6W DIP Package DC-DC Regulated Converter
■ Features
DIP24 package with industry standard pinout
2:1 wide input range
Operating temperature range -40 ~ +90℃
No minimum load required
Comply to EN55032 radiated Class A without additional
components
High efficiency up to 87%
Protections: Short circuit (Continuous) / Overload /
Input under voltage
3KVDC I/O isolation
3 years warranty
SCWN06 & DCWN06 series
■ Applications
Telecom/ datacom system
Wireless network
Industrial control facility
Instrument
Analyzer
Detector
Data switch
■ Description
SCWN06 and DCWN06 series are 6W isolated and regulated module type DC-DC converter with DIP24
package. It features international standard pins, a high efficiency up to 87%, wide working temperature
range -40~+ 90℃, 3 KVDC I/P-O/P isolation voltage, Compliance to EN55032 radiated Class A without
additional components, continuous-mode short circuit protection, etc. The additional components, models
account for different input voltage 9~18V, 18~36V and 36~72V 2:1 wide input range, and various output
voltage, 3.3V/5V/12V/15V for single output and ±5V/±12V/±15V for dual outputs, which are suitable for all
kinds of systems, such as industrial control, telecommunication field, distributed power architecture, and
so on.
■ Model Encoding
S CWN06 A - 12
Output voltage (3.3/5/12/15Vdc, ±5/±12/±15Vdc)
Input voltage (A: 9~18Vdc,B: 18~36Vdc,C: 36~72Vdc)
Rated wattage
Series name
output
{ S:Single
D:Dual output
File Name:SCWN06,DCWN06-SPEC 2018-03-01
6W DIP Package DC-DC Regulated Converter
SCWN06 & DCWN06 series
MODEL SELECTION TABLE
INPUT
ORDER NO.
INPUT VOLTAGE
(RANGE)
OUTPUT
INPUT CURRENT
OUTPUT
VOLTAGE
OUTPUT
CURRENT
EFFICIENCY
(TYP.)
CAPACITOR LOAD
(MAX.)
NO LOAD
FULL LOAD
SCWN06A-03
5mA
429mA
3.3V
1200mA
77%
4700μF
SCWN06A-05
5mA
514mA
5V
1000mA
81%
4700μF
SCWN06A-12
10mA
600mA
12V
500mA
83%
4700μF
15mA
600mA
15V
400mA
84%
4700μF
DCWN06A-05
10mA
514mA
±5V
±0 ~ 500mA
80%
*2200μF
DCWN06A-12
12mA
600mA
±12V
±0 ~ 250mA
83%
*2200μF
DCWN06A-15
18mA
600mA
±15V
±0 ~ 200mA
84%
*2200μF
SCWN06B-03
4mA
209mA
3.3V
1200mA
79%
4700μF
SCWN06B-05
5mA
251mA
5V
1000mA
82%
4700μF
SCWN06B-12
7mA
291mA
12V
500mA
86%
4700μF
8mA
291mA
15V
400mA
86%
4700μF
DCWN06B-05
8mA
254mA
±5V
±0 ~ 500mA
82%
*2200μF
DCWN06B-12
10mA
291mA
±12V
±0 ~ 250mA
86%
*2200μF
DCWN06B-15
10mA
291mA
±15V
±0 ~ 200mA
85%
*2200μF
SCWN06C-03
2mA
104mA
3.3V
1200mA
79%
4700μF
SCWN06C-05
3mA
126mA
5V
1000mA
83%
4700μF
SCWN06C-12
6mA
148mA
12V
500mA
86%
4700μF
5mA
148mA
15V
400mA
86%
4700μF
DCWN06C-05
8mA
126mA
±5V
±0 ~ 500mA
83%
*2200μF
DCWN06C-12
8mA
148mA
±12V
±0 ~ 250mA
85%
*2200μF
DCWN06C-15
10mA
144mA
±15V
±0 ~ 200mA
87%
*2200μF
SCWN06A-15
SCWN06B-15
SCWN06C-15
Normal 12V
(9 ~ 18V)
Normal 24V
(18 ~ 36V)
Normal 48V
(36 ~ 72V)
* For each output
File Name:SCWN06,DCWN06-SPEC 2018-03-01
SCWN06 & DCWN06 series
6W DIP Package DC-DC Regulated Converter
SPECIFICATION
VOLTAGE RANGE
A: 9~18Vdc , B: 18~36Vdc , C: 36~72Vdc
SURGE VOLTAGE (100ms max.) 12Vin models : 25Vdc ; 24Vin models : 50Vdc ; 48Vin models : 100Vdc
INPUT
FILTER
Pi type
PROTECTION (Typ.)
