60W Reliable Railway DC-DC Converter
RSD-60
series
User’s Manual
UL62368-1
AS/NZS62368-1 TPTC004
IEC62368-1
■ Features
Compliance to BS EN/EN50155 and BS EN/EN45545-2
railway standard
Ultra compact and 1U low profile(25mm)
4:1 wide input range
No minimum load required
Protections: Short circuit / Overload / Over voltage /
■ Applications
Bus,tram,metro or railway system
Highly vibrating, highly dusty, extremely
low or high temperature harsh environment
Wireless network
Telecom or datacom system
Industry control system
Input reverse polarity
4000VDC I/O isolation (Reinforced isolation)
Half encapsulated , cooling by free air convection
-40~+70℃ wide working temperature
Built-in constant current limiting circuit
LED indicator for power on
3 years warranty
■ GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
■ Description
RSD-60 is a 60W enclosed type DC-DC reliable railway converter. This series is compliant with BS EN/EN50155/
IEC60571 railway standard, constituting three types of models with 4:1 wide but different input ranges
9~36V/18~72V/40~160V, suitable for railway and all kinds of transportation systems exploiting the frequently
used standard input voltages such as 12V, 24V, 36V, 48V, 72V, 96V and 110V. Various output voltages,
3.3V, 5V, 12V and 24V are available for selection.
This series has the capability of working under -40~+70℃, low ripple and noise, supreme EMC characteristics,
4KVDC I/P-OP, low enclosure profile 25mm and an interior with semi-potted silicone. It does not only well
fits the in-car systems or the facilities by rails for railway, trams and buses but also can be used in the harsh
environment with high vibration, high dust, extremely low or high temperature, etc.
■ Model Encoding
RSD - 60 G - 5
Output voltage (3.3/5/12/24Vdc)
Input voltage (G: 9~36Vdc, L: 18~72Vdc, H: 40~160Vdc)
Rated wattage
Series name
File Name:RSD-60-SPEC 2022-09-20
RSD-60
60W Reliable Railway DC-DC Converter
series
SPECIFICATION
RSD-60G-3.3
RSD-60G-5
RSD-60G-12
RSD-60G-24
RSD-60L-3.3
RSD-60L-5
RSD-60L-12
RSD-60L-24
DC VOLTAGE
3.3V
5V
12V
24V
3.3V
5V
12V
24V
RATED CURRENT
12A
12A
5A
2.5A
12A
12A
5A
2.5A
CURRENT RANGE
RATED POWER
0 ~ 12A
39.6W
0 ~ 12A
60W
0 ~ 5A
60W
0 ~ 2.5A
60W
0 ~ 12A
39.6W
0 ~ 12A
60W
0 ~ 5A
60W
0 ~ 2.5A
60W
RIPPLE & NOISE (max.) Note.2 60mVp-p
100mVp-p
50mVp-p
50mVp-p
60mVp-p
60mVp-p
50mVp-p
50mVp-p
VOLTAGE TOLERANCE Note.3 ±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
LINE REGULATION
±0.5%
±0.5%
±0.3%
±0.2%
±0.5%
±0.5%
±0.3%
±0.2%
LOAD REGULATION
±0.5%
±0.5%
±0.3%
±0.2%
±0.5%
±0.5%
±0.3%
±0.2%
SETUP, RISE TIME
100ms, 60ms at full load
HOLD UP TIME (Typ.)
Please refer to page 5 Hold up Time( Load de-rating curve )
88.5%
89%
93%
91.5%
0.95A/48VDC
1.5A/48VDC
MODEL
OUTPUT
VOLTAGE RANGE CONTINUOUS 9 ~ 36VDC
INPUT
18 ~ 72VDC
EFFICIENCY (Typ.)
