MLX92211LSE-AEA-000-RE 数据手册
MLX92211-AxA
3-wire hall effect Latch
Features and Benefits
Application Examples
Wide operating voltage range : from 2.7V to 24V
Chopper-stabilized amplifier stage
Built-in negative temperature coefficient
Reverse Supply Voltage Protection
Output Current Limit with Auto-Shutoff
Under-Voltage Lockout Protection
Thermal Protection
High ESD rating / Excellent EMC performance
Automotive, Consumer and Industrial
Solid-state switch
3-phase BLDC motor commutation
Wiper motor
Window lifter
Sunroof/Tailgate opener
Seat motor adjuster
Electrical power steering
Product code
Temperature Code
Package Code
Option code
Packing form code
MLX92211
MLX92211
MLX92211
MLX92211
MLX92211
MLX92211
MLX92211
L
L
L
L
L
L
L
UA
SE
SE
UA
SE
UA
SE
AAA-000
AAA-000
ACA-000
ADA-000
ADA-000
AEA-000
AEA-000
BU
RE
RE
BU
RE
BU
RE
Legend:
Temperature Code:
Package Code:
L (-40°C to 150°C)
SE = TSOT-23L
UA = UA (TO92-3L)
AAA => BOP/BRP= ± 3mT, TC = -1100 ppm/°C
ACA => BOP/BRP= ± 3mT, TC = -2000 ppm/°C
ADA => BOP/BRP= ± 14mT, TC = -2000 ppm/°C
AEA => BOP/BRP= ± 3mT, TC = -1100 ppm/°C, 8kV ESD HBM
BU=Bulk | RE = Reel
MLX92211LUA-AAA-000-BU
Option Code:
Packing Form:
Ordering example:
1. Functional Diagram
2. General Description
VDD
Voltage Regulator
with Reverse Polarity
Protection
Temperature
Compensation
Switched
Hall
Plate
UnderVoltage
Lockout
Bop/Brp
reference
Thermal
Protection
Open-Drain
Output
CDS
Amplifier
Control
Current
Limit &
Auto-Shutoff
OUT
The Melexis MLX92211 is the second generation Halleffect latch designed in mixed signal CMOS technology.
The device integrates a voltage regulator, Hall sensor with
advanced offset cancellation system and an open-drain
output driver, all in a single package. Based on a brand
new platform, the magnetic core is using an improved
offset cancellation system allowing faster and more
accurate processing while being temperature insensitive
and stress independent. In addition is implemented a
negative temperature coefficient to compensate the
natural behaviour of magnets becoming weaker with rise
in temperature.
GND
390109221101
Rev. 010
Page 1 of 16
www.melexis.com
Datasheet
December/19
MLX92211-AxA
3-wire hall effect Latch
The included voltage regulator operates from 2.7 to 24V,
hence covering a wide range of applications. With the
built-in reverse voltage protection, a serial resistor or
diode on the supply line is not required so that even
remote sensors can be specified for low voltage operation
down to 2.7V while being reverse voltage tolerant.
In the event of a drop below the minimum supply voltage
during operation, the under-voltage lock-out protection
will automatically freeze the device, preventing the
electrical perturbation to affect the magnetic
measurement circuitry. The output state is therefore only
updated based on a proper and accurate magnetic
measurement result.
390109221101
Rev. 010
The open drain output is fully protected against shortcircuit with a built-in current limit. An additional
automatic output shut-off is activated in case of a
prolonged short-circuit condition. A self-check is then
periodically performed to switch back to normal
operation if the short-circuit condition is released.
The on-chip thermal protection also switches off the
output if the junction temperature increases above an
abnormally high threshold. It will automatically recover
once the temperature decreases below a safe value.
With latching magnetic characteristics, the output is
turned low or high respectively with a sufficiently strong
South or North pole facing the package top side. When
removing the magnetic field, the device keeps its previous
state.
