WRA-YD-6W&WRB-YD -6W Series
6W, WIDE INPUT, ISOLATED & REGULATED DUAL&SINGLE OUTPUT DC-DC CONVERTER
SELECTION GUIDE
Input
Output
Efficiency
Order code
Voltage(VDC)
Current(mA)
Voltage
(%.Typ.)
(VDC)
Max.
Min.
11
±5
±600
±60
76
11
±12
±250
±25
81
4.5-9
11
±15
±200
±20
83
5
4.5-9
11
5
1200
120
76
WRB0512YD-6W
5
4.5-9
11
12
500
50
81
WRB0515YD-6W
5
4.5-9
11
15
400
40
81
WRA1205YD-6W
12
9-18
22
±5
±600
±60
76
WRA1212YD-6W
12
9-18
22
±12
±250
±25
81
WRA1215YD-6W
12
9-18
22
±15
±200
±20
83
WRB1203YD-6W
12
9-18
22
3.3
1500
150
74
WRB1205YD-6W
12
9-18
22
5
1200
120
76
WRB1212YD-6W
12
9-18
22
12
500
50
81
WRB1215YD-6W
12
9-18
22
15
400
40
81
WRA2405YD-6W
24
18-36
40
±5
±600
±60
76
WRA2412YD-6W
24
18-36
40
±12
±250
±25
81
WRA2415YD-6W
24
18-36
40
±15
±200
±20
83
WRB2403YD-6W
24
18-36
40
3.3
1500
150
74
WRB2405YD-6W
24
18-36
40
5
1200
120
76
WRB2407YD-6W
24
18-36
40
7
857.1
85.71
78
WRB2412YD-6W
24
18-36
40
12
500
50
81
WRB2415YD-6W
24
18-36
40
15
400
40
81
WRA4805YD-6W
48
36-72
80
±5
±600
±60
85
WRA4812YD-6W
48
36-72
80
±12
±250
±25
83
WRA4815YD-6W
48
36-72
80
±15
±200
±20
85
WRB4803YD-6W
48
36-72
80
3.3
1500
150
74
WRB4805YD-6W
48
36-72
80
5
1200
120
78
WRB4812YD-6W
48
36-72
80
12
500
50
80
WRB4815YD-6W
48
36-72
80
15
400
40
80
Nominal
◆1500VDC Isolation
◆Operating Temperature: -40℃~﹢85℃
◆Five sided metal shielding
◆No external component required
◆Internal SMD construction
◆RoHS Compliance
◆MTBF>1000Khours
MODEL SELECTION
①
②
③
④
⑤
⑥
WRB 24 15 Y D -6W
①Product Series
②Input Voltage
③Output Voltage
④Wide (2:1) Input Range
⑤DIP24 Package Style ⑥Rated Power
APPLICATIONS
The WRA_YD-6W&WRB_YD-6W Series are
specially designed for applications where a
wide range input voltage power supplies are
isolated from the input power supply in a
distributed power supply system on a circuit
board.These products apply to:
1) Where the voltage of the input power
supply is wide range (Voltage range≤2:1)
2) Where isolation is necessary between
input and output(Isolation voltage≤1500VDC)
3) Where the regulation of the Output voltage
and the output ripple noise are demanded.
4.5-9
5
4.5-9
WRA0515YD-6W
◆Short Circuit Protection(automatic recovery)
5
WRA0512YD-6W
◆Wide (2:1) Input Range
Max*
WRA0505YD-6W
FEATURES
Range
5
WRB0505YD-6W
*Input voltage can't exceed this value,or will cause the permanent damage.
COMMON SPECIFICATIONS
Parameter
Conditions
Min.
Max.
Storage humidity
Units
95
%
Operating temperature
-40
85
℃
Storage temperature
-55
125
℃
Temp. rise at full load
PRODUCT ID DESCRIPTION
Typ.
