MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
1 Features and Benefits
2 Application Examples
▪
▪
▪
▪
▪
▪
▪
▪
▪
▪
▪
▪
▪
▪
▪
Wide operating voltage range: from 2.7V to 24V
Accurate switching thresholds
Reverse Supply Voltage Protection
Output Current Limit with Auto-Shutoff
Under-Voltage Lockout Protection
Thermal Protection
Traceability with integrated unique ID
High ESD rating / Excellent EMC performance
Automotive, Consumer and Industrial
Solid-state switch
Brake sensor
Clutch sensor
Sunroof/Tailgate opener
Steering Column Lock
Open/Close detection
3 Ordering Information
Product Code
Temperature Code
MLX92231
MLX92231
MLX92231
MLX92231
L
L
L
L
Package Code
SE
UA
SE
UA
Option Code
AAA-0xx
AAA-0xx
AAA-2xx
AAA-2xx
Packing from Code
RE
BU
RE
BU
Legend:
Temperature Code:
Package Code:
Option Code:
L (-40°C to 150°C)
SE = TSOT-3L / UA = TO92-3L
0xx => Perpendicular sensitive
2xx => Lateral sensitive (IMC version)
RE = Reel | BU=Bulk
MLX92231LSE-AAA-003-RE
Packing Form:
Ordering Example:
4 Functional Diagram
VDD
Voltage Regulator
with Reverse Polarity
Protection
Temperature
Compensation
Switched
Hall
Plate
UnderVoltage
Lockout
Bop/Brp
reference
Thermal
Protection
Open-Drain
Output
CDS
Amplifier
Control
OUT
Current
Limit &
Auto-Shutoff
GND
Rev.012 – May 2022
390109223101
Page 1 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
5 General Description
The Melexis MLX92231 is a Hall-effect unipolar switch designed in mixed signal CMOS technology.
The device integrates a voltage regulator, Hall sensor with advanced offset cancellation system, automotive qualified
EEPROM and an open-drain output driver, all in a single package.
Based on the existing robust 922xx platform, the magnetic core has been equipped with a non-volatile memory that is used to
accurately trim the switching thresholds and define the needed output magnetic characteristics (TC, B OP, BRP, Output pole
functionality).
In addition to that an ID has been integrated on the IC to have a complete traceability throughout the process flow.
The included voltage regulator operates from 2.7 to 24V, hence covering a wide range of applications. With the built-in
reverse voltage protection, a serial resistor or diode on the supply line is not required so that even remote sensors can be
specified for low voltage operation down to 2.7V while being reverse voltage tolerant.
In the event of a drop below the minimum supply voltage during operation, the under-voltage lock-out protection will
automatically freeze the device, preventing the electrical perturbation to affect the magnetic measurement circuitry. The
output state is therefore only updated based on a proper and accurate magnetic measurement result.
The chopper-stabilized amplifier uses switched capacitor techniques to suppress the offset generally observed with Hall
sensors and amplifiers. The CMOS technology makes this advanced technique possible and contributes to smaller chip size
and lower current consumption than bipolar technology. The small chip size is also an important factor to minimize the effect
of physical stress. This combination results in more stable magnetic characteristics and enables faster and more precise
design.
The open drain output is fully protected against short-circuit with a built-in current limit. An additional automatic output shutoff is activated in case of a prolonged short-circuit condition. A self-check is then periodically performed to switch back to
normal operation if the short-circuit condition is released. The on-chip thermal protection also switches off the output if the
junction temperature increases above an abnormally high threshold. It will automatically recover once the temperature
decreases below a safe value.