86.5%
88%
DC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
2.1A/24VDC
3A/24VDC
92%
90%
20A/48VDC
20A/24VDC
EN50155:2007-G type comply with S1 level(3ms) @ full load,S2 level(10ms) @50% load ; L type comply with S2 level ( 10 ms ) @ full load
INTERRUPTION OF VOLTAGE SUPPLY
EN50155:2017-Comply with S1 level
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP.
TEMP. COEFFICIENT
VIBRATION
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
4.3 ~ 5.3V
5.75 ~ 7V
13.8 ~ 16.2V
27.6 ~ 32.4V
4.3 ~ 4.95V
5.75 ~ 7V
13.8 ~ 16.2V
27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +55℃ (no derating) ; +70℃ @ 60% load by free air convection ; +70℃ (no derating with external base plate)
5 ~ 95% RH non-condensing
-40 ~ +85℃
±0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
OPERATING ALTITUDE
5000 meters
SAFETY STANDARDS
WITHSTAND VOLTAGE
IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Parameter
Standard
I/P-O/P:4KVDC
I/P-FG:2.5KVDC
Conducted
Radiated
O/P-FG:2.5KVDC
Test Level / Note
Harmonic Current
BS EN/EN55032
BS EN/EN55032
BS EN/EN61000-3-2
SAFETY &
Voltage Flicker
BS EN/EN61000-3-3
-----
EMC
BS EN/EN55035
(Note 4)
Parameter
ESD
Standard
BS EN/EN61000-4-2
Test Level / Note
Level 3, ±8KV air ; Level 3, ±6KV contact
Radiated Field
BS EN/EN61000-4-3
Level X, 20V/m
EFT / Burst
BS EN/EN61000-4-4
Surge
BS EN/EN61000-4-5
Level 3,1KV Line-Line, Level 3, 2KV Line-Earth
Conducted
BS EN/EN61000-4-6
Level 3
EMC EMISSION
EMC IMMUNITY
RAILWAY STANDARD
MTBF
OTHERS
DIMENSION
PACKING
NOTE
Class A
Class B
-----
Level 3, 2KV at power
Level 4, 2KV at signal
Compliance to BS EN/EN45545-2 for fire protection ; BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration,
BS EN/EN50121-3-2 for EMC
2738.8K hrs min. Telcordia SR-332 (Bellcore) ; 593.9K hrs min.
128*60*25mm (L*W*H)
0.29Kg; 48pcs/14.9Kg/0.75CUFT
MIL-HDBK-217F (25℃)
1. All parameters NOT specially mentioned are measured at 24,48VDC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
5. Strongly recommended that external output capacitance should not exceed 5000uF.
6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
File Name:RSD-60-SPEC 2022-09-20
RSD-60
60W Reliable Railway DC-DC Converter
series
SPECIFICATION
RSD-60H-3.3
RSD-60H-5
RSD-60H-12
RSD-60H-24
DC VOLTAGE
3.3V
5V
12V
24V
RATED CURRENT
12A
12A
5A
2.5A
CURRENT RANGE
RATED POWER
0 ~ 12A
39.6W
0 ~ 12A
60W
0 ~ 5A
60W
0 ~ 2.5A
60W
RIPPLE & NOISE (max.) Note.2 80mVp-p
60mVp-p
50mVp-p
50mVp-p
VOLTAGE TOLERANCE Note.3 ±2.0%
±2.0%
±2.0%
±2.0%
LINE REGULATION
±0.5%
±0.5%
±0.3%
±0.2%
LOAD REGULATION
±0.5%
±0.5%
±0.3%
±0.2%
SETUP, RISE TIME
100ms, 60ms at full load
HOLD UP TIME (Typ.)
Please refer to page 5 Hold up Time( Load de-rating curve )
92.5%
91.5%
MODEL
OUTPUT
VOLTAGE RANGE CONTINUOUS 40 ~ 160VDC
INPUT
EFFICIENCY (Typ.)
