MLX90224EVA-AAA-000-SP 数据手册
MLX90224
Dual Hall Effect Latch
Features and Benefits
Applications
Chopper Stabilized Amplifier Stage
CMOS for Optimum Stability, Quality and
Cost
Dual Outputs
Phase/Direction Detection
Direction Detector
Speed Sensor
Shaft Encoding
Position Sensing
Ordering information
Product Code
MLX90224EVA-AAA-000-BU
Temperature Code
E (-40°C to 85°C)
1. Functional Diagram
Replaced with Logic for
MLX90224 B
2
Chopper
4
Chopper
REVISION 009 – JAN 18
3901090224
The MLX90224 is a dual Hall effect latch. It includes two Hall
effect latch functions of which typical thresholds are +/- 2.0
mT. In each latch, the magnetic flux detection is performed
by a switched silicon Hall plate.
The MLX90224EVA-AAA output transistor will be “latched on”
(BOP) in the presence of a sufficiently strong South pole
magnetic field facing the marked side of the package.
Similarly, the output will be “latched off” (BRP) in the
presence of a North field. Spacing of the Hall plates is 1.85
mm.
The output structure is an Open-Drain NMOS transistor with
a capability of 25 mA and protected against short-circuits.
3
Pin #
1
2
3
4
Packing Form
BU (Bulk)
2. General Description
1
Voltage
Regulator
Package Code
VA
Name
VDD
Out1
GND
Out2
Page 1 of 9
MLX90224
Dual Hall Effect Latch
Contents
Features and Benefits.................................................................................................................................1
Applications................................................................................................................................................1
Ordering information .................................................................................................................................1
1. Functional Diagram ................................................................................................................................1
2. General Description................................................................................................................................1
3. Glossary of Terms ...................................................................................................................................3
4. Absolute Maximum Ratings ....................................................................................................................3
5. MLX90224 Electrical Specifications ........................................................................................................3
6. MLX90224 Sensor Specific Specifications ...............................................................................................4
7. General Description................................................................................................................................4
8. Performance Graphs ..............................................................................................................................5
9. Applications Information ........................................................................................................................6
10. Standard information regarding manufacturability of Melexis products with different soldering
processes...............................................................................................................................................7
11. ESD Precautions ...................................................................................................................................7
12. Package Information ............................................................................................................................8
13. Contact .................................................................................................................................................9
14. Disclaimer.............................................................................................................................................9
REVISION 009 – JAN 18
3901090224
Page 2 of 9
MLX90224
Dual Hall Effect Latch
3. Glossary of Terms
Gauss, Tesla: Two units to quantify a magnetic flux density. Conversion: 1 mT = 10 Gauss
Bop: B Operating Point: When the magnetic flux density increases and reaches the Bop value, the output switches on. This value
is in Gauss.
Brp: B Release Point: When the magnetic flux density decreases and reaches the Brp value, the output switches off. This value is
in Gauss.
4. Absolute Maximum Ratings
Parameter
Supply Voltage
Symbol
VDD
Supply Current
IDD
50 mA
mA
Output Current
IOUT
40 mA
mA
ISCHORT
150 mA
mA
Operating Temperature Range
TA
-40 to 150
°C
Maximum Junction Temp
TJ
175
°C
Magnetic Flux Density
B
Unlimited
mT
Output Short-Circuit Current
Value
24 V
Units
V
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximum-rated conditions for
extended periods may affect device reliability.
5. MLX90224 Electrical Specifications
o
o
DC Operating Parameters TA = -40 C to 85 C, VDD = 4.5V to 24V (unless otherwise specified)
Parameter
Supply Voltage
Symbol Test Conditions
VDD
Operating
Supply Voltage Ramp up
Min.
Typ.
4.5
Max.
Units
24
V
1.5
Supply Current
IDD
Output Current
IOUT
B>BOP
Saturation Output Voltage
VSAT
B>BOP, IOUT=20 mA
Output Voltage
VOUT
B