alarm Signal Relay Contact Function AC Fail DC Fail Temp Alarm Description When input AC fail, relay open, LED lights When output DC fail, relay open, LED lights When temperature exceed the limit of temperature, relay open, LED lights 3. Model Select Switch To get better display resolution, the correct output voltage of RCP-1000 that is monitored should be chosen. The factory original setting is for 48V models. ON (12V) 123 ON (24V) (48V) 123 ON 123 ON (66V) 123 OFF OFF OFF OFF 4. Output Voltage Lock The output voltage adjustment for RCP-1000 units can be enabled or disabled for different application needs. Enable (a) 123 (For special custom made RCP-1000 models) Voltage of power device can not be adjusted. Disable Enable (b) 123 Voltage of power device can be adjusted independently by VRs. Disable File Name:RCP-MU-SPEC 2008-08-07
RCP-MU 价格&库存

很抱歉,暂时无法提供与“RCP-MU”相匹配的价格&库存,您可以联系我们找货

免费人工找货