0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MLX90809LXG-EAD-003-RE

MLX90809LXG-EAD-003-RE

  • 厂商:

    MELEXIS(迈来芯)

  • 封装:

    SOIC16_300MIL_EP

  • 描述:

    IC PRESSURE SENSOR

  • 数据手册
  • 价格&库存
MLX90809LXG-EAD-003-RE 数据手册
MLX90809 Relative Pressure Sensor 1. Features and Benefits 2. Application Examples ▪ High accuracy relative pressure sensor (+/-1.5%FSO) ▪ Ratiometric analog output or digital SENT output ▪ Fully integrated IC: MEMS, analog front end circuitry, 16 bit microcontroller, analog back end circuitry, voltage regulators ▪ ▪ ▪ ▪ Large automotive temperature range (-40°C to 150°C) Automotive qualified and automotive diagnostic features (clamping levels, broken track diagnostics, multiple internal fault diagnostics) ▪ Factory calibrated and/or fully programmable through the connector for customized calibration curves ▪ Back side exposed relative pressure sensor for higher resistance to common automotive media ▪ Assembled in a robust easy to seal package ▪ Automotive applications ▪ Vacuum measurement ▪ Clogged filter detection ▪ Seat lumbar cushion sensor Industrial applications ▪ Vacuum sensor ▪ Process monitoring ▪ Fluid pressure (low pressure/high accuracy) Consumer/Home appliance applications ▪ Filter monitoring ▪ Dispensing/metering systems ▪ White goods 3. Ordering information Part No. Temperature Code Package Code Option Code Packing Form Code MLX90809 L (-40°C to 150°C) XG EAD-000 RE MLX90809 L (-40°C to 150°C) XG EAD-003 RE MLX90809 L (-40°C to 150°C) XG EAD-007 RE MLX90809 L (-40°C to 150°C) XG EAD-100 RE Option code legend: EAD-000 = 0.05 to -1.05 bar relative pressure / 0.5 to 4.5 V analog output EAD-003 = 0 to 1 bar relative pressure / 0.5 to 4.5 V analog output EAD-007 = 0 to -1 bar relative pressure / 0.5 to 4.5 V analog output EAD-100 = 0.05 to -1.2 bar relative pressure / 193 to 3896 LSB SENT output REVISION 005 – MARCH 2020 390109080901 MLX90809 Relative Pressure Sensor 4. Functional Diagram Broken wire detection Test Temperature sensor Piezoresistive sensing element OPA Micro controller M U X ADC 16 bits Analog driver Gain & Offset temperature compensation Pressure Linearization DAC Gain 12 bits Analog Output Programmable filter Diagnostics Logic Diagnostic signals Vext Analog & Digital Regulator and POR DSP Gain & Offset compensation Overvoltage & reverse voltage protection Rom FW EE PROM SENT driver Ram Slew rate control SENT Output Ground 5. General Description The MLX90809 is a packaged, factory calibrated, integrated relative pressure sensor delivering a ratiometric analog or digital (using the SENT protocol) signal. Use of an optimized architecture and a high density CMOS technology imparts the MLX90809 with best in class automotive EMC performance. A DSP based architecture using a 16bit microcontroller provides outstanding performance. A smart package and die assembly concept suits applications with stringent automotive temperature and stress conditions needing small drift over life. 6. Glossary of Terms Bar: Pressure unit (1bar = 100kPa) ADC: Analog to Digital Converter DAC: Digital to Analog Converter DSP: Digital Signal Processor EMC: Electro Magnetic Compatibility SENT: Single Edge Nibble Transmission FSO: Full Span Output REVISION 005 – MARCH 2020 390109080901 Page 2 of 15 MLX90809 Relative Pressure Sensor Contents 1. Features and Benefits ....................................................................................................................... 1 2. Application Examples ........................................................................................................................ 1 3. Ordering information ........................................................................................................................ 1 4. Functional Diagram ........................................................................................................................... 2 5. General Description .......................................................................................................................... 