MLX92215LSE-AAA-000-RE 数据手册
MLX92215
3-Wire Hall Effect Latch
Features and Benefits
Applications
▪
Wide operating voltage range: from 2.7V to
24V
▪
Consumer and Industrial
▪
Solid-state switch
▪
Chopper-stabilized amplifier stage
▪
E-Bike
▪
Built-in negative temperature coefficient
▪
Motorcycles
▪
Reverse Supply Voltage Protection
▪
3-phase BLDC motor commutation
▪
High ESD rating / Excellent EMC performance
Ordering information
Part No.
MLX92215LUA-AAA-000-BU
MLX92215LSE-AAA-000-RE
Temperature Code
L (-40°C to 150°C)
L (-40°C to 150°C)
Package Code
UA (TO92-3L)
SE (TSOT-23)
MLX92215LSE-ACA-000-RE
L (-40°C to 150°C)
SE (TSOT-23)
MLX92215LUA-AEA-000-BU
MLX92215LSE-AEA-000-RE
MLX92215LSE-AFA-000-RE
MLX92215KLD-AAA-000-RE
MLX92215LST-AAA-000-RE
L (-40°C to 150°C)
L (-40°C to 150°C)
L (-40°C to 150°C)
K (-40°C to 125°C)
L (-40°C to 150°C)
UA (TO92-3L)
SE (TSOT-23)
SE (TSOT-23)
LD (UTQFN)
ST (SOT-23)
Option code
Lxx-AAA, LSE-ACA
Lxx-AEA, LSE-AFA, KLD-AAA, LST-AAA
HBM
4kV
8kV
1. Functional Diagram
2. General Description
VDD
Voltage Regulator
with Reverse Polarity
Protection
Temperature
Compensation
Switched
Hall
Plate
Bop/Brp
reference
Open-Drain
Output
CDS
Amplifier
Control
GND
Comment
BOP/BRP= ± 3mT, TC = -1100 ppm/°C
BOP/BRP= ± 3mT, TC = -1100 ppm/°C
BOP/BRP= ± 3mT, TC = -2000 ppm/°C
Inverted output
BOP/BRP= ± 3mT, TC = -1100 ppm/°C
BOP/BRP= ± 3mT, TC = -1100 ppm/°C
North Active MLX92215LSE-AEA-000
BOP/BRP= ± 3mT, TC = -1100 ppm/°C
BOP/BRP= ± 3mT, TC = -1100 ppm/°C
OUT
The Melexis MLX92215 is the second generation Hall-effect
latch designed in mixed signal CMOS technology.
The device integrates a voltage regulator, Hall sensor with
advanced offset cancellation system and an open-drain
output driver, all in a single package. Based on the existing
platform, the magnetic core is using an improved offset
cancellation system allowing faster and more accurate
processing while being temperature insensitive and stress
independent. In addition is implemented a negative
temperature coefficient to compensate the natural
behaviour of magnets becoming weaker with rise in
temperature.
The included voltage regulator operates from 2.7V to 24V, hence covering a wide range of applications. With the builtin reverse voltage protection, a serial resistor or diode on the supply line is not required so that even remote sensors
can be specified for low voltage operation down to 2.7V while being reverse voltage tolerant.
With latching magnetic characteristics, the output is turned low or high respectively with a sufficiently strong South or
North pole facing the package top side. When removing the magnetic field, the device keeps its previous state.