Page 2 of 16
www.melexis.com
Datasheet
December/19
MLX92211-AxA
3-wire hall effect Latch
Table of Contents
1. Functional Diagram .................................................................................................................................... 1
2. General Description ................................................................................................................................... 1
Table of Contents ............................................................................................................................................. 3
3. Absolute Maximum Ratings ..................................................................................................................... 5
4. General Electrical Specifications ........................................................................................................... 6
5. Magnetic Specifications ............................................................................................................................. 8
5.1. MLX92211LSE-AAA-000/ MLX92211LUA-AAA-000 ........................................................................... 8
5.2. MLX92211LSE-ACA-000 .................................................................................................................................. 8
5.3. MLX92211LSE-ADA-000/ MLX92211LUA-ADA-000 ........................................................................... 8
5.4. MLX92211LSE-AEA-000/ MLX92211LUA-AEA-000 ............................................................................ 8
6. Output Behaviour versus Magnetic Pole ............................................................................................. 9
6.1. South Pole Active ................................................................................................................................................ 9
6.2. North Pole Active ................................................................................................................................................ 9
7. Performance Graphs ................................................................................................................................10
7.1. Magnetic parameters vs. TA ......................................................................................................................... 10
7.2. Magnetic parameters vs. VDD ....................................................................................................................... 10
7.3. VDSon vs. TA .......................................................................................................................................................... 10
7.4. VDSon vs. VDD ........................................................................................................................................................ 10
7.5. IDD vs. TA ............................................................................................................................................................... 10
7.6. IDD vs. VDD ............................................................................................................................................................ 10
7.7. IOFF vs. TA ............................................................................................................................................................. 11
7.8. IOFF vs. VOUT ......................................................................................................................................................... 11
8. Application Information .........................................................................................................................12
8.1. Typical Three-Wire Application Circuit .................................................................................................. 12
8.2. Automotive and Harsh, Noisy Environments Three-Wire Circuit ................................................ 12
9. Standard information regarding manufacturability of Melexis products with different
soldering processes .................................................................................................................................13
10. ESD Precautions ......................................................................................................................................13
11. Packages ....................................................................................................................................................14
11.1. SE Package (TSOT-23) package information ...................................................................................... 14
1.1 UA (TO92 - 3L) .................................................................................................................................................. 15
12. Contact ........................................................................................................................................................16
390109221101
Rev. 010
Page 3 of 16
www.melexis.com
Datasheet
December/19
MLX92211-AxA
3-wire hall effect Latch
13. Disclaimer .................................................................................................................................................16
390109221101
Rev. 010
Page 4 of 16
www.melexis.com
Datasheet
December/19
MLX92211-AxA
3-wire hall effect Latch
3. Absolute Maximum Ratings
Parameter
Supply Voltage
(1, 2)
Supply Voltage (Load dump)
Supply Current
(1, 2, 4)
Supply Current
(1, 3, 4 )
Reverse Supply Voltage
(1, 3)
(1, 2)
Reverse Supply Voltage (Load dump)
(1, 3)
Symbol
Value
Units
VDD
+27
V
VDD
+32
V
IDD
+20
mA
IDD
+50
mA
VDDREV
-24
V
VDDREV
-30
V
Reverse Supply Current
(1, 2, 5)
IDDREV
-20
mA
Reverse Supply Current
(1, 3, 5)
IDDREV
-50
mA
Output Voltage
(1, 2)
VOUT
+27
V
Output Current
(1, 2, 5)
IOUT
+20
mA
Output Current
(1, 3, 6, 9,10)
IOUT
+75
mA
Output Current
(1, 3, 6, 11)
IOUT
+85
mA
VOUTREV
-0.5
V
Reverse Output Voltage
(1)
Reverse Output Current
(1, 2)
IOUTREV
-50
mA
Operating Temperature Range
TA
-40 to +150
C
Storage Temperature Range
TS
-55 to +165
C
(7)
TJ
+165
C
ESD Sensitivity – HBM
(8, 9)
-
2000
V
ESD Sensitivity – HBM
(8, 10)
-
4000
V
ESD Sensitivity – HBM
(8, 11)
-
8000
V
ESD Sensitivity – CDM
(12)
-
1000
V
B
Unlimited
mT
Maximum Junction Temperature
Magnetic Flux Density
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximum-rated conditions for
extended periods may affect device reliability.
1
The maximum junction temperature should not be exceeded
2
For maximum 1 hour
3
For maximum 0.5s
4
Including current through protection device
5
Through protection device
6
For V OUT≤27V.