2 6. Glossary of Terms ............................................................................................................................. 2 7. Absolute Maximum Ratings .............................................................................................................. 4 8. Pin Definitions and Descriptions........................................................................................................ 4 9. General Electrical Specifications........................................................................................................ 6 10. Detailed General Description .......................................................................................................... 8 11. Programmed Settings ..................................................................................................................... 8 11.1. MLX90809LXG-EAD-000 .............................................................................................................. 9 11.2. MLX90809LXG-EAD-003 .............................................................................................................. 9 11.3. MLX90809LXG-EAD-007 ............................................................................................................ 10 11.4. MLX90809LXG-EAD-100 ............................................................................................................ 10 12. Application Information ................................................................................................................ 12 13. Standard information regarding manufacturability of Melexis products with different soldering processes ....................................................................................................................................... 13 14. ESD Precautions ............................................................................................................................ 13 15. Package Information ..................................................................................................................... 14 16. Contact ......................................................................................................................................... 15 17. Disclaimer ..................................................................................................................................... 15 REVISION 005 – MARCH 2020 390109080901 Page 3 of 15 MLX90809 Relative Pressure Sensor 7. Absolute Maximum Ratings Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. Parameter Remarks Value Units Supply Voltage (overvoltage) Remark 1 18 V Reverse Voltage Protection Remark 2 -14 V Positive output voltage Remark 1 18 V Reverse output voltage Remark 1 -0.5 V Operating Temperature Range -40 to 150 C Storage Temperature Range -40 to 150 C Burst pressure (Room Temperature) (AEC Q100 002) 5 Bar Table 1: Absolute maximum ratings Remark 1: No time limit or temperature limit for these over voltage conditions. Remark 2: Reverse Voltage Protection at -14V at 150C for maximum 1 hour. At Room Temperature that condition can apply for maximum 24 hours. 8. Pin Definitions and Descriptions ZZZZZZZZZZ ZZZZZZZZZZ Symbol VVVVV-vvv YYWW YYWW Function / Description Device used- design revision YY Year of assembly WW Calendar week of assembly ZZZZZZZZZZ Wafer lot number MLXVVVVV-vvv MLXVVVVV-vvv Figure 1: Package marking and pin out (Top view: left; Bottom view: right) REVISION 005 – MARCH 2020 390109080901 Page 4 of 15 MLX90809 Relative Pressure Sensor Pin number 1 2 3 4 5 6 7 8 Description SENT output SENT output Supply Input Test pin Not connected Ground Analog output Analog output Pin number 16 15 14 13 12 11 10 9 Description SENT output SENT output Supply Input Test pin Not connected Ground Analog output Analog output Table 2: Pin out definitions and descriptions Only one of the application pins needs to be connected: one of the Supply Input pins (3 or 14), one of the Ground pins (6 or 11) and one of the selected (either analog (7,8,9,10) or SENT(1,2,15,16)) output pins. See section 9 for the detailed information on the application pins connections. Symbol Function / Description VVVVV-vvv