1W DC-DC Unregulated Single Output Converter
Features :
1000VDC I/O isolation Internal SMD technology Protection: Short circuit Cooling by free air convection Non-conductive plastic case SMD package styles 100% full load burn-in test Low cost / High reliability Approved: UL / CUL 1 year warranty
SBT01
series
SPECIFICATION
ORDER NO. DC OUTPUT VOLTAGE OUTPUT CURRENT RANGE EFFICIENCY RATED POWER OUTPUT SBT01L-05 5V 0 ~ 200mA 70% 1W 72% SBT01M-05 SBT01L-09 9V 0 ~ 111mA 74% 75% SBT01M-09 SBT01L-12 12V 0 ~ 84mA 74% 75% SBT01M-12 SBT01L-15 15V 0 ~ 67mA 75% 75% SBT01M-15
RIPPLE & NOISE (max.) Note.2 100mVp-p LINE REGULATION Note.3 1.2% for 1% input variation LOAD REGULATION Note.4 8.0% VOLTAGE TOLERANCE VOLTAGE RANGE NORMAL VOLTAGE 8.0% SWITCHING FREQUENCY(Typ.) 100KHz 4.5 ~ 5.5V 5V Full load 292mA No load 29mA Momentary Protection type : Broken Momentary Protection type : Broken -40 ~ +85 -40 ~ +105 (Refer to output load derating curve) , 10 ~ 95% RH 20% ~ 90% RH non-condensing 0.03% / (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes UL60950-1, CSA C22.2 I/P-O/P:1KVDC I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH 10.8 ~ 13.2V 12V 120mA 15mA 4.5 ~ 5.5V 5V 292mA 29mA 10.8 ~ 13.2V 12V 120mA 15mA 4.5 ~ 5.5V 5V 292mA 29mA 10.8 ~ 13.2V 12V 120mA 15mA 4.5 ~ 5.5V 5V 292mA 29mA 10.8 ~ 13.2V 12V 120mA 15mA
INPUT
INPUT CURRENT PROTECTION OVERLOAD
Fuse recommended
PROTECTION SHORT CIRCUIT WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE MTBF OTHERS DIMENSION WEIGHT
500khrs min. MIL-HDBK-217F(25 ) 12.7*7.5*6.0mm or 0.50"*0.30"*0.24" inch (L*W*H) 1.3g
Mechanical Specification
12.7 7.62
8 7 6 5
Unit: mm (inch)
Pin Configuration
Pin No.
1 2 3 4 5 6 7 8
Derating Curve
Output
-Vin +Vin NC -Vout +Vout NC NC NC
100
LOAD (%)
80
11.2 MAX
7.50
6.25
TOP VIEW
1 2 3 4
6.00
2.54 0.5
0.25
2.54
4.13
-40
0
25
50 70 85
100
Ta (
)
NOTE
1.All parameters are specified at normal input, rated load, 25 70% RH ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Line regulation is measured from low line to high line at rated load. 4.Load regulation is measured from 20% to 100% rated load.
File Name: SBT01-SPEC 2008-05-08
很抱歉,暂时无法提供与“SBT01M-12”相匹配的价格&库存,您可以联系我们找货