Rev.012 – May 2022
390109223101
Page 2 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
Table of Contents
1
Features and Benefits ....................................................................................................................................... 1
2
Application Examples........................................................................................................................................ 1
3
Ordering Information........................................................................................................................................ 1
4
Functional Diagram........................................................................................................................................... 1
5
General Description .......................................................................................................................................... 2
6
Glossary of Terms ............................................................................................................................................. 5
7
Absolute Maximum Ratings .............................................................................................................................. 5
8
General Electrical Specifications ....................................................................................................................... 6
9
Magnetic Specifications .................................................................................................................................... 7
9.1
MLX92231LSE-AAA-003 ......................................................................................................................................................................... 7
9.2
MLX92231LSE-AAA-004 ......................................................................................................................................................................... 7
9.3
MLX92231LSE-AAA-005 ......................................................................................................................................................................... 7
9.4
MLX92231LSE-AAA-007 ......................................................................................................................................................................... 8
9.5
MLX92231LSE-AAA-009 ......................................................................................................................................................................... 8
9.6
MLX92231LSE-AAA-010 ......................................................................................................................................................................... 8
9.7
MLX92231LSE-AAA-012 ......................................................................................................................................................................... 8
9.8
MLX92231LSE-AAA-013 ......................................................................................................................................................................... 9
9.9
MLX92231LSE-AAA-014 ......................................................................................................................................................................... 9
9.10
MLX92231LSE-AAA-019 ......................................................................................................................................................................... 9
9.11
MLX92231LSE-AAA-021 ......................................................................................................................................................................... 9
9.12
MLX92231LSE-AAA-023 ....................................................................................................................................................................... 10
9.13
MLX92231LSE-AAA-026 ....................................................................................................................................................................... 10
9.14
MLX92231LSE-AAA-029 ....................................................................................................................................................................... 10
9.15
MLX92231LSE-AAA-030 ....................................................................................................................................................................... 10
9.16
MLX92231LSE-AAA-031 ....................................................................................................................................................................... 11
9.17
MLX92231LSE-AAA-032 ....................................................................................................................................................................... 11
9.18
MLX92231LSE-AAA-033 ....................................................................................................................................................................... 11
9.19
MLX92231LUA-AAA-034 ...................................................................................................................................................................... 11
9.20
MLX92231LSE-AAA-038 ....................................................................................................................................................................... 12
