0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EVB90640-41

EVB90640-41

  • 厂商:

    MELEXIS(迈来芯)

  • 封装:

    -

  • 描述:

    EVB90640-41

  • 数据手册
  • 价格&库存
EVB90640-41 数据手册
EVB90640-41 User manual 1. Installation Before connecting the EVB to the PC, first install the EVB software. The EVB software can be downloaded from the Melexis website: https://www.melexis.com/en/product/EVB90640-41/Evaluation-Board-MLX90640-MLX90641 The EVB90640-41 comes with 2 sensors, 1 MLX90640ESF-BAB and 1 MLX90641ESF-BCB. Mechanically, the parts are identical, but they can be identified by the first number of the marking on the sensors: “0” for the MLX90640, “1” for the MLX90641. Insert the sensor in the ZIF socket on the PCB. Take care to align the notch with the silk screen on the PCB. Next, connect the PCB with the USB port of the computer. The computer should indicate that a new USB device is being installed and indicate after a while it has been installed successfully. This installation normally happens only once. The pwr LED on the PCB should be on. Rev. 3 Page 1 of 1 EVB90640-41 User manual 2. Operation Now start the EVB program. The program will scan for the EVB and you should see a screen as below: The EVB has been recognized and a sensor has been found on the PCB. The EVB detects by itself if MLX90640 or a MLX90641 has been inserted in the ZIF socket. The I2C address of the sensor is shown and its factory ID. The sensor is powered when the EVB starts. If needed, one can turn off the supply voltage by pressing the Vdd button . Now, click on the + in front of the Measure tab. Here one can control by clicking on the item: • The external bilinear interpolation of the thermal image (x1, x2 or x4); • The (sub-)frame rate of the sensor: 0.5Hz, 1Hz, 2Hz, 4Hz … 64Hz. Initially, the software reads the frame rate as set in the EEPROM of the sensor. The factory default is 2Hz; • The emissivity of the object, to be entered by the user. Standard setting E=1; • Enable or disable the external de-interlace filter; • Enable and configure the external IIR small signal filter. There is a value for the depth of the filter (a higher value reduces noise) and a threshold value, which controls at which object temperature jump the filter is reset; Rev. 3 Page 2 of 2 EVB90640-41 User manual • Set the depth of the averaging filter applied on the TGC signal used for thermal gradient compensation on the MLX90641. This has no effect on the MLX90640 as the TGC coefficient is set to 0 for that device. Now double click the measure tab: The measurement starts and the resulting thermal image (below example with MLX90640) is shown in a new screen. Pixel 1 Pixel 32 Pixel 768 In the top right corner one can see the maximum and minimum temperature of the temperature scale, the sensor temperature Ta and the temperature To of the pixel at the pointer location. Note that the button “measure” has changed to “standby”. By clicking this, one can halt the imager. Rev. 3 Page 3 of 3 EVB90640-41 User manual In the Application tab one can control the color range of the visualization. This does NOT influence the actual measurement range. One can also choose the desired temperature unit and mirror the image if needed for presentation purposes. The restart on full EVB assures that the EVB would restart by itself if the memory of the EVB would overflow. In the “Range” tab one can choose between autoscale or set the minimum and maximum temperature manually. Rev. 3 Page 4 of 4 EVB90640-41 User manual In the log tab, one can control where and if the measured data is stored on the PC. The file can also be opened in Excel from here. After measurement of each sub-frame, The data is stored with all measurements of one full frame (768 pixels) in one line. The next frame is stored on the next line. Each line starts with a timestamp, followed by the temperature reading of each individual pixel, row by row. After 768 object temperature readings, follow internal parameters, among which the Ta, which is the sensor temperature. The data that is stored is the measurement data AFTER application of the de-interlacing and IIR filter if selected, but without interpolation. Rev. 3 Page 5 of 5 EVB90640-41 User manual Clicking on the EEPROM tab will show you the EEPROM content. The program also shows what the current EEPROM content means for FPS, resolution setting and sub-frame pattern. This is the configuration the sensor will start in after POR. Under the EEPROM tab there is also a tab to export the EEPROM information to file and a button to upload new firmware to the EVB if needed. Here is also a tab to point the program to the file directory where a special calibration file for a specific sensor is located – if available. 3. ESD Precautions Electronic semiconductor products are sensitive to Electro Static Discharge (ESD). Always observe Electro Static Discharge control procedures whenever handling semiconductor products. Rev. 3 Page 6 of 6 EVB90640-41 User manual 4. Disclaimer The information furnished by Melexis herein (“Information”) is believed to be correct and accurate. Melexis disclaims (i) any and all liability in connection with or arising out of the furnishing, performance or use of the technical data or use of the product(s) as described herein (“Product”) (ii) any and all liability, including without limitation, special, consequential or incidental damages, and (iii) any and all warranties, express, statutory, implied, or by description, including warranties of fitness for particular purpose, noninfringement and merchantability. No obligation or liability shall arise or flow out of Melexis’ rendering of technical or other services. The Information is provided "as is” and Melexis reserves the right to change the Information at any time and without notice. Therefore, before placing orders and/or prior to designing the Product into a system, users or any third party should obtain the latest version of the relevant information to verify that the information being relied upon is current. Users or any third party must further determine the suitability of the Product for its application, including the level of reliability required and determine whether it is fit for a particular purpose. The Information is proprietary and/or confidential information of Melexis and the use thereof or anything described by the Information does not grant, explicitly or implicitly, to any party any patent rights, licenses, or any other intellectual property rights. This document as well as the Product(s) may be subject to export control regulations. Please be aware that export might require a prior authorization from competent authorities. The Product(s) are intended for use in normal commercial applications. Unless otherwise agreed upon in writing, the Product(s) are not designed, authorized or warranted to be suitable in applications requiring extended temperature range and/or unusual environmental requirements. High reliability applications, such as medical life-support or lifesustaining equipment are specifically not recommended by Melexis. The Product(s) may not be used for the following applications subject to export control regulations: the development, production, processing, operation, maintenance, storage, recognition or proliferation of 1) chemical, biological or nuclear weapons, or for the development, production, maintenance or storage of missiles for such weapons: 2) civil firearms, including spare parts or ammunition for such arms; 3) defense related products, or other material for military use or for law enforcement; 4) any applications that, alone or in combination with other goods, substances or organisms could cause serious harm to persons or goods and that can be used as a means of violence in an armed conflict or any similar violent situation. The Products sold by Melexis are subject to the terms and conditions as specified in the Terms of Sale, which can be found at https://www.melexis.com/en/legal/terms-andconditions. This document supersedes and replaces all prior information regarding the Product(s) and/or previous versions of this document. Melexis NV © - No part of this document may be reproduced without the prior written consent of Melexis. (2016) ISO/TS 16949 and ISO14001 Certified Rev. 3 Page 7 of 7
EVB90640-41 价格&库存

很抱歉,暂时无法提供与“EVB90640-41”相匹配的价格&库存,您可以联系我们找货

免费人工找货
EVB90640-41
  •  国内价格
  • 1+1904.12533
  • 5+1866.04262

库存:14