RSD-60G-24

RSD-60G-24

  • 厂商:

    MEANWELL(明纬)

  • 封装:

    -

  • 描述:

    RSD-60G-24

  • 数据手册
  • 价格&库存
RSD-60G-24 数据手册
60W Reliable Railway DC-DC Converter RSD-60 series User’s Manual UL62368-1 AS/NZS62368-1 TPTC004 IEC62368-1 ■ Features Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard Ultra compact and 1U low profile(25mm) 4:1 wide input range No minimum load required Protections: Short circuit / Overload / Over voltage / ■ Applications  Bus,tram,metro or railway system  Highly vibrating, highly dusty, extremely low or high temperature harsh environment  Wireless network Telecom or datacom system Industry control system Input reverse polarity 4000VDC I/O isolation (Reinforced isolation) Half encapsulated , cooling by free air convection -40~+70℃ wide working temperature Built-in constant current limiting circuit LED indicator for power on 3 years warranty ■ GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx ■ Description RSD-60 is a 60W enclosed type DC-DC reliable railway converter. This series is compliant with BS EN/EN50155/ IEC60571 railway standard, constituting three types of models with 4:1 wide but different input ranges 9~36V/18~72V/40~160V, suitable for railway and all kinds of transportation systems exploiting the frequently used standard input voltages such as 12V, 24V, 36V, 48V, 72V, 96V and 110V. Various output voltages, 3.3V, 5V, 12V and 24V are available for selection. This series has the capability of working under -40~+70℃, low ripple and noise, supreme EMC characteristics, 4KVDC I/P-OP, low enclosure profile 25mm and an interior with semi-potted silicone. It does not only well fits the in-car systems or the facilities by rails for railway, trams and buses but also can be used in the harsh environment with high vibration, high dust, extremely low or high temperature, etc. ■ Model Encoding RSD - 60 G - 5 Output voltage (3.3/5/12/24Vdc) Input voltage (G: 9~36Vdc, L: 18~72Vdc, H: 40~160Vdc) Rated wattage Series name File Name:RSD-60-SPEC 2022-09-20 RSD-60 60W Reliable Railway DC-DC Converter series SPECIFICATION RSD-60G-3.3 RSD-60G-5 RSD-60G-12 RSD-60G-24 RSD-60L-3.3 RSD-60L-5 RSD-60L-12 RSD-60L-24 DC VOLTAGE 3.3V 5V 12V 24V 3.3V 5V 12V 24V RATED CURRENT 12A 12A 5A 2.5A 12A 12A 5A 2.5A CURRENT RANGE RATED POWER 0 ~ 12A 39.6W 0 ~ 12A 60W 0 ~ 5A 60W 0 ~ 2.5A 60W 0 ~ 12A 39.6W 0 ~ 12A 60W 0 ~ 5A 60W 0 ~ 2.5A 60W RIPPLE & NOISE (max.) Note.2 60mVp-p 100mVp-p 50mVp-p 50mVp-p 60mVp-p 60mVp-p 50mVp-p 50mVp-p VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% LINE REGULATION ±0.5% ±0.5% ±0.3% ±0.2% ±0.5% ±0.5% ±0.3% ±0.2% LOAD REGULATION ±0.5% ±0.5% ±0.3% ±0.2% ±0.5% ±0.5% ±0.3% ±0.2% SETUP, RISE TIME 100ms, 60ms at full load HOLD UP TIME (Typ.) Please refer to page 5 Hold up Time( Load de-rating curve ) 88.5% 89% 93% 91.5% 0.95A/48VDC 1.5A/48VDC MODEL OUTPUT VOLTAGE RANGE CONTINUOUS 9 ~ 36VDC INPUT 18 ~ 72VDC EFFICIENCY (Typ.) 86.5% 88% DC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.1A/24VDC 3A/24VDC 92% 90% 20A/48VDC 20A/24VDC EN50155:2007-G type comply with S1 level(3ms) @ full load,S2 level(10ms) @50% load ; L type comply with S2 level ( 10 ms ) @ full load INTERRUPTION OF VOLTAGE SUPPLY EN50155:2017-Comply with S1 level OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP. TEMP. COEFFICIENT VIBRATION 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 4.3 ~ 5.3V 5.75 ~ 7V 13.8 ~ 16.2V 27.6 ~ 32.4V 4.3 ~ 4.95V 5.75 ~ 7V 13.8 ~ 16.2V 27.6 ~ 32.4V Protection type : Shut down o/p voltage, re-power on to recover -40 ~ +55℃ (no derating) ; +70℃ @ 60% load by free air convection ; +70℃ (no derating with external base plate) 5 ~ 95% RH non-condensing -40 ~ +85℃ ±0.03%/℃ (0 ~ 50℃) 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373 