7
For 1000 hours.
8
9
Human Model according AEC-Q100-002 standard
valid for MLX92211ADA
10
11
12
valid for MLX92211AAA/MLX92211ACA
valid for MLX92211AEA
Charged Device Model according AEC-Q100-011 standard
390109221101
Rev. 010
Page 5 of 16
www.melexis.com
Datasheet
December/19
MLX92211-AxA
3-wire hall effect Latch
4. General Electrical Specifications
DC Operating Parameters TA = -40°C to 150°C, VDD = 2.7V to 24V (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min
Supply Voltage
VDD
Supply Current
IDD
Operating
Typ
(1)
Max
Units
2.7
-
24
V
1.5
3.0
4.5
mA
mA
Reverse Supply Current
IDDREV
VDD = -18V
Output Leakage Current
IOFF
VOUT = 12V, VDD = 12V, B
< Brp
0.1
10
µA
VDSon
B > BOP, VDD = 3.8 to
18V, IOUT = 20mA
0.2
0.5
V
tR
VDD = 12V, VPU = 5V,
RPU = 1kΩ
CLOAD = 50pF to GND
0.1
0.3
1
µs
tF
VDD = 12V, VPU = 5V, RPU
= 1kΩ
CLOAD = 50pF to GND
0.1
0.3
1
µs
Output Saturation Voltage
Output Rise Time
(RPU dependent)
-1
(3)
(2)
(2)
Output Fall Time
(On-chip controlled)
Output Current Limit
(4)
ICL
B > BOP, VDD=3.8 to 18V,
VOUT = 12V
22
40
70
mA
Output Current Limit
(5)
ICL
B > BOP, VDD=3.8 to 18V,
VOUT = 12V
30
50
80
mA
Output ON Time under Current Limit
(6)
conditions
tCLON
B > BOP, VPU = 12V, RPU
= 100Ω
150
240
µs
Output OFF Time under Current Limit
(6)
conditions
tCLOFF
B > BOP, VPU = 12V, RPU
= 100Ω
3.5
ms
Chopping Frequency
fCHOP
340
kHz
tPER
6
µs
tD
Average over 1000
successive switching
events @10kHz, square
wave with B≥30mT,
tRISE=tFALL≤20μs
6
µs
tJITTER
Over 1000 successive
switching events @1kHz,
square wave with
B≥30mT, tRISE=tFALL
≤100μs
±3
µs
fSW
B≥30mT and square
wave magnetic field
50
kHz
Output Refresh Period
Delay time
(2)
(2,7)
Output Jitter (p-p)
(2, 8)
Maximum Switching Frequency
1
(2, 9)
30
Typical values are defined at T A = +25°C and V DD = 12V, unless otherwise specified
2
Guaranteed by design and verified by characterization, not production tested
3
RPU and VPU are respectively the external pull-up resistor and pull-up power supply
4
Valid for MLX92211AAA, MLX92211ACA, MLX92211ADA
5
Valid for MLX92211AEA
6
If the Output is in Current Limitation longer than t CLON the Output is switched off in high-impedance state. The Output returns back in active state
at next reaching of B OP or after tCLOFF time interval
7
The Delay Time is the time from magnetic threshold reached to the start of the output switching
8
Output jitter is the unpredictable deviation of the Delay time
9
Maximum switching frequency corresponds to the maximum frequency of the applied magnetic field which is detected without loss of pulses.
