0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MT48LC32M8A2

MT48LC32M8A2

  • 厂商:

    MICRON(镁光)

  • 封装:

  • 描述:

    MT48LC32M8A2 - SYNCHRONOUS DRAM 256Mb: x4, x8, x16 SDRAM - Micron Technology

  • 数据手册
  • 价格&库存
MT48LC32M8A2 数据手册
256Mb: x4, x8, x16 SDRAM SYNCHRONOUS DRAM Features • PC66-, PC100-, and PC133-compliant • Fully synchronous; all signals registered on positive edge of system clock • Internal pipelined operation; column address can be changed every clock cycle • Internal banks for hiding row access/precharge • Programmable burst lengths: 1, 2, 4, 8, or full page • Auto Precharge, includes CONCURRENT AUTO PRECHARGE, and Auto Refresh Modes • Self Refresh Mode • 64ms, 8,192-cycle refresh • LVTTL-compatible inputs and outputs • Single +3.3V ±0.3V power supply MT48LC64M4A2 – 16 Meg x 4 x 4 banks MT48LC32M8A2 – 8 Meg x 8 x 4 banks MT48LC16M16A2 – 4 Meg x 16 x 4 banks For the latest data sheet, please refer to the Micron Web site: www.micron.com/dramds Figure 1: Pin Assignment (Top View) 54-Pin TSOP x4 x8 x16 NC x16 x8 x4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 NC NC DQ0 NC NC DQ0 DQ1 NC NC NC DQ2 NC NC DQ1 DQ3 NC NC Options • Configurations 64 Meg x 4 (16 Meg x 4 x 4 banks) 32 Meg x 8 ( 8 Meg x 8 x 4 banks) 16 Meg x 16 ( 4 Meg x 16 x 4 banks) • WRITE Recovery (tWR) t WR = “2 CLK”1 Marking 64M4 32M8 16M16 A2 TG P FB4, 5 FG3 BB4, 5 BG3 -7E -75 :D • Package/Pinout 54-pin TSOP II OCPL2 (400 mil) (standard) 54-pin TSOP II OCPL2 (400 mil) (lead-free) 60-ball FBGA (x4, x8) 54-ball VFBGA (x16) 60-ball FBGA (x4, x8) (lead-free) 54-ball VFBGA (x16) (lead-free) • Timing (Cycle Time) 7.5ns @ CL = 2 (PC133) 7.5ns @ CL = 3 (PC133) • Die Revision • Self Refresh Standard Low power • Operating Temperature Commercial (0oC to +70oC) Industrial (-40oC to +85oC) NOTE: 1. 2. 3. 4. 5. Refer to Micron Technical Note TN-48-05. Off-center parting line. Consult Micron for availability. Not available in x16 configuration. Actual FBGA part marking shown on page 60. Note: - VDD DQ0 VDDQ DQ1 DQ2 VssQ DQ3 DQ4 VDDQ DQ5 DQ6 VssQ DQ7 VDD DQML WE# CAS# RAS# CS# BA0 BA1 A10 A0 A1 A2 A3 VDD Vss DQ15 DQ7 VssQ DQ14 NC DQ13 DQ6 VDDQ DQ12 NC DQ11 DQ5 VssQ DQ10 NC DQ9 DQ4 VDDQ DQ8 NC Vss NC DQMH DQM CLK CKE A12 A11 A9 A8 A7 A6 A5 A4 Vss - NC NC DQ3 NC NC NC DQ2 NC DQM - The # symbol indicates signal is active LOW. A dash (–) indicates x8 and x4 pin function is same as x16 pin function. Table 1: Address Table 64 Meg x 4 32 Meg x 8 16 Meg x 16 Configuration 16 Meg x 4 x 4 banks 8 Meg x 8 x 4 banks 4 Meg x 16 x 4 banks Refresh Count 8K 8K 8K Row Addressing 8K (A0–A12) 8K (A0–A12) 8K (A0–A12) Bank Addressing 4 (BA0, BA1) 4 (BA0, BA1) 4 (BA0, BA1) Column Addressing 2K (A0–A9, A11) 1K (A0–A9) 512 (A0–A8) Table 2: Key Timing Parameters None L3 None IT3 SPEED GRADE -7E -75 -7E -75 CLOCK ACCESS TIME FREQUENCY CL = 2* CL = 3* 143 MHz 133 MHz 133 MHz 100 MHz – – 5.4ns 6ns 5.4ns 5.4ns – – SETUP TIME 1.5ns 1.5ns 1.5ns 1.5ns HOLD TIME 0.8ns 0.8ns 0.8ns 0.8ns *CL = CAS (READ) latency Part Number Example: MT48LC16M16A2TG-75 PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 1 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. PRODUCTS AND SPECIFICATIONS DISCUSSED HEREIN ARE SUBJECT TO CHANGE BY MICRON WITHOUT NOTICE. 256Mb: x4, x8, x16 SDRAM Figure 2: 60-Ball FBGA Assignment (Top View) 64 Meg x 4 SDRAM 8mm x 16mm “FB” 1 2 3 4 5 6 7 8 32 Meg x 8 SDRAM 8mm x 16mm “FB” 1 2 3 4 5 6 7 8 A B C D E F G H J K L M N P R NC NC VDDQ NC NC VDDQ NC NC NC NC A12 A11 A8 A6 A4 Vss VssQ DQ3 NC VssQ DQ2 NC Vss DQM CK CKE A9 A7 A5 Vss VDD VDDQ DQ0 NC VDDQ DQ1 NC VDD WE# RAS# NC BA1 A0 A2 VDD NC NC VssQ NC NC VssQ NC NC CAS# NC CS# BA0 A10 A1 A3 A B C D E F G H J K L M N P R DQ7 NC VDDQ DQ5 NC VDDQ NC NC NC NC A12 A11 A8 A6 A4 Vss VssQ DQ6 NC VssQ DQ4 NC Vss DQM CK CKE A9 A7 A5 Vss VDD VDDQ DQ1 NC VDDQ DQ3 NC VDD WE# RAS# NC BA1 A0 A2 VDD DQ0 NC VssQ DQ2 NC VssQ NC NC CAS# NC CS# BA0 A10 A1 A3 Depopulated Balls Depopulated Balls NOTE: FBGA pin Symbol, Type, and Descriptions are identical to the listing of the 54-pin TSOP table on page 9. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 2 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 3: 54-Ball FBGA Assignment (Top View) 16 Meg x 16 SDRAM 8mm x 14mm “FG” 1 2 3 4 5 6 7 8 9 A B C D E F G H J Vss DQ14 DQ12 DQ10 DQ8 UDQM A12 A8 Vss DQ15 DQ13 DQ11 DQ9 NC CLK A11 A7 A5 VSSQ VDDQ VSSQ VDDQ Vss CKE A9 A6 A4 VDDQ VssQ VDDQ VSSQ VDD CAS# BA0 A0 A3 DQ0 DQ2 DQ4 DQ6 LDQM RAS# BA1 A1 A2 VDD DQ1 DQ3 DQ5 DQ7 WE# CS# A10 VDD Depopulated Balls PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 3 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Table 3: 256 Mb SDRAM Part Numbers PART NUMBER MT48LC64M4A2TG MT48LC64M4A2P MT48LC64M4A2FB* MT48LC64M4A2BB* MT48LC32M8A2TG MT48LC32M8A2P MT48LC32M8A2FB* MT48LC32M8A2BB* MT48LC16M16A2TG MT48LC16M16A2P MT48LC16M16A2FG MT48LC16M16A2BG ARCHITECTURE 64 Meg x 4 64 Meg x 4 64 Meg x 4 64 Meg x 4 32 Meg x 8 32 Meg x 8 32 Meg x 8 32 Meg x 8 16 Meg x 16 16 Meg x 16 16 Meg x 16 16 Meg x 16 PACKAGE 54-pin TSOP II 54-pin TSOP II 60-ball FBGA 60-ball FBGA 54-pin TSOP II 54-pin TSOP II 60-ball FBGA 60-ball FBGA 54-pin TSOP II 54-pin TSOP II 54-ball FBGA 54-ball FBGA *Actual FBGA part marking shown on pages 60 and 61. General Description The 256Mb SDRAM is a high-speed CMOS, dynamic random-access memory containing 268,435,456 bits. It is internally configured as a quadbank DRAM with a synchronous interface (all signals are registered on the positive edge of the clock signal, CLK). Each of the x4’s 67,108,864-bit banks is organized as 8,192 rows by 2,048 columns by 4 bits. Each of the x8’s 67,108,864-bit banks is organized as 8,192 rows by 1,024 columns by 8 bits. Each of the x16’s 67,108,864-bit banks is organized as 8,192 rows by 512 columns by 16 bits. Read and write accesses to the SDRAM are burst oriented; accesses start at a selected location and continue for a programmed number of locations in a programmed sequence. Accesses begin with the regis- tration of an ACTIVE command, which is then followed by a READ or WRITE command. The address bits registered coincident with the ACTIVE command are used to select the bank and row to be accessed (BA0, BA1 select the bank; A0–A12 select the row). The address bits registered coincident with the READ or WRITE command are used to select the starting column location for the burst access. The SDRAM provides for programmable READ or WRITE burst lengths of 1, 2, 4, or 8 locations, or the full page, with a burst terminate option. An auto precharge function may be enabled to provide a self-timed row precharge that is initiated at the end of the burst sequence. The 256Mb SDRAM uses an internal pipelined architecture to achieve high-speed operation. This architecture is compatible with the 2n rule of prefetch architectures, but it also allows the column address to be changed on every clock cycle to achieve a highspeed, fully random access. Precharging one bank while accessing one of the other three banks will hide the precharge cycles and provide seamless, highspeed, random-access operation. The 256Mb SDRAM is designed to operate in 3.3V memory systems. An auto refresh mode is provided, along with a power-saving, power-down mode. All inputs and outputs are LVTTL-compatible. SDRAMs offer substantial advances in DRAM operating performance, including the ability to synchronously burst data at a high data rate with automatic column-address generation, the ability to interleave between internal banks to hide precharge time and the capability to randomly change column addresses on each clock cycle during a burst access. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 4 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Table of Contents Functional Block Diagram – 64 Meg x 4 .................... 6 Functional Block Diagram – 32 Meg x 8 .................... 7 Functional Block Diagram – 16 Meg x 16 .................. 8 Pin Descriptions .......................................................... 10 Ball Descriptions .......................................................... 10 Functional Description ............................................... Initialization ........................................................... Register Definition ................................................ Mode Register ................................................... Burst Length ................................................ Burst Type ................................................... CAS Latency ................................................ Operating Mode .......................................... Write Burst Mode ........................................ Commands ................................................................... Truth Table 1 (Commands and DQM Operation) .............. Command Inhibit .................................................. No Operation (NOP) .............................................. Load mode register ................................................ Active ....................................................................... Read ....................................................................... Write ....................................................................... Precharge ................................................................ Auto Precharge ....................................................... Burst Terminate ..................................................... Auto Refresh ........................................................... Self Refresh ............................................................. Operation ..................................................................... Bank/Row Activation ............................................. Reads ....................................................................... Writes ....................................................................... Precharge ................................................................ Power-Down ........................................................... Clock Suspend ........................................................ Burst Read/Single Write ....................................... 12 12 12 12 12 13 14 14 14 15 15 16 16 16 16 16 16 16 16 17 17 17 18 18 19 25 27 27 28 28 Concurrent Auto Precharge ................................. Truth Table 2 (CKE) ...................................................... Truth Table 3 (Current State, Same Bank) ........................ Truth Table 4 (Current State, Different Bank) .................. Absolute Maximum Ratings ....................................... DC Electrical Characteristics and Operating Conditions ....................................... IDD Specifications and Conditions ............................. Capacitance .................................................................. Electrical Characteristics and Recommended AC Operating Conditions ....... Timing Waveforms Initialize and Load mode register ........................ Power-Down Mode ................................................ Clock Suspend Mode ............................................ Auto Refresh Mode ................................................ Self Refresh Mode .................................................. Reads Read – Without Auto Precharge ..................... Read – With Auto Precharge ........................... Single Read – Without Auto Precharge ......... Single Read – With Auto Precharge ............... Alternating Bank Read Accesses .................... Read – Full-Page Burst .................................... Read – DQM Operation ................................... Writes Write – Without Auto Precharge ..................... Write – With Auto Precharge ........................... Single Write - Without Auto Precharge ......... Single Write - With Auto Precharge ................ Alternating Bank Write Accesses ................... Write – Full-Page Burst .................................... Write – DQM Operation ................................... 29 31 32 34 36 36 36 37 37 AC Electrical Characteristics (Timing Table) ......... 38 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 5 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 4: Functional Block Diagram 64 Meg x 4 SDRAM CKE CLK CS# WE# CAS# RAS# CONTROL LOGIC BANK3 BANK2 BANK1 COMMAND DECODE MODE REGISTER REFRESH 13 COUNTER 12 13 ROWADDRESS MUX 13 BANK0 ROWADDRESS LATCH & DECODER 8192 BANK0 MEMORY ARRAY (8,192 x 2,048 x 4) 1 1 DQM SENSE AMPLIFIERS 4 8192 DATA OUTPUT REGISTER 2 A0-A12, BA0, BA1 ADDRESS REGISTER BANK CONTROL LOGIC 15 I/O GATING DQM MASK LOGIC READ DATA LATCH WRITE DRIVERS 4 2048 (x4) 4 DQ0DQ3 2 DATA INPUT REGISTER COLUMN DECODER COLUMNADDRESS COUNTER/ LATCH 11 11 PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 6 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 5: Functional Block Diagram 32 Meg x 8 SDRAM CKE CLK CS# WE# CAS# RAS# CONTROL LOGIC BANK3 BANK2 BANK1 COMMAND DECODE MODE REGISTER REFRESH 13 COUNTER 12 13 ROWADDRESS MUX 13 BANK0 ROWADDRESS LATCH & DECODER 8192 BANK0 MEMORY ARRAY (8,192 x 1,024 x 8) 1 1 DQM SENSE AMPLIFIERS 8 8192 DATA OUTPUT REGISTER 2 A0-A12, BA0, BA1 ADDRESS REGISTER BANK CONTROL LOGIC 15 I/O GATING DQM MASK LOGIC READ DATA LATCH WRITE DRIVERS 8 1024 (x8) 8 DQ0DQ7 2 DATA INPUT REGISTER COLUMN DECODER COLUMNADDRESS COUNTER/ LATCH 10 10 PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 7 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 6: Functional Block Diagram 16 Meg x 16 SDRAM CKE CLK CS# WE# CAS# RAS# CONTROL LOGIC BANK3 BANK2 BANK1 COMMAND DECODE MODE REGISTER REFRESH 13 COUNTER 12 13 ROWADDRESS MUX 13 BANK0 ROWADDRESS LATCH & DECODER 8192 BANK0 MEMORY ARRAY (8,192 x 512 x 16) 2 2 DQML, DQMH SENSE AMPLIFIERS 16 8192 DATA OUTPUT REGISTER 2 A0-A12, BA0, BA1 ADDRESS REGISTER BANK CONTROL LOGIC 15 I/O GATING DQM MASK LOGIC READ DATA LATCH WRITE DRIVERS 16 512 (x16) 16 DQ0DQ15 2 DATA INPUT REGISTER COLUMN DECODER COLUMNADDRESS COUNTER/ LATCH 9 9 PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 8 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Table 4: Pin Descriptions (54-pin TSOP) 54-PIN TSOP 38 SYMBOL CLK TYPE Input DESCRIPTION Clock: CLK is driven by the system clock. All SDRAM input signals are sampled on the positive edge of CLK. CLK also increments the internal burst counter and controls the output registers. Clock Enable: CKE activates (HIGH) and deactivates (LOW) the CLK signal. Deactivating the clock provides PRECHARGE POWER-DOWN and SELF REFRESH operation (all banks idle), ACTIVE POWER-DOWN (row active in any bank) or CLOCK SUSPEND operation (burst/access in progress). CKE is synchronous except after the device enters power-down and self refresh modes, where CKE becomes asynchronous until after exiting the same mode. The input buffers, including CLK, are disabled during power-down and self refresh modes, providing low standby power. CKE may be tied HIGH. Chip Select: CS# enables (registered LOW) and disables (registered HIGH) the command decoder. All commands are masked when CS# is registered HIGH. CS# provides for external bank selection on systems with multiple banks. CS# is considered part of the command code. Command Inputs: WE#, CAS#, and RAS# (along with CS#) define the command being entered. Input/Output Mask: DQM is an input mask signal for write accesses and an output enable signal for read accesses. Input data is masked when DQM is sampled HIGH during a WRITE cycle. The output buffers are placed in a High-Z state (two-clock latency) when DQM is sampled HIGH during a READ cycle. On the x4 and x8, DQML (Pin 15) is a NC and DQMH is DQM. On the x16, DQML corresponds to DQ0DQ7 and DQMH corresponds to DQ8-DQ15. DQML and DQMH are considered same state when referenced as DQM. Bank Address Inputs: BA0 and BA1 define to which bank the ACTIVE, READ, WRITE or PRECHARGE command is being applied. Address Inputs: A0-A12 are sampled during the ACTIVE command (rowaddress A0-A12) and READ/WRITE command (column-address A0-A9, A11 [x4]; A0-A9 [x8]; A0-A8 [x16]; with A10 defining auto precharge) to select one location out of the memory array in the respective bank. A10 is sampled during a PRECHARGE command to determine if all banks are to be precharged (A10 [HIGH]) or bank selected by (A10 [LOW]). The address inputs also provide the op-code during a LOAD MODE REGISTER command. 37 CKE Input 19 CS# Input 16, 17, 18 39 15, 39 WE#, CAS#, RAS# x4, x8: DQM x16: DQML, DQMU Input Input 20, 21 23-26, 29-34, 22, 35, 36 BA0, BA1 A0-A12 Input Input 2, 4, 5, 7, 8, 10, 11, 13, 42, DQ0-DQ15 x16: I/O Data Input/Output: Data bus for x16 (4, 7, 10, 13, 42, 45, 48, and 51 44, 45, 47, 48, 50, 51, 53 are NCs for x8; and 2, 4, 7, 8, 10, 13, 42, 45, 47, 48, 51, and 53 are NCs for x4). 2, 5, 8, 11, 44, 47, 50, 53 DQ0-DQ7 x8: I/O Data Input/Output: Data bus for x8 (2, 8, 47, 53 are NCs for x4). 5, 11, 44, 50 DQ0-DQ3 x4: I/O Data Input/Output: Data bus for x4. 40 NC – No Connect: This pin should be left unconnected. 3, 9, 43, 49 6, 12, 46, 52 1, 14, 27 28, 41, 54 V DD Q VSSQ VDD VSS Supply DQ Power: DQ power to the die for improved noise immunity. Supply DQ Ground: DQ ground to the die for improved noise immunity. Supply Power Supply: +3.3V ±0.3V. Supply Ground. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 9 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Table 5: Ball Descriptions (54-Ball FBGA) 54-BALL FBGA F2 SYMBOL CLK TYPE Input DESCRIPTION Clock: CLK is driven by the system clock. All SDRAM input signals are sampled on the positive edge of CLK. CLK also increments the internal burst counter and controls the output registers. Clock Enable: CKE activates (HIGH) and deactivates (LOW) the CLK signal. Deactivating the clock provides PRECHARGE POWER-DOWN and SELF REFRESH operation (all banks idle), ACTIVE POWER-DOWN (row active in any bank) or CLOCK SUSPEND operation (burst/access in progress). CKE is synchronous except after the device enters power-down and self refresh modes, where CKE becomes asynchronous until after exiting the same mode. The input buffers, including CLK, are disabled during power-down and self refresh modes, providing low standby power. CKE may be tied HIGH. Chip Select: CS# enables (registered LOW) and disables (registered HIGH) the command decoder. All commands are masked when CS# is registered HIGH. CS# provides for external bank selection on systems with multiple banks. CS# is considered part of the command code. Command Inputs: CAS#, RAS#, and WE# (along with CS#) define the command being entered. Input/Output Mask: DQM is sampled HIGH and is an input mask signal for write accesses and an output enable signal for read accesses. Input data is masked during a WRITE cycle. The output buffers are placed in a High-Z state (two-clock latency) when during a READ cycle. LDQM corresponds to DQ0–DQ7, UDQM corresponds to DQ8–DQ15. LDQM and UDQM are considered same state when referenced as DQM. Bank Address Input(s): BA0 and BA1 define to which bank the ACTIVE, READ, WRITE or PRECHARGE command is being applied. These pins also provide the op-code during a LOAD MODE REGISTER command Address Inputs: A0–A12 are sampled during the ACTIVE command (rowaddress A0–A11) and READ/WRITE command (column-address A0–A8; with A10 defining auto precharge) to select one location out of the memory array in the respective bank. A10 is sampled during a PRECHARGE command to determine if all banks are to be precharged (A10 HIGH) or bank selected by BA0, BA1 (LOW). The address inputs also provide the op-code during a LOAD MODE REGISTER command. Data Input/Output: Data bus F3 CKE Input G9 CS# Input F7, F8, F9 E8, F1 CAS#, RAS#, WE# LDQM, UDQM Input Input G7, G8 BA0, BA1 Input H7, H8, J8, J7, J3, J2, H3, H2, H1, G3, H9, G2, G1 A0–A12 Input A8, B9, B8, C9, C8, D9, D8, E9, E1, D2, D1, C2, C1, B2, B1, A2 E2 A7, B3, C7, D3 A3, B7, C3, D7 A9, E7, J9 A1, E3, J1 DQ0–DQ15 I/O NC VDDQ V SS Q VDD VSS – Supply Supply Supply Supply No Connect: These pins should be left unconnected. DQ Power: DQ power to the die for improved noise immunity. DQ Ground: DQ ground to the die for improved noise immunity. Power Supply: Voltage dependant on option. Ground. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 10 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Table 6: Ball Descriptions (60-ball FBGA) 60-BALL FBGA K2 SYMBOL CLK TYPE Input DESCRIPTION Clock: CLK is driven by the system clock. All SDRAM input signals are sampled on the positive edge of CLK. CLK also increments the internal burst counter and controls the output registers. Clock Enable: CKE activates (HIGH) and deactivates (LOW) the CLK signal. Deactivating the clock provides PRECHARGE POWER-DOWN and SELF REFRESH operation (all banks idle), ACTIVE POWER-DOWN (row active in any bank) or CLOCK SUSPEND operation (burst/access in progress). CKE is synchronous except after the device enters power-down and self refresh modes, where CKE becomes asynchronous until after exiting the same mode. The input buffers, including CLK, are disabled during power-down and self refresh modes, providing low standby power. CKE may be tied HIGH. Chip Select: CS# enables (registered LOW) and disables (registered HIGH) the command decoder. All commands are masked when CS# is registered HIGH. CS# provides for external bank selection on systems with multiple banks. CS# is considered part of the command code. Command Inputs: CAS#, RAS#, and WE# (along with CS#) define the command being entered. Input/Output Mask: DQM is sampled HIGH and is an input mask signal for write accesses and an output enable signal for read accesses. Input data is masked during a WRITE cycle. The output buffers are placed in a High-Z state (two-clock latency) when during a READ cycle. Bank Address Input(s): BA0 and BA1 define to which bank the ACTIVE, READ, WRITE or PRECHARGE command is being applied. These pins also provide the op-code during a LOAD MODE REGISTER command Address Inputs: A0–A11 are sampled during the ACTIVE command (rowaddress A0–A11) and READ/WRITE command (column-address A0–A8; with A10 defining auto precharge) to select one location out of the memory array in the respective bank. A10 is sampled during a PRECHARGE command to determine if all banks are to be precharged (A10 HIGH) or bank selected by BA0, BA1 (LOW). The address inputs also provide the op-code during a LOAD MODE REGISTER command. L2 CKE Input L8 CS# Input J8, K7, J7 J2 CAS#, RAS#, WE# DQM, Input Input M8, M7 BA0, BA1 Input N7, P8, P7, R8, R1, P2, P1, N2, N1, M2, N8, M1, L1 A0–A12 Input C7, F7, F2, C2 A8, C7, D8, F7, F2, D1, C2, A1 A1, A8, B1, B8, D1, D2, D7, D8, E1, E8, G1, G2, G7, G8, H1, H8, J1, K1, K8, L7 B1, B8, D2, D7, E1, E8, G1, G2, G7, G8, H1, H8, J1, K1, K8, L7 B7, C1, E7, F1 B2, C8, E2, F8 A7, R7 A2, H2, R2 DQ0–DQ3 DQ0–DQ7 NC (x4) I/O Data Input/Output: Data bus (x8) I/O Data Input/Output: Data bus x4 No Connect: These pins should be left unconnected. G1 is a no connect for this part but may be used as A12 in future designs. No Connect: These pins should be left unconnected. G1 is a no connect for this part but may be used as A12 in future designs. DQ Power: Isolated power to DQs for improved noise immunity. DQ Ground: Isolated ground to DQs for improved noise immunity. Power Supply: Voltage dependant on option. Ground. NC x8 VDDQ V SS Q VDD VSS Supply Supply Supply Supply PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 11 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Functional Description In general, the 256Mb SDRAMs (16 Meg x 4 x 4 banks, 8 Meg x 8 x 4 banks and 4 Meg x 16 x 4 banks) are quadbank DRAMs that operate at 3.3V and include a synchronous interface (all signals are registered on the positive edge of the clock signal, CLK). Each of the x4’s 67,108,864-bit banks is organized as 8,192 rows by 2,048 columns by 4 bits. Each of the x8’s 67,108,864-bit banks is organized as 8,192 rows by 1,024 columns by 8 bits. Each of the x16’s 67,108,864-bit banks is organized as 8,192 rows by 512 columns by 16 bits. Read and write accesses to the SDRAM are burst oriented; accesses start at a selected location and continue for a programmed number of locations in a programmed sequence. Accesses begin with the registration of an ACTIVE command, which is then followed by a READ or WRITE command. The address bits registered coincident with the ACTIVE command are used to select the bank and row to be accessed (BA0 and BA1 select the bank, A0–A12 select the row). The address bits (x4: A0–A9, A11; x8: A0–A9; x16: A0–A8) registered coincident with the READ or WRITE command are used to select the starting column location for the burst access. Prior to normal operation, the SDRAM must be initialized. The following sections provide detailed information covering device initialization, register definition, command descriptions and device operation. Register Definition Mode Register The mode register is used to define the specific mode of operation of the SDRAM. This definition includes the selection of a burst length, a burst type, a CAS latency, an operating mode and a write burst mode, as shown in Figure 7. The mode register is programmed via the LOAD MODE REGISTER command and will retain the stored information until it is programmed again or the device loses power. Mode register bits M0–M2 specify the burst length, M3 specifies the type of burst (sequential or interleaved), M4–M6 specify the CAS latency, M7 and M8 specify the operating mode, M9 specifies the write burst mode, and M10 and M11 are reserved for future use. Address A12 (M12) is undefined but should be driven LOW during loading of the mode register. The mode register must be loaded when all banks are idle, and the controller must wait the specified time before initiating the subsequent operation. Violating either of these requirements will result in unspecified operation. Burst Length Read and write accesses to the SDRAM are burst oriented, with the burst length being programmable, as shown in Figure 1. The burst length determines the maximum number of column locations that can be accessed for a given READ or WRITE command. Burst lengths of 1, 2, 4 or 8 locations are available for both the sequential and the interleaved burst types, and a fullpage burst is available for the sequential type. The full-page burst is used in conjunction with the BURST TERMINATE command to generate arbitrary burst lengths. Reserved states should not be used, as unknown operation or incompatibility with future versions may result. When a READ or WRITE command is issued, a block of columns equal to the burst length is effectively selected. All accesses for that burst take place within this block, meaning that the burst will wrap within the block if a boundary is reached. The block is uniquely selected by A1–A9, A11 (x4), A1–A9 (x8) or A1–A8 (x16) when the burst length is set to two; by A2–A9, A11 (x4), A2–A9 (x8) or A2–A8 (x16) when the burst length is set to four; and by A3–A9, A11 (x4), A3–A9 (x8) or A3–A8 (x16) when the burst length is set to eight. The remaining (least significant) address bit(s) is (are) used to select the starting location within the block. Full-page bursts wrap within the page if the boundary is reached. Initialization SDRAMs must be powered up and initialized in a predefined manner. Operational procedures other than those specified may result in undefined operation. Once power is applied to VDD and VDDQ (simultaneously) and the clock is stable (stable clock is defined as a signal cycling within timing constraints specified for the clock pin), the SDRAM requires a 100µs delay prior to issuing any command other than a COMMAND INHIBIT or NOP. Starting at some point during this 100µs period and continuing at least through the end of this period, COMMAND INHIBIT or NOP commands should be applied. Once the 100µs delay has been satisfied with at least one COMMAND INHIBIT or NOP command having been applied, a PRECHARGE command should be applied. All banks must then be precharged, thereby placing the device in the all banks idle state. Once in the idle state, two AUTO REFRESH cycles must be performed. After the AUTO REFRESH cycles are complete, the SDRAM is ready for mode register programming. Because the mode register will power up in an unknown state, it should be loaded prior to applying any operational command. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 12 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Burst Type Accesses within a given burst may be programmed to be either sequential or interleaved; this is referred to as the burst type and is selected via bit M3. The ordering of accesses within a burst is determined by the burst length, the burst type and the starting column address, as shown in Table 7. Table 7: Burst Definition Burst Starting Column Order of Accesses Within a Burst Length Address Type = Sequential Type = Interleaved A0 0 1 A1 A0 0 0 0 1 1 0 1 1 A2 A1 A0 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 1 1 0 1 1 1 0-1 1-0 0-1-2-3 1-2-3-0 2-3-0-1 3-0-1-2 0-1 1-0 0-1-2-3 1-0-3-2 2-3-0-1 3-2-1-0 0-1-2-3-4-5-6-7 1-0-3-2-5-4-7-6 2-3-0-1-6-7-4-5 3-2-1-0-7-6-5-4 4-5-6-7-0-1-2-3 5-4-7-6-1-0-3-2 6-7-4-5-2-3-0-1 7-6-5-4-3-2-1-0 2 Figure 7: Mode Register Definition A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0 Address Bus 4 12 11 10 9 8 7 6 5 4 3 BT 2 1 0 Mode Register (Mx) Reserved* WB Op Mode CAS Latency Burst Length *Should program M12, M11, M10 = “0, 0, 0” to ensure compatibility with future devices. M2 M1 M0 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 8 Burst Length M3 = 0 1 2 4 8 Reserved Reserved Reserved Full Page M3 = 1 1 2 4 8 Reserved Reserved Reserved Reserved Full Page (y) 0-1-2-3-4-5-6-7 1-2-3-4-5-6-7-0 2-3-4-5-6-7-0-1 3-4-5-6-7-0-1-2 4-5-6-7-0-1-2-3 5-6-7-0-1-2-3-4 6-7-0-1-2-3-4-5 7-0-1-2-3-4-5-6 Cn, Cn + 1, Cn + 2 n = A0-A11/9/8 Cn + 3, Cn + 4... …Cn - 1, (location 0-y) Cn… Not Supported M3 0 1 Burst Type Sequential Interleaved M6 M5 M4 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 CAS Latency Reserved Reserved 2 3 Reserved Reserved Reserved Reserved M8 0 - M7 0 - M6-M0 Defined - Operating Mode Standard Operation All other states reserved NOTE: 1. For full-page accesses: y = 2,048 (x4); y = 1,024 (x8); y = 512 (x16). 2. For a burst length of two, A1-A9, A11 (x4); A1-A9 (x8); or A1-A8 (x16) select the block-of-two burst; A0 selects the starting column within the block. 3. For a burst length of four, A2-A9, A11 (x4); A2-A9 (x8); or A2-A8 (x16) select the block-of-four burst; A0-A1 select the starting column within the block. 4. For a burst length of eight, A3-A9, A11 (x4); A3-A9 (x8); or A3-A8 (x16) select the block-of-eight burst; A0-A2 select the starting column within the block. 5. For a full-page burst, the full row is selected and A0-A9, A11 (x4); A0-A9 (x8); or A0-A8 (x16) select the starting column. 6. Whenever a boundary of the block is reached within a given sequence above, the following access wraps within the block. 