9.21
MLX92231LUA-AAA-039 ...................................................................................................................................................................... 12
9.22
MLX92231LSE-AAA-040 ....................................................................................................................................................................... 12
9.23
MLX92231LSE-AAA-041 ....................................................................................................................................................................... 12
9.24
MLX92231LSE-AAA-042 ....................................................................................................................................................................... 13
9.25
MLX92231LSE-AAA-049 ....................................................................................................................................................................... 13
9.26
MLX92231LSE-AAA-051 ....................................................................................................................................................................... 13
9.27
MLX92231LSE-AAA-204 ....................................................................................................................................................................... 13
9.28
MLX92231LSE-AAA-208 ....................................................................................................................................................................... 14
Rev.012 – May 2022
390109223101
Page 3 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
10 Magnetic Behaviour........................................................................................................................................ 16
11 Application Information .................................................................................................................................. 17
11.1
Typical Three-Wire Application Circuit ............................................................................................................................................... 17
11.2
Automotive and Harsh, Noisy Environments Three-Wire Circuit...................................................................................................... 17
12 Standard information regarding manufacturability of Melexis products ......................................................... 18
13 ESD Precautions.............................................................................................................................................. 18
14 Package Information....................................................................................................................................... 19
14.1
TSOT-3L (SE Package)........................................................................................................................................................................... 19
14.2
TO92-3L (UA Package) ......................................................................................................................................................................... 21
15 Contact ........................................................................................................................................................... 23
16 Disclaimer ....................................................................................................................................................... 23
Rev.012 – May 2022
390109223101
Page 4 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
6 Glossary of Terms
Tesla
TC
IMC
POR
Units for the magnetic flux density, 1 mT = 10 Gauss
Temperature Coefficient in ppm/°C
Integrated Magnetic Concentrator
Power on Reset
7 Absolute Maximum Ratings
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute maximum rated conditions for
extended periods may affect device reliability.
Parameter
Supply Voltage
(1, 2)
Supply Voltage (Load Dump)
(1, 4)
Supply Current (1, 2, 3)
Supply Current (1, 3, 4)
Symbol
Value
Units
VDD
+27
V
VDD
+32
V
IDD
+20
mA
IDD
+50
mA
Reverse Supply Voltage
(1, 2)
VDDREV
-24
V
Reverse Supply Voltage
(1, 4)
VDDREV
-30
V
Reverse Supply Current
(1, 2, 5)
IDDREV
-20
mA
Reverse Supply Current
(1, 4, 5)
IDDREV
-50
mA
Output Voltage (1, 2)
VOUT
+27
V
Output Current (1, 2, 5)
IOUT
+20
mA
(1, 4, 6)
IOUT
+75
mA
Reverse Output Voltage
(1)
VOUTREV
-0.5
V
Reverse Output Current
(1, 2)
IOUTREV
-100
mA
Maximum Junction Temperature (7)
TJ
+165
C
Storage Temperature Range
Output Current
Ts
-55 to +165
C
ESD Sensitivity – HBM
(8)
-
4000
V
ESD Sensitivity – CDM
(9)
-
1000
V
B
Unlimited
mT
Magnetic Flux Density
1 The maximum junction temperature should not be exceeded
2 For maximum 1 hour
3 Including current through protection device
4 For maximum 500ms
5 Through protection device
6 For VOUT≤27V
7 For 1000 hours
8 Human Model according AEC-Q100-002 standard
9 Charged Device Model according AEC-Q100-011 standard
Rev.012 – May 2022
390109223101
Page 5 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
8 General Electrical Specifications
DC Operating Parameters VDD = 2.7V to 24V, TA = -40°C to 150°C (unless otherwise specified)
Parameter
Supply Voltage
Supply Current
Reverse supply current