REVISION 008 – JULY 2021
3901092215
Page 1 of 21
MLX92215
3-Wire Hall Effect Latch
Contents
Features and Benefits.................................................................................................................................1
Applications................................................................................................................................................1
Ordering information .................................................................................................................................1
1. Functional Diagram ................................................................................................................................1
2. General Description................................................................................................................................1
3. Absolute Maximum Ratings ....................................................................................................................4
4. General Electrical Specifications .............................................................................................................5
5. Magnetic Specifications ..........................................................................................................................6
MLX92215LSE-AAA-000 / MLX92215LUA-AAA-000 .......................................................................... 6
MLX92215LSE-ACA-000 ...................................................................................................................... 6
MLX92215LUA-AEA-000 / MLX92215LSE-AEA-000 .......................................................................... 6
MLX92215LSE-AFA-000 ...................................................................................................................... 6
MLX92215KLD-AAA-000 ..................................................................................................................... 7
MLX92215LST-AAA-000 ...................................................................................................................... 7
6. Output Behavior versus Magnetic Pole ..................................................................................................8
South Pole Active ................................................................................................................................ 8
North Pole Active ................................................................................................................................ 8
7. Performance Graphs ..............................................................................................................................9
Magnetic parameters vs. TA ............................................................................................................... 9
Magnetic parameters vs. VDD ............................................................................................................. 9
VDSon vs. TA ........................................................................................................................................... 9
VDSon vs. VDD ......................................................................................................................................... 9
IDD vs. TA ............................................................................................................................................... 9
IDD vs. VDD ............................................................................................................................................. 9
IOFF vs. TA ............................................................................................................................................ 10
IOFF vs. VOUT ........................................................................................................................................ 10
SE Power Derating vs. TA .................................................................................................................. 10
UA Voltage Derating vs. TA ............................................................................................................. 10
LD power Derating vs. TA ............................................................................................................... 10
8. Application Information........................................................................................................................11
Typical Three-Wire Application Circuit ............................................................................................ 11
9. Standard information regarding manufacturability of Melexis products with different soldering
processes.............................................................................................................................................12
REVISION 008 – JULY 2021
3901092215
Page 2 of 21
MLX92215
3-Wire Hall Effect Latch
10. ESD Precautions .................................................................................................................................12
11. Packages.............................................................................................................................................13
TSOT-3L (SE Package) ..................................................................................................................... 13
TO92-3L (UA Package) .................................................................................................................... 15
UTQFN (LD Package) ....................................................................................................................... 17
SOT-3L (ST Package) ....................................................................................................................... 19
12. Contact ...............................................................................................................................................21
13. Disclaimer...........................................................................................................................................21
REVISION 008 – JULY 2021
3901092215
Page 3 of 21
MLX92215
3-Wire Hall Effect Latch
3. Absolute Maximum Ratings
Parameter
Symbol
Value
Units
VDD
+27
V
Supply Voltage (Load dump) (1, 3)
VDD
+32
V
Supply Current (1, 2, 4)
IDD
+20
mA
(1, 3, 4 )
IDD
+50
mA
VDDREV
-24
V
Supply Voltage
Supply Current
(1, 2)
Reverse Supply Voltage (1, 2)
(1, 3)
VDDREV
-30
V
(1, 2, 5)
IDDREV
-20
mA
Reverse Supply Current (1, 3, 5)
IDDREV
-50
mA
VOUT
+27
V
IOUT
+20
mA
IOUT
+75
mA
VOUTREV
-0.5
V
IOUTREV
-50
mA
Operating Temperature Range
TA
-40 to +150
C
Storage Temperature Range
TS
-55 to +165
C
Maximum Junction Temperature (7)
TJ
+165
C
-
4000
V
8000
V
-
500
V
-
1000
V
B
Unlimited
mT
Reverse Supply Voltage (Load dump)
Reverse Supply Current
Output Voltage
(1, 2)
Output Current (1, 2, 5)
Output Current (1, 3, 6)
Reverse Output Voltage
(1)
Reverse Output Current (1, 2)
ESD Sensitivity – HBM
(8) (9)
ESD Sensitivity – HBM (8) (10)
ESD Sensitivity – MM (11)
ESD Sensitivity – CDM
(12)
Magnetic Flux Density
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximum-rated
conditions for extended periods may affect device reliability.