Device used- design revision YY Year of assembly WW Calendar week of assembly ZZZZZZZZZZ Wafer lot number Table 3: Package label definition REVISION 005 – MARCH 2020 390109080901 Page 5 of 15 MLX90809 Relative Pressure Sensor 9. General Electrical Specifications DC Operating Parameters TA = -40°C to 150°C, VDD = 5V (unless otherwise specified). Parameter Nominal supply voltage Nominal supply current Analog Output Load (Resistive) Analog Output Load (Capacitive) SENT Output Load (Capacitive) SENT Output Load (C-R-C) Symbol Vdd Idd Rload Remarks Diagnostic limits Diag low Pull-up ≥ 4.7kΩ Min 4.5 No output load connected Pull up or Pull down Cload Typ Max 5 5.5 7 8 4.7 2.2 470 nF Cload 2.2 nF CRCload 1.1nF + 220Ohm + 1.1nF 3 3 Pull-down ≥ 4.7kΩ Diag high Pull-up ≥ 4.7kΩ Pull-down ≥ 8kΩ Clamping levels Analog saturation output level Clamp low Clamp high Programmable range with 8 bit resolution for the low clamping level, 9 for the high (for the default programmed levels see section 8), +/-10mV accuracy on the programmed clamping level Vsat high Pull-up ≥ 4.7kΩ Pull-down ≥ 4.7kΩ Pull-down ≥ 10kΩ Vsat low Pull-up ≥ 4.7kΩ Pull-down ≥ 4.7kΩ Power up time Response time Analog Output Response time SENT Output Programmable pressure spans (Positive pressure on package top side, see remark 3, 5) Programmable pressure spans (vacuum on package top side, see remark 3,5) Overall accuracy REVISION 005 – MARCH 2020 390109080901 Units V mA kOhm %Vdd 96 96 0 %Vdd 25 %Vdd 50 100 %Vdd 97 96 97 0 0 100 100 100 3 3 5.5 %Vdd 1 msec 4 frames Time from reaching minimum allowed supply voltage of 4.5V till having the output within specification Time needed for the output to react to a pressure change from 10% to 90% of its final value (pressure change corresponding to maximum a 4V output change). Using default filter settings SSF = 1, PFLT = 0. 3 %Vdd msec The pressure spans defined correspond to an analog output span of 4V or to the 12 bit pressure information on the SENT output 0.5 1 bar Relative The pressure spans defined correspond to an analog output span of 4V or to the 12 bit pressure information on the SENT output Remark 4 -0.5 bar Relative 1.5 %FSO Taking into account the drifts over temperature and over life Page 6 of 15 MLX90809 Relative Pressure Sensor Ratiometricity error Output noise analog output Output noise SENT output Internal Temperature Error on SENT Output BW limited to 50kHz. Using default filter settings SSF = 1, PFLT = 0. BW limited to 50kHz. Using default filter settings SSF = 1, PFLT = 0. Tptat 0 hours Over life -5 -10 0.2 2 %Vdd mVrms 1.8 LSBrms 5 10 °C Table 4: Electrical specifications Remark 3: The top side of the package is defined as the side with the small hole and readable marking. Remark 4: There are no limitations on the vacuum level that the MLX90809 can measure. Remark 5: The pressure span is defined as being equal to UPL-LPL (upper pressure limit minus lower pressure limit like described for the default calibrated curve in paragraph 8). The atmospheric pressure should always belong to the programmed transfer function. REVISION 005 – MARCH 2020 390109080901 Page 7 of 15 MLX90809 Relative Pressure Sensor 10. Detailed General Description The pressure sensing element consists of a square diaphragm realized in the silicon chip by backside etching. The diaphragm reacts to a pressure difference between the top and bottom side of the diaphragm. The internal strain increases, in particular at the border of the diaphragm. Here, the piezo-resistive elements have been implanted into the silicon diaphragm, which act as a transducer. The electronics front end amplifies the signal from the bridge, performs a coarse offset compensation and an ADC conversion. The DSP performs the compensations over temperature. Furthermore, the digital circuit provides some filtering, the possibility to linearize the pressure signal and also implements the clamping function. The analog back end consists of a 12 bit DAC and an output driver. This chip delivers an analog output proportional to the pressure or a SENT output compliant with SAE J2716 spec dated January 2010. A broken wire