120W Reliable Green Medical Power Supply
RPS-120
series
User’s Manual
+
+
■
‧
‧
‧
‧
‧ⅠⅡ
‧
‧Extremely low leakage current
‧
‧
‧
‧
■
‧
‧
‧
‧
‧
■
■
ⅠⅡ
150μ
■
{
Blank : PCB type
-C : Enclosed type
File Name:RPS-120-SPEC 2022-03-18
RPS-120
120W Reliable Green Medical Power Supply
series
SPECIFICATION
MODEL
RPS-120-12□
RPS-120-15□
RPS-120-24□
RPS-120-27□
RPS-120-48□
12V
15V
24V
27V
48V
10A
8A
5A
4.5A
2.5A
5.6A
3.5A
3.15A
1.75A
120W
120W
121.5W
120W
84W
84W
85W
84W
RIPPLE & NOISE (max.) Note.2 100mVp-p
120mVp-p
150mVp-p
150mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
DC VOLTAGE
CURRENT
RATED
POWER
OUTPUT
10CFM
Convection 7.0A
10CFM
120W
Convection 84W
14.3~15.8V
22.8~25.2V
25.6 ~ 28.4V
45.6 ~50.4V
VOLTAGE TOLERANCE Note.3 ±2.0%
±2.0%
±1.0%
±1.0%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
LOAD REGULATION
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
SETUP, RISE TIME
500ms, 30ms/230VAC
HOLD UP TIME (Typ.)
50ms/230VAC
90%
91%
LINE REGULATION
11.4~12.6V
10ms/115VAC at full load
VOLTAGE RANGE Note.4 80 ~ 264VAC
FREQUENCY RANGE
INPUT
113 ~ 370VDC
47 ~ 63Hz
EFFICIENCY (Typ.)
89%
AC CURRENT (Typ.)
2.1A/115VAC
INRUSH CURRENT (Typ.)
COLD START 30A/115VAC
LEAKAGE CURRENT(max.) Note.5
Earth leakage current < 150μA/264VAC , Touch current < 80μA/264VAC
OVERLOAD
PROTECTION
500ms, 30ms/115VAC at full load
89%
OVER TEMPERATURE
FUNCTION FAN SUPPLY
60A/230VAC
115~150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
16.5 ~ 19.5V
13.2 ~ 15.6V
OVER VOLTAGE
90%
1.2A/230VAC
26.4 ~ 31.2V
29.7 ~ 35V
52.8 ~ 62.4V
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
12V@0.5A for driving a fan ; tolerance -15% ~ +10% at main output 40% rated current (10CFM)
WORKING TEMP.
-30 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
OPERATING ALTITUDE Note.6 4000 meters
SAFETY STANDARDS
IEC60601-1, TUV BS EN/EN60601-1, EAC TP TC 004 , UL ANSI / AAMI ES60601-1 (3.1 version),
CAN/CSA-C22.2 No. 60601-1:14 - Edition 3 approved; Design refer to BS EN/ EN60335-1
ISOLATION RESISTANCE Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP
WITHSTAND VOLTAGE
I/P-O/P:4KVAC
I/P-FG:2KVAC
O/P-FG:1.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
SAFETY &
EMC
(Note 7)
EMC IMMUNITY
OTHERS
NOTE
Parameter
Standard
Test Level / Note
Conducted emission
BS EN/EN55011 (CISPR11)
Class B
Radiated emission
BS EN/EN55011 (CISPR11)
Class B
Harmonic current
Voltage flicker
BS EN/EN60601-1-2
BS EN/EN61000-3-2
Class A
BS EN/EN61000-3-3
-----
Parameter
Standard
Test Level / Note
ESD
BS EN/EN61000-4-2
Level 4, 15KV air ; Level 4, 8KV contact
RF field susceptibility
BS EN/EN61000-4-3
Level 3, 10V/m( 80MHz~2.7GHz )
Table 9, 9~28V/m( 385MHz~5.78GHz )
EFT bursts
Surge susceptibility
Conducted susceptibility
BS EN/EN61000-4-4
Level 3, 2KV
BS EN/EN61000-4-5
Level 4, 4KV/Line-FG; 2KV/Line-Line
BS EN/EN61000-4-6
Level 3, 10V
Magnetic field immunity
BS EN/EN61000-4-8
Voltage dip, interruption
BS EN/EN61000-4-11
Level 4, 30A/m
100% dip 1 periods, 30% dip 25 periods,
100% interruptions 250 periods
MTBF
3732.9K hrs min.