Lead temperature
℃
40
300
1.5mm from case for 10 seconds
No-load power
0.2
℃
W
Cooling
Free Air Convection
Short circuit protection
Continuous,automatic recovery
Case material
Steel,nickel coated, copper
Isolation voltage
Tested for1 minute and 1mA
1500
VDC
Isolation resistance
Test at 500VDC
1000
MΩ
Isolation Capacitance
Input/Output
MTBF
MICRODC RESERVES THE COPYRIGHT
http://www.microdc.cn
Weight
85
1000
pF
K hours
17
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
g
Page 1 of 3
WRA-YD-6W&WRB-YD -6W Series
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Output power
See below products program
0.6
Positive voltage accuracy
Refer to recommended circuit
Negative voltage accuracy
TYPICAL CHARACTERISTICS
Typ.
Max.
Units
6
W
±1
±3
%
Refer to recommended circuit
±3
±5
%
Load regulation
From 10% to 100% load
±0.5
±1*
%
Ripple **
20MHz Bandwidth
20
50
mVp-p
Temperature drift (Vout)
Refer to recommended circuit
±0.02
Line regulation
Input voltage from low to high
±0.2
±0.5
%
Noise**
20MHz Bandwidth
50
100
mVp-p
Switching frequency
100% load, input voltage range
300
Temperature Derating Graph
%/℃
KHz
RECOMMENDED CIRCUIT
* Dual output models unbalanced load: ±5%.
** Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power Converter section,
Output Graph
application notes.
Case material
APPLICATION NOTE
Requirement on output load
In order to ensure the product operate efficiently and reliably,in addition to a
max load(namely full load), a minimum load is specified for this kind of
DC/DC converter.Make sure the specified range of input voltage is not
exceeded,the minimum output load no less than 10% load the actual
load.If
load is less than the specified minimum load, the output ripple may increase
sharply while its efficiency and reliability will reduce greatly.If the actual
output power is very small,please add an appropriate resistor as extra
loading,or contact our company for other lower output power products.
Recommended Circuit
All the WRA_YD-6W&WRB_YD-6W Series have been tested according to
the following recommended testing circuit before leaving factory.This series
should be tested under load(See figure 1).
If you want to further decrease the input/output ripple,you can increase
capacitance properly or choose capacitors with low ESR. However, the
capacitance of the output filter capacitor must be proper. If the capacitance
is too big, a startup problem might arise. For every channel of output,
provided the safe and reliable operation is ensured, the greatest capacitance
of its filter capacitor sees (Table 1).
General:
Cin: 5V&12V 100μF
24V&48V 100μF-47μF
Cout: 10μF/100mA
Output External Capacitor Table(Table 1)
Single Vout
Dual Vout
Cout
(μF)
(VDC)
(μF)
3.3
2200
±5
680
5
1000
±12
330
12
470
±15
220
15
While using unstable power source,please ensure the output voltage and
ripple voltage do not exceed indexes of the converter. Input current of
power supply should afford the startup current of this kind of DC/DC module
(See figure 2).
General:Ip≤1.4*Iin-max
Cout
(VDC)
Input current
330
--
--
No parallel connection or plug and play
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 2 of 3
WRA-YD-6W&WRB-YD -6W Series
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT
RECOMMENDED FOOTPRINT
Top view grid:2.54mm(0.1inch)
diameter:1.00mm(0.039inch)
Note:
Unit:mm[inch]
Pin section tolerances:±0.10mm[±0.004inch]
General tolerances:±0.25mm[±0.010inch]
FOOTPRINT DETAILS
TUBE OUTLINE DIMENSIONS
Pin
Single
Dual
2、3
GND
GND
9
NC
0V
11
NC
-Vo
14
+Vo
+Vo
16
0V
0V
Vin
Vin
22、23
NC:No connection
When the environment temperature is higher than
71 , the product output power should be less
71℃,
then 60% of the rated power.
No parallel connection or plug and play.
Use dual output simultaneously,forbid pening
output pin (0V) to use as single output.
Note:
Unit :mm[inch]
General tolerances:±0.50mm[±0.020inch]
L=530mm[20.866inch] Tube Quantity: 15pcs
Note:
L=220mm[8.661inch] Tube Quantity: 6pcs
1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
2. Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
3. All specifications measured at Ta=25°C, humidity
很抱歉,暂时无法提供与“WRBxxooYD-6W”相匹配的价格&库存,您可以联系我们找货
免费人工找货