1
The maximum junction temperature should not be exceeded
For maximum 1 hour
3
For maximum 0.5 s
4
Including current through protection device
5
Through protection device
6
For V OUT ≤ 27V
7
For 1000 hours
8
Human Model according AEC-Q100-002 standard
9
Valid for version Lxx-AAA and LSE-ACA
10
Valid for version Lxx-AEA, LSE-AFA, KLD-AAA, LST-AAA
11
Machine Model according AEC-Q100-003 standard
12
Charged Device Model according AEC-Q100-011 standard
2
REVISION 008 – JULY 2021
3901092215
Page 4 of 21
MLX92215
3-Wire Hall Effect Latch
4. General Electrical Specifications
DC Operating Parameters TA = -40°C to 150°C, VDD = 2.7V to 24V (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min
Typ (1)
Max
Units
Supply Voltage
VDD
Operating
2.7
-
24
V
Supply Current
IDD
1.5
3.0
4.5
mA
Reverse Supply Current
IDDREV
VDD = -18V
1
mA
Output Leakage Current
IOFF
VOUT = 12V, VDD = 12V, B < Brp
0.1
10
µA
Output Saturation Voltage
VDSon
B > BOP, VDD = 3.8 to 18V, IOUT = 20mA
0.2
0.5
V
0.1
0.3
1
µs
0.1
0.3
1
µs
Output Rise Time (2)
(RPU dependent)
Output Fall Time (2)
(On-chip controlled)
tR
tF
VDD = 12V, VPU(3) = 5V, RPU = 1kΩ
CLOAD = 50pF to GND
VDD = 12V, VPU = 5V, RPU = 1kΩ
CLOAD = 50pF to GND
Chopping Frequency
fCHOP
340
kHz
Output Refresh Period (2)
tPER
6
µs
Delay time (2,4)
tD
6
µs
Output Jitter (p-p) (2, 5)
tJITTER
±3
µs
50
kHz
Maximum Switching Frequency
Average over 1000 successive switching
events @10kHz, square wave with B≥30mT,
tRISE=tFALL≤20μs
Over 1000 successive switching events
@1kHz, square wave with B≥30mT,
tRISE=tFALL ≤100μs
(2,6)
fSW
B≥30mT and square wave magnetic field
30
Power-On Time (7,8)
tON
VDD = 5V, dVDD/dt > 2V/us
16
SE Package Thermal Resistance
RTH
Single layer (1S) Jedec board
300
°C/W
UA Package Thermal Resistance
RTH
Single layer (1S) Jedec board
200
°C/W
LD Package Thermal Resistance
RTH
Single layer (1S) Jedec board
250
°C/W
35
μs
1
Typical values are defined at T A = +25°C and V DD = 12V
Guaranteed by design and verified by characterization, not production tested
3
RPU and VPU are respectively the external pull-up resistor and pull-up power supply
4
The Delay Time is the time from magnetic threshold reached to the start of the output switching
5
Output jitter is the unpredictable deviation of the Delay time
6
Maximum switching frequency corresponds to the maximum frequency of the applied magnetic field which is detected
without loss of pulses
7
The Power-On Time represents the time from reaching V DD = VPOR to the first refresh of the output (first valid output state)
8
Power-On Slew Rate (is not critical for the proper device start-up)
2
REVISION 008 – JULY 2021
3901092215
Page 5 of 21
MLX92215
3-Wire Hall Effect Latch
5. Magnetic Specifications
MLX92215LSE-AAA-000 / MLX92215LUA-AAA-000
DC Operating Parameters VDD = 3.8 to 24V, TA = -40°C to 150°C
Operating Point
BOP (mT)
Test Condition
Release Point
BRP (mT)
TC
(ppm/oC)
Min
Typ(1)2)
Max
Min
Typ(1)
Max
TJ = -40°C
1
3.2
5
-5
-3.2
-1
TJ = 25°C
1
3
5
-5
-3.0
-1
TJ = 150°C
0.5
2.6
5
-5
-2.6
-0.5
Active Pole
Typ(1)
-1100
South Pole
TC
(ppm/oC)
Active Pole
MLX92215LSE-ACA-000
DC Operating Parameters VDD = 3.8 to 24V, TA = -40°C to 150°C
Operating Point
BOP (mT)
Test Condition
Release Point
BRP (mT)
Min
Typ(1)
Max
Min
Typ(1)