Output Saturation Voltage
Output Leakage
Output Rise Time (2, 6)
(RPU dependent)
Output Fall Time (2, 6)
(On-chip controlled )
Power-On Time (3,4,7)
Power-On Output State
Output Current Limit
Output ON Time under
Current Limit conditions(8)
Output OFF Time under
Current Limit conditions(8)
Chopping Frequency
Refresh Period
Symbol
VDD
IDD
IDDREV
VDSON
IOFF
Output Jitter (p-p) (2)
tJITTER
Maximum Switching
Frequency (2, 5)
Under-voltage Lockout
Threshold
Under-voltage Lockout
Reaction time (2)
Thermal Protection
Threshold
Thermal Protection Release
SE Package Thermal
Resistance
UA package Thermal
Resistance
Test Conditions
Operating
Min
2.7
1.5
-1
-
Typ(1)
3.0
0.3
-
Max
24
4.5
0.5
10
Units
V
mA
mA
V
µA
0.1
0.3
1
µs
0.1
0.3
1
µs
-
70
25
40
High (VPU)
40
µs
mA
tON
ICL
VDD = -16V
VDD = 3.5 to 24V, IOUT = 20mA
VOUT = 12V, VDD = 12V
RPU = 1kΩ, VDD = 12V, VPU = 5V
CLOAD = 50pF to GND
RPU = 1kΩ, VDD = 12V, VPU = 5V
CLOAD = 50pF to GND
VDD = 5V, dVDD/dt > 2V/us
t < tON
VDD=3.5 to 24V, VOUT = 12V
tCLON
VPU = 12V, RPU = 100Ω
150
240
tCLOFF
VPU = 12V, RPU = 100Ω
-
3.5
-
ms
-
340
6
-
kHz
µs
-
±3.2
-
µs
30
65
-
kHz
VUVL
-
-
2.7
V
tUVL
-
1
-
µs
tR
tF
fCHOP
tPER
fSW
Over 1000 successive switching
events @10kHz triangle wave
magnetic field, B > ±(BOPMAX +20mT)
B > ±3(BOPMAX +1mT), triangle wave
magnetic field
70
µs
TPROT
Junction temperature
-
190(9)
-
°C
TREL
Junction temperature
Single layer PCB, JEDEC standard
test boards
Single layer PCB, JEDEC standard
test boards
-
180(9)
-
°C
RTHJA
RTHJA
300
°C/W
200
°C/W
Typical values are defined at TA = +25°C and VDD = 12V
Guaranteed by design and verified by characterization, not production tested
The Power-On Time represents the time from reaching VDD = 2.7V to the first refresh of the output
Power-On Slew Rate is not critical for the proper device start-up.
Maximum switching frequency corresponds to the maximum frequency of the applied magnetic field which is detected without loss of pulses
RPU and VPU are respectively the external pull-up resistor and pull-up power supply
Activated output with 1 mT overdrive
If the Output is in Current Limitation longer than tCLON the Output is switched off in high-impedance state. The Output returns back in active state at next
reaching of BOP or after tCLOFF time interval
9 TPROT and TREL are the corresponding junction temperature values
1
2
3
4
5
6
7
8
Rev.012 – May 2022
390109223101
Page 6 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
9 Magnetic Specifications
9.1 MLX92231LSE-AAA-003
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Output Polarity
Active Pole
Package
Information
Z-axis sensitive
Direct Switch
South Pole
SE (TSOT-3L)
Output Polarity
Active Pole
Package
Information
-1100(2)
Z-axis sensitive
Direct Switch
North Pole
SE (TSOT-3L)
TC
(ppm/oC)
Output Polarity
Active Pole
Package
Information
Z-axis sensitive
Direct Switch
North Pole
SE (TSOT-3L)
TC
(ppm/oC)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
32.4
37.3
42.7
25.6
29.8
34.6
TA = 25°C
29.6
33.0
36.7
23.3
26.4
29.7
TA = 150°C
21.2
24.8
28.6
16.6
19.8
23.3
Typ(1)
-2000
(2)
9.2 MLX92231LSE-AAA-004
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT)
BRP (mT)
TC
(ppm/oC)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
-7.7
-5.9
-4.3
-5.6
-4.0
-2.3
TA = 25°C
-6.8
-5.5
-4.2
-5.0
-3.7
-2.3
TA = 150°C
-6.8
-4.7
-3.1
-5.0
-3.2
-1.5
Typ(1)
9.3 MLX92231LSE-AAA-005
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
-33.0
-27.9
-23.4
-25.1
-20.9
-17.1
TA = 25°C
-29.0
-26.0
-23.2
-22.3
-19.5
-16.8
TA = 150°C
-26.7
-22.4
-18.6
-20.4
-16.8
-13.6
1
Typical values are defined at TA=+25°C and VDD=12V
2
Temperature coefficient is calculated using the following formula:
Typ(1)
-1100(2)
BOPT 2 − BOPT1
* 106 , ppm / o C; T1 = −40o C; T2 = 150o C
BOP25o C (T2 − T1 )
3
Final magnetic parameters will be covered in the PPAP documentation set, the table below is based on theoretical calculations
Rev.012 – May 2022
390109223101
Page 7 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
9.4 MLX92231LSE-AAA-007
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Output Polarity
Active Pole
Package
Information
0(2)
Z-axis sensitive
Direct Switch
South Pole
SE (TSOT-3L)
TC
(ppm/oC)
Output Polarity
Active Pole
Package
Information
0(2)
Z-axis sensitive
Direct Switch
South Pole
SE (TSOT-3L)
TC
(ppm/oC)
Output Polarity
Active Pole
Package
Information
Z-axis sensitive
Direct Switch
South Pole
SE (TSOT-3L)
Output Polarity
Active Pole
Package
Information
Z-axis sensitive
Direct Switch
South Pole
SE (TSOT-3L)
TC
(ppm/oC)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
20.0
26.0
33.0
14.0
20.0
25.0
TA = 25°C
20.0
26.0
33.0
14.0
20.0
25.0
TA = 150°C
20.0
26.0
33.0
14.0
20.0
25.0
Typ(1)
9.5 MLX92231LSE-AAA-009
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
2.0
3.5
5.0
1.4
2.5
3.3
TA = 25°C
2.5
3.5
4.5
1.8
2.5
3.1
TA = 150°C
2.0
3.5
5.0
1.4
2.5
3.3
Typ(1)
9.6 MLX92231LSE-AAA-010
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT)
BRP (mT)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
8.7
10.7
13.4
6.8
9.0
11.5
TA = 25°C
8.3
10.0
11.8
6.8
8.5
10.1
TA = 150°C
6.1
8.6
11.4
4.9
7.3
9.8
Typ(1)
-1100
(2)
9.7 MLX92231LSE-AAA-012
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
TC
(ppm/oC)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
13.5
16.1
18.8
10.4
12.9
15.5
TA = 25°C
13.0
15.0
17.1
10.0
12.0
14.1
TA = 150°C
10.7
12.9
15.4
8.1
10.4
12.7
