125W Dual Output Switching Power Supply
Features :
RID-125
series
Isolated output & GND for CH1,CH2 AC input range selectable by switch Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage All using 105 long life electrolytic capacitors Withstand 5G vibration test LED indicator for power on 100% full load burn-in test High realibility 3 years warranty
SPECIFICATION
MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY(Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE RID-125-1224 CH1 12V 3.7A
Note.6 1 ~ 7A Note.6 133.2W
RID-125-1248 CH2 24V 3.7A 0.4 ~ 5A 200mVp-p +8,-5% 1.0% 5.0% CH1 12V 2.3A 1 ~ 7A 138W 120mVp-p CH1: 11.4 ~ 13.2V 2.0% 0.5% 1.0% 240mVp-p +8,-5% 1.0% 5.0% CH2 48V 2.3A 0.2 ~ 2.5A
RID-125-2448 CH1 24V 2A 0.5 ~ 4A 144W 200mVp-p CH1: 22.8 ~ 26.4V 1.0% 0.5% 1.0% 240mVp-p 4.0% 1.0% 3.0% CH2 48V 2A 0.2 ~ 2.5A
RIPPLE & NOISE (max.) Note.2 120mVp-p CH1: 11.4 ~ 13.2V VOLTAGE TOLERANCE Note.3 2.0%
Note.4 Note.5
0.5% 1.0% 500ms, 20ms/230VAC 36ms/230VAC 47 ~ 63Hz 85%
1200ms, 30ms/115VAC at full load 248 ~ 373VDC(300VAC peak 5sec. No damage) 86%
30ms/115VAC at full load
88 ~ 132VAC / 176 ~ 264VAC selected by switch 85%
3A/115VAC 2A/230VAC COLD START 40A/230VAC
很抱歉,暂时无法提供与“RID-125_10”相匹配的价格&库存,您可以联系我们找货
免费人工找货