Max
TJ = -40°C
1.2
3.2
5.5
-5.5
-3.2
-1.2
TJ = 25°C
1.0
2.8
4.7
-4.7
-2.8
-1.0
TJ = 150°C
0.5
2.1
4.2
-4.2
-2.1
-0.5
Typ(1)
-2000
North Pole
TC
(ppm/oC)
Active Pole
MLX92215LUA-AEA-000 / MLX92215LSE-AEA-000
DC Operating Parameters VDD = 3.8 to 24V, TA = -40°C to 150°C
Operating Point
BOP (mT)
Test Condition
Release Point
BRP (mT)
Min
Typ(1)3)
Max
Min
Typ(1)
Max
TJ = -40°C
1
3.2
5
-5
-3.2
-1
TJ = 25°C
1
3
5
-5
-3.0
-1
TJ = 150°C
0.5
2.6
5
-5
-2.6
-0.5
Typ(1)
-1100
South Pole
TC
(ppm/oC)
Active Pole
MLX92215LSE-AFA-000
DC Operating Parameters VDD = 3.8 to 24V, TA = -40°C to 150°C
Operating Point
BOP (mT)
Test Condition
1
Release Point
BRP (mT)
Min
Typ(1)4)
Max
Min
Typ(1)
Max
TJ = -40°C
1
3.2
5
-5
-3.2
-1
TJ = 25°C
1
3
5
-5
-3.0
-1
TJ = 150°C
0.5
2.6
5
-5
-2.6
-0.5
Typ(1)
-1100
North Pole
Typical values are defined at T A = +25°C and V DD = 12V
REVISION 008 – JULY 2021
3901092215
Page 6 of 21
MLX92215
3-Wire Hall Effect Latch
MLX92215KLD-AAA-000
DC Operating Parameters VDD = 3.8 to 24V, TA = -40°C to 125°C
Operating Point
BOP (mT)
Test Condition
Min
Typ(1))
TJ = -40°C
1
TJ = 25°C
1
TJ = 125°C
0.5
Release Point
BRP (mT)
TC
(ppm/oC)
Max
Min
Typ(1)
Max
3.2
5
-5
-3.2
-1
3
5
-5
-3.0
-1
2.6
5
-5
-2.6
-0.5
Active Pole
Typ(1)
-1100
South Pole
TC
(ppm/oC)
Active Pole
MLX92215LST-AAA-000
DC Operating Parameters VDD = 3.8 to 24V, TA = -40°C to 150°C
Operating Point
Release Point
Test Condition
BOP (mT)
BRP (mT)
TJ = -40°C
Typ(1)2)
Max
Min
Typ(1)
Max
1
3.2
5
-5
-3.2
-1
TJ = 25°C
1
3
5
-5
-3.0
-1
TJ = 150°C
0.5
2.6
5
-5
-2.6
-0.5
Note: 𝑇𝐶 = 𝐵
𝐵𝑇2 −𝐵𝑇1
25℃
1
Min
×(𝑇2 −𝑇1 )
× 106 , [
𝑝𝑝𝑚
℃
Typ(1)
-1100
South Pole
] ; 𝑇1 = −40℃; 𝑇2 = 150℃
Typical values are defined at T A = +25°C and V DD = 12V
REVISION 008 – JULY 2021
3901092215
Page 7 of 21
MLX92215
3-Wire Hall Effect Latch
6. Output Behavior versus Magnetic Pole
Output behaviour versus magnetic pole (1)
South Pole Active
DC Operating Parameters TA = -40oC to 150oC, VDD = 2.7V to 24V
Parameter
Test Conditions
OUT
South pole
B > BOP
Low (VDSon)
North pole
B < BRP
High (VPU) (2)
North Pole Active
DC Operating Parameters TA = -40oC to 150oC, VDD = 2.7V to 24V
1
2
Parameter
Test Conditions
OUT
South pole
North pole
B > BOP
High (VPU) (2)
B < BRP
Low (VDSon)
Magnetic pole facing the branded/top side of the package
Default Output state during power-up
REVISION 008 – JULY 2021
3901092215
Page 8 of 21
MLX92215
3-Wire Hall Effect Latch
7. Performance Graphs
Magnetic parameters vs. VDD
6
6
3
3
Magnetic Field (mT)
Magnetic Field (mT)
Magnetic parameters vs. TA
0
-3
0
-3
Bop, Vdd= 2.7V
Brp, Vdd= 24V
Bop, Vdd= 24V
Brp, Vdd= 2.7V
-6
-40
-20
0
20
40
60
80
100
120
140
Bop, Ta= 25oC
Bop, Ta= 150oC
Brp, Ta= 25oC
Brp, Ta= 150oC
-6
160
2
T A (oC)
6
VDSon vs. TA
10
14
VDD (Volts)
18
22
26
VDSon vs. VDD
0.5
0.4
0.4
VDSon (Volts)
VDSon (Volts)
0.5
0.3
0.2
0.3
0.2
VDD=2.7V
VDD=12V
0.1
0.1
VDD=24V
Ta = -40oC
Ta = 25oC
Ta = 150oC
0
-40
-20
0
20
40
60
80
100
120
140
0
160
2
Ta (oC)
IDD vs. TA
6
10
14
VDD (Volts)
18
22
26
IDD vs. VDD
4.5
3.5
3.5
IDD (mA)
IDD (mA)
4.5
2.5
2.5
VDD=2.7V
VDD=12V
VDD=24V
Ta = -40oC
Ta = 25oC
Ta = 150oC
1.5
1.5
-40
-20
0
20
40
60
Ta (oC)
REVISION 008 – JULY 2021
3901092215
80
100
120
140
160
2
6
10
14
VDD (Volts)
18
22
26
Page 9 of 21
MLX92215