Typ(1)
-1100(2)
1 Typical values are defined at TA=+25°C and VDD=12V
2 Temperature coefficient is calculated using the following formula:
BOPT 2 − BOPT1
* 106 , ppm / o C; T1 = −40o C; T2 = 150o C
BOP25o C (T2 − T1 )
3 Final magnetic parameters will be covered in the PPAP documentation set, the table below is based on theoretical calculations
Rev.012 – May 2022
390109223101
Page 8 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
9.8 MLX92231LSE-AAA-013
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Output Polarity
Active Pole
Package
Information
0(2)
Z-axis sensitive
Inverted Switch
South Pole
SE (TSOT-3L)
TC
(ppm/oC)
Output Polarity
Active Pole
Package
Information
-1100(2)
Z-axis sensitive
Direct Switch
South Pole
SE (TSOT-3L)
TC
(ppm/oC)
Output Polarity
Active Pole
Package
Information
Z-axis sensitive
Direct Switch
South Pole
SE (TSOT-3L)
Output Polarity
Active Pole
Package
Information
Z-axis sensitive
Inverted Switch
South Pole
SE (TSOT-3L)
TC
(ppm/oC)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
2.0
3.5
5.0
1.4
2.5
3.3
TA = 25°C
2.5
3.5
4.5
1.8
2.5
3.1
TA = 150°C
2.0
3.5
5.0
1.4
2.5
3.3
Typ(1)
9.9 MLX92231LSE-AAA-014
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
3.6
6.0
8.4
1.5
3.6
6.1
TA = 25°C
3.9
5.5
7.1
2.0
3.5
5.3
TA = 150°C
2.0
4.8
7.1
1.3
3.5
6.7
Typ(1)
9.10 MLX92231LSE-AAA-019
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
21.5
26.0
31.0
19.0
24.0
28.5
TA = 25°C
20.0
23.0
26.0
17.5
21.0
24.0
TA = 150°C
13.0
17.0
22.0
12.0
15.0
20.0
Typ(1)
-2000
(2)
9.11 MLX92231LSE-AAA-021
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
TC
(ppm/oC)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
4.3
5.9
7.7
2.1
3.8
5.4
TA = 25°C
3.8
5.5
7.2
2.0
3.5
5.0
TA = 150°C
3.2
4.8
6.8
1.7
3.0
5.2
Typ(1)
-1100(2)
1 Typical values are defined at TA=+25°C and VDD=12V
2 Temperature coefficient is calculated using the following formula:
BOPT 2 − BOPT1
* 106 , ppm / o C; T1 = −40o C; T2 = 150o C
BOP25o C (T2 − T1 )
3 Final magnetic parameters will be covered in the PPAP documentation set, the table below is based on theoretical calculations
Rev.012 – May 2022
390109223101
Page 9 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
9.12 MLX92231LSE-AAA-023
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Output Polarity
Active Pole
Package
Information
-1100(2)
Z-axis sensitive
Direct Switch
South Pole
SE (TSOT-3L)
TC
(ppm/oC)
Output Polarity
Active Pole
Package
Information
-2000(2)
Z-axis sensitive
Inverted Switch
South Pole
SE (TSOT-3L)
TC
(ppm/oC)
Output Polarity
Active Pole
Package
Information
Z-axis sensitive
Inverted Switch
South Pole
SE (TSOT-3L)
Output Polarity
Active Pole
Package
Information
Z-axis sensitive
Direct Switch
South Pole
SE (TSOT-3L)
TC
(ppm/oC)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
39.0
46.1
53.9
36.3
44.1
52.5
TA = 25°C
38.5
43.0
47.5
35.9
41.0
46
TA = 150°C
28.8
37.1
46.5
25.6
35.0
45.1
Typ(1)
9.13 MLX92231LSE-AAA-026
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
21.5
26.0
31.0
19.0
24.0
28.5
TA = 25°C
20.0
23.0
26.0
17.5
21.0
24.0
TA = 150°C
13.0
17.0
22.0
12.0
15.0
20.0
Typ(1)
9.14 MLX92231LSE-AAA-029
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT)
BRP (mT)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
13.5
16.0
18.8
12.5
15.0
17.9
TA = 25°C
13.3
15.0
16.7
12.3
14.0
15.7
TA = 150°C
10.2
13.0
16.0
9.1
12.0
15.0
Typ(1)
-1100
(2)
9.15 MLX92231LSE-AAA-030
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT)
BRP (mT)
TC
(ppm/oC)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
23.3
27.9
33.0
17.2
21.0
25.4
TA = 25°C
23.1
26.0
29.1
16.9
19.6
22.5
TA = 150°C
18.6
22.4
26.7
13.6
16.9
20.6
1
Typical values are defined at TA=+25°C and VDD=12V
2
Temperature coefficient is calculated using the following formula:
Typ(1)
-1100
(2)
BOPT 2 − BOPT1
* 106 , ppm / o C; T1 = −40o C; T2 = 150o C
BOP25o C (T2 − T1 )
3
3 Final magnetic parameters will be covered in the PPAP documentation set, the table below is based on theoretical calculations
Rev.012 – May 2022
390109223101
Page 10 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
9.16 MLX92231LSE-AAA-031
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT)
BRP (mT)
Output Polarity
Active Pole
Package
Information
0(2)
Z-axis sensitive
Direct Switch
North Pole
SE (TSOT-3L)
TC
(ppm/oC)
Output Polarity
Active Pole
Package
Information
-1100(2)
Z-axis sensitive
Direct Switch
South Pole
SE (TSOT-3L)
TC
(ppm/oC)
Output Polarity
Active Pole
Package
Information
-1100(2)
Z-axis sensitive
Direct Switch
South Pole
SE (TSOT-3L)
TC
(ppm/oC)
Output Polarity
Active Pole
Package
Information
Z-axis sensitive
Direct Switch
South Pole
UA (TO92-3)
TC
(ppm/oC)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
-17.5
-13.5
-10.0
-12.0
-8.5
-5.7
TA = 25°C
-17.5
-13.5
-10.0
-12.0
-8.5
-5.7
TA = 150°C
-17.5
-13.5
-10.0
-12.0
-8.5
-5.7
Typ(1)
9.17 MLX92231LSE-AAA-032
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
20.4
24.6
29.4
17.7
22.6
27.9
TA = 25°C
20.2
23.0
25.9
17.6
21.0
24.4
TA = 150°C
15.4
19.8
25
12.6
17.7
23.5
Typ(1)
9.18 MLX92231LSE-AAA-033
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Min
Typ(1)
Max
Min
Typ(1)
Max
Typ(1)
TA = -40°C
TA = 25°C
18
12.5
TA = 150°C
9.19 MLX92231LUA-AAA-034
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
4.3
5.9
7.7
2.1
3.8
5.4
TA = 25°C
3.8
5.5
7.2
2
3.5
5
TA = 150°C
3.2
4.8
6.8
1.7
3
5.2
Typ(1)
-1100(2)