Fuse recommended. 12Vin models: 1.6A Fast-Acting Type, 24Vin models: 1A Fast-Acting Type, 48Vin models: 0.5A Fast-Acting Type
INTERNAL POWER DISSIPATION 500mW
OUTPUT
VOLTAGE ACCURACY
±1.5%
RATED POWER
6W
RIPPLE & NOISE
Note.2 50mVp-p
LINE REGULATION Note.3 ±0.5%
LOAD REGULATION Note.4 Single output models:±0.5%, Dual output models:±1%
SWITCHING FREQUENCY (Min.) 100KHz
SHORT CIRCUIT
PROTECTION
OVERLOAD
UNDER VOLTAGE LOCKOUT
ENVIRONMENT
Protection type : Continuous, automatic recovery
120 ~ 250% rated output power
Protection type : Recovers automatically after fault condition is removed
Start-up voltage
12Vin: 8.8Vdc, 24Vin: 17Vdc, 48Vin: 34Vdc
Shutdown voltage
12Vin: 8Vdc,
COOLING
Free-air convection
WORKING TEMP.
-40 ~ +90℃ (Refer to "Derating Curve")
CASE TEMPERATURE
+100℃ max.
WORKING HUMIDITY
20% ~ 90% RH non-condensing
24Vin: 16Vdc, 48Vin: 31Vdc
STORAGE TEMP., HUMIDITY -40 ~ +100℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
0.03% / ℃ (0 ~ 90℃)
SOLDERING TEMPERATURE 1.5mm from case of 1 ~ 3sec./260℃ max.
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVDC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
ISOLATION CAPACITANCE (Typ.) 250pF
EMC EMISSION
SAFETY &
EMC
( Note.5)
EMC IMMUNITY
OTHERS
NOTE
Parameter
Standard
Test Level / Note
Conducted
EN55032(CISPR32)
N/A
Radiated
EN55032(CISPR32)
Class A
Parameter
Standard
Test Level / Note
ESD
EN61000-4-2
Level 2, ±8KV air, ±4KV contact
Radiated Susceptibility
EN61000-4-3
Level 2, 3V/m
EFT/Burest
EN61000-4-4
Level 1, 0.5KV
Surge
EN61000-4-5
Level 1, 0.5KV Line-Line
Conducted
EN61000-4-6
Level 2, 3V(e.m.f.)
Magnetic Field
EN61000-4-8
Level 2, 3A/m
MTBF (Typ.)
1800Khrs MIL-HDBK-217F(25℃)
DIMENSION (L*W*H)
31.8*20.3*10.2mm (1.25*0.8*0.4 inch)
CASE MATERIAL
Non-Conductive black plastic (UL 94V-0 rated)
PACKING
12.5g
1.All parameters are specified at normal input(A:12Vdc, B:24Vdc, C:48Vdc), rated load, 25℃ 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100% rated load for SCWN06, 25% to 100% rated load for DCWN06.
5.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please
refer to EMI testing of component power supplies.(as available on http://www.meanwell.com)
File Name:SCWN06,DCWN06-SPEC 2018-03-01
SCWN06 & DCWN06 series
6W DIP Package DC-DC Regulated Converter
Mechanical Specification
2.54(0.1)
All dimensions in mm(inch)
Tolerance:x.x±0.5mm( x.xx±0.02")
x.xx±0.25mm( x.xxx±0.010")
Pin size is:0.5±0.05mm (0.02 "±0.002")
23
22
2
3
31.8(1.25)
0.5(0.02")
Side View
16
9
14
11
5.08(0.2)
Bottom View
15.24(0.6)
3.8(0.15)
20.3(0.8)
10.2(0.4)
Derating Curve
Plug Assignment
Pin-Out
SCWN06
(Single output)
DCWN06
(Dual output)
2,3
-Vin
-Vin
9
N.C.
Common
11
N.C.
-Vout
14
+Vout
+Vout
16
-Vout
Common
22,23
+Vin
+Vin
100
LOAD (%)
Pin No.
80
50
Natural convection
40
20
-40
-20
0
20
40
60
80
90 100
Ta (℃)
Installation Manual
Please refer to : http://www.meanwell.com/manual.html