3-Wire Hall Effect Latch
IOFF vs. TA
IOFF vs. VOUT
10
10
VOUT=12V
VOUT=24V
Ta = -40oC
Ta = 25oC
8
IOFF (µA)
IOFF (μA)
8
6
Ta = 150oC
6
4
4
2
2
0
0
-40
-20
0
20
40
60
Ta ( oC)
80
100
120
140
160
10
12
14
16
18
20
22
24
26
VOUT (Volts)
SE Power Derating vs. TA
UA Voltage Derating vs. TA
0.5
26
TSOT - Rth=300oC/W - PDmax=0.465W
UA(TO-92 3L)
0.4
22
0.3
0.2
14
[V]
VDDmax, [V]
18
10
0.1
6
0.0
-40
-20
0
20
40
60
80
100
120
TA(°C)
140
160
180
2
-40
0
40
o
TA, [ C]
80
120
160
LD power Derating vs. TA
TA (◦C)
REVISION 008 – JULY 2021
3901092215
Page 10 of 21
MLX92215
3-Wire Hall Effect Latch
8. Application Information
Typical Three-Wire Application Circuit
MLX92215
VCC
C1
10nF
VDD
OUT
GND
REVISION 008 – JULY 2021
3901092215
RPU
10k
VOUT
Notes:
1. For proper operation, a 10nF to 100nF bypass capacitor should
be placed as close as possible to the VDD and ground pin.
2. The pull-up resistor RPU value should be chosen in to limit the
current through the output pin below the maximum allowed
continuous current for the device.
3. A capacitor connected to the output is not obligatory, because
the output slope is generated internally.
Page 11 of 21
MLX92215
3-Wire Hall Effect Latch
9. Standard information regarding manufacturability of Melexis products with
different soldering processes
Our products are classified and qualified regarding soldering technology, solderability and moisture sensitivity level according to
following test methods:
Reflow Soldering SMD’s (Surface Mount Devices)
•
•
IPC/JEDEC J-STD-020
Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices
(classification reflow profiles according to table 5-2)
EIA/JEDEC JESD22-A113
Preconditioning of Nonhermetic Surface Mount Devices Prior to Reliability Testing
(reflow profiles according to table 2)
Wave Soldering SMD’s (Surface Mount Devices) and THD’s (Through Hole Devices)
•
•
EN60749-20
Resistance of plastic- encapsulated SMD’s to combined effect of moisture and soldering heat
EIA/JEDEC JESD22-B106 and EN60749-15
Resistance to soldering temperature for through-hole mounted devices
Iron Soldering THD’s (Through Hole Devices)
•
EN60749-15
Resistance to soldering temperature for through-hole mounted devices
Solderability SMD’s (Surface Mount Devices) and THD’s (Through Hole Devices)
•
EIA/JEDEC JESD22-B102 and EN60749-21
Solderability
For all soldering technologies deviating from above mentioned standard conditions (regarding peak temperature, temperature
gradient, temperature profile etc) additional classification and qualification tests have to be agreed upon with Melexis.
The application of Wave Soldering for SMD’s is allowed only after consulting Melexis regarding assurance of adhesive strength
between device and board.
Melexis is contributing to global environmental conservation by promoting lead free solutions. For more information on
qualifications of RoHS compliant products (RoHS = European directive on the Restriction Of the use of certain Hazardous
Substances) please visit the quality page on our website: http://www.melexis.com/quality.aspx
10. ESD Precautions
Electronic semiconductor products are sensitive to Electro Static Discharge (ESD).
Always observe Electro Static Discharge control procedures whenever handling semiconductor products.