1 Typical values are defined at TA=+25°C and VDD=12V
2 Temperature coefficient is calculated using the following formula:
BOPT 2 − BOPT1
* 106 , ppm / o C; T1 = −40o C; T2 = 150o C
BOP25o C (T2 − T1 )
3 Final magnetic parameters will be covered in the PPAP documentation set, the table below is based on theoretical calculations
Rev.012 – May 2022
390109223101
Page 11 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
9.20 MLX92231LSE-AAA-038
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Output Polarity
Active Pole
Package
Information
-1100(2)
Z-axis sensitive
Direct Switch
South Pole
SE (TSOT-3L)
TC
(ppm/oC)
Output Polarity
Active Pole
Package
Information
0(2)
Z-axis sensitive
Direct Switch
South Pole
UA (TO92-3)
TC
(ppm/oC)
Output Polarity
Active Pole
Package
Information
-1100(2)
Z-axis sensitive
Direct Switch
South Pole
SE (TSOT-3L)
TC
(ppm/oC)
Output Polarity
Active Pole
Package
Information
Z-axis sensitive
Direct Switch
South Pole
SE (TSOT-3L)
TC
(ppm/oC)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
25.0
28.9
33.3
23.8
27.9
32.3
TA = 25°C
24.1
27.0
30.1
23.2
26.0
29.0
TA = 150°C
20.0
23.3
26.9
19.0
22.3
26.2
Typ(1)
9.21 MLX92231LUA-AAA-039
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
10.0
13.5
17.4
5.7
8.5
12.0
TA = 25°C
10.0
13.5
17.4
5.7
8.5
12.0
TA = 150°C
10.0
13.5
17.4
5.7
8.5
12.0
Typ(1)
9.22 MLX92231LSE-AAA-040
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Min
Typ(1)
Max
Min
Typ(1)
Max
Typ(1)
TA = -40°C
TA = 25°C
66.0
50.0
TA = 150°C
9.23 MLX92231LSE-AAA-041
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Min
Typ(1)
Max
Min
Typ(1)
Max
Typ(1)
TA = -40°C
TA = 25°C
10.2
8.4
TA = 150°C
1
Typical values are defined at TA=+25°C and VDD=12V
2
Temperature coefficient is calculated using the following formula:
-1100(2)
BOPT 2 − BOPT1
* 106 , ppm / o C; T1 = −40o C; T2 = 150o C
BOP25o C (T2 − T1 )
3
Final magnetic parameters will be covered in the PPAP documentation set, the table below is based on theoretical calculations
Rev.012 – May 2022
390109223101
Page 12 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
9.24 MLX92231LSE-AAA-042
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Min
Typ(1)
Max
Min
Typ(1)
Output Polarity
Active Pole
Package
Information
-1100(2)
Z-axis sensitive
Direct Switch
South Pole
SE (TSOT-3L)
TC
(ppm/oC)
Output Polarity
Active Pole
Package
Information
-1100(2)
Z-axis sensitive
Direct Switch
South Pole
SE (TSOT-3L)
TC
(ppm/oC)
Output Polarity
Active Pole
Package
Information
-1100(2)
Z-axis sensitive
Direct Switch
South Pole
SE (TSOT-3L)
TC
(ppm/oC)
Output Polarity
Active Pole
Package
Information
X-axis sensitive
Inverted Switch
South Pole
SE (TSOT-3L)
TC
(ppm/oC)
Max
Typ(1)
TA = -40°C
TA = 25°C
51.2
41
TA = 150°C
9.25 MLX92231LSE-AAA-049
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Min
Typ(3)
Max
Min
Typ(1)
Max
TA = -40°C
13.5
16.0
18.8
12.5
15.0
17.9
TA = 25°C
13.3
15.0
16.7
12.3
14.0
15.7
TA = 150°C
10.2
13.0
16.0
9.1
12.0
15.0
Typ(1)
9.26 MLX92231LSE-AAA-051
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
28.1
32.1
36.7
12.1
14.5
17.1
TA = 25°C
27.0
30.0
33.2
11.6
13.5
15.5
TA = 150°C
22.5
25.9
29.6
9.5
11.6
14.0
Typ(1)
9.27 MLX92231LSE-AAA-204
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT)
BRP (mT)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
4.7
7.0
9.4
3.5
6.2
9.0
TA = 25°C
4.4
6.5
8.7
3.2
5.6
8.1
TA = 150°C
3.4
5.5
7.8
2.2
4.6
7.3
Typ(1)
-1100(2)
1 Typical values are defined at TA=+25°C and VDD=12V
2 Temperature coefficient is calculated using the following formula:
BOPT 2 − BOPT1
* 106 , ppm / o C; T1 = −40o C; T2 = 150o C
BOP25o C (T2 − T1 )
3
Final magnetic parameters will be covered in the PPAP documentation set, the table below is based on theoretical calculations
Rev.012 – May 2022
390109223101
Page 13 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
9.28 MLX92231LSE-AAA-208
DC Operating Parameters VDD = 3.5V to 24V, TA = -40°C to 150°C
Test
Operating Point
Release Point
Condition
BOP (mT) (3)
BRP (mT) (3)
TC
(ppm/oC)
Min
Typ(1)
Max
Min
Typ(1)
Max
TA = -40°C
-12.2
-9.7
-7.2
-11.3
-8.7
-6.1
TA = 25°C
-10.8
-8.9
-7.0
-9.9
-7.9
-5.9
TA = 150°C
-9.7
-7.4
-5.2
-8.8
-6.4
-4.1
1
Typical values are defined at TA=+25°C and VDD=12V
2
Temperature coefficient is calculated using the following formula:
Output Polarity
Active Pole
Package
Information
X-axis sensitive
Inverted Switch
North Pole 3
SE (TSOT-3L)
Typ(1)
-1300(2)
BOPT 2 − BOPT1
* 106 , ppm / o C; T1 = −40o C; T2 = 150o C
BOP25o C (T2 − T1 )
3
Final magnetic parameters will be covered in the PPAP documentation set, the table below is based on theoretical calculations
Rev.012 – May 2022
390109223101
Page 14 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
South active pole (IMC version)
North active pole (IMC version)
South active pole
North active pole
South active pole
North active pole
Rev.012 – May 2022
390109223101
Page 15 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
10 Magnetic Behaviour
Direct South Active Pole
Inverted South Active Pole
Direct North Active Pole
Inverted North Active Pole
Rev.012 – May 2022
390109223101
Page 16 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
11 Application Information
11.1 Typical Three-Wire Application Circuit
MLX92231
VDD
C1
10nF
VCC
RPU
10k
VOUT
OUT
GND
Notes:
1. For proper operation, a 10nF to 100nF bypass capacitor should
be placed as close as possible to the VDD and ground pin.