87.5%
89%
DC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.415A/110VDC
0.62A/110V
20A/110VDC
EN50155:2007-H-type comply with S2 level(10ms) @ full load
INTERRUPTION OF VOLTAGE SUPPLY
EN50155:2017-Comply with S1 level
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP.
TEMP. COEFFICIENT
VIBRATION
5.75 ~ 7V
13.8 ~ 16.2V
27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +55℃ (no derating) ; +70℃ @ 60% load by free air convection ; +70℃ (no derating with external base plate)
5 ~ 95% RH non-condensing
-40 ~ +85℃
±0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
5000 meters
SAFETY STANDARDS
WITHSTAND VOLTAGE
IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Parameter
Standard
EMC EMISSION
EMC
(Note 4)
EMC IMMUNITY
RAILWAY STANDARD
MTBF
DIMENSION
PACKING
NOTE
4.3 ~ 4.95V
OPERATING ALTITUDE
SAFETY &
OTHERS
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
I/P-O/P:4KVDC
I/P-FG:2.5KVDC
O/P-FG:2.5KVDC
Test Level / Note
Conducted
Radiated
Harmonic Current
BS EN/EN55032
Class A
BS EN/EN55032
BS EN/EN61000-3-2
Voltage Flicker
BS EN/EN61000-3-3
Class B
---------
BS EN/EN55035
Parameter
ESD
Standard
BS EN/EN61000-4-2
Test Level / Note
Level 3, ±8KV air ; Level 3, ±6KV contact
Radiated Field
BS EN/EN61000-4-3
EFT / Burst
BS EN/EN61000-4-4
Level X, 20V/m
Level 3, 2KV at power
Surge
BS EN/EN61000-4-5
Level 3,1KV Line-Line, Level 3, 2KV Line-Earth
Conducted
BS EN/EN61000-4-6
Level 3
Level 4, 2KV at signal
Compliance to BS EN/EN45545-2 for fire protection ; BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration,
BS EN/EN50121-3-2 for EMC
2738.8K hrs min. Telcordia SR-332 (Bellcore) ; 593.9K hrs min.
128*60*25mm (L*W*H)
0.29Kg; 48pcs/14.9Kg/0.75CUFT
MIL-HDBK-217F (25℃)
1. All parameters NOT specially mentioned are measured at 110VDC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
5. Strongly recommended that external output capacitance should not exceed 5000uF.
6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
File Name:RSD-60-SPEC 2022-09-20
RSD-60
60W Reliable Railway DC-DC Converter
series
Block Diagram
fosc : 130KHz
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
FG
DETECTION
CIRCUIT
PWM
CONTROL
O.L.P.
+V
-V
O.V.P.
Input Fuse
There is one fuse connected in series to the positive input line, which is used to protect against abnormal surge. Fuse specifications of each
model are shown as below.
Type
Fuse Type
Reference and Rating
G
Time-Lag
CONQUE MST, 10A, 250V
L
Time-Lag
CONQUE MST, 5A, 250V
H
Time-Lag
CONQUE MST, 2.5A, 250V
Input Reverse Polarity Protection
There is a MOSFET connected in series to the negative input line. If the input polarity is connected reversely, the MOSFET opens and there
will be no output to protect the unit.
Input Range and Transient Ability
The series has a wide range input capability. With ±40% of rated input voltage, it can withstand that for 1 second.
Input Under-Voltage Protection
If input voltage drops below Vimin, the internal control IC shuts down and there is no output voltage. It recovers automatically when input
voltage reaches above Vimin,please refer to the cruve below.
RSD-60G-24
Vo
RSD-60L-24
30
Vo
25
25
20
20
15
Turn On
Turn Off
10
5
RSD-60H-24
30
Vo
25
20
15
Turn On
Turn Off
10
6
8.3
8
10
12
14
16
Vin
15
Turn On
Turn Off
10
5
5
6.3
0
30
12.3
0
12
16.3
16
20
24
28
32
Vin
25.5
0
24
37
32
40
48
56
Vin
Inrush Current
Inrush current is suppressed by a resistor during the initial start-up, and then the resistor is bypassed by a MOSFET to reduce power
consumption after accomplishing the start-up.