OPERATING ALTITUDE 5000 meters SAFETY STANDARDS WITHSTAND VOLTAGE IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1 ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH Parameter Standard I/P-O/P:4KVDC I/P-FG:2.5KVDC Conducted Radiated O/P-FG:2.5KVDC Test Level / Note Harmonic Current BS EN/EN55032 BS EN/EN55032 BS EN/EN61000-3-2 SAFETY & Voltage Flicker BS EN/EN61000-3-3 ----- EMC BS EN/EN55035 (Note 4) Parameter ESD Standard BS EN/EN61000-4-2 Test Level / Note Level 3, ±8KV air ; Level 3, ±6KV contact Radiated Field BS EN/EN61000-4-3 Level X, 20V/m EFT / Burst BS EN/EN61000-4-4 Surge BS EN/EN61000-4-5 Level 3,1KV Line-Line, Level 3, 2KV Line-Earth Conducted BS EN/EN61000-4-6 Level 3 EMC EMISSION EMC IMMUNITY RAILWAY STANDARD MTBF OTHERS DIMENSION PACKING NOTE Class A Class B ----- Level 3, 2KV at power Level 4, 2KV at signal Compliance to BS EN/EN45545-2 for fire protection ; BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC 2738.8K hrs min. Telcordia SR-332 (Bellcore) ; 593.9K hrs min. 128*60*25mm (L*W*H) 0.29Kg; 48pcs/14.9Kg/0.75CUFT MIL-HDBK-217F (25℃) 1. All parameters NOT specially mentioned are measured at 24,48VDC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) 5. Strongly recommended that external output capacitance should not exceed 5000uF. 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:RSD-60-SPEC 2022-09-20 RSD-60 60W Reliable Railway DC-DC Converter series SPECIFICATION RSD-60H-3.3 RSD-60H-5 RSD-60H-12 RSD-60H-24 DC VOLTAGE 3.3V 5V 12V 24V RATED CURRENT 12A 12A 5A 2.5A CURRENT RANGE RATED POWER 0 ~ 12A 39.6W 0 ~ 12A 60W 0 ~ 5A 60W 0 ~ 2.5A 60W RIPPLE & NOISE (max.) Note.2 80mVp-p 60mVp-p 50mVp-p 50mVp-p VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±2.0% ±2.0% LINE REGULATION ±0.5% ±0.5% ±0.3% ±0.2% LOAD REGULATION ±0.5% ±0.5% ±0.3% ±0.2% SETUP, RISE TIME 100ms, 60ms at full load HOLD UP TIME (Typ.) Please refer to page 5 Hold up Time( Load de-rating curve ) 92.5% 91.5% MODEL OUTPUT VOLTAGE RANGE CONTINUOUS 40 ~ 160VDC INPUT EFFICIENCY (Typ.) 87.5% 89% DC CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.415A/110VDC 0.62A/110V 20A/110VDC EN50155:2007-H-type comply with S2 level(10ms) @ full load INTERRUPTION OF VOLTAGE SUPPLY EN50155:2017-Comply with S1 level OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP. TEMP. COEFFICIENT VIBRATION 5.75 ~ 7V 13.8 ~ 16.2V 27.6 ~ 32.4V Protection type : Shut down o/p voltage, re-power on to recover -40 ~ +55℃ (no derating) ; +70℃ @ 60% load by free air convection ; +70℃ (no derating with external base plate) 5 ~ 95% RH non-condensing -40 ~ +85℃ ±0.03%/℃ (0 ~ 50℃) 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373 5000 meters SAFETY STANDARDS WITHSTAND VOLTAGE IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1 ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH Parameter Standard EMC EMISSION EMC (Note 4) EMC IMMUNITY RAILWAY STANDARD MTBF DIMENSION PACKING NOTE 4.3 ~ 4.95V OPERATING ALTITUDE SAFETY & OTHERS 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC Test Level / Note Conducted Radiated Harmonic Current BS EN/EN55032 Class A BS EN/EN55032 BS EN/EN61000-3-2 Voltage Flicker BS EN/EN61000-3-3 Class B --------- BS EN/EN55035 Parameter ESD Standard BS EN/EN61000-4-2 Test Level / Note Level 3, ±8KV air ; Level 3, ±6KV contact Radiated Field BS EN/EN61000-4-3 EFT / Burst BS EN/EN61000-4-4 Level X, 20V/m Level 3, 2KV at power Surge BS EN/EN61000-4-5 Level 3,1KV Line-Line, Level 3, 2KV Line-Earth Conducted BS EN/EN61000-4-6 Level 3 Level 4, 2KV at signal Compliance to BS EN/EN45545-2 for fire protection ; BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC 2738.8K hrs min. Telcordia SR-332 (Bellcore) ; 593.9K hrs min. 128*60*25mm (L*W*H) 0.29Kg; 48pcs/14.9Kg/0.75CUFT MIL-HDBK-217F (25℃) 1. All parameters NOT specially mentioned are measured at 110VDC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) 5. Strongly recommended that external output capacitance should not exceed 5000uF. 