2. The pull-up resistor RPU value should be chosen in to limit the
current through the output pin below the maximum allowed
continuous current for the device.
3. A capacitor connected to the output is not needed, because the
output slope is generated internally.
11.2 Automotive and Harsh, Noisy Environments Three-Wire Circuit
D1
VCC
R1
100 Ohms
MLX92231
10k
VDD
Z1
C1
RPU
VOUT
OUT
10nF
GND
C2
4.7nF
Notes:
1. For proper operation, a 10nF to 100nF bypass capacitor should be placed as close as possible to the VDD and ground pin.
2. The device could tolerate negative voltage down to -24V, so if negative transients over supply line VPEAK< -30V are expected, usage of the
diode D1 is recommended. Otherwise only R1 is sufficient.
When selecting the resistor R1, three points are important:
- the resistor has to limit IDD/IDDREV to 50mA maximum
- the resistor has to withstand the power dissipated in both over voltage conditions (VR12/R1)
- the resulting device supply voltage VDD has to be higher than VDD min (VDD = VCC – R1.IDD)
3. The device could tolerate positive supply voltage up to +27V (until the maximum power dissipation is not exceeded), so if positive
transients over supply line with VPEAK> 32V are expected, usage a zener diode Z1 is recommended. The R1-Z1 network should be sized to
limit the voltage over the device below the maximum allowed.
Rev.012 – May 2022
390109223101
Page 17 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
12 Standard information regarding manufacturability of Melexis products
Our products are classified and qualified regarding soldering technology, solderability and moisture sensitivity
level according to following test methods:
Reflow Soldering SMD’s (Surface Mount Devices)
• IPC/JEDEC J-STD-020
Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices
(classification reflow profiles according to table 5-2)
• EIA/JEDEC JESD22-A113
Preconditioning of Nonhermetic Surface Mount Devices Prior to Reliability Testing
(reflow profiles according to table 2)
Wave Soldering SMD’s (Surface Mount Devices) and THD’s (Through Hole Devices)
• EN60749-20
Resistance of plastic- encapsulated SMD’s to combined effect of moisture and soldering heat
• EIA/JEDEC JESD22-B106 and EN60749-15
Resistance to soldering temperature for through-hole mounted devices
Iron Soldering THD’s (Through Hole Devices)
• EN60749-15
Resistance to soldering temperature for through-hole mounted devices
Solderability SMD’s (Surface Mount Devices) and THD’s (Through Hole Devices)
• EIA/JEDEC JESD22-B102 and EN60749-21
Solderability
For all soldering technologies deviating from above mentioned standard conditions (regarding peak temperature, temperature
gradient, temperature profile etc) additional classification and qualification tests have to be agreed upon with Melexis.
The application of Wave Soldering for SMD’s is allowed only after consulting Melexis regarding assurance of adhesive strength
between device and board.
Melexis is contributing to global environmental conservation by promoting lead free solutions. For more information on
qualifications of RoHS compliant products (RoHS = European directive on the Restriction Of the use of certain Hazardous
Substances) please visit the quality page on our website: http://www.melexis.com/quality.aspx
13 ESD Precautions
Electronic semiconductor products are sensitive to Electro Static Discharge (ESD).
Always observe Electro Static Discharge control procedures whenever handling semiconductor products.
