40W DC-DC Regulated Single Output Converter
Features :
SKA40
series
SPECIFICATION
ORDER NO. DC VOLTAGE CURRENT RANGE RATED POWER OUTPUT LINE REGULATION LOAD REGULATION VOLTAGE ACCURACY SWITCHING FREQUENCY
Note.3 Note.4
2:1 wide input range High efficiency up to 92% 1500VDC I/O isolation Built-in EMI filter Built-in remote ON / OFF control Built-in remote sense Trimming ouput 10% Protections: Short circuit / Overload / Over voltage Cooling by free air convection Six-sided shield metal case 100% burn-in test Low cost / High reliability Output 3.3V/9V available Approvals: FCC / CE 2 years warranty
SKA40A-05 SKA40B-05 SKA40C-05 SKA40A-12 SKA40B-12 SKA40C-12 SKA40A-15 SKA40B-15 SKA40C-15 5V 0.7 ~ 7A 35W 0.5% 0.5% 2.0% 200KHz min. 12V 0.3 ~ 3.33A 40W 80mVp-p 15V 0.26 ~ 2.67A 40W 100mVp-p
RIPPLE & NOISE (max.) Note.2 60mVp-p
EXTERNAL CAPACITANCE LOAD (max.) 1000uF EXTERNAL TRIM Adj. RANGE(Typ.) 10% A: 9 ~ 18VDC B: 18 ~ 36VDC C: 36 ~ 75VDC VOLTAGE RANGE 92% 91% 90% 91% EFFICIENCY (Typ.) INPUT DC CURRENT FILTER REMOTE CONTROL PROTECTION OVER CURRENT PROTECTION
(Note. 5)
90%
88.5%
90%
90.5%
90%
Full load No load Pi network
A: 3850mA B: 1900mA A: 150mA B: 100mA
C: 1000mA C: 65mA
Power ON : R.C ~ -Vin > 2.5VDC or open circuit ; Power OFF : R.C ~ -Vin < 0.5VDC or short Fuse recommended 110% ~ 180% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed Protection type : Shut off O/P voltage, clamp by TVS diode -40 ~ +80 (Refer to output load derating curve)
SHORT CIRCUIT OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY
20% ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -55 ~ +105 , 10 ~ 95% RH 0.03% / (0 ~ 50 ) TEMP. COEFFICIENT VIBRATION WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC EMI CONDUCTION & RADIATION EMS IMMUNITY DIMENSION WEIGHT 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes I/P-O/P:1.5KVDC I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 Class A, FCC part 15 Class A Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A 50.8*50.8*11.0 mm or 2"*2"*0.43" inch (L*W*H) 60g
OTHERS
Mechanical Specification
Unit:mm(inch) 50.8 (2.00)
7.62 5.08 7.62 5.08 (0.3) (0.2) (0.3) (0.2)
Pin Configuration
Pin No. Output
1 2 3 4 R.C -Vin +Vin -R.S
Derating Curve
+R.S +Vout -Vout TRIM
Pin No. Output
5 6 7 8
100
3~3.5 (0.12~0.14) 11 (0.43)
4
56
78
50.8 (.200)
45.7 (1.8)
BOTTOM VIEW 32
5.08 (0.2)
External Output Trimming
2 -Vin +Vout 6 7 LOAD VR VR 3 +Vin TRIM 8 UP DOWN 500K
LOAD (%)
50
1
-Vout
10.16 12.7 (0.4) (0.5)
1.0
(0.04 0.005)
-40
0
25
50 60
80
100
Ta (
TRIMPOT
)
NOTE
1.All parameters are specified at normal input, rated load, 25 70% RH ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Line regulation is measured from low line to high line at rated load. 4.Load regulation is measured from 10% to 100% rated load. 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
File Name:SKA40-SPEC 2010-03-31
很抱歉,暂时无法提供与“SKA40”相匹配的价格&库存,您可以联系我们找货