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:RSD-60-SPEC 2022-09-20 RSD-60 60W Reliable Railway DC-DC Converter series Block Diagram fosc : 130KHz RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING FG DETECTION CIRCUIT PWM CONTROL O.L.P. +V -V O.V.P. Input Fuse There is one fuse connected in series to the positive input line, which is used to protect against abnormal surge. Fuse specifications of each model are shown as below. Type Fuse Type Reference and Rating G Time-Lag CONQUE MST, 10A, 250V L Time-Lag CONQUE MST, 5A, 250V H Time-Lag CONQUE MST, 2.5A, 250V Input Reverse Polarity Protection There is a MOSFET connected in series to the negative input line. If the input polarity is connected reversely, the MOSFET opens and there will be no output to protect the unit. Input Range and Transient Ability The series has a wide range input capability. With ±40% of rated input voltage, it can withstand that for 1 second. Input Under-Voltage Protection If input voltage drops below Vimin, the internal control IC shuts down and there is no output voltage. It recovers automatically when input voltage reaches above Vimin,please refer to the cruve below. RSD-60G-24 Vo RSD-60L-24 30 Vo 25 25 20 20 15 Turn On Turn Off 10 5 RSD-60H-24 30 Vo 25 20 15 Turn On Turn Off 10 6 8.3 8 10 12 14 16 Vin 15 Turn On Turn Off 10 5 5 6.3 0 30 12.3 0 12 16.3 16 20 24 28 32 Vin 25.5 0 24 37 32 40 48 56 Vin Inrush Current Inrush current is suppressed by a resistor during the initial start-up, and then the resistor is bypassed by a MOSFET to reduce power consumption after accomplishing the start-up. File Name:RSD-60-SPEC 2022-09-20 RSD-60 60W Reliable Railway DC-DC Converter series Hold-up Time En50155: 2007 version - L/H type is in compliance with S2 level (10ms), while G types are in compliance with S1 level (3ms) at full load output condition. To fulfil the requirements of S2 level (10ms), G types require de-rating their output load to 50%, please refer to the curve diagrams below. LOAD 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% RSD-60G-5 LOAD RSD-60G-3.3 0ms 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms TIME TIME 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% RSD-60G-24 LOAD LOAD RSD-60G-12 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms TIME 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms TIME EN50155: 2017 version - Comply with S1 level (3ms) Output Voltage Adjustment This function is optional, which the standard product does not have it. If you do need the function, please contact MW for details. File Name:RSD-60-SPEC 2022-09-20 RSD-60 60W Reliable Railway DC-DC Converter series Efficiency vs Load & Vin Curve The efficiency vs load & Vin curves of each model are shown as below. RSD-60G-5 RSD-60G-12 96% 92% 92% 92% 88% 88% 84% 80% 36VDC 76% 24VDC 9VDC 72% 68% 84% 80% 36VDC 76% 24VDC 9VDC 72% 10% 20% 30% 40% 50% 60% 70% 80% 90% 10% 20% 30% 40% RSD-60G-24 36VDC 76% 24VDC 50% 60% 70% 80% 90% 10% 100% RSD-60L-3.3 92% 92% 88% 88% 84% 80% 36VDC 76% 24VDC 9VDC 72% 84% 80% 72VDC 76% 48VDC 18VDC 72% EFFICIENCY 92% 80% 90% 10% 100% 20% 30% 40% 50% 60% 70% 80% 90% 100% RSD-60L-24 92% 88% 80% 72VDC 76% 48VDC 18VDC 72% 84% 80% 72VDC 76% 48VDC 18VDC 72% EFFICIENCY 92% 88% EFFICIENCY 92% 50% 60% 70% 80% 90% 10% 100% 20% 30% 40% 50% 60% 70% 80% 90% 100% 160VDC 110VDC 40VDC 10% 40VDC 72% 68% 88% 84% 80% 160VDC 76% 110VDC 40VDC 72% 30% 40% 50% 40% 60% 70% 80% 90% 60% 70% 80% 90% 100% 88% 84% 80% 160VDC 76% 110VDC 