390109221101
Rev. 010
Page 6 of 16
www.melexis.com
Datasheet
December/19
MLX92211-AxA
3-wire hall effect Latch
Power-On Time
(1, 2)
tON
Under-voltage Lockout Threshold
VUVL
Under-voltage Lockout Reaction time
tUVL
Thermal Protection Threshold
Thermal Protection Release
(3)
(3)
VDD = 5V, dVDD/dt >
2V/us
2.2
16
35
μs
2.4
2.7
V
1
µs
TPROT
Junction temperature
185
°C
TREL
Junction temperature
170
°C
300
°C/W
200
°C/W
SE Package Thermal Resistance
RTH
UA Package Thermal Resistance
RTH
Single layer (1S) Jedec
board
Single layer (1S) Jedec
board
1
The power-On Time represents the time from reaching V DD =VPOR to the first refresh of the output (first valid output state)
Power-On Slew Rate is not critical for the proper device start-up
3
TPROT and TREL are the corresponding junction temperature values
2
390109221101
Rev. 010
Page 7 of 16
www.melexis.com
Datasheet
December/19
MLX92211-AxA
3-wire hall effect Latch
5. Magnetic Specifications
5.1. MLX92211LSE-AAA-000/ MLX92211LUA-AAA-000
DC Operating Parameters VDD = 3.8 to 24V, TA = -40°C to 150°C
Test
Condition
Operating Point
BOP (mT)
Release Point
BRP (mT)
TC
o
(ppm/ C)
Min
Typ (1)
Max
Min
Typ (1)
Max
TA = -40°C
1.4
3.2
4.7
-4.7
-3.2
-1.4
TA = 25°C
1.4
3
4.7
-4.7
-3.0
-1.4
TA = 150°C
0.7
2.6
5
-5
-2.6
-0.7
Active Pole
Typ
-1100(2)
South Pole
TC
o
(ppm/ C)
Active Pole
5.2. MLX92211LSE-ACA-000
DC Operating Parameters VDD = 3.8 to 24V, TA = -40°C to 150°C
Test
Condition
Operating Point
BOP (mT)
Release Point
BRP (mT)
Min
Typ (1)
Max
Min
Typ (1)
Max
TA = -40°C
1.2
3.2
5.5
-5.5
-3.2
-1.2
TA = 25°C
1.0
2.8
4.7
-4.7
-2.8
-1.0
TA = 150°C
0.5
2.1
4.2
-4.2
-2.1
-0.5
Typ
-2000(2)
North Pole
5.3. MLX92211LSE-ADA-000/ MLX92211LUA-ADA-000
DC Operating Parameters VDD = 3.8 to 24V, TA = -40°C to 150°C
Test
Condition
Operating Point
BOP (mT)
Release Point
BRP (mT)
TC
o
(ppm/ C)
Min
Typ (1)
Max
Min
Typ (1)
Max
TA = -40°C
9.2
15.1
21.0
-21.0
-15.1
-9.2
TA = 25°C
9.4
13.5
17.1
-17.1
-13.5
-9.4
TA = 150°C
6.7
10.3
14.7
-14.7
-10.3
-6.7
Active Pole
Typ
-2000(2)
South Pole
5.4. MLX92211LSE-AEA-000/ MLX92211LUA-AEA-000
DC Operating Parameters VDD = 3.8 to 24V, TA = -40°C to 150°C
Test
Condition
1
Operating Point
BOP (mT)
Release Point
BRP (mT)
TC
o
(ppm/ C)
Min
Typ (1)
Max
Min
Typ (1)
Max
TA = -40°C
1.4
3.2
4.7
-4.7
-3.2
-1.4
TA = 25°C
1.4
3.0
4.7
-4.7
-3.0
-1.4
TA = 150°C
0.7
2.6
5.0
-5.0
-2.6
-0.7
Active Pole
Typ
-1100(2)
South Pole
Typical values are defined at T A = +25°C and V DD, unless otherwise specified
2
B
BT 2 BT1
*106 , ppm / o C; T1 40o C; T2 150o C
T2 T1
value guaranteed by design and verified by characterization, not production tested
25o C
390109221101
Rev. 010
Page 8 of 16
www.melexis.com
Datasheet
December/19
MLX92211-AxA
3-wire hall effect Latch
6. Output Behaviour versus Magnetic Pole
Output behaviour versus magnetic pole
(1)
6.1. South Pole Active
o
o
DC Operating Parameters TA = -40 C to 150 C, VDD = 2.7V to 24V
Parameter
Test Conditions
OUT
South pole
B > BOP
Low (VDSon)
North pole
B < BRP
High (VPU) (2)
6.2. North Pole Active
o
o
DC Operating Parameters TA = -40 C to 150 C, VDD = 2.7V to 24V
1
2
Parameter
Test Conditions
OUT