7. For a burst length of one, A0-A9, A11 (x4); A0-A9 (x8); or A0-A8 (x16) select the unique column to be accessed, and mode register bit M3 is ignored. M9 0 1 Write Burst Mode Programmed Burst Length Single Location Access PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 13 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM CAS Latency The CAS latency is the delay, in clock cycles, between the registration of a READ command and the availability of the first piece of output data. The latency can be set to two or three clocks. If a READ command is registered at clock edge n, and the latency is m clocks, the data will be available by clock edge n + m. The DQs will start driving as a result of the clock edge one cycle earlier (n + m - 1), and provided that the relevant access times are met, the data will be valid by clock edge n + m. For example, assuming that the clock cycle time is such that all relevant access times are met, if a READ command is registered at T0 and the latency is programmed to two clocks, the DQs will start driving after T1 and the data will be valid by T2, as shown in Figure 8. Table 8 indicates the operating frequencies at which each CAS latency setting can be used. Reserved states should not be used as unknown operation or incompatibility with future versions may result. Operating Mode The normal operating mode is selected by setting M7 and M8 to zero; the other combinations of values for M7 and M8 are reserved for future use and/or test modes. The programmed burst length applies to both READ and WRITE bursts. Test modes and reserved states should not be used because unknown operation or incompatibility with future versions may result. Write Burst Mode When M9 = 0, the burst length programmed via M0-M2 applies to both READ and WRITE bursts; when M9 = 1, the programmed burst length applies to READ bursts, but write accesses are single-location (nonburst) accesses. Table 8: CAS Latency ALLOWABLE OPERATING FREQUENCY (MHz) Figure 8: CAS Latency T0 CLK COMMAND T1 T2 T3 SPEED -7E -75 CAS LATENCY = 2 ≤ 133 ≤ 100 CAS LATENCY = 3 ≤ 143 ≤ 133 READ NOP tLZ NOP tOH DOUT DQ tAC CAS Latency = 2 T0 CLK COMMAND T1 T2 T3 T4 READ NOP NOP tLZ NOP tOH DOUT DQ tAC CAS Latency = 3 DON’T CARE UNDEFINED PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 14 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Commands Truth Table 1 provides a quick reference of available commands. This is followed by a written description of each command. Three additional Truth Tables appear following the Operation section; these tables provide current state/next state information. Table 9: Truth Table 1 – Commands and DQM Operation (Note: 1) NAME (FUNCTION) COMMAND INHIBIT (NOP) NO OPERATION (NOP) ACTIVE (Select bank and activate row) READ (Select bank and column, and start READ burst) WRITE (Select bank and column, and start WRITE burst) BURST TERMINATE PRECHARGE (Deactivate row in bank or banks) AUTO REFRESH or SELF REFRESH (Enter self refresh mode) LOAD MODE REGISTER Write Enable/Output Enable Write Inhibit/Output High-Z NOTE: 1. 2. 3. 4. CS# RAS# CAS# WE# DQM H L L L L L L L L – – X H L H H H L L L – – X H H L L H H L L – – X H H H L L L H L – – X X X L/H8 L/H8 X X X X L H ADDR X X Bank/Row Bank/Col Bank/Col X Code X Op-Code – – DQs X X X X Valid Active X X X Active High-Z NOTES 3 4 4 5 6, 7 2 8 8 5. 6. 7. 8. CKE is HIGH for all commands shown except SELF REFRESH. A0-A11 define the op-code written to the mode register, and A12 should be driven LOW. A0-A12 provide row address, and BA0, BA1 determine which bank is made active. A0-A9, A11 (x4); A0-A9 (x8); or A0-A8 (x16) provide column address; A10 HIGH enables the auto precharge feature (nonpersistent), while A10 LOW disables the auto precharge feature; BA0, BA1 determine which bank is being read from or written to. A10 LOW: BA0, BA1 determine the bank being precharged. A10 HIGH: All banks precharged and BA0, BA1 are “Don’t Care.” This command is AUTO REFRESH if CKE is HIGH, SELF REFRESH if CKE is LOW. Internal refresh counter controls row addressing; all inputs and I/Os are “Don’t Care” except for CKE. Activates or deactivates the DQs during WRITEs (zero-clock delay) and READs (two-clock delay). PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 15 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM COMMAND INHIBIT The COMMAND INHIBIT function prevents new commands from being executed by the SDRAM, regardless of whether the CLK signal is enabled. The SDRAM is effectively deselected. Operations already in progress are not affected. inputs A0-A9; A11 (x4); A0-A9 (x8); or A0-A8 (x16) selects the starting column location. The value on input A10 determines whether or not auto precharge is used. If auto precharge is selected, the row being accessed will be precharged at the end of the WRITE burst; if auto precharge is not selected, the row will remain open for subsequent accesses. Input data appearing on the DQs is written to the memory array subject to the DQM input logic level appearing coincident with the data. If a given DQM signal is registered LOW, the corresponding data will be written to memory; if the DQM signal is registered HIGH, the corresponding data inputs will be ignored, and a WRITE will not be executed to that byte/column location. NO OPERATION (NOP) The NO OPERATION (NOP) command is used to perform a NOP to an SDRAM which is selected (CS# is LOW). This prevents unwanted commands from being registered during idle or wait states. Operations already in progress are not affected. LOAD MODE REGISTER The mode register is loaded via inputs A0–A11 (A12 should be driven LOW.) See mode register heading in the Register Definition section. The LOAD MODE REGISTER command can only be issued when all banks are idle, and a subsequent executable command cannot be issued until tMRD is met. PRECHARGE The PRECHARGE command is used to deactivate the open row in a particular bank or the open row in all banks. The bank(s) will be available for a subsequent row access a specified time (tRP) after the PRECHARGE command is issued. Input A10 determines whether one or all banks are to be precharged, and in the case where only one bank is to be precharged, inputs BA0, BA1 select the bank. Otherwise BA0, BA1 are treated as “Don’t Care.” Once a bank has been precharged, it is in the idle state and must be activated prior to any READ or WRITE commands being issued to that bank. ACTIVE The ACTIVE command is used to open (or activate) a row in a particular bank for a subsequent access. The value on the BA0, BA1 inputs selects the bank, and the address provided on inputs A0-A12 selects the row. This row remains active (or open) for accesses until a PRECHARGE command is issued to that bank. A PRECHARGE command must be issued before opening a different row in the same bank. AUTO PRECHARGE Auto precharge is a feature which performs the same individual-bank PRECHARGE function described above, without requiring an explicit command. This is accomplished by using A10 to enable auto precharge in conjunction with a specific READ or WRITE command. A PRECHARGE of the bank/row that is addressed with the READ or WRITE command is automatically performed upon completion of the READ or WRITE burst, except in the full-page burst mode, where AUTO PRECHARGE does not apply. Auto precharge is nonpersistent in that it is either enabled or disabled for each individual READ or WRITE command. Auto precharge ensures that the precharge is initiated at the earliest valid stage within a burst. The user must not issue another command to the same bank until the precharge time (tRP) is completed. This is determined as if an explicit PRECHARGE command was issued at the earliest possible time, as described for each burst type in the Operation section of this data sheet. READ The READ command is used to initiate a burst read access to an active row. The value on the BA0, BA1 inputs selects the bank, and the address provided on inputs A0-A9, A11 (x4), A0-A9 (x8), or A0-A8 (x16) selects the starting column location. The value on input A10 determines whether or not auto precharge is used. If auto precharge is selected, the row being accessed will be precharged at the end of the READ burst; if auto precharge is not selected, the row will remain open for subsequent accesses. Read data appears on the DQs subject to the logic level on the DQM inputs two clocks earlier. If a given DQM signal was registered HIGH, the corresponding DQs will be High-Z two clocks later; if the DQM signal was registered LOW, the DQs will provide valid data. WRITE The WRITE command is used to initiate a burst write access to an active row. The value on the BA0, BA1 inputs selects the bank, and the address provided on PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 BURST TERMINATE The BURST TERMINATE command is used to truncate either fixed-length or full-page bursts. The most 16 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM recently registered READ or WRITE command prior to the BURST TERMINATE command will be truncated, as shown in the Operation section of this data sheet. SELF REFRESH The SELF REFRESH command can be used to retain data in the SDRAM, even if the rest of the system is powered down. When in the self refresh mode, the SDRAM retains data without external clocking. The SELF REFRESH command is initiated like an AUTO REFRESH command except CKE is disabled (LOW). Once the SELF REFRESH command is registered, all the inputs to the SDRAM become “Don’t Care” with the exception of CKE, which must remain LOW. Once self refresh mode is engaged, the SDRAM provides its own internal clocking, causing it to perform its own AUTO REFRESH cycles. The SDRAM must remain in self refresh mode for a minimum period equal to tRAS and may remain in self refresh mode for an indefinite period beyond that. The procedure for exiting self refresh requires a sequence of commands. First, CLK must be stable (stable clock is defined as a signal cycling within timing constraints specified for the clock pin) prior to CKE going back HIGH. Once CKE is HIGH, the SDRAM must have NOP commands issued (a minimum of two clocks) for tXSR because time is required for the completion of any internal refresh in progress. Upon exiting the self refresh mode, AUTO REFRESH commands must be issued every 7.81µs or less as both SELF REFRESH and AUTO REFRESH utilize the row refresh counter. AUTO REFRESH AUTO REFRESH is used during normal operation of the SDRAM and is analogous to CAS#-BEFORE-RAS# (CBR) REFRESH in conventional DRAMs. This command is nonpersistent, so it must be issued each time a refresh is required. All active banks must be precharged prior to issuing an AUTO REFRESH command. The AUTO REFRESH command should not be issued until the minimum tRP has been met after the PRECHARGE command as shown in the operations section. The addressing is generated by the internal refresh controller. This makes the address bits “Don’t Care” during an AUTO REFRESH command. The 256Mb SDRAM requires 8,192 AUTO REFRESH cycles every 64ms (tREF), regardless of width option. Providing a distributed AUTO REFRESH command every 7.81µs will meet the refresh requirement and ensure that each row is refreshed. Alternatively, 8,192 AUTO REFRESH commands can be issued in a burst at the minimum cycle rate (tRFC), once every 64ms. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 17 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Operation Bank/Row Activation Before any READ or WRITE commands can be issued to a bank within the SDRAM, a row in that bank must be “opened.” This is accomplished via the ACTIVE command, which selects both the bank and the row to be activated (see Figure 9). After opening a row (issuing an ACTIVE command), a READ or WRITE command may be issued to that row, subject to the tRCD specification. tRCD (MIN) should be divided by the clock period and rounded up to the next whole number to determine the earliest clock edge after the ACTIVE command on which a READ or WRITE command can be entered. For example, a tRCD specification of 20ns with a 125 MHz clock (8ns period) results in 2.5 clocks, rounded to 3. This is reflected in Figure 10, which covers any case where 2 < tRCD (MIN)/tCK ≤ 3. (The same procedure is used to convert other specification limits from time units to clock cycles.) A subsequent ACTIVE command to a different row in the same bank can only be issued after the previous active row has been “closed” (precharged). The minimum time interval between successive ACTIVE commands to the same bank is defined by tRC. A subsequent ACTIVE command to another bank can be issued while the first bank is being accessed, which results in a reduction of total row-access overhead. The minimum time interval between successive ACTIVE commands to different banks is defined by t RRD. Figure 9: Activating a Specific Row in a Specific Bank CLK CKE CS# HIGH RAS# CAS# WE# A0-A12 ROW ADDRESS BA0, BA1 BANK ADDRESS Figure 10: Example: Meeting tRCD (MIN) When 2 < tRCD (MIN)/tCK < 3 T0 CLK T1 T2 T3 T4 COMMAND ACTIVE NOP NOP READ or WRITE tRCD DON’T CARE PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 18 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM READs READ bursts are initiated with a READ command, as shown in Figure 11. The starting column and bank addresses are provided with the READ command, and auto precharge is either enabled or disabled for that burst access. If auto precharge is enabled, the row being accessed is precharged at the completion of the burst. For the generic READ commands used in the following illustrations, auto precharge is disabled. During READ bursts, the valid data-out element from the starting column address will be available following the CAS latency after the READ command. Each subsequent data-out element will be valid by the next positive clock edge. Figure 12 shows general timing for each possible CAS latency setting. Upon completion of a burst, assuming no other commands have been initiated, the DQs will go High-Z. A full-page burst will continue until terminated. (At the end of the page, it will wrap to the start address and continue.) Data from any READ burst may be truncated with a subsequent READ command, and data from a fixedlength READ burst may be immediately followed by data from a READ command. In either case, a continuous flow of data can be maintained. The first data element from the new burst follows either the last element of a completed burst or the last desired data element of a longer burst that is being truncated. The new READ command should be issued x cycles before the clock edge at which the last desired data element is Figure 11: READ Command Figure 12: CAS Latency CLK T0 T1 T2 T3 CKE CS# HIGH CLK COMMAND READ NOP tLZ NOP tOH DOUT DQ tAC RAS# CAS Latency = 2 CAS# T0 T1 T2 T3 T4 CLK COMMAND WE# A0–A9, A11: x4 A0–A9: x8 A0–A8: x16 A12: x4 A11, A12: x8 A9, A11, A12: x16 ENABLE AUTO PRECHARGE READ NOP NOP tLZ NOP tOH DOUT COLUMN ADDRESS DQ tAC CAS Latency = 3 DON’T CARE UNDEFINED A10 DISABLE AUTO PRECHARGE BANK ADDRESS BA0,1 DON’T CARE PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 19 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM valid, where x e quals the CAS latency minus one. This is shown in Figure 13 for CAS latencies of two and three; data element n + 3 is either the last of a burst of four or the last desired of a longer burst. The 256Mb SDRAM uses a pipelined architecture and therefore does not require the 2n rule associated with a prefetch architecture. A READ command can be initiated on any clock cycle following a previous READ command. Fullspeed random read accesses can be performed to the same bank, as shown in Figure 14, or each subsequent READ may be performed to a different bank. Figure 13: Consecutive READ Bursts T0 CLK T1 T2 T3 T4 T5 T6 COMMAND READ NOP NOP NOP READ NOP NOP X = 1 cycle ADDRESS BANK, COL n BANK, COL b DQ CAS Latency = 2 DOUT n DOUT n+1 DOUT n+2 DOUT n+3 DOUT b T0 CLK T1 T2 T3 T4 T5 T6 T7 COMMAND READ NOP NOP NOP READ NOP NOP NOP X = 2 cycles ADDRESS BANK, COL n BANK, COL b DQ CAS Latency = 3 DOUT n DOUT n+1 DOUT n+2 DOUT n+3 DOUT b TRANSITIONING DATA DON’T CARE NOTE: Each READ command may be to any bank. DQM is LOW. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 20 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 14: Random READ Accesses T0 CLK T1 T2 T3 T4 T5 COMMAND READ READ READ READ NOP NOP ADDRESS BANK, COL n BANK, COL a BANK, COL x BANK, COL m DQ CAS Latency = 2 DOUT n DOUT a DOUT x DOUT m T0 CLK T1 T2 T3 T4 T5 T6 COMMAND READ READ READ READ NOP NOP NOP ADDRESS BANK, COL n BANK, COL a BANK, COL x BANK, COL m DQ CAS Latency = 3 DOUT n DOUT a DOUT x DOUT m TRANSITIONING DATA NOTE: Each READ command may be to any bank. DQM is LOW. DON’T CARE PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 21 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Data from any READ burst may be truncated with a subsequent WRITE command, and data from a fixedlength READ burst may be immediately followed by data from a WRITE command (subject to bus turnaround limitations). The WRITE burst may be initiated on the clock edge immediately following the last (or last desired) data element from the READ burst, provided that I/O contention can be avoided. In a given system design, there may be a possibility that the device driving the input data will go Low-Z before the SDRAM DQs go High-Z. In this case, at least a single-cycle delay should occur between the last read data and the WRITE command. The DQM input is used to avoid I/O contention, as shown in Figures 15 and 16. The DQM signal must be asserted (HIGH) at least two clocks prior to the WRITE command (DQM latency is two clocks for output buffers) to suppress data-out from the READ. Once the WRITE command is registered, the DQs will go High-Z (or remain High-Z), regardless of the state of the DQM signal; provided the DQM was active on the clock just prior to the WRITE command that truncated the READ command. If not, the second WRITE will be an invalid WRITE. For example, if DQM was LOW during T4 in Figure 10, then the WRITEs at T5 and T7 would be valid, while the WRITE at T6 would be invalid. The DQM signal must be de-asserted prior to the WRITE command (DQM latency is zero clocks for input buffers) to ensure that the written data is not masked. Figure 9 shows the case where the clock frequency allows for bus contention to be avoided without adding a NOP cycle, and Figure 16 shows the case where the additional NOP is needed. Figure 15: READ to WRITE T0 CLK DQM T1 T2 T3 T4 Figure 16: READ to WRITE with Extra Clock Cycle T0 CLK DQM T1 T2 T3 T4 T5 COMMAND ADDRESS READ NOP NOP NOP WRITE COMMAND ADDRESS READ NOP NOP NOP NOP WRITE BANK, COL n BANK, COL b BANK, COL n BANK, COL b tCK tHZ DQ DOUT n DIN b tHZ DQ DOUT n DIN b tDS tDS TRANSITIONING DATA TRANSITIONING DATA NOTE: DON’T CARE DON’T CARE NOTE: A CAS latency of three is used for illustration. The READ command may be to any bank, and the WRITE command may be to any bank. If a burst of one is used, then DQM is not required. A CAS latency of three is used for illustration. The READ command may be to any bank, and the WRITE command may be to any bank. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 22 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM A fixed-length READ burst may be followed by, or truncated with, a PRECHARGE command to the same bank (provided that auto precharge was not activated), and a full-page burst may be truncated with a PRECHARGE command to the same bank. The PRECHARGE command should be issued x cycles before the clock edge at which the last desired data element is valid, where x equals the CAS latency minus one. This is shown in Figure 17 for each possible CAS latency; data element n + 3 is either the last of a burst of four or the last desired of a longer burst. Following the PRECHARGE command, a subsequent command to the same bank cannot be issued until tRP is met. Note that part of the row precharge time is hidden during the access of the last data element(s). In the case of a fixed-length burst being executed to completion, a PRECHARGE command issued at the optimum time (as described above) provides the same operation that would result from the same fixed-length burst with auto precharge. The disadvantage of the Figure 17: READ to PRECHARGE T0 CLK t RP T1 T2 T3 T4 T5 T6 T7 COMMAND READ NOP NOP NOP PRECHARGE X = 1 cycle NOP NOP ACTIVE ADDRESS BANK a, COL n BANK (a or all) BANK a, ROW DQ CAS Latency = 2 DOUT n DOUT n+1 DOUT n+2 DOUT n+3 T0 CLK T1 T2 T3 T4 T5 T6 T7 t RP COMMAND READ NOP NOP NOP PRECHARGE NOP NOP ACTIVE X = 2 cycles ADDRESS BANK a, COL n BANK (a or all) BANK a, ROW DQ CAS Latency = 3 DOUT n DOUT n+1 DOUT n+2 DOUT n+3 TRANSITIONING DATA NOTE: DQM is LOW. DON’T CARE PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 23 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM PRECHARGE command is that it requires that the command and address buses be available at the appropriate time to issue the command; the advantage of the PRECHARGE command is that it can be used to truncate fixed-length or full-page bursts. Full-page READ bursts can be truncated with the BURST TERMINATE command, and fixed-length READ bursts may be truncated with a BURST TERMINATE command, provided that auto precharge was not activated. The BURST TERMINATE command should be issued x cycles before the clock edge at which the last desired data element is valid, where x equals the CAS latency minus one. This is shown in Figure 18 for each possible CAS latency; data element n + 3 is the last desired data element of a longer burst. Figure 18: Terminating a READ Burst T0 CLK T1 T2 T3 T4 T5 T6 COMMAND READ NOP NOP NOP BURST TERMINATE X = 1 cycle NOP NOP ADDRESS