2W DC-DC Regulated Single Output Converter
Features :
2:1 wide input range 4:1 wide input range (Option) 1000VDC I/O isolation 3000VDC I/O isolation (Option) Built-in remote ON/OFF control Built-in EMI filter
S PA 0 2
series
Protections: Short circuit / Overload Cooling by free air convection Single in line package 100% full load burn-in test Low cost / High reliability Modified models available: output 3.3V/9V 2 years warranty
SPECIFICATION
ORDER NO. DC VOLTAGE CURRENT RANGE RATED POWER OUTPUT
SPA02E-05 SPA02A-05 SPA02B-05 SPA02C-05 SPA02E-12 SPA02A-12 SPA02B-12 SPA02C-12 SPA02E-15 SPA02A-15 SPA02B-15 SPA02C-15
5V 40 ~ 400mA 2W
12V 15 ~ 150mA 17 ~ 167mA 1.8W 60mVp-p 2W
15V 12 ~ 120mA 13 ~ 133mA 1.8W 60mVp-p 2W
RIPPLE & NOISE (max.) Note.2 60mVp-p LINE REGULATION Note.3 0.5% LOAD REGULATION VOLTAGE ACCURACY SWITCHING FREQUENCY VOLTAGE RANGE EFFICIENCY (Typ.)
Note.4
0.5% 2.0% 100KHz min. E: 4.5 ~ 9VDC 71% No load 76% E: 50mA A: 9 ~ 18VDC 76% A: 25mA B: 18 ~ 36VDC 74% 74% C: 36 ~ 72VDC 80% 80% 82% 76% 80% 80% 78%
INPUT
DC CURRENT FILTER PROTECTION OVERLOAD
Full load E: 600mA Pi network Fuse recommended
A: 225mA B: 115mA B: 15mA
C: 60mA C: 8mA
PROTECTION
(Note. 5)
150 ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed -40 ~ +85 (Refer to output load derating curve)
SHORT CIRCUIT WORKING TEMP.
ENVIRONMENT
WORKING HUMIDITY 20% ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY -40 ~ +105 , 10 ~ 95% RH 0.05% / (0 ~ 50 ) TEMP. COEFFICIENT VIBRATION WITHSTAND VOLTAGE ISOLATION RESISTANCE ISOLATION CAPACITANCE 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes I/P-O/P:1KVDC I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH 80pF max.
SAFETY
EMI CONDUCTION & RADIATION Compliance to EN55022 Class B, FCC part 15 Class B Compliance to EN61000-4-2,3,4,5,6,8 light industry level, criteria A EMS IMMUNITY Power ON : R.C. ~ +Vin < 1VDC or open ; Power OFF : R.C. ~ +Vin > 4VDC or short REMOTE CONTROL OTHERS MTBF DIMENSION WEIGHT 600Khrs min. MIL-HDBK-217F(25 ) 21.8*9.2*11.1mm or 0.86"*0.36"*0.44" inch (L*W*H) 4.8g
Mechanical Specification
21.8(0.86)
11.1(0.44)
Pin Configuration
Unit:mm(inch)
Derating Curve
FRONT VIEW 123 0.5 0.05(0.02) 5.08 (0.2) 5678
0.5 (0.02)
Pin No.
1 2 3 5 6 7 8
Output
- Vi n + Vi n R.C. N.C. + Vo u t - Vo u t N.C.
100
3.81 0.5(0.15)
2.54(0.1)
LOAD (%)
17.78(0.7)
50
BOTTOM VIEW 3.2(0.13) 2.01(0.08)
9.2(0.36)
-40
0
25
50 70 85
100
Ta (
NOTE 1.All parameters are specified at normal input, rated load, 25 70% RH ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Line regulation is measured from low line to high line at rated load. 4.Load regulation is measured from 10% to 100% rated load. 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
)
File Name:SPA02-SPEC 2011-03-08
很抱歉,暂时无法提供与“SPA02_11”相匹配的价格&库存,您可以联系我们找货