FAST RECOVERY RECTIFIER
FR801 THRU FR806
FEATURES
• • • • • • • •
VOLTAGE RANGE CURRENT
50 to 1000 Volts 8.0 Ampere
Glass passivated chip junction Low cost construction Fast switching for high efficiency Low reverse leakage High forward surge current capacity High temperature soldering guaranteed 260℃/10 second,0.375″(9.5mm)lead length at 5 lbs (2.3kg) tension
TO-220AC
MECHANICAL DATA
• • • • • •
Case: Transfer molded plastic Epoxy: UL94V-0 rate flame retardant Polarity: Color band denotes cathode end Lead: Plated axial lead, solderable per MIL-STD-202E method 208C Mounting position: Any Weight: 0.064ounce, 1.81 gram
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25℃ ambient temperature unless otherwise specified Single Phase, half wave, 60Hz, resistive or inductive load For capacitive load derate current by 20% SYMBOLS FR801 FR802 Maximum Repetitive Peak Reverse Voltage VRRM 50 100 Maximum RMS Voltage VRMS 35 70 Maximum DC Blocking Voltage VDC 50 100
• • • Maximum Average Forward Rectified Current 0.375″(9.5mm) lead length at Tc=100℃ Peak Forward Surge Current 8.3ms single half sine wave superimposed on rated load (JEDEC method) Maximum Instantaneous Forward Voltage at 8.0A Maximum DC Reverse Current at rated TA = 25℃ DC Blocking Voltage per element TA = 100℃ Maximum Reverse Recovery Time (NOTE 3)Tj=25℃ Typical Junction Capacitance (NOTE 1) Typical Thermal Resistance (NOTE 2) Operating and Storage Temperature Range Storage Temperature Range
FR803 200 140 200 8.0 200 1.3 10 500
FR804 400 280 400
FR805 600 420 600
FR806 800 560 800
UNIT Volts Volts Volts Amps Amps Volts µA
I(AV) IFSM VF IR trr CJ RθJC TJ TSTG 150
250 50 3.0 (-55 to +150) (-55 to +150)
500
nS pF ℃/W
℃ ℃
Notes: 1. Measured at 1.0 MHz and applied reverse voltage of 4.0 Volts. 2. Thermal Resistance from Junction to CASE 3. Reverse Recovery Test Conditions: IF =0.5A, IR =1.0A, IRR =0.25A
E-mail: sales@cnmic.com
Web Site: www.cnmic.com
FAST RECOVERY RECTIFIER
FR801 THRU FR806
VOLTAGE RANGE CURRENT
50 to 1000 Volts 8.0 Ampere
RATING AND CHRACTERISTIC CURVES FR801G THRU FR806
FIG.1-TYPICAL FORWARD CURRENT DERATING CURVE AVERAGE FOR WARD CU RRENT,
12.0
Single Phase Half Wave 60Hz Resistive or Inductive Load 0.375 ″(9.5mm) Lead Length
FIG.2-MAXIMUM NON-REPETITIVE PEAK FORWARD SURGE CURRENT PEAK FORWARD SURGE
300
CURR ENT, (A)
8.3ms Single Half Sine-Wave (JEDEC Method) T= T jmax 200
8.0
( A)
4.0
100
1 Cycle 0 0 25 50 75 100 125 150 175 0 1 2 4 6 8 10 20 40 60 80 100
AMBIENT TEMPERATURE, (° C)
NUMBER OF CYCLES AT 60 Hz
FIG.3-TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS INSTANTANEOUS REVERSE CURRENT,
20
FIG.4-TYPICAL REVERSE CHARACTERISTICS
10 TJ =100 ° C
IN STANTANEOUS FORWARD CURR ENT,
10
1
(A)
(μA)
1.0
TJ =25 ° C
0.1
0.1
TJ =25 ° C Pulse Width=300us 1% Duty Cycle
0.01 0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
0.01 0 20 40 60 80 100 120 140
INSTANTANEOUS FORWARD VOLTAGE,(V)
PERCENT OF RATED PEAK REVERSE VOLTAGE,(%)
FIG.5-TYPICAL JUNCTION CAPACITANCE
1000
JUNC TION C APAC ITANCE,(pF)
F1G.6-TEST CIRCUIT DIAGRAM AND REVERSE RECOVERY TIME CHARACTERISTIC
Trr
50 Ω 10Ω NONINDUCTIVE NONINDUCTIVE (-) 100 (+) 25 Vdc (approx.) (-) T J =25 ° C f=1MHz Vsig=50mVp-p D.U.T. PULSE GENERATIOR (NOTE 2) (+) OSCILLOSCOPE (NOTE 1)
+0.5A
0 -0.25A
1Ω NON INDUCTIVE
-1.0A
1cm
10 0.1 1.0 10 100
REVERSE VOLTAGE,(V)
NOTES : 1.Rise Time=7ns mas. Input Impedance= 1 magohm. 22pF 2.Rise time=10ns max. Source Impedance= 50 ohms