detection block allows actively driving the output to one of the rails in case of a broken supply or ground connection. Extensive protection of the supply lines allows the MLX90809 to handle extreme overvoltage conditions and is immune to severe external disturbances. Several diagnostic functions (over-voltage, undervoltage, overpressure, under pressure detections) have been implemented on the 90809 and can be enabled by programming EEPROM settings. Figure 2 describes MLX90809 block diagram. Broken wire detection Test Temperature sensor Piezoresistive sensing element OPA Micro controller M U X ADC 16 bits Analog driver Gain & Offset temperature compensation Pressure Linearization DAC Gain 12 bits Analog Output Programmable filter Diagnostics Logic Rom FW Diagnostic signals Vext Analog & Digital Regulator and POR DSP Gain & Offset compensation Overvoltage & reverse voltage protection EE PROM SENT driver Ram Slew rate control SENT Output Ground Figure 2: MLX90809 block diagram 11. Programmed Settings The MLX90809 is calibrated at the final manufacturing test step. During the calibration, settings are stored in the on chip (16x32bit) EEPROM to define the pressure transfer curve as well as the output clamping levels. Together with the transfer functions, the IC filter values are set. The default programmed filter settings lead to the noise level and response times described in paragraph 6. The transfer functions calibrated in the different MLX90809LXG-EAD-xxx products with its corresponding performance level maintained over the full temperature range and over life is described for each specific option code below. The MLX90809 can be programmed for pressure spans like those described in paragraph 6 with the atmospheric pressure always inside of the application range. REVISION 005 – MARCH 2020 390109080901 Page 8 of 15 MLX90809 Relative Pressure Sensor Contact Melexis for information on the expected accuracy for other ranges or transfer functions than the default programmed ones. Melexis can support customers delivering parts calibrated with other settings or can support customers by delivering the necessary programming hardware, software and documentation to be able to program the transfer function on the customers manufacturing line. To learn how to use the Melexis hardware and software to program the MLX90809 read the application note “MLX90809 PTC04 Software Description”. 11.1. MLX90809LXG-EAD-000 DC Operating Parameters TA = -40°C to 150°C, VDD = 5V. Parameter Symbol Remarks Transfer curve: Figure 3 Pressure 1 P1 Pressure 2 P2 Output 1 O1 Output 2 O2 Parameter Symbol Remarks Low clamping LCL level High clamping HCL level Overall accuracy expressed as output value Output accuracy εo Overall accuracy expressed as pressure value Pressure accuracy εp Min 0.49 Value 0.05 -1.05 0.5 4.5 Typ Max 0.5 0.51 Unit Bar Bar V V Unit V 4.49 4.5 4.51 V 60 16.5 mV mBar -60 -16.5 11.2. MLX90809LXG-EAD-003 DC Operating Parameters TA = -40°C to 150°C, VDD = 5V. Parameter Symbol Remarks Transfer curve: Figure 4 Pressure 1 P1 Pressure 2 P2 Output 1 O1 Output 2 O2 Parameter Symbol Remarks Low clamping LCL level High clamping HCL level Overall accuracy expressed as output value Output accuracy εo Overall accuracy expressed as pressure value Pressure accuracy εp REVISION 005 – MARCH 2020 390109080901 Min 0.49 Value 0 1 0.5 4.5 Typ Max 0.5 0.51 Unit Bar Bar V V Unit V 4.49 4.5 4.51 V 60 15 mV mBar -60 -15 Page 9 of 15 MLX90809 Relative Pressure Sensor 11.3. MLX90809LXG-EAD-007 DC Operating Parameters TA = -40°C to 150°C, VDD = 5V. Parameter Symbol Remarks Transfer curve: Figure 3 Pressure 1 P1 Pressure 2 P2 Output 1 O1 Output 2 O2 Parameter Symbol Remarks Low clamping LCL level High clamping HCL level Overall accuracy expressed as output value Output accuracy εo Overall accuracy expressed as pressure value Pressure accuracy εp Min 0.25 Value 0 -1 0.5 4.5 Typ Max 0.3 0.35 Unit Bar Bar V V Unit V 4.75 4.8 4.85 V 60 15 mV mBar -60 -15 11.4. MLX90809LXG-EAD-100 DC Operating Parameters TA = -40°C to 150°C, VDD = 5V. Parameter Symbol Remarks Transfer curve: Figure 3 Pressure 1 P1 Pressure 2 P2 