File Name:RSD-60-SPEC 2022-09-20
RSD-60
60W Reliable Railway DC-DC Converter
series
Hold-up Time
En50155: 2007 version - L/H type is in compliance with S2 level (10ms), while G types are in compliance with S1 level (3ms) at full load output
condition. To fulfil the requirements of S2 level (10ms), G types require de-rating their output load to 50%, please refer to
the curve diagrams below.
LOAD
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
RSD-60G-5
LOAD
RSD-60G-3.3
0ms
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms
0ms
10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms
TIME
TIME
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
RSD-60G-24
LOAD
LOAD
RSD-60G-12
0ms
10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms
TIME
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
0ms
10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms
TIME
EN50155: 2017 version - Comply with S1 level (3ms)
Output Voltage Adjustment
This function is optional, which the standard product does not have it. If you do need the function, please contact MW for details.
File Name:RSD-60-SPEC 2022-09-20
RSD-60
60W Reliable Railway DC-DC Converter
series
Efficiency vs Load & Vin Curve
The efficiency vs load & Vin curves of each model are shown as below.
RSD-60G-5
RSD-60G-12
96%
92%
92%
92%
88%
88%
84%
80%
36VDC
76%
24VDC
9VDC
72%
68%
84%
80%
36VDC
76%
24VDC
9VDC
72%
10%
20%
30%
40%
50%
60%
70%
80%
90%
10%
20%
30%
40%
RSD-60G-24
36VDC
76%
24VDC
50%
60%
70%
80%
90%
10%
100%
RSD-60L-3.3
92%
92%
88%
88%
84%
80%
36VDC
76%
24VDC
9VDC
72%
84%
80%
72VDC
76%
48VDC
18VDC
72%
EFFICIENCY
92%
80%
90%
10%
100%
20%
30%
40%
50%
60%
70%
80%
90%
100%
RSD-60L-24
92%
88%
80%
72VDC
76%
48VDC
18VDC
72%
84%
80%
72VDC
76%
48VDC
18VDC
72%
EFFICIENCY
92%
88%
EFFICIENCY
92%
50%
60%
70%
80%
90%
10%
100%
20%
30%
40%
50%
60%
70%
80%
90%
100%
160VDC
110VDC
40VDC
10%
40VDC
72%
68%
88%
84%
80%
160VDC
76%
110VDC
40VDC
72%
30%
40%
50%
40%
60%
70%
80%
90%
60%
70%
80%
90% 100%
88%
84%
80%
160VDC
76%
110VDC
40VDC
72%
64%
64%
100%
50%
68%
68%
64%
EFFICIENCY
110VDC
EFFICIENCY
92%
20%
30%
RSD-60H-24
96%
10%
20%
LOAD
RSD-60H-12
76%
100%
72%
92%
160VDC
90%
76%
96%
80%
80%
80%
92%
84%
70%
84%
96%
88%
60%
88%
LOAD
LOAD
RSD-60H-5
50%
64%
64%
64%
40%
40%
68%
68%
68%
30%
30%
RSD-60H-3.3
96%
20%
20%
LOAD
96%
10%
18VDC
10%
96%
84%
100%
48VDC
LOAD
RSD-60L-12
90%
72%
64%
70%
80%
72VDC
68%
60%
70%
76%
64%
LOAD
60%
80%
68%
50%
50%
84%
64%
40%
40%
88%
68%
30%
30%
RSD-60L-5
96%
20%
20%
LOAD
96%
10%
9VDC
72%
96%
EFFICIENCY
EFFICIENCY
80%
LOAD
LOAD
EFFICIENCY
84%
64%
64%
100%
88%
68%
68%
64%
EFFICIENCY
EFFICIENCY
96%
EFFICIENCY
EFFICIENCY
RSD-60G-3.3
96%
10%
20%
30%
40%
50%
60%
LOAD
LOAD
70%
80%
90%
100%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
LOAD
Parallel and Series Connection
A.Operation in Parallel
Since RSD-60 series don't have built-in parallel circuit, it can only use external circuits to achieve the redundant operation but not increase the current rating.