South pole
B > BOP
High (VPU) (2)
North pole
B < BRP
Low (VDSon)
Magnetic pole facing the branded/top side of the package
Default Output state during power-up
390109221101
Rev. 010
Page 9 of 16
www.melexis.com
Datasheet
December/19
MLX92211-AxA
3-wire hall effect Latch
7. Performance Graphs
7.2. Magnetic parameters vs. VDD
6
6
3
3
Magnetic Field (mT)
Magnetic Field (mT)
7.1. Magnetic parameters vs. TA
0
-3
0
-3
Bop, Vdd= 2.7V
Brp, Vdd= 24V
Bop, Vdd= 24V
Brp, Vdd= 2.7V
Bop, Ta= 25oC
Brp, Ta= 25oC
-6
-40
-20
0
20
40
60
80
100
120
140
Brp, Ta= 150oC
-6
160
2
T A (oC)
7.3. VDSon vs. TA
Bop, Ta= 150oC
6
10
14
VDD (Volts)
18
22
26
7.4. VDSon vs. VDD
0.5
0.4
0.4
VDSon (Volts)
VDSon (Volts)
0.5
0.3
0.2
0.3
0.2
VDD=2.7V
VDD=12V
0.1
0.1
VDD=24V
Ta = -40oC
Ta = 25oC
Ta = 150oC
0
-40
-20
0
20
40
60
80
100
120
140
0
160
2
Ta (oC)
7.5. IDD vs. TA
6
10
14
VDD (Volts)
18
22
26
7.6. IDD vs. VDD
4.5
3.5
3.5
IDD (mA)
IDD (mA)
4.5
2.5
2.5
VDD=2.7V
VDD=12V
VDD=24V
Ta = -40oC
Ta = 25oC
Ta = 150oC
1.5
1.5
-40
-20
0
20
40
60
Ta (oC)
390109221101
Rev. 010
80
100
120
140
160
2
Page 10 of 16
www.melexis.com
6
10
14
VDD (Volts)
18
22
26
Datasheet
December/19
MLX92211-AxA
3-wire hall effect Latch
7.7. IOFF vs. TA
7.8. IOFF vs. VOUT
10
10
Ta = -40oC
Ta = 25oC
8
8
6
6
Ta = 150oC
IOFF(uA)
IOFF (μA)
VOUT=12V
VOUT=24V
4
4
2
2
0
0
-40
-20
0
390109221101
Rev. 010
20
40
60
o
Ta ( C)
80
100
120
140
160
10
12
14
16
18
20
22
24
26
VOUT (Volts)
Page 11 of 16
www.melexis.com
Datasheet
December/19
MLX92211-AxA
3-wire hall effect Latch
8. Application Information
8.1. Typical Three-Wire Application Circuit
MLX92211
VDD
C1
10nF
VCC
RPU
10k
VOUT
OUT
GND
Notes:
1. For proper operation, a 10nF to 100nF bypass capacitor should
be placed as close as possible to the VDD and ground pin.
2. The pull-up resistor RPU value should be chosen in to limit the
current through the output pin below the maximum allowed
continuous current for the device.
3. A capacitor connected to the output is not obligatory, because
the output slope is generated internally.
8.2. Automotive and Harsh, Noisy Environments Three-Wire Circuit
D1
VCC
R1
100 Ohms
MLX92211
10k
VDD
Z1
RPU
C1
VOUT
OUT
10nF
GND
C2
4.7nF
Notes:
1. For proper operation, a 10nF to 100nF bypass capacitor should be placed as close as possible to the VDD and ground pin.
2. The device could tolerate negative voltage down to -27V, so if negative transients over supply line VPEAK< -32V are expected, usage of the
diode D1 is recommended. Otherwise only R1 is sufficient.
When selecting the resistor R1, three points are important:
- the resistor has to limit IDD/IDDREV to 50mA maximum
- the resistor has to withstand the power dissipated in both over voltage conditions (VR12/R1)
- the resulting device supply voltage VDD has to be higher than VDD min (VDD = VCC – R1.IDD)
3. The device could tolerate positive supply voltage up to +27V (until the maximum power dissipation is not exceeded), so if positive
transients over supply line with VPEAK> 32V are expected, usage a zener diode Z1 is recommended. The R1-Z1 network should be sized to
limit the voltage over the device below the maximum allowed.