BANK, COL n DQ CAS Latency = 2 DOUT n DOUT n+1 DOUT n+2 DOUT n+3 T0 CLK T1 T2 T3 T4 T5 T6 T7 COMMAND READ NOP NOP NOP BURST TERMINATE NOP NOP NOP X = 2 cycles ADDRESS BANK, COL n DQ CAS Latency = 3 DOUT n DOUT n+1 DOUT n+2 DOUT n+3 TRANSITIONING DATA NOTE: DQM is LOW. DON’T CARE PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 24 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM WRITEs WRITE bursts are initiated with a WRITE command, as shown in Figure 19. The starting column and bank addresses are provided with the WRITE command, and auto precharge is either enabled or disabled for that access. If auto precharge is enabled, the row being accessed is precharged at the completion of the burst. For the generic WRITE commands used in the following illustrations, auto precharge is disabled. During WRITE bursts, the first valid data-in element will be registered coincident with the WRITE command. Subsequent data elements will be registered on each successive positive clock edge. Upon completion of a fixed-length burst, assuming no other commands have been initiated, the DQs will remain High-Z and any additional input data will be ignored (see Figure 20). A full-page burst will continue until terminated. (At the end of the page, it will wrap to the start address and continue.) Data for any WRITE burst may be truncated with a subsequent WRITE command, and data for a fixedlength WRITE burst may be immediately followed by data for a WRITE command. The new WRITE command can be issued on any clock following the previous WRITE command, and the data provided coincident with the new command applies to the new command. An example is shown in Figure 21. Data n + 1 is either the last of a burst of two or the last desired of a longer burst. The 256Mb SDRAM uses a pipelined architecture and therefore does not require the 2n rule associated with a prefetch architecture. A WRITE command can be initiated on any clock cycle following a previous WRITE command. Full-speed random write accesses within a page can be performed to the same bank, as shown in Figure 22, or each subsequent WRITE may be performed to a different bank. Data for any WRITE burst may be truncated with a subsequent READ command, and data for a fixedlength WRITE burst may be immediately followed by a READ command. Once the READ command is regis- Figure 20: WRITE Burst T0 CLK T1 T2 T3 COMMAND WRITE NOP NOP NOP ADDRESS BANK, COL n Figure 19: WRITE Command DQ CLK CKE CS# HIGH DIN n DIN n+1 TRANSITIONING DATA DON’T CARE NOTE: Burst length = 2. DQM is LOW. RAS# Figure 21: WRITE to WRITE T0 CLK T1 T2 CAS# WE# A0-A9, A11: x4 A0-A9: x8 A0-A8: x16 A12: x4 A11, A12: x8 A9, A11, A12: x16 ENABLE AUTO PRECHARGE COLUMN ADDRESS COMMAND WRITE NOP WRITE ADDRESS BANK, COL n BANK, COL b A10 DISABLE AUTO PRECHARGE DQ DIN n DIN n+1 DIN b BA0,1 BANK ADDRESS TRANSITIONING DATA DON’T CARE DON’T CARE NOTE: DQM is LOW. Each WRITE command may be to any bank. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 25 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM tered, the data inputs will be ignored, and WRITEs will not be executed. An example is shown in Figure 23. Data n + 1 is either the last of a burst of two or the last desired of a longer burst. Data for a fixed-length WRITE burst may be followed by, or truncated with, a PRECHARGE command to the same bank (provided that auto precharge was not activated), and a full-page WRITE burst may be truncated with a PRECHARGE command to the same bank. The PRECHARGE command should be issued tWR after the clock edge at which the last desired input data element is registered. The auto precharge mode requires a tWR of at least one clock plus time, regardless of frequency. In addition, when truncating a WRITE burst, the DQM signal must be used to mask input data for the clock edge prior to, and the clock edge coincident with, the PRECHARGE command. An example is shown in Figure 24. Data n + 1 is either the last of a burst of two or the last desired of a longer burst. Following the PRECHARGE command, a subsequent command to the same bank cannot be issued until tRP is met. The precharge can be issued coincident with the first coincident clock edge (T2 in Figure 24) on an A1 Version and with the second clock on an A2 Version (Figure 24.) In the case of a fixed-length burst being executed to completion, a PRECHARGE command issued at the optimum time (as described above) provides the same operation that would result from the same fixed-length burst with auto precharge. The disadvantage of the PRECHARGE command is that it requires that the command and address buses be available at the appropriate time to issue the command; the advantage of the PRECHARGE command is that it can be used to truncate fixed-length or full-page bursts. Fixed-length or full-page WRITE bursts can be truncated with the BURST TERMINATE command. When truncating a WRITE burst, the input data applied coincident with the BURST TERMINATE command will be Figure 22: Random WRITE Cycles T0 CLK T1 T2 T3 COMMAND WRITE WRITE WRITE WRITE Figure 24: WRITE To PRECHARGE ADDRESS BANK, COL n BANK, COL a BANK, COL x BANK, COL m T0 CLK T1 T2 T3 T4 T5 T6 DQ DIN n DIN a DIN x DIN m tWR @ tCLK ≥ 15ns TRANSITIONING DATA DON’T CARE DQM t RP COMMAND WRITE NOP PRECHARGE NOP NOP ACTIVE NOP ADDRESS BANK a, COL n t WR BANK (a or all) BANK a, ROW Figure 23: WRITE To READ T0 CLK T1 T2 T3 T4 T5 DQ DIN n DIN n+1 tWR = tCLK < 15ns DQM t RP COMMAND WRITE NOP READ NOP NOP NOP COMMAND BANK, COL n WRITE NOP NOP PRECHARGE NOP NOP ACTIVE ADDRESS BANK, COL b ADDRESS BANK a, COL n t WR BANK (a or all) BANK a, ROW DQ DIN n DIN n+1 DOUT b DOUT b+1 DQ DIN n DIN n+1 TRANSITIONING DATA DON’T CARE TRANSITIONING DATA DON’T CARE NOTE: DQM could remain LOW in this example if the WRITE burst is a fixed length of two. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 26 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM ignored. The last data written (provided that DQM is LOW at that time) will be the input data applied one clock previous to the BURST TERMINATE command. This is shown in Figure 25, where data n is the last desired data element of a longer burst. open row in all banks. The bank(s) will be available for a subsequent row access some specified time (tRP) after the PRECHARGE command is issued. Input A10 determines whether one or all banks are to be precharged, and in the case where only one bank is to be precharged, inputs BA0, BA1 select the bank. When all banks are to be precharged, inputs BA0, BA1 are treated as “Don’t Care.” Once a bank has been precharged, it is in the idle state and must be activated prior to any READ or WRITE commands being issued to that bank. PRECHARGE The PRECHARGE command (see Figure 26) is used to deactivate the open row in a particular bank or the Figure 25: Terminating a WRITE Burst T0 CLK T1 T2 Power-Down Power-down occurs if CKE is registered LOW coincident with a NOP or COMMAND INHIBIT when no accesses are in progress. If power-down occurs when all banks are idle, this mode is referred to as precharge power-down; if power-down occurs when there is a row active in any bank, this mode is referred to as active power-down. Entering power-down deactivates the input and output buffers, excluding CKE, for maximum power savings while in standby. The device may not remain in the power-down state longer than the refresh period (64ms) since no refresh operations are performed in this mode. The power-down state is exited by registering a NOP or COMMAND INHIBIT and CKE HIGH at the desired clock edge (meeting tCKS). See Figure 27. COMMAND WRITE BURST TERMINATE NEXT COMMAND ADDRESS BANK, COL n (ADDRESS) DQ DIN n (DATA) TRANSITIONING DATA NOTE: DQMs are LOW. DON’T CARE Figure 26: PRECHARGE Command CLK CKE CS# HIGH Figure 27: Power-Down CLK tCKS CKE (( )) (( )) > tCKS (( )) RAS# COMMAND NOP (( )) (( )) NOP ACTIVE All banks idle Input buffers gated off CAS# tRCD tRAS tRC DON’T CARE Enter power-down mode. WE# Exit power-down mode. A0-A9, A11, A12 All Banks A10 Bank Selected BA0, BA1 BANK ADDRESS PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 27 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM CLOCK SUSPEND The clock suspend mode occurs when a column access/burst is in progress and CKE is registered LOW. In the clock suspend mode, the internal clock is deactivated, “freezing” the synchronous logic. For each positive clock edge on which CKE is sampled LOW, the next internal positive clock edge is suspended. Any command or data present on the input pins at the time of a suspended internal clock edge is ignored; any data present on the DQ pins remains driven; and burst counters are not incremented, as long as the clock is suspended. (See examples in Figures 28and 29.) Clock suspend mode is exited by registering CKE HIGH; the internal clock and related operation will resume on the subsequent positive clock edge. BURST READ/SINGLE WRITE The burst read/single write mode is entered by programming the write burst mode bit (M9) in the mode register to a logic 1. In this mode, all WRITE commands result in the access of a single column location (burst of one), regardless of the programmed burst length. READ commands access columns according to the programmed burst length and sequence, just as in the normal mode of operation (M9 = 0). Figure 28: Clock Suspend During WRITE Burst T0 CLK T1 T2 T3 T4 T5 Figure 29: Clock Suspend During READ Burst T0 CLK T1 T2 T3 T4 T5 T6 CKE CKE INTERNAL CLOCK INTERNAL CLOCK NOP WRITE NOP NOP COMMAND COMMAND READ NOP NOP NOP NOP NOP ADDRESS BANK, COL n ADDRESS DIN n+1 DIN n+2 BANK, COL n DIN DIN n DQ DOUT n DOUT n+1 DOUT n+2 DOUT n+3 TRANSITIONING DATA DON’T CARE TRANSITIONING DATA DON’T CARE NOTE: For this example, CAS latency = 2, burst length = 4 or greater, and DQM is LOW. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 28 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM CONCURRENT AUTO PRECHARGE An access command (READ or WRITE) to another bank while an access command with auto precharge enabled is executing is not allowed by SDRAMs, unless the SDRAM supports CONCURRENT AUTO PRECHARGE. Micron SDRAMs support CONCURRENT AUTO PRECHARGE. Four cases where CONCURRENT AUTO PRECHARGE occurs are defined below. READ with Auto Precharge 1. Interrupted by a READ (with or without auto precharge): A READ to bank m will interrupt a READ on bank n, CAS latency later. The PRECHARGE to bank n will begin when the READ to bank m is registered (Figure 30). 