DIMENSION (L*W*H)
PCB:101.6*50.8*29mm or 4" * 2" *1.141" inch ; Enclosed type:103.4*62*40mm or 4.07" * 2.44" *1.57" inch
PACKING
PCB:0.15Kg; 72pcs/11.8Kg/0.84CUFT ; Enclosed type:0.24Kg; 60pcs/15.4Kg/1.06CUFT
Telcordia SR-332 (Bellcore) ; 653.6K hrs min.
MIL-HDBK-217F (25℃)
μ
μ
6. ℃℃
(as available on http://www.meanwell.com)
※:https://www.meanwell.com/serviceDisclaimer.aspx
File Name:RPS-120-SPEC 2022-03-18
RPS-120
120W Reliable Green Medical Power Supply
series
Block Diagram
fosc : 65KHz
EMI FILTER
&
RECTIFIER
EMI
FILTER
I/P
POWER
SWITCHING
RECTIFIERS
&
FILTER
RECTIFIERS
&
FILTER
FG
O.T.P.
+V
-V
+12V
FAN SUPPLY
DETECTION
CIRCUIT
O.L.P.
CONTROL
O.V.P.
Derating Curve
100
With 10CFM Fan for RPS-120(-C)
80
70
Convection
for RPS-120(-C) 24~48V
LOAD (%)
60
40
Convection
for RPS-120(-C) 12~15V
20
-30
0
10
20
30
40 45 50
70 (HORIZONTAL)
60
AMBIENT TEMPERATURE (℃)
Output Derating VS Input Voltage
100
90
80
LOAD (%)
70
60
50
40
80
90
115
120
130
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:RPS-120-SPEC 2022-03-18
RPS-120
120W Reliable Green Medical Power Supply
series
Mechanical Specification
RPS-120 (PCB Type)
Top View
50.8
FAN
5cm
3.175
※Note
10CFM
Air flow
direction
1 2
CN101
HS1
44.45
3
2
1
3.175
SVR1 LED
1
2
3
4
HS2
FS1
T4A/250V
CN2
FS2
T4A/250V
95.25
4 -ψ
3.3
29
101.6
3 max.
50.8
CN1
Side View
File Name:RPS-120-SPEC 2022-03-18
RPS-120
120W Reliable Green Medical Power Supply
series
Mechanical Specification
Case No.245A
RPS-120-C (Enclosed Type)
Unit:mm
Side View
Top View
Side View
Side View
103.4
78
12.7
100
1.7
2-R1.75
20
25
40
2-M3 L=4
Side View
51.7
FAN
10CFM
5cm
Air flow
direction
CN101
CN1
12
1
2
3
4
62
3
2
1
CN2
30.8
2-M3 L=2
24.2
55
Bottom View
File Name:RPS-120-SPEC 2022-03-18
120W Reliable Green Medical Power Supply
RPS-120
series
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No.
1
2
3
Assignment
AC/N
No Pin
AC/L
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
DC Output Connector (CN2) : JST B4P-VH or equivalent
Pin No.
1,2
3,4
Assignment
+V
-V
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
FAN Connector(CN101) : JST S2B-PH-K-S or equivalent
Pin No. Assignment
1
DC COM(FAN-)
2
+12V(FAN+)
Mating Housing
Terminal
JST PHR-2
or equivalent
JST SPH-002T-P0.5S
or equivalent
1.HS1,HS2 cannot be shorted.
2.HS1 must have safety isolation distance with system case.
※Note : 1. The FAN supply is designed to serve as the source of the additive external fan for the cooling of the power supply,
enabling the full load delivery and assuring the best life span of the product. Please do not use this FAN supply to
drive other devices.
2.The PCB type(Blank type)model delivers EMI Class B for both conducted emission and radiated emission for the power
supply, when configured into either Class Ⅰ(with FG) or Class Ⅱ (no FG) system.
3.The Enclosed type(-C type) model is not suitable for the configuration within a Class Ⅱ (no FG) system but is
suggested to used within a Class Ⅰ(with FG) system.
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
File Name:RPS-120-SPEC 2022-03-18
很抱歉,暂时无法提供与“RPS-120-15-C”相匹配的价格&库存,您可以联系我们找货
免费人工找货