REVISION 008 – JULY 2021
3901092215
Page 12 of 21
MLX92215
3-Wire Hall Effect Latch
11. Packages
TSOT-3L (SE Package)
11.1.1. TSOT-3L – Package dimension
3
*1
1
*2
2
*1 = Valid for AAA,AEA,ACA
*2 = Valid for AFA
11.1.2. TSOT-3L – Sensitive spot
1
1.45 ± 0.20 mm
3
2
1.40 ± 0.20 mm
0.80 ± 0.20 mm
3
*1
1
1.14 ± 0.15 mm
*2
2
0.28 ± 0.03 mm
0.60 ± 0.03 mm
*1 = Valid for AAA,AEA,ACA
*2 = Valid for AFA
REVISION 008 – JULY 2021
3901092215
Page 13 of 21
MLX92215
3-Wire Hall Effect Latch
11.1.3. TSOT-3L – Package marking / Pin definition
Top
3
15
X
15XY
Y
Assembly Year
Y: AAA/AEA, assembly year, digit 2
C: ACA, fixed character
F: AFA, fixed character
1
2
1
2
Fixed characters
Bottom
XXXX
XXXX
Last 4 digits of lot number: AAA/AEA/AFA
3rd up to 6 th characters of lot number: ACA
3
Pin #
Name
Type
Function
1
VDD
Supply
Supply Voltage pin
2
OUT
Out
Open drain output pin
3
GND
Ground
Ground pin
REVISION 008 – JULY 2021
3901092215
Page 14 of 21
MLX92215
3-Wire Hall Effect Latch
TO92-3L (UA Package)
1
2
3
11.2.1. TO92-3L – Package dimension
2.05 ± 0.20 mm
2.60 ± 0.13 mm
1.40 ± 0.20 mm
11.2.2. TO92-3L – Sensitive spot
1
2
3
1
2
3
0.44 ± 0.03 mm
1.46 ± 0.13 mm
REVISION 008 – JULY 2021
3901092215
Page 15 of 21
MLX92215
3-Wire Hall Effect Latch
11.2.3. TO92-3L – Package marking / Pin definition
Top
15E
15EY
LLLL
Y
Assembly calendar Year
Fixed characters
LLLL
4th up to 6th character of lot number
1
2
Last digit of year
3
Pin #
Name
Type
Function
1
VDD
Supply
Supply Voltage pin
2
GND
Ground
Ground pin
3
OUT
Out
Open drain output pin
REVISION 008 – JULY 2021
3901092215
Page 16 of 21
MLX92215
3-Wire Hall Effect Latch
UTQFN (LD Package)
11.3.1. UTQFN – Package dimension
11.3.2. UTQFN – Sensitive spot
6
5
4
1.00± 0.10 mm
0.24 ± 0.05 mm
Notes:
1. Terminals and exposed pad are for illustration only.
2. Hall plate center is aligned to package center.
1
2
3
0.75 ± 0.10 mm
REVISION 008 – JULY 2021
3901092215
Page 17 of 21
MLX92215
3-Wire Hall Effect Latch
11.3.3. UTQFN – Package marking / Pin definition
Top
1
2
3
6
7
YWW
.
15
Device name
Dot used to show pin 1 mark
5
Y
WW
Calender week
4
Year (last digit)
Pin #
Name
Type
Function
1
VDD
Supply
Supply Voltage pin
2,6
N.C.
3,4
GND
Ground
Ground pin
5
OUT
Output
Open drain output pin
7
Thermal
Thermal pad
Exposed thermal pad
Not connected
The exposed pad ca n be soldered to the PCB to improve thermal dissipation . C an be connected to the gro und poten tial.
REVISION 008 – JULY 2021
3901092215
Page 18 of 21
MLX92215
3-Wire Hall Effect Latch
SOT-3L (ST Package)
11.4.1. SOT-3L – Package dimension
11.4.2. SOT-3L – Sensitive spot
1
1.45 ± 0.20 mm
REVISION 008 – JULY 2021
3901092215
3
2
1.15 ± 0.10 mm
0.62 ± 0.20 mm
3
1
2
0.31 ± 0.03 mm
1.05 ± 0.10 mm
Page 19 of 21
MLX92215
3-Wire Hall Effect Latch
11.4.3. SOT-3L – Package marking / Pin definition
Top
3
5
YY
5YYLLL
4th to 6th character Lot number
LLL
Assembly Year
Fixed character
1
2
Pin #
Name
Type
Function
1
VDD
Supply
Supply Voltage pin
2
OUT
Output
Open drain output pin
3
GND
Ground
Ground pin
REVISION 008 – JULY 2021
3901092215
Page 20 of 21
MLX92215-AAA
3-Wire Hall Effect Latch
12. Contact
For the latest version of this document, go to our website at www.melexis.com.