1.Add a diode at the positive-output of each power supply (as shown as below), the current rating of the diode should be larger than the maximum output current rating
and attached to a suitable heat sink. This is only for redundant use (increase the reliability of the system) and users have to check suitability of the circuit by themselves.
+
I/P
E IN
D1
PS1
I/P
RL
+
I/P
D2
PS2
I/P
-
2.When using S.P.S. in parallel connection, the leakage current will increase at the same time. This could pose as a shock hazard for the user. So please contact the
supplier if you have this kind of application.
B.Operation in Series
RSD-60 can be operated in series. Here are the methods of doing it:
1.Positive and negative terminals are connected as shown as below. According to the connection, you can get the positive and negative output voltages for your loads.
+
I/P
PS1
E IN
+V
RL
I/P
-
I/P
+
COM
PS2
I/P
RL
-
-V
File Name:RSD-60-SPEC 2022-09-20
RSD-60
60W Reliable Railway DC-DC Converter
series
2.Increase the output voltage (current does not change). Because RSD-60 series have no reverse blocking diode in the unit, you should add an external blocking diode
to prevent the damage of every unit while starting up. The voltage rating of the external diode should be larger than V1+V2 (as shown as below).
+V
+
I/P
E IN
PS1
V1
I/P
-
I/P
+
D1
V1+V2 R L
PS2
V2
I/P
D2
-
-V
Overload Protection
If the output draw up to 105~135% of its output power rating, the converter will go into overload protection which is constant current mode. After the faulty condition
is removed, it will recover automatically. Please refer to the diagram below for the detail operation characteristic. Please note that it's not suitable to operate within
the overload region continuously, or it may cause to over temperature and reduce the life of the power supply unit or even damage it.
Vo(%)
100
Overload
region
50
0
50
100
Io(%)
150
Over Voltage Protection
The converter shuts off to protect itself when the output voltage drawn exceeds 115~140% of its output rating. It must be repowered on to recover.
LED Indicator
Equipped with a built-in LED indicator, the converter provides an easy way for users to check its condition through the LED indicator.
Green : normal operation; No signal: no power or failure.
Derating Curve
a.Single unit operation
If the unit has no iron plate mounted on its bottom, the maximum ambient temperature for the unit will be 55℃ as operating under full load condition. It requires
de-rating output current when ambient temperature is between 55~70℃, please refer to the de-rating curve as below.
(Others)
100
100
90
80
(G/L/H 5V)
80
70
40
60
G:Vin ≥ 24V
L:Vin ≥ 48V
H:Vin ≥ 110V
LOAD (%)
LOAD (%)
60
20
-40 -35
0
10
20
30
40
50 55 60
AMBIENT TEMPERATURE (℃ )
70 (HORIZONTAL)
50
40
20
G:9V
L:18V
G:40V
18V
36V
80V
(HORIZONTAL)
INPUT VOLTAGE (VDC)
File Name:RSD-60-SPEC 2022-09-20
RSD-60
60W Reliable Railway DC-DC Converter
series
RATED CURRENT (%)
100
80
60
40
20
-30
0
10
20
30
40
50
60
70
80
(HORIZONTAL)
Tcase (℃)
Suitable installation methods are shown as below. Since RSD-60 is a semi-potted model, its thermal performances for the following installation methods are similar
and share the same derating curve.
b.Operate with additional iron plate
If it is necessary to fulfil the requirements of EN50155 TX level that operate the unit fully-loaded at 70℃, RSD-60 series must be installed onto an iron plate on
the bottom. The size of the suggested iron plate is shown as below. In order for optimal thermal performance, the iron plate must have an even & smooth surface
and RSD-60 series must be firmly mounted at the center of the iron plate.