390109221101
Rev. 010
Page 12 of 16
www.melexis.com
Datasheet
December/19
MLX92211-AxA
3-wire hall effect Latch
9. Standard information regarding manufacturability of Melexis products
with different soldering processes
Our products are classified and qualified regarding soldering technology, solderability and moisture sensitivity level according
to following test methods:
Reflow Soldering SMD’s (Surface Mount Devices)
IPC/JEDEC J-STD-020
Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices
(classification reflow profiles according to table 5-2)
EIA/JEDEC JESD22-A113
Preconditioning of Nonhermetic Surface Mount Devices Prior to Reliability Testing
(reflow profiles according to table 2)
Wave Soldering SMD’s (Surface Mount Devices) and THD’s (Through Hole Devices)
EN60749-20
Resistance of plastic- encapsulated SMD’s to combined effect of moisture and soldering heat
EIA/JEDEC JESD22-B106 and EN60749-15
Resistance to soldering temperature for through-hole mounted devices
Iron Soldering THD’s (Through Hole Devices)
EN60749-15
Resistance to soldering temperature for through-hole mounted devices
Solderability SMD’s (Surface Mount Devices) and THD’s (Through Hole Devices)
EIA/JEDEC JESD22-B102 and EN60749-21
Solderability
For all soldering technologies deviating from above mentioned standard conditions (regarding peak temperature,
temperature gradient, temperature profile etc) additional classification and qualification tests have to be agreed upon with
Melexis.
The application of Wave Soldering for SMD’s is allowed only after consulting Melexis regarding assurance of adhesive
strength between device and board.
Melexis is contributing to global environmental conservation by promoting lead free solutions. For more information on
qualifications of RoHS compliant products (RoHS = European directive on the Restriction Of the use of certain Hazardous
Substances) please visit the quality page on our website: http://www.melexis.com/quality.aspx
10. ESD Precautions
Electronic semiconductor products are sensitive to Electro Static Discharge (ESD).
Always observe Electro Static Discharge control procedures whenever handling semiconductor products.
390109221101
Rev. 010
Page 13 of 16
www.melexis.com
Datasheet
December/19
MLX92211-AxA
3-wire hall effect Latch
11. Packages
11.1. SE Package (TSOT-23) package information
b
C
L
Notes:
E1
1. All dimensions are in millimeters
E
2. Outermost plastic extreme widthdoes not include mold flash or protrusions. Mold
flash and protrusions shall not exceed 0.15mm per side.
3. Outermost plastic extreme length does not include mold flash or protrusions. Mold
flash and protrusions shall not exceed 0.25mm per side.
4. The lead width dimension does not include dambar protrusion. Allowable dambar
protrusion shall be 0.07mm total in excess of the lead width dimension at maximum
material condition.
e
α
5. Dimension is the length of terminal for soldering to a substrate.
6. Formed lead shall be planar with respect to one another with 0.076mm at seating
plane.
Marking:
Top side :
AAA/AEA: 11YY (11: Part Number 92211, YY: Calendar year)
A2 A
ACA: 11CY (11C: Part Number 92211, Y: Calendar Year)
ADA: 11DY (11D: Part Number 92211, Y: Calendar Year)
e1
Bottom side:
A1
AAA/AEA: LLLL (Last 4 digits from Lot#)
ACA/ADA: WWLL (WW: Assembly week, LL: Last digits from Lot#)
D
Hall plate location
1.45
0.80
0.275
Package line
TOP VIEW
SIDE VIEW
A
A1
A2
D
E
E1
L
b
c
e
e1
min
–
0.025
0.85
2.80
2.60
1.50
0.30
0.30
0.10
1.00
0.10
0.90
3.00
3.00
1.70
0.50
0.45
0.20
0.95
BSC
1.90
BSC
0°
max
Pin №
Name
Type
Function
1
2
3
VDD
OUT
GND
Supply
Output
Ground
Supply voltage pin
Open drain output pin
Ground pin
3
1
390109221101
Rev. 010
Page 14 of 16
www.melexis.com
8°
2
Datasheet
December/19
MLX92211-AxA
3-wire hall effect Latch
1.1 UA (TO92 - 3L)
θ1
C
L
θ2
S
L1
θ4
e
θ3
b1
F
b2
e1
J
D
e1
A
E
Notes
Hall plate location
2.05
1. All dimensions are in millimeters
2. Package dimension exclusive molding flash
0.43
1.4
3. The end flash shall not exceed 0.127mm on the top side
Marking
Line1:
AAA/AEA: 11BY (11B part number 92211, Y: Calendar year)
ADA: 11DY (11D part number 92211, Y: Calendar year)
Line2:
LLLL (Last 4 digits from lot#)