For additional information, please contact our Direct Sales team and get help for your specific needs:
Europe, Africa
Telephone: +32 13 67 04 95
Email : sales_europe@melexis.com
Americas
Telephone: +1 603 223 2362
Email : sales_usa@melexis.com
Asia
Email : sales_asia@melexis.com
13. Disclaimer
The content of this document is believed to be correct and accurate. However, the content of this document is furnished "as is" for informational use only and no representation, nor
warranty is provided by Melexis about its accuracy, nor about the results of its implementation. Melexis assumes no responsibility or liability for any errors or inaccuracies that may
appear in this document. Customer will follow the practices contained in this document under its sole responsibility. This do cumentation is in fact provided without warranty, term,
or condition of any kind, either implied or expressed, including but not limited to warranties of merchantability, satisfactory quality, non-infringement, and fitness for purpose.
Melexis, its employees and agents and its affiliates' and their employees and agents will not be responsible for any loss, however arising, from the use of, or reliance on this document.
Notwithstanding the foregoing, contractual obligations expressly undertaken in writing by Melexis prevail over this disclaimer.
This document is subject to change without notice, and should not be construed as a commitment by Melexis. Therefore, before placing orders or prior to designing the product into
a system, users or any third party should obtain the latest version of the relevant information.
Users or any third party must determine the suitability of the product described in this document for its application, including the level of reliability required and determine whether
it is fit for a particular purpose.
This document as well as the product here described may be subject to export control regulations. Be aware that export might require a prior authorization from competent
authorities. The product is not designed, authorized or warranted to be suitable in applications requiring extended temperature range and/or unusual environmental requirements.
High reliability applications, such as medical life-support or life-sustaining equipment or avionics application are specifically excluded by Melexis. The product may not be used for
the following applications subject to export control regulations: the development, production, processing, operation, maintenance, storage, recognition or proliferation of:
1. chemical, biological or nuclear weapons, or for the development, production, maintenance or storage of missiles for such weapons;
2. civil firearms, including spare parts or ammunition for such arms;
3. defense related products, or other material for military use or for law enforcement;
4. any applications that, alone or in combination with other goods, substances or organisms could cause serious harm to persons or goods and th at can be used as a means of
violence in an armed conflict or any similar violent situation.
No license nor any other right or interest is granted to any of Melexis' or third party's intellectual property rights.
If this document is marked “restricted” or with similar words, or if in any case the content of this document is to be reasonably understood as being confidential, the recipient of this
document shall not communicate, nor disclose to any third party, any part of the document without Melexis’ express written consent. The recipient shall take all necessary measures
to apply and preserve the confidential character of the document. In particular, the recipient shall (i) hold document in confidence with at least the same degree of care by which it
maintains the confidentiality of its own proprietary and confidential information, but no less than reasonable care; (ii) restrict the disclosure of the document solely to its employees
for the purpose for which this document was received, on a strictly need to know basis and providing that such persons to whom the document is disclosed are bound by confidentiality
terms substantially similar to those in this disclaimer; (iii) use the document only in connection with the purpose for which this document was received, and reproduce document only
to the extent necessary for such purposes; (iv) not use the document for commercial purposes or to the detriment of Melexis or its customers. The confidentiality obligations set forth
in this disclaimer will have indefinite duration and in any case they will be effective for no less than 10 years from the receipt of this document.
This disclaimer will be governed by and construed in accordance with Belgian law and any disputes relating to this disclaimer will be subject to the exclusive jurisdiction of the courts
of Brussels, Belgium.
The invalidity or ineffectiveness of any of the provisions of this disclaimer does not affect the validity or effectiveness of the other provisions.
The previous versions of this document are repealed.
Melexis © - No part of this document may be reproduced without the prior written consent of Melexis. (2020)
IATF 16949 and ISO 14001 Certified
REVISION 008 – JULY 2021
3901092215
Page 21 of 21