Output 1 O1 Output 2 O2 Low clamping LCL level High clamping HCL level Parameter Symbol Remarks Overall accuracy expressed as output value Output accuracy εo Overall accuracy expressed as pressure value Pressure accuracy εp REVISION 005 – MARCH 2020 390109080901 Min -60 -20 Value 0.05 -1.20 193 3896 1 Unit Bar Bar LSB LSB LSB 4088 LSB Typ Max 60 20 Unit LSB mBar Page 10 of 15 MLX90809 Relative Pressure Sensor Output HCL O2 εo εp LCL Relative Pressure in Bars O1 P2 P1 Figure 3: Transfer function negative pressure curve Output HCL O2 εo εp LCL Relative Pressure in Bars O1 P1 P2 Figure 4: Transfer function positive pressure curve REVISION 005 – MARCH 2020 390109080901 Page 11 of 15 MLX90809 Relative Pressure Sensor 12. Application Information The MLX90809 only needs 2 capacitors in the application, a 47nF decoupling capacitor on the supply line and a 47nF load on the analog output pin. When the SENT output is used a 2.2nF capacitor is recommended. MLX90809 in analog mode Vdd 47nF Gnd 47nF AnaOut Figure 4: MLX90809 application schematic in analog mode When using the analog output, Melexis recommends shorting one of the SENT output pins and the test pin to GND. MLX90809 in SENT mode SENTOut 2.2nF Vdd 47nF Gnd Figure 5: MLX90809 application schematic in SENT mode When using the SENT output Melexis recommends shorting one of the analog output pins and the test pin to GND. These recommendations for external components are however only providing a basic protection. Depending on the module design and the EMC speciation requirements different configurations can be needed. Read the application note “System Integration Guidelines” for manufacturing handling as well as sealing recommendations. REVISION 005 – MARCH 2020 390109080901 Page 12 of 15 MLX90809 Relative Pressure Sensor 13. Standard information regarding manufacturability of Melexis products with different soldering processes Our products are classified and qualified regarding soldering technology, solderability and moisture sensitivity level according to following test methods: Reflow Soldering SMD’s (Surface Mount Devices) ▪ ▪ IPC/JEDEC J-STD-020 Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices (classification reflow profiles according to table 5-2) EIA/JEDEC JESD22-A113 Preconditioning of Nonhermetic Surface Mount Devices Prior to Reliability Testing (reflow profiles according to table 2) Wave Soldering SMD’s (Surface Mount Devices) and THD’s (Through Hole Devices) ▪ ▪ EN60749-20 Resistance of plastic- encapsulated SMD’s to combined effect of moisture and soldering heat EIA/JEDEC JESD22-B106 and EN60749-15 Resistance to soldering temperature for through-hole mounted devices Iron Soldering THD’s (Through Hole Devices) ▪ EN60749-15 Resistance to soldering temperature for through-hole mounted devices Solderability SMD’s (Surface Mount Devices) and THD’s (Through Hole Devices) ▪ EIA/JEDEC JESD22-B102 and EN60749-21 Solderability For all soldering technologies deviating from above mentioned standard conditions (regarding peak temperature, temperature gradient, temperature profile etc) additional classification and qualification tests have to be agreed upon with Melexis. The application of Wave Soldering for SMD’s is allowed only after consulting Melexis regarding assurance of adhesive strength between device and board. Melexis is contributing to global environmental conservation by promoting lead free solutions. For more information on qualifications of RoHS compliant products (RoHS = European directive on the Restriction Of the use of certain Hazardous Substances) please visit the quality page on our website: http://www.melexis.com/quality.aspx 14. ESD Precautions Electronic semiconductor products are sensitive to Electro Static Discharge (ESD). Always observe Electro Static Discharge control procedures whenever handling semiconductor products. REVISION 005 – MARCH 2020 390109080901 Page 13 of 15 MLX90809 Relative Pressure Sensor 15. Package Information Figure 6: MLX90809 package drawing Table in mm A A1 A2 D D1 D2 E E1 E2 min 2.28 -0.025 10.19 7.7 3.7 7.45 4.8 1.9 max 2.45 0.075 2.34 REF 10.33 8.1 4.1 7.59 