RPT-160D

RPT-160D

  • 厂商:

    MEANWELL(明纬)

  • 封装:

  • 描述:

    AC/DC CONVERTER 5V 12V 24V 95W

  • 数据手册
  • 价格&库存
RPT-160D 数据手册
160W Triple Output Medical Type Features : R P T- 1 6 0 series Universal AC input / Full range Built-in active PFC function Protections: Short circuit / Overload / Over voltage / Over temperature 5"x3" compact size Free air convection for 100W and 145W with 20.5 CFM forced air With power good and fail signal output No load power consumption under 0.75W by PS-ON control (G model) Standby 5V@0.8A with fan, @0.6A without fan (G model) 3 years warranty RPT G G: With 5Vsb & no load power consumption < 0.75 W Blank: Basic function (without 5Vsb) 160A SPECIFICATION MODEL OUTPUT NUMBER DC VOLTAGE RPT -160A CH1 5V CH2 12V 5.5A CH3 -5V 1A RPT -160B CH1 5V 14A CH2 12V 5A CH3 -12V 1A 0.1 ~ 1A RPT -160C CH1 5V 14A CH2 15V 3.6A CH3 -15V 1A RPT -160D CH1 5V 11A CH2 12V 5A CH3 24V 1.2A 0.15 ~ 1.2A RATED CURRENT (20.5CFM) 14A CURRENT RANGE (convection) 0.6 ~ 9A RATED POWER (convection) Note.7 98.6W OUTPUT RATED POWER (20.5CFM) Note.8 145W VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD OVER VOLTAGE PROTECTION OVER TEMPERATURE 0.2 ~ 3.8A 0.1 ~ 0.6A 0.6 ~ 9A 98.4W 146W 0.2 ~ 3.4A 0.1 ~ 0.8A 0.6 ~ 9A 99W 143W 0.1 ~ 2.6A 0.1 ~ 0.8A 0.3 ~ 8A 98.2W 147.8W 0.2 ~ 2.6A 0.15 ~ 1A CURRENT RANGE (20.5CFM) 0.6 ~ 14A 0.2 ~ 5.5A 0.1 ~ 1A 0.6 ~ 14A 0.2 ~ 5A 0.6 ~ 14A 0.1 ~ 3.6A 0.1 ~ 1A 0.3 ~ 11A 0.2 ~ 5A RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 120mVp-p 100mVp-p 120mVp-p 120mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 120mVp-p 200mVp-p CH1:5 ~ 5.5V 2.0% 5.0% 0.5% 1.5% 1.0% 3.0% -5,+7% 1.0% -5,+6% 2.0% 0.5% 1.5% 5.0% 1.0% 3.0% -4,+5% 1.0% -4,+5% 2.0% 0.5% 2.0% 4.0% 1.0% 3.0% 8.0% 1.0% 8.0% 2.0% 0.5% 1.5% 5.0% 1.0% 3.0% +7,-5% 1.0% -3,+4% 1800ms, 30ms/230VAC Note.6 90 ~ 264VAC 3500ms, 30ms/115VAC at full load 16ms/230VAC/115VAC at full load 127 ~ 370VDC PF>0.98/115VAC at full load 84% 83% 83% 47 ~ 63Hz PF>0.93/230VAC 84% 1.8A/115VAC 0.9A/230VAC COLD START 35A/115VAC 70A/230VAC Earth leakage current 1ms POWER GOOD / POWER FAIL 500ms>PG>10ms -20 ~ +70 (Refer to "Derating Curve") WORKING TEMP. WORKING HUMIDITY 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes ANSI/AAMI ES60601-1, TUV EN60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A 191.4Khrs min. MIL-HDBK-217F (25 127*76.2*34.6mm (L*W*H) 0.33Kg; 36pcs/12.9Kg/0.79CUFT ) ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION EMC IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) 5. HS1,HS2 & HS3 can not be shorted. 6. Derating may be needed under low input voltages. Please check the derating curve for more details. 7. The rated power includes 5Vsb @ 0.6A. 8. The rated power includes 5Vsb @ 0.8A. 160W Triple Output Medical Type Mechanical Specification FAN 20.5CFM min. 5 R P T- 1 6 0 series Unit:mm AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 CN3 1 2 SVR1 Assignment AC/L No Pin AC/N 5cm Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent HS1 DC Output Connector (CN2) : JST B8P-VH or equivalent 1 2 3 4 5 6 7 8 FS1 CN1 FS2 1 2 3 HS2 HS3 CN2 CN901 LED Pin No. 1,2,3,4 5,6 7 8 CN901 Assignment COM CH1 CH2 CH3 Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent 76.2 66.2 Power Good Connector(CN3):JST B2B-XH or equivalent Pin No. 1 2 Status PG GND Mating Housing JST XHP or equivalent Terminal JST SXH-001T-P0.6 or equivalent 4- 5 117 127 3.5 1234 5VSB Connector(CN901) : JST B-XH or equivalent PS/ON 5mA(max.) 34.6 GND Pin No. 1 2,4 3 Assignment PS/ON GND 5VSB Mating Housing JST XHP or equivalent Terminal JST SXH-001T or equivalent HS1,HS2,HS3 can not be shorted 3 max. Block Diagram POWER SWITCHING PWM CONTROL I/P EMI FILTER RECTIFIERS & PFC POWER SWITCHING FG O.L.P. CONTROL +5VSB DETECTION CIRCUIT RECTIFIERS & FILTER RECTIFIERS & FILTER RECTIFIERS & FILTER RECTIFIERS & FILTER PG DETECTION CIRCUIT O.V.P. fosc :100KHz +5VSB V3 +V2 +V1 COM PG PS/ON CONTROL PS/ON Derating Curve Output Derating VS Input Voltage 100 100 With FAN 90 80 70 80 60 LOAD (%) LOAD (%) 60 70 (HORIZONTAL) Without FAN 40 60 50 40 20 -20 0 10 20 30 40 50 90 95 100 115 120 140 160 180 200 220 240 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (VAC) 60Hz File Name:RPT-160-SPEC 2012-02-20
RPT-160D 价格&库存

很抱歉,暂时无法提供与“RPT-160D”相匹配的价格&库存,您可以联系我们找货

免费人工找货