J2R0015-41-31
REED SWITCH
ORD9216
General Purpose Miniature
n GENERAL DESCRIPTION The ORD9216 is a small single-contact reed switch designed for general control of mediumlevel loads less than 100 V. The contacts are sealed within the glass tube with inert gas to maintain contact reliability. n FEATURES (1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive any influence from the external atmospheric environment. (2) Quick response (3) The structure comprises the operating parts and electrical circuits arranged coaxially. Reed switches are suited to applications in radio frequency operation. (4) Reed switches are compact and light weight. (5) Superior corrosion resistance and wear resistance of the contacts assures stable switching operation and long life. (6) With a permanent magnet installed, reed switches economically and easily become proximity switches. n EXTERNAL DIMENSIONS (Unit: mm)
f0.5 MAX f2.2
MAX 14.0
44.3±0.5
n APPLICATIONS l Control equipment l Communication equipment l Measurement equipment l Household appliances
159
l ORD9216
n ELECTRICAL CHARACTERISTICS
Parameter Pull-in Value (PI) Drop-out Value (DO) Contact resistance (CR) Breakdown voltage Insulation resistance Electrostatic capacitance Contact rating Maximum switching voltage Maximum switching current Maximum carry current
Rated value 10∼50 5min 100max 150min 109min 0.3max 10
DC 100( ) AC
Unit AT AT mW V VDC W pF VA V A A
0.5 1.0
(1) Drop-out Value vs. Pull-in Value
(2) Contact resistance
99.9 (Measurement length: 32mm)
Cumulative frequency percent (%)
AT 50
99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 40 60 80 100 mW
Drop-out Value
40
30
20
10
0
10
20
30 Pull-in Value
40
50
AT
Contact resistance
160
ORD9216 l
(3) Breakdown voltage
(4) Insulation resistance
99.9
Cumulative frequency percent (%)
(DC 100V)
99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 10 10
11 12 13 14
DC:V 400 Breakdown voltage
300
200
100
0
10
20
30 Pull-in Value
40
50
AT
10
10
10
10
Insulation resistance
(5) Electrostatic capacitance
(1MHz) pF Electrostatic capacitance 0.4
0.3
0.2
0.1
0
10
20
30 Pull-in Value
40
50
AT
161
l ORD9216
n OPERATING CHARACTERISTICS
Parameter Operate time Bounce time Release time Resonant frequency Maximum operating frequency Rated value 0.4max 0.3max 0.05max 5000±400 500 Unit ms ms ms Hz Hz
(1) Operate time
(25Hz: 100AT energized)
(2) Bounce time
(25Hz: 100AT energized)
99.9
ms 0.5
Cumulative frequency percent
99 95 90 80 70 60 50 40 30 20 10 5 1
0.4 Operate time
0.3
0.2
0.1
0
10
20
30 Pull-in Value
40
50
0.1
AT
0
0.1
0.2
0.3
0.4
ms
Bounce time
(3) Release time
(4) Resonant frequency
99.9
Cumulative frequency percent (%)
99 95 90 80 70 60 50 40 30 20 10 5 1 0.1
(25Hz: 100AT energized) ms 15
Release time
10
5
0
10
20
30
40
50
AT
3400
3700
4000
Hz
Drop-out Value
Resonant frequency
162
ORD9216 l
n MECHANICAL CHARACTERISTICS
(1) Lead tensile test (static load)
(2.27kg-10sec)
(2) Lead tensile strength
99.9
AT 60
Cumulative frequency percent (%)
99 95 90 80 70 60 50 40 30 20 10 5 1 0.1 0 2 4 6 8 10kg Breaking load
Pull-in Value • Drop-out Value
50
40
PI
30
20
DO
10
0 Contact resistance
80
CR
60
40
Before test After test
n ENVIRONMENTAL CHARACTERISTICS
(1) Temperature characteristics
% 40 CR 30
Rate of change percent
20 DO 10 PI 0
−10 −20 −30
−40
−20
0
20
40 Temperature
60
80
100
120
℃
163
l ORD9216
(2) Temperature cycle
(-55℃∼+125 ℃) AT 60 Pull-in Value • Drop-out Value Pull-in Value • Drop-out Value
(3) Temperature and humidity cycle
-10℃∼+65℃ 80%∼98% AT 60
50
50
40
40
30
PI
30
PI
20
DO
20
DO
10
10
0 Contact resistance Contact resistance mW 100
0 mW 100
80
CR
80
CR
60
Before test After test
60
Before test After test
(4) High temperature storage test
(+125℃-500H) AT 60 Pull-in Value • Drop-out Value Pull-in Value • Drop-out Value
(5) Low temperature storage test
(-40℃-500H) AT 60
50
50
40
40
30
PI
30
PI
20
DO
20
DO
10
10
0 Contact resistance Contact resistance mW 100
0 mW 100
80
CR
80
CR
60
Before test After test
60
Before test After test
164
ORD9216 l
(6) Shock test 1) Electrical characteristics
(30G: 11ms) AT 60 Pull-in Value • Drop-out Value
2) Misoperation area
(open→close)
G 1500
50
40
Acceleration
30
PI
1000 Misoperation area
20
DO
10
500
0 Contact resistance mW 100
CR
80
0
10
20
30
40
50
60
AT
Pull-in Value
60
Before test After test
(7) Vibration test
(20G: 10∼1000Hz) AT 60 Pull-in Value • Drop-out Value
50
40
30
PI
20
DO
10
0 Contact resistance mW 100
CR
80
60
Before test After test
165
l ORD9216
n LIFE EXPECTANCY DATA: ORD9216
(%) 99.9 90 70 50 30 10 5
No failure 5mA 1mA 100mA
Load conditions Voltage: 5VDC Current: 100mA 1mA , 5mA Load: Resistive load
Cumulative failure rate
1
0.1 0
23
5 7 105
23
5 7 106
23
5 7 107
23
5 7 108
Number of operations * Arrow indicates number of operations where test was completed.
(%) 99.9 90 70 50 30 10 5
No failure
Load conditions Voltage: 12 VDC Current: 5mA, 10mA, 100mA Load: Resistive load
Cumulative failure rate
100mA
10mA
5mA
1
0.1 0
23
5 7 105
23
5 7 106
23
5 7 107
23
5 7 108
Number of operations * Arrow indicates number of operations where test was completed.
Cumulative failure rate 200mA 100mA
(%) 99.9 90 70 50 30 10 5
400mA 100mA
Load conditions Voltage: 24 VDC Current: 100mA, 200mA, 400mA Load: Resistive load
200mA
1
0.1 0
23
57
23
57
23
57
23
57
Number of operations
166