480W Single Output Industrial DIN RAIL with PFC and Parallel Function
Features :
SDR-480P series
Current sharing up to 3840W(7+1) High efficiency 94% and low power dissipation 150% peak load capability Built-in active PFC function, PF>0.94 Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Built-in constant current limiting circuit Can be installed on DIN rail TS-35/7.5 or 15 UL 508(industrial control equipment)approved EN61000-6-2(EN50082-2) industrial immunity level Built-in DC OK relay contact 100% full load burn-in test 3 years warranty
SE
PQ
M
IF
47
GL
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK CURRENT PEAK POWER Note.6 OUTPUT VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE FUNCTION SDR-480P-24 24V 20A 0 ~ 20A 480W 30A 720W (3sec.) 120mVp-p 48 ~ 55V 1.0% 0.5% 1.0% 3000ms, 150ms/115VAC at full load SDR-480P-48 48V 10A 0 ~ 10A 480W 15A
RIPPLE & NOISE (max.) Note.2 100mVp-p 24 ~ 28V VOLTAGE TOLERANCE Note.3 1.2% 0.5% 1.0% 1500ms, 150ms/230VAC 14ms/230VAC at full load
Note.7 90 ~ 264VAC
127 ~ 370VDC 0.99/115VAC at full load 2.5A/230VAC 80A/230VAC
47 ~ 63Hz 0.94/230VAC 94% 5A/115VAC 40A/115VAC
150% rated power, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 2 seconds 56 ~ 65V 29 ~ 33V Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery 105 5 (TSW : detect on heatsink of power switch) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
DC OK REALY CONTACT RATINGS (max.) 60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load Please see the Function Manual CURRENT SHARING WORKING TEMP. WORKING HUMIDITY
Note.5 -25 ~ +70
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 UL508, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A, SEMI F47, GL approved 112.9Khrs min. MIL-HDBK-217F (25 ) 85.5*125.2*128.5mm (W*H*D) 1.6Kg; 8pcs/13.8Kg/0.9CUFT
ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC
(Note 4)
ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF
OTHERS
NOTE
DIMENSION PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. 6. 3 seconds peak power max. and the average output power should not exceed the rate power. 7. Derating may be needed under low input voltage. Please check the derating curve for more details.
File Name:SDR-480P-SPEC 2011-12-27
480W Single Output Industrial DIN RAIL with PFC and Parallel Function
Mechanical Specification
SDR-480P series
Case No.984A Unit:mm
125.2
TB2 1 2 3 4 5 6 7 8
+
85.5
TB1 1 2 3
128.5
+V ADJ DC OK DC OK
Terminal Pin No. Assignment (TB1)
Pin No. 1 2 3 Assignment FG AC/N AC/L
35
Terminal Pin No. Assignment (TB2)
ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15
Pin No. 1,2 3,4 5,6 7 8
Assignment DC OUTPUT +V DC OUTPUT -V Relay Contact P+ (currene share) P- (currene share)
Block Diagram
DC OK
I/P
EMI FILTER & RECTIFIERS
PFC CIRCUIT
POWER SWITCHING
RECTIFIERS & FILTER O.C.P.
+V -V
U.V.P. FG PFC CONTROL
O.L.P. PWM & PFC CONTROL DETECTION CIRCUIT O.V.P.
DC OK Relay Contact
Contact Close Contact Open PSU turns on / DC OK. PSU turns off / DC Fail.
Contact Ratings (max.) 30V/1A resistive load.
F ile Name:SDR-480P-SPEC 2011-12-27
480W Single Output Industrial DIN RAIL with PFC and Parallel Function
Peak Loading
(1) 720W (2) 720W
SDR-480P series
480W 50 sec. 3 sec.
240W 15 sec. 3 sec.
Derating Curve
Output derating VS input voltage
150
100 90
120
For 3 sec. (typ.)
80 70
100
LOAD (%)
LOAD (%)
40 50 60 70 (VERTICAL)
80
Continuous
60 50 40
60
-25
0
10
20
30
90
100
110
135
155
230
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (V) 60Hz
Function Manual
1. Current sharing (1)Parallel operation is available by connecting the units shown as below (P+,P- are connected mutually in parallel) : (2)The voltage difference among each output should be minimized that less than 2% is required. (3)The total output current must not exceed the value determined by the following equation (Output current at parallel operation) =(The rated current per unit) x (Number of unit) x 0.9. (4) In parallel operation 8 units is the maximum, please consult the manufacture for other applications. (5) When in parallel operation, the minimum output load should be greater than 3% of total output load. (Min. load > 3% rated current per unit x number of unit)
+
LOAD
-
+
- DC OK P+ P-
+
- DC OK P+ P-
+
- DC OK P+ P-
+
- DC OK P+ P-
+
- DC OK P+ P-
+
- DC OK P+ P-
+
- DC OK P+ P-
+
- DC OK P+ P-
PSU
PSU
PSU
PSU
PSU
PSU
PSU
PSU
File Name:SDR-480P-SPEC 2011-12-27
很抱歉,暂时无法提供与“SDR-480P_11”相匹配的价格&库存,您可以联系我们找货