2. Interrupted by a WRITE (with or without auto precharge): A WRITE to bank m will interrupt a READ on bank n when registered. DQM should be used two clocks prior to the WRITE command to prevent bus contention. The PRECHARGE to bank n will begin when the WRITE to bank m is registered (Figure 31). Figure 30: READ With Auto Precharge Interrupted by a READ T0 CLK READ - AP BANK n READ - AP BANK m T1 T2 T3 T4 T5 T6 T7 COMMAND BANK n NOP NOP NOP NOP NOP NOP Page Active READ with Burst of 4 Interrupt Burst, Precharge t RP - BANK n Idle tRP - BANK m Precharge Internal States BANK m Page Active READ with Burst of 4 ADDRESS DQ BANK n, COL a BANK m, COL d DOUT a DOUT a+1 DOUT d DOUT d+1 CAS Latency = 3 (BANK n) CAS Latency = 3 (BANK m) NOTE: DQM is LOW. TRANSITIONING DATA DON’T CARE Figure 31: READ With Auto Precharge Interrupted by a WRITE T0 CLK READ - AP BANK n Page Active WRITE - AP BANK m T1 T2 T3 T4 T5 T6 T7 COMMAND BANK n NOP NOP NOP NOP NOP NOP READ with Burst of 4 Interrupt Burst, Precharge tRP - BANK n Idle t WR - BANK m Write-Back Internal States BANK m BANK n, COL a Page Active WRITE with Burst of 4 ADDRESS 1 DQM DQ BANK m, COL d DOUT a CAS Latency = 3 (BANK n) DIN d DIN d+1 DIN d+2 DIN d+3 TRANSITIONING DATA DON’T CARE NOTE: 1. DQM is HIGH at T2 to prevent DOUT-a+1 from contending with DIN-d at T4. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 29 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM WRITE with Auto Precharge 3. Interrupted by a READ (with or without auto precharge): A READ to bank m will interrupt a WRITE on bank n when registered, with the data-out appearing CAS latency later. The PRECHARGE to bank n will begin after tWR is met, where tWR begins when the READ to bank m is registered. The last valid WRITE to bank n will be data-in registered one clock prior to the READ to bank m (Figure 32). 4. Interrupted by a WRITE (with or without auto precharge): A WRITE to bank m will interrupt a WRITE on bank n w hen registered. The PRECHARGE to bank n will begin after tWR is met, where tWR begins when the WRITE to bank m is registered. The last valid data WRITE to bank n will be data registered one clock prior to a WRITE to bank m (Figure 33). Figure 32: WRITE With Auto Precharge Interrupted by a READ T0 CLK WRITE - AP BANK n READ - AP BANK m T1 T2 T3 T4 T5 T6 T7 COMMAND BANK n NOP NOP NOP NOP NOP NOP Page Active WRITE with Burst of 4 Interrupt Burst, Write-Back tWR - BANK n Precharge tRP - BANK n tRP - BANK m Internal States BANK m Page Active READ with Burst of 4 ADDRESS DQ BANK n, COL a DIN a DIN a+1 BANK m, COL d DOUT d CAS Latency = 3 (BANK m) DOUT d+1 NOTE: 1. DQM is LOW. TRANSITIONING DATA DON’T CARE Figure 33: WRITE With Auto Precharge Interrupted by a WRITE T0 CLK WRITE - AP BANK n WRITE - AP BANK m T1 T2 T3 T4 T5 T6 T7 COMMAND BANK n NOP NOP NOP NOP NOP NOP Page Active WRITE with Burst of 4 Interrupt Burst, Write-Back tWR - BANK n Precharge tRP - BANK n t WR - BANK m Write-Back Internal States BANK m Page Active WRITE with Burst of 4 ADDRESS DQ BANK n, COL a DIN a DIN a+1 DIN a+2 BANK m, COL d DIN d DIN d+1 DIN d+2 DIN d+3 TRANSITIONING DATA NOTE: 1. DQM is LOW. DON’T CARE PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 30 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Table 10: Truth Table 2 – CKE (Notes: 1-4) CKEn-1 CKEn L L CURRENT STATE Power-Down Self Refresh Clock Suspend L H Power-Down Self Refresh Clock Suspend H L All Banks Idle All Banks Idle Reading or Writing H NOTE: 1. 2. 3. 4. 5. COMMANDn X X X COMMAND INHIBIT or NOP COMMAND INHIBIT or NOP X COMMAND INHIBIT or NOP AUTO REFRESH VALID See Truth Table 3 ACTIONn Maintain Power-Down Maintain Self Refresh Maintain Clock Suspend Exit Power-Down Exit Self Refresh Exit Clock Suspend Power-Down Entry Self Refresh Entry Clock Suspend Entry NOTES 5 6 7 H CKEn is the logic state of CKE at clock edge n; CKEn-1 was the state of CKE at the previous clock edge. Current state is the state of the SDRAM immediately prior to clock edge n. COMMANDn is the command registered at clock edge n, and ACTIONn is a result of COMMANDn. All states and sequences not shown are illegal or reserved. Exiting power-down at clock edge n will put the device in the all banks idle state in time for clock edge n + 1 (provided that tCKS is met). 6. Exiting self refresh at clock edge n will put the device in the all banks idle state once tXSR is met. COMMAND INHIBIT or NOP commands should be issued on any clock edges occurring during the tXSR period. A minimum of two NOP commands must be provided during tXSR period. 7. After exiting clock suspend at clock edge n, the device will resume operation and recognize the next command at clock edge n + 1. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 31 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Table 11: Truth Table 3 – Current State Bank n, Command to Bank n (Notes: 1-6; notes appear below and on next page) CURRENT STATE Any CS# RAS# CAS# WE# H L L Idle L L L L Row Active Read (Auto Precharge Disabled) Write (Auto Precharge Disabled) L L L L L L L L L L X H L L L L H H L H H L H H H L H X H H L L H L L H L L H H L L H H X H H H L L H L L H L L L H L L L COMMAND (ACTION) COMMAND INHIBIT (NOP/Continue previous operation) NO OPERATION (NOP/Continue previous operation) ACTIVE (Select and activate row) AUTO REFRESH LOAD MODE REGISTER PRECHARGE READ (Select column and start READ burst) WRITE (Select column and start WRITE burst) PRECHARGE (Deactivate row in bank or banks) READ (Select column and start new READ burst) WRITE (Select column and start WRITE burst) PRECHARGE (Truncate READ burst, start PRECHARGE) BURST TERMINATE READ (Select column and start READ burst) WRITE (Select column and start new WRITE burst) PRECHARGE (Truncate WRITE burst, start PRECHARGE) BURST TERMINATE 7 7 11 10 10 8 10 10 8 9 10 10 8 9 NOTES NOTE: 1. This table applies when CKEn-1 was HIGH and CKEn is HIGH (see Truth Table 2) and after tXSR has been met (if the previous state was self refresh). 2. This table is bank-specific, except where noted, i.e., the current state is for a specific bank and the commands shown are those allowed to be issued to that bank when in that state. Exceptions are covered in the notes below. 3. Current state definitions: Idle: The bank has been precharged, and tRP has been met. Row Active: A row in the bank has been activated, and tRCD has been met. No data bursts/accesses and no register accesses are in progress. Read: A READ burst has been initiated, with auto precharge disabled, and has not yet terminated or been terminated. Write: A WRITE burst has been initiated, with auto precharge disabled, and has not yet terminated or been terminated. 4. The following states must not be interrupted by a command issued to the same bank. COMMAND INHIBIT or NOP commands, or allowable commands to the other bank should be issued on any clock edge occurring during these states. Allowable commands to the other bank are determined by its current state and Truth Table 3, and according to Truth Table 4. Precharging: Starts with registration of a PRECHARGE command and ends when tRP is met. Once tRP is met, the bank will be in the idle state. Row Activating: Starts with registration of an ACTIVE command and ends when tRCD is met. Once tRCD is met, the bank will be in the row active state. Read w/Auto Precharge Enabled: Starts with registration of a READ command with auto precharge enabled and ends when tRP has been met. Once tRP is met, the bank will be in the idle state. Write w/Auto Precharge Enabled: Starts with registration of a WRITE command with auto precharge enabled and ends when tRP has been met. Once tRP is met, the bank will be in the idle state. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 32 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM NOTE (continued): 5. The following states must not be interrupted by any executable command; COMMAND INHIBIT or NOP commands must be applied on each positive clock edge during these states. Refreshing: Starts with registration of an AUTO REFRESH command and ends when tRC is met. Once tRC is met, the SDRAM will be in the all banks idle state. Accessing Mode Register: Starts with registration of a LOAD MODE REGISTER command and ends when tMRD has been met. Once tMRD is met, the SDRAM will be in the all banks idle state. Precharging All: Starts with registration of a PRECHARGE ALL command and ends when tRP is met. Once tRP is met, all banks will be in the idle state. 6. All states and sequences not shown are illegal or reserved. 7. Not bank-specific; requires that all banks are idle. 8. May or may not be bank-specific; if all banks are to be precharged, all must be in a valid state for precharging. 9. Not bank-specific; BURST TERMINATE affects the most recent READ or WRITE burst, regardless of bank. 10. READs or WRITEs listed in the Command (Action) column include READs or WRITEs with auto precharge enabled and READs or WRITEs with auto precharge disabled. 11. Does not affect the state of the bank and acts as a NOP to that bank. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 33 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Table 12: Truth Table 4 – Current State Bank n, Command to Bank m (Notes: 1-6; notes appear below and on next page) CURRENT STATE Any Idle Row Activating, Active, or Precharging Read (Auto Precharge Disabled) Write (Auto Precharge Disabled) Read (With Auto Precharge) Write (With Auto Precharge) CS# RAS# CAS# WE# H L X L L L L L L L L L L L L L L L L L L L L X H X L H H L L H H L L H H L L H H L L H H L X H X H L L H H L L H H L L H H L L H H L L H X H X H H L L H H L L H H L L H H L L H H L L COMMAND (ACTION) COMMAND INHIBIT (NOP/Continue previous operation) NO OPERATION (NOP/Continue previous operation) Any Command Otherwise Allowed to Bank m ACTIVE (Select and activate row) READ (Select column and start READ burst) WRITE (Select column and start WRITE burst) PRECHARGE ACTIVE (Select and activate row) READ (Select column and start new READ burst) WRITE (Select column and start WRITE burst) PRECHARGE ACTIVE (Select and activate row) READ (Select column and start READ burst) WRITE (Select column and start new WRITE burst) PRECHARGE ACTIVE (Select and activate row) READ (Select column and start new READ burst) WRITE (Select column and start WRITE burst) PRECHARGE ACTIVE (Select and activate row) READ (Select column and start READ burst) WRITE (Select column and start new WRITE burst) PRECHARGE 7, 8, 16 7, 8, 17 9 7, 8, 14 7, 8, 15 9 7, 12 7, 13 9 7, 10 7, 11 9 7 7 NOTES NOTE: 1. This table applies when CKE n-1 was HIGH and CKEn is HIGH (see Truth Table 2) and after tXSR has been met (if the previous state was self refresh). 