40VDC 72% 64% 64% 100% 50% 68% 68% 64% EFFICIENCY 110VDC EFFICIENCY 92% 20% 30% RSD-60H-24 96% 10% 20% LOAD RSD-60H-12 76% 100% 72% 92% 160VDC 90% 76% 96% 80% 80% 80% 92% 84% 70% 84% 96% 88% 60% 88% LOAD LOAD RSD-60H-5 50% 64% 64% 64% 40% 40% 68% 68% 68% 30% 30% RSD-60H-3.3 96% 20% 20% LOAD 96% 10% 18VDC 10% 96% 84% 100% 48VDC LOAD RSD-60L-12 90% 72% 64% 70% 80% 72VDC 68% 60% 70% 76% 64% LOAD 60% 80% 68% 50% 50% 84% 64% 40% 40% 88% 68% 30% 30% RSD-60L-5 96% 20% 20% LOAD 96% 10% 9VDC 72% 96% EFFICIENCY EFFICIENCY 80% LOAD LOAD EFFICIENCY 84% 64% 64% 100% 88% 68% 68% 64% EFFICIENCY EFFICIENCY 96% EFFICIENCY EFFICIENCY RSD-60G-3.3 96% 10% 20% 30% 40% 50% 60% LOAD LOAD 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD Parallel and Series Connection A.Operation in Parallel Since RSD-60 series don't have built-in parallel circuit, it can only use external circuits to achieve the redundant operation but not increase the current rating. 1.Add a diode at the positive-output of each power supply (as shown as below), the current rating of the diode should be larger than the maximum output current rating and attached to a suitable heat sink. This is only for redundant use (increase the reliability of the system) and users have to check suitability of the circuit by themselves. + I/P E IN D1 PS1 I/P RL + I/P D2 PS2 I/P - 2.When using S.P.S. in parallel connection, the leakage current will increase at the same time. This could pose as a shock hazard for the user. So please contact the supplier if you have this kind of application. B.Operation in Series RSD-60 can be operated in series. Here are the methods of doing it: 1.Positive and negative terminals are connected as shown as below. According to the connection, you can get the positive and negative output voltages for your loads. + I/P PS1 E IN +V RL I/P - I/P + COM PS2 I/P RL - -V File Name:RSD-60-SPEC 2022-09-20 RSD-60 60W Reliable Railway DC-DC Converter series 2.Increase the output voltage (current does not change). Because RSD-60 series have no reverse blocking diode in the unit, you should add an external blocking diode to prevent the damage of every unit while starting up. The voltage rating of the external diode should be larger than V1+V2 (as shown as below). +V + I/P E IN PS1 V1 I/P - I/P + D1 V1+V2 R L PS2 V2 I/P D2 - -V Overload Protection If the output draw up to 105~135% of its output power rating, the converter will go into overload protection which is constant current mode. After the faulty condition is removed, it will recover automatically. Please refer to the diagram below for the detail operation characteristic. Please note that it's not suitable to operate within the overload region continuously, or it may cause to over temperature and reduce the life of the power supply unit or even damage it. Vo(%) 100 Overload region 50 0 50 100 Io(%) 150 Over Voltage Protection The converter shuts off to protect itself when the output voltage drawn exceeds 115~140% of its output rating. It must be repowered on to recover. LED Indicator Equipped with a built-in LED indicator, the converter provides an easy way for users to check its condition through the LED indicator. Green : normal operation; No signal: no power or failure. Derating Curve a.Single unit operation If the unit has no iron plate mounted on its bottom, the maximum ambient temperature for the unit will be 55℃ as operating under full load condition. It requires de-rating output current when ambient temperature is between 55~70℃, please refer to the de-rating curve as below. (Others) 100 100 90 80 (G/L/H 5V) 80 70 40 60 G:Vin ≥ 24V L:Vin ≥ 48V H:Vin ≥ 110V LOAD (%) LOAD (%) 60 20 -40 -35 0 10 20 30 40 50 55 60 AMBIENT TEMPERATURE (℃ ) 70 (HORIZONTAL) 50 40 20 