5.2 2.3 B 0.326 0.486 L 0.74 0.99 G1 1.5 1.7 G2 0.56 0.96 A: total package thickness (body thickness + stand off) A1: package stand off Table in mm min max α 0o 8o c 0.2 0.33 H 10.11 10.51 e 1.27 BSC Table 5: Detailed package dimensions REVISION 005 – MARCH 2020 390109080901 Page 14 of 15 MLX90809 Relative Pressure Sensor 16. Contact For the latest version of this document, go to our website at www.melexis.com. For additional information, please contact our Direct Sales team and get help for your specific needs: Europe, Africa Telephone: +32 13 67 04 95 Email : sales_europe@melexis.com Americas Telephone: +1 603 223 2362 Email : sales_usa@melexis.com Asia Email : sales_asia@melexis.com 17. Disclaimer The information furnished by Melexis herein (“Information”) is believed to be correct and accurate. Melexis disclaims (i) any and all liability in connection with or arising out of the furnishing, performance or use of the technical data or use of the product(s) as described herein (“Product”) (ii) any and all liability, including without limitation, special, consequential or incidental damages, and (iii) any and all warranties, express, statutory, implied, or by description, including warranties of fitness for particular purpose, noninfringement and merchantability. No obligation or liability shall arise or flow out of Melexis’ rendering of technical or other services. The Information is provided "as is” and Melexis reserves the right to change the Information at any time and without notice. Therefore, before placing orders and/or prior to designing the Product into a system, users or any third party should obtain the latest version of the relevant information to verify that the information being relied upon is current. Users or any third party must further determine the suitability of the Product for its application, including the level of re liability required and determine whether it is fit for a particular purpose. The Information is proprietary and/or confidential information of Melexis and the use thereof or anything described by the Information does not grant, explicitly or implicitly, to any party any patent rights, licenses, or any other intellectual property rights. This document as well as the Product(s) may be subject to export control regulations. Please be aware that export might require a prior authorization from competent authorities. The Product(s) are intended for use in normal commercial applications. Unless otherwise agreed upon in writing, the Product(s) are not designed, authorized or warranted to be suitable in applications requiring extended temperature range and/or unusual environmental requirements. High reliability applications, such as medical life-support or lifesustaining equipment are specifically not recommended by Melexis. The Product(s) may not be used for the following applications subject to export control regulations: the development, product ion, processing, operation, maintenance, storage, recognition or proliferation of 1) chemical, biological or nuclear weapons, or for the development, production, maintenance or storage of missiles for such weapons: 2) civil firearms, including spare parts or ammunition for such arms; 3) defense related products, or other material for military use or for law enforcement; 4) any applications that, alone or in combination with other goods, substances or organisms could cause serious harm to persons or goods and that can be used as a means of violence in an armed conflict or any similar violent situation. The Products sold by Melexis are subject to the terms and conditions as specified in the Terms of Sale, which can be found at https://www.melexis.com/en/legal/terms-andconditions. This document supersedes and replaces all prior information regarding the Product(s) and/or previous versions of this document. Melexis NV © - No part of this document may be reproduced without the prior written consent of Melexis. (2016) ISO/TS 16949 and ISO14001 Certified REVISION 005 – MARCH 2020 390109080901 Page 15 of 15
MLX90809LXG-EAD-003-RE 价格&库存

很抱歉,暂时无法提供与“MLX90809LXG-EAD-003-RE”相匹配的价格&库存,您可以联系我们找货

免费人工找货