Marking side
1
2
3
A
D
E
F
J
L
L1
S
b1
b2
c
e
e1
min
2.80
3.90
1.40
0.00
2.51
14.0
0.90
0.63
0.35
0.43
0.35
2.51
1.24
max
3.20
4.30
1.60
0.20
2.72
15.0
1.10
0.84
0.44
0.52
0.44
2.57
1.30
7°
REF
7°
REF
45°
REF
7°
REF
Min
max
Pin №
Name
Type
Function
1
2
3
VDD
GND
OUT
Supply
Ground
Output
Supply voltage pin
Ground pin
Open drain output pin
1
390109221101
Rev. 010
Page 15 of 16
www.melexis.com
2
3
Datasheet
December/19
MLX92211-AxA
3-wire hall effect Latch
12. Contact
For the latest version of this document, go to our website at www.melexis.com.
For additional information, please contact our Direct Sales team and get help for your specific needs:
Europe, Africa
Telephone: +32 13 67 04 95
Email : sales_europe@melexis.com
Americas
Telephone: +1 603 223 2362
Email : sales_usa@melexis.com
Asia
Email : sales_asia@melexis.com
13. Disclaimer
The information furnished by Melexis herein (“Information”) is believed to be correct and accurate. Melexis disclaims (i) any and all liability in connection with or arising out of the
furnishing, performance or use of the technical data or use of the product(s) as described herein (“Product”) (ii) any and all liability, including without limitation, special,
consequential or incidental damages, and (iii) any and all warranties, express, statutory, implied, or by description, including warranties of fitness for particular purpose, noninfringement and merchantability. No obligation or liability shall arise or flow out of Melexis’ rendering of technical or other services.
The Information is provided "as is” and Melexis reserves the right to change the Information at any time and without notice. Therefore, before placing orders and/or prior to
designing the Product into a system, users or any third party should obtain the latest version of the relevant information to verify that the information being relied upon is current.
Users or any third party must further determine the suitability of the Product for its application, including the level of re liability required and determine whether it is fit for a
particular purpose.
The Information is proprietary and/or confidential information of Melexis and the use thereof or anything described by the In formation does not grant, explicitly or implicitly, to any
party any patent rights, licenses, or any other intellectual property rights.
This document as well as the Product(s) may be subject to export control regulations. Please be aware that export might require a prior authorization from competent authorities.
The Product(s) are intended for use in normal commercial applications. Unless otherwise agreed upon in writing, the Product(s) are not designed, authorized or warranted to be
suitable in applications requiring extended temperature range and/or unusual environmental requirements. High reliability applications, such as medical life-support or lifesustaining equipment are specifically not recommended by Melexis.
The Product(s) may not be used for the following applications subject to export control regulations: the development, production, processing, operation, maintenance, storage,
recognition or proliferation of 1) chemical, biological or nuclear weapons, or for the development, production, maintenance or storage of missiles for such weapons: 2) civil
firearms, including spare parts or ammunition for such arms; 3) defense related products, or other material for military use or for law enforcement; 4) any applications that, alone
or in combination with other goods, substances or organisms could cause serious harm to persons or goods and that can be used as a means of violence in an armed conflict or any
similar violent situation.
The Products sold by Melexis are subject to the terms and conditions as specified in the Terms of Sale, which can be found at https://www.melexis.com/en/legal/terms-andconditions.
This document supersedes and replaces all prior information regarding the Product(s) and/or previous versions of this document.
Melexis NV © - No part of this document may be reproduced without the prior written consent of Melexis. (2016)
ISO/TS 16949 and ISO14001 Certified
390109221101
Rev. 010
Page 16 of 16
www.melexis.com
Datasheet
December/19