Unit:mm
M3*4
0
2
36
360
The load vs ambient temperature curve is shown as below.
100
80
LOAD (%)
60
40
20
-40
0
10
20
30
40
50
60
70
(HORIZONTAL)
AMBIENT TEMPERATURE (℃ )
File Name:RSD-60-SPEC 2022-09-20
60W Reliable Railway DC-DC Converter
RSD-60
series
Suitable installation methods are shown as below. Since RSD-60 is a semi-potted model, its thermal performances for the following installation methods are similar
and share the same derating curve.
iron plate
Immunity to Environmental Conditions
Standard
Test method
Test conditions
Status
Cooling Test
EN 50155 section 12.2.3 (Column 2, Class TX)
EN 60068-2-1
Temperature: -40℃
Dwell Time: 2 hrs/cycle
Dry Heat Test
EN 50155 section 12.2.4 (Column 2, Class TX)
EN 50155 section 12.2.4 (Column 3, Class TX & Column 4, Class TX)
EN 60068-2-2
Temperature: 70℃ / 85℃
Duration: 6 hrs / 10min
PASS
Damp Heat Test, Cyclic
EN 50155 section 12.2.5
EN 60068-2-30
Temperature: 25℃~55℃
Humidity: 90%~100% RH
Duration: 48 hrs
PASS
Vibration Test
EN 50155 section 12.2.11
EN 61373
Temperature: 19℃
Humidity: 65%
Duration: 10 mins
PASS
Increased Vibration Test
EN 50155 section 12.2.11
EN 61373
Temperature: 19℃
Humidity: 65%
Duration: 5 hrs
PASS
Shock Test
EN 50155 section 12.2.11
EN 61373
Temperature: 21± 3℃
Humidity: 65 ± 5%
Duration: 30ms*18
PASS
Low Temperature Storage Test
EN 50155 section 12.2.3 (Column 2, Class TX)
EN 60068-2-1
Temperature: -40℃
Dwell Time: 16 hrs
PASS
Salt Mist Test
EN 50155 section 12.2.10 (Class ST4)
Temperature: 35℃±2℃
Duration: 96 hrs
PASS
No damage
EN45545-2 Fire Test Conditions
Hazard Level
Test Items
Items
Standard
HL1
HL2
HL3
Oxygen index test
EN 45545-2:2013
EN ISO 4589-2:1996
PASS
PASS
PASS
Smoke density test
EN 45545-2:2013
EN ISO 5659-2:2006
PASS
PASS
PASS
Smoke toxicity test
EN 45545-2:2013
NF X70-100:2006
PASS
PASS
PASS
R24
Oxygen index test
EN 45545-2:2013
EN ISO 4589-2:1996
PASS
PASS
PASS
R25
Glow-wire test
EN 45545-2:2013
EN 60695-2-11:2000
PASS
PASS
PASS
R26
Vertical flame test
EN 45545-2:2013
EN 60695-11:2003
PASS
PASS
PASS
R22
File Name:RSD-60-SPEC 2022-09-20
RSD-60
60W Reliable Railway DC-DC Converter
Mechanical Specification
Case No.255
series
Unit:mm
128
4
4
120
I/P
60
2
52
1
O/P
2
9.5
1
7.5
9.5
LED
3
4 -ψ
25
3.5
7
tc
51
tc
: Max. Case Temperature
Input Terminal Pin No. Assignment :
Pin No.
1
2
3
Assignment
DC INPUT V+
DC INPUT VFG
Output Terminal Pin No. Assignment :
Pin No.
1
2
Assignment
DC OUTPUT -V
DC OUTPUT +V
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
File Name:RSD-60-SPEC 2022-09-20