Rev.012 – May 2022
390109223101
Page 18 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
14 Package Information
14.1 TSOT-3L (SE Package)
14.1.1 TSOT-3L – Package dimensions
3
1
2
14.1.2 TSOT-3L – Sensitive spot
1
3
2
1.40 ± 0.20 mm
0.80 ± 0.20 mm
3
1
2
0.28 ± 0.03 mm
1.45 ± 0.20 mm
1.14 ± 0.15 mm
Rev.012 – May 2022
390109223101
Page 19 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
14.1.3 TSOT-3L – Package marking / Pin definition
Top
3
3
WW
x
3xWW
1
2
1
2
1: No IMC version
3: IMC version
Fixed character
Bottom
LLL
Y
YLLL
Assembly week
Last 3 digits of lot number
Last digit of year
3
Pin #
Name
Type
Function
1
VDD
Supply
Supply Voltage pin
2
OUT
Out
Open drain output pin
3
GND
Ground
Ground pin
Rev.012 – May 2022
390109223101
Page 20 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
14.2 TO92-3L (UA Package)
1
2
3
14.2.1 TO92-3L – Package dimensions
2.05 ± 0.20 mm
2.75 ± 0.13 mm
1.25 ± 0.20 mm
14.2.2 TO92-3L – Sensitive spot
1
2
3
1
2
3
0.44 ± 0.03 mm
1.46 ± 0.13 mm
Rev.012 – May 2022
390109223101
Page 21 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
14.2.3 TO92-3L – Package marking / Pin definition
Top
3
3XWW
YLLL
X
WW
Assembly calendar week
1: No IMC version
3: IMC version
Fixed character
Y
LLL
Last 3 digits of lot number
1
2
Last digit of year
3
Pin #
Name
Type
Function
1
VDD
Supply
Supply Voltage pin
2
GND
Ground
Ground pin
3
OUT
Out
Open drain output pin
Rev.012 – May 2022
390109223101
Page 22 of 23
MLX92231-AAA-xxx
3-Wire Hall Effect Switch
Datasheet
15 Contact
For the latest version of this document, go to our website at www.melexis.com.
For additional information, please contact our Direct Sales team and get help for your specific needs:
Europe, Africa
Telephone: +32 13 67 04 95
Email : sales_europe@melexis.com
Americas
Telephone: +1 603 223 2362
Email : sales_usa@melexis.com
Asia
Email : sales_asia@melexis.com
16 Disclaimer
The content of this document is believed to be correct and accurate. However, the content of this document is furnished "as is" for informational use only and no representation, nor
warranty is provided by Melexis about its accuracy, nor about the results of its implementation. Melexis assumes no responsib ility or liability for any errors or inaccuracies that may
appear in this document. Customer will follow the practices contained in this document under its sole responsibility. This docum entation is in fact provided without warranty, term, or
condition of any kind, either implied or expressed, including but not limited to warranties of merchantability, satisfactory quality, non-infringement, and fitness for purpose. Melexis, its
employees and agents and its affiliates' and their employees and agents will not be responsible for any loss, however arising , from the use of, or reliance on this document.
Notwithstanding the foregoing, contractual obligations expressly undertaken in writing by Melexis prevail over this disclaimer.
This document is subject to change without notice, and should not be construed as a commitment by Melexis. Therefore, before placing orders or prior to designing the product into a
system, users or any third party should obtain the latest version of the relevant information.
Users or any third party must determine the suitability of the product described in this document for its application, including the level of reliability required and determine whether it
is fit for a particular purpose.
This document as well as the product here described may be subject to export control regulations. Be aware that export might require a prior authorization from competent
authorities. The product is not designed, authorized or warranted to be suitable in applications requiring extended temperatu re range and/or unusual environmental requirements.
High reliability applications, such as medical life-support or life-sustaining equipment or avionics application are specifically excluded by Melexis. The product may not be used for the
following applications subject to export control regulations: the development, production, processing, operation, maintenance, storage, recognition or proliferation of:
1. chemical, biological or nuclear weapons, or for the development, production, maintenance or storage of missiles for such weapons;
2. civil firearms, including spare parts or ammunition for such arms;
3. defense related products, or other material for military use or for law enforcement;
4. any applications that, alone or in combination with other goods, substances or organisms could cause serious harm to perso ns or goods and that can be used as a means of violence
in an armed conflict or any similar violent situation.
No license nor any other right or interest is granted to any of Melexis' or third party's intellectual property rights.
If this document is marked “restricted” or with similar words, or if in any case the content of this document is to be reasonably understood as being confidential, the recipient of this
document shall not communicate, nor disclose to any third party, any part of the document without Melexis’ express written consent. The recipient shall take all necessary measures to
apply and preserve the confidential character of the document. In particular, the recipient shall (i) hold document in confidence with at least the same degree of care by which it
maintains the confidentiality of its own proprietary and confidential information, but no less than reasonable care; (ii) restrict the disclosure of the document solely to its employees for
the purpose for which this document was received, on a strictly need to know basis and providing that such persons to whom the document is disclosed are b ound by confidentiality
terms substantially similar to those in this disclaimer; (iii) use the document only in connection with the purpose for which this document was received, and reproduce document only
to the extent necessary for such purposes; (iv) not use the document for commercial purposes or to the detriment of Melexis or its customers. The confidentiality obligations set forth in
this disclaimer will have indefinite duration and in any case they will be effective for no less than 10 years from the receipt of this document.
This disclaimer will be governed by and construed in accordance with Belgian law and any disputes relating to this disclaimer will be subject to the exclusive jurisdiction of the courts of
Brussels, Belgium.
The invalidity or ineffectiveness of any of
The previous versions of this document are repealed.
the
provisions
of
this
disclaimer
does
not
affect
the
validity
or
effectiveness
of
the
other
provisions.
Melexis © - No part of this document may be reproduced without the prior written consent of Melexis. (2022)
IATF 16949 and ISO 14001 Certified
Rev.012 – May 2022
390109223101