G:9V L:18V G:40V 18V 36V 80V (HORIZONTAL) INPUT VOLTAGE (VDC) File Name:RSD-60-SPEC 2022-09-20 RSD-60 60W Reliable Railway DC-DC Converter series RATED CURRENT (%) 100 80 60 40 20 -30 0 10 20 30 40 50 60 70 80 (HORIZONTAL) Tcase (℃) Suitable installation methods are shown as below. Since RSD-60 is a semi-potted model, its thermal performances for the following installation methods are similar and share the same derating curve. b.Operate with additional iron plate If it is necessary to fulfil the requirements of EN50155 TX level that operate the unit fully-loaded at 70℃, RSD-60 series must be installed onto an iron plate on the bottom. The size of the suggested iron plate is shown as below. In order for optimal thermal performance, the iron plate must have an even & smooth surface and RSD-60 series must be firmly mounted at the center of the iron plate. Unit:mm M3*4 0 2 36 360 The load vs ambient temperature curve is shown as below. 100 80 LOAD (%) 60 40 20 -40 0 10 20 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE (℃ ) File Name:RSD-60-SPEC 2022-09-20 60W Reliable Railway DC-DC Converter RSD-60 series Suitable installation methods are shown as below. Since RSD-60 is a semi-potted model, its thermal performances for the following installation methods are similar and share the same derating curve. iron plate Immunity to Environmental Conditions Standard Test method Test conditions Status Cooling Test EN 50155 section 12.2.3 (Column 2, Class TX) EN 60068-2-1 Temperature: -40℃ Dwell Time: 2 hrs/cycle Dry Heat Test EN 50155 section 12.2.4 (Column 2, Class TX) EN 50155 section 12.2.4 (Column 3, Class TX & Column 4, Class TX) EN 60068-2-2 Temperature: 70℃ / 85℃ Duration: 6 hrs / 10min PASS Damp Heat Test, Cyclic EN 50155 section 12.2.5 EN 60068-2-30 Temperature: 25℃~55℃ Humidity: 90%~100% RH Duration: 48 hrs PASS Vibration Test EN 50155 section 12.2.11 EN 61373 Temperature: 19℃ Humidity: 65% Duration: 10 mins PASS Increased Vibration Test EN 50155 section 12.2.11 EN 61373 Temperature: 19℃ Humidity: 65% Duration: 5 hrs PASS Shock Test EN 50155 section 12.2.11 EN 61373 Temperature: 21± 3℃ Humidity: 65 ± 5% Duration: 30ms*18 PASS Low Temperature Storage Test EN 50155 section 12.2.3 (Column 2, Class TX) EN 60068-2-1 Temperature: -40℃ Dwell Time: 16 hrs PASS Salt Mist Test EN 50155 section 12.2.10 (Class ST4) Temperature: 35℃±2℃ Duration: 96 hrs PASS No damage EN45545-2 Fire Test Conditions Hazard Level Test Items Items Standard HL1 HL2 HL3 Oxygen index test EN 45545-2:2013 EN ISO 4589-2:1996 PASS PASS PASS Smoke density test EN 45545-2:2013 EN ISO 5659-2:2006 PASS PASS PASS Smoke toxicity test EN 45545-2:2013 NF X70-100:2006 PASS PASS PASS R24 Oxygen index test EN 45545-2:2013 EN ISO 4589-2:1996 PASS PASS PASS R25 Glow-wire test EN 45545-2:2013 EN 60695-2-11:2000 PASS PASS PASS R26 Vertical flame test EN 45545-2:2013 EN 60695-11:2003 PASS PASS PASS R22 File Name:RSD-60-SPEC 2022-09-20 RSD-60 60W Reliable Railway DC-DC Converter Mechanical Specification Case No.255 series Unit:mm 128 4 4 120 I/P 60 2 52 1 O/P 2 9.5 1 7.5 9.5 LED 3 4 -ψ 25 3.5 7 tc 51 tc : Max. Case Temperature Input Terminal Pin No. Assignment : Pin No. 1 2 3 Assignment DC INPUT V+ DC INPUT VFG Output Terminal Pin No. Assignment : Pin No. 1 2 Assignment DC OUTPUT -V DC OUTPUT +V Installation Manual Please refer to : http://www.meanwell.com/manual.html File Name:RSD-60-SPEC 2022-09-20
RSD-60G-24 价格&库存

很抱歉,暂时无法提供与“RSD-60G-24”相匹配的价格&库存,您可以联系我们找货

免费人工找货
RSD-60G-24
    •  国内价格
    • 1+306.51174

    库存:3

    RSD-60G-24
      •  国内价格
      • 5+225.50000

      库存:50

      RSD-60G-24
      •  国内价格
      • 1+321.10579
      • 5+314.35196
      • 10+304.72243
      • 25+295.40680
      • 50+288.98711

      库存:115