2. This table describes alternate bank operation, except where noted; i.e., the current state is for bank n and the commands shown are those allowed to be issued to bank m (assuming that bank m is in such a state that the given command is allowable). Exceptions are covered in the notes below. 3. Current state definitions: Idle: The bank has been precharged, and tRP has been met. Row Active: A row in the bank has been activated, and tRCD has been met. No data bursts/accesses and no register accesses are in progress. Read: A READ burst has been initiated, with auto precharge disabled, and has not yet terminated or been terminated. Write: A WRITE burst has been initiated, with auto precharge disabled, and has not yet terminated or been terminated. Read w/Auto Precharge Enabled: Starts with registration of a READ command with auto precharge enabled, and ends when tRP has been met. Once tRP is met, the bank will be in the idle state. Write w/Auto Precharge Enabled: Starts with registration of a WRITE command with auto precharge enabled, and ends when tRP has been met. Once tRP is met, the bank will be in the idle state. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 34 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM NOTE (continued): 4. AUTO REFRESH, SELF REFRESH and LOAD MODE REGISTER commands may only be issued when all banks are idle. 5. A BURST TERMINATE command cannot be issued to another bank; it applies to the bank represented by the current state only. 6. All states and sequences not shown are illegal or reserved. 7. READs or WRITEs to bank m listed in the Command (Action) column include READs or WRITEs with auto precharge enabled and READs or WRITEs with auto precharge disabled. 8. CONCURRENT AUTO PRECHARGE: Bank n will initiate the auto precharge command when its burst has been interrupted by bank m’s burst. 9. Burst in bank n continues as initiated. 10. For a READ without auto precharge interrupted by a READ (with or without auto precharge), the READ to bank m will interrupt the READ on bank n, CAS latency later (Figure 7). 11. For a READ without auto precharge interrupted by a WRITE (with or without auto precharge), the WRITE to bank m will interrupt the READ on bank n when registered (Figures 9 and 10). DQM should be used one clock prior to the WRITE command to prevent bus contention. 12. For a WRITE without auto precharge interrupted by a READ (with or without auto precharge), the READ to bank m will interrupt the WRITE on bank n when registered (Figure 17), with the data-out appearing CAS latency later. The last valid WRITE to bank n will be data-in registered one clock prior to the READ to bank m. 13. For a WRITE without auto precharge interrupted by a WRITE (with or without auto precharge), the WRITE to bank m will interrupt the WRITE on bank n when registered (Figure 15). The last valid WRITE to bank n will be data-in registered one clock prior to the READ to bank m. 14. For a READ with auto precharge interrupted by a READ (with or without auto precharge), the READ to bank m will interrupt the READ on bank n, CAS latency later. The PRECHARGE to bank n will begin when the READ to bank m is registered (Figure 24). 15. For a READ with auto precharge interrupted by a WRITE (with or without auto precharge), the WRITE to bank m will interrupt the READ on bank n when registered. DQM should be used two clocks prior to the WRITE command to prevent bus contention. The PRECHARGE to bank n will begin when the WRITE to bank m is registered (Figure 25). 16. For a WRITE with auto precharge interrupted by a READ (with or without auto precharge), the READ to bank m will interrupt the WRITE on bank n when registered, with the data-out appearing CAS latency later. The PRECHARGE to bank n will begin after tWR is met, where tWR begins when the READ to bank m is registered. The last valid WRITE to bank n will be data-in registered one clock prior to the READ to bank m (Figure 26). 17. For a WRITE with auto precharge interrupted by a WRITE (with or without auto precharge), the WRITE to bank m will interrupt the WRITE on bank n when registered. The PRECHARGE to bank n will begin after tWR is met, where tWR begins when the WRITE to bank m is registered. The last valid WRITE to bank n will be data registered one clock prior to the WRITE to bank m (Figure 27). PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 35 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Absolute Maximum Ratings Stresses greater than those listed may cause permanent damage to the device. This is a stress rating only, and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. Voltage on VDD, VDDQ Supply Relative to VSS ....................................... -1V to +4.6V Voltage on Inputs, NC or I/O Pins Relative to VSS ....................................... -1V to +4.6V Operating Temperature, TA (commercial) ....................................... 0°C to +70°C Operating Temperature, TA (industrial “IT”) ............................. -40°C to +85°C Storage Temperature (plastic) ............ -55°C to +150°C Power Dissipation ........................................................ 1W Table 13: DC Electrical Characteristics and Operating Conditions (Notes: 1, 5, 6; notes appear on page 39); (VDD, VDDQ = +3.3V ±0.3V) PARAMETER/CONDITION Supply Voltage Input High Voltage: Logic 1; All inputs Input Low Voltage: Logic 0; All inputs Input Leakage Current: Any input 0V ≤ VIN ≤ VDD (All other pins not under test = 0V) Output Leakage Current: DQs are disabled; 0V ≤ VOUT ≤ VDDQ Output Levels: Output High Voltage (IOUT = -4mA) Output Low Voltage (IOUT = 4mA) SYMBOL VDD, VDDQ VIH VIL II IOZ MIN 3 2 -0.3 -5 -5 MAX 3.6 VDD + 0.3 0.8 5 5 UNITS NOTES V V V µA µA 22 22 VOH VOL 2.4 – – 0.4 V V Table 14: IDD Specifications and Conditions (Notes: 1, 5, 6, 11, 13; notes appear on page 39); (VDD, VDDQ = +3.3V ±0.3V) MAX PARAMETER/CONDITION Operating Current: Active Mode; Burst = 2; READ or WRITE; tRC = tRC (MIN) Standby Current: Power-Down Mode; All banks idle; CKE = LOW Standby Current: Active Mode; CKE = HIGH; CS# = HIGH; All banks active after tRCD met; No accesses in progress Operating Current: Burst Mode; Page burst; READ or WRITE; All banks active Auto Refresh Current CS# = HIGH; CKE = HIGH SELF REFRESH CURRENT: CKE ≤ 0.2V tRFC tRFC SYMBOL -7E IDD1 IDD2 IDD3 135 2 40 -75 UNITS NOTES 125 2 40 mA mA mA 3, 18, 19, 32 32 3, 12, 19, 32 3, 18, 19, 32 3, 12, 18, 19, 32, 33 4 IDD4 = tRFC (MIN) = 7.81 µs IDD5 IDD6 IDD7 IDD7 135 285 3.5 2.5 1.5 135 270 3.5 2.5 1.5 mA mA mA mA mA Standard Low power (L) PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 36 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Table 15: Capacitance (Note: 2; notes appear on page 39) PARAMETER - TSOP “TG” Package Input Capacitance: CLK Input Capacitance: All other input-only pins Input/Output Capacitance: DQs PARAMETER - FBGA “FB” and “FG” Package Input Capacitance: CLK Input Capacitance: All other input-only pins Input/Output Capacitance: DQs SYMBOL CI1 CI2 CIO SYMBOL CI1 CI2 CIO MIN 2.5 2.5 4.0 MIN 1.5 1.5 3.0 MAX 3.5 3.8 6.0 MAX 3.5 3.8 6.0 UNITS NOTES pF pF pF 29 30 31 UNITS NOTES pF pF pF 34 35 36 Table 16: Electrical Characteristics and Recommended AC Operating Conditions (Notes: 5, 6, 8, 9, 11; notes appear on page 39) AC CHARACTERISTICS PARAMETER Access time from CLK (pos. edge) Address hold time Address setup time CLK high-level width CLK low-level width Clock cycle time CKE hold time CKE setup time CS#, RAS#, CAS#, WE#, DQM hold time CS#, RAS#, CAS#, WE#, DQM setup time Data-in hold time Data-in setup time Data-out high-impedance time Data-out low-impedance time Data-out hold time (load) Data-out hold time (no load) ACTIVE to PRECHARGE command ACTIVE to ACTIVE command period ACTIVE to READ or WRITE delay Refresh period (8,192 rows) AUTO REFRESH period PRECHARGE command period ACTIVE bank a to ACTIVE bank b command Transition time WRITE recovery time -7E -75 SYMBOL MIN MAX MIN MAX tAC(3) 5.4 5.4 tAC(2) 5.4 6 tAH 0.8 0.8 tAS 1.5 1.5 tCH 2.5 2.5 tCL 2.5 2.5 tCK(3) 7 7.5 tCK(2) 7.5 10 tCKH 0.8 0.8 tCKS 1.5 1.5 tCMH 0.8 0.8 tCMS 1.5 1.5 tDH 0.8 0.8 tDS 1.5 1.5 tHZ(3) 5.4 5.4 tHZ(2) 5.4 6 t LZ 1 1 tOH 3 3 tOH 1.8 1.8 N tRAS 37 120,000 44 120,000 tRC 60 66 tRCD 15 20 tREF 64 64 tRFC 66 66 tRP 15 20 tRRD 14 15 tT 0.3 1.2 0.3 1.2 tWR 1 CLK+ 1 CLK+ 7ns 7.5ns tXSR CL = 3 CL = 2 CL = 3 CL = 2 CL = 3 CL = 2 UNITS ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ms ns ns ns ns ns ns ns NOTES 27 23 23 37 10 10 28 7 24 25 20 Exit SELF REFRESH to ACTIVE command 14 67 15 75 PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 37 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Table 17: AC Functional Characteristics (Notes: 5, 6, 7, 8, 9, 11; notes appear on page 39) PARAMETER READ/WRITE command to READ/WRITE command CKE to clock disable or power-down entry mode CKE to clock enable or power-down exit setup mode DQM to input data delay DQM to data mask during WRITEs DQM to data high-impedance during READs WRITE command to input data delay Data-in to ACTIVE command Data-in to PRECHARGE command Last data-in to burst STOP command Last data-in to new READ/WRITE command Last data-in to PRECHARGE command LOAD MODE REGISTER command to ACTIVE or REFRESH command Data-out to high-impedance from PRECHARGE command SYMBOL tCCD tCKED tPED tDQD tDQM tDQZ tDWD tDAL tDPL tBDL tCDL tRDL tMRD tROH(3) tROH(2) -7E 1 1 1 0 0 2 0 4 2 1 1 2 2 3 2 -75 1 1 1 0 0 2 0 5 2 1 1 2 2 3 2 UNITS tCK tCK tCK tCK tCK tCK tCK tCK tCK tCK tCK tCK tCK tCK tCK NOTES 17 14 14 17 17 17 17 15, 21 16, 21 17 17 16, 21 26 17 17 CL = 3 CL = 2 PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 38 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Notes 1. 2. 3. All voltages referenced to VSS. This parameter is sampled. VDD , V DDQ = +3.3V; f = 1 MHz, TA = 25°C; pin under test biased at 1.4V. IDD is dependent on output loading and cycle rates. Specified values are obtained with minimum cycle time and the outputs open. Enables on-chip refresh and address counters. The minimum specifications are used only to indicate cycle time at which proper operation over the full temperature range is ensured; (0°C ≤ TA ≤ +70°C for commercial) and (-40°C ≤ TA ≤ +85°C for IT). An initial pause of 100µs is required after powerup, followed by two AUTO REFRESH commands, before proper device operation is ensured. (VDD and VDDQ must be powered up simultaneously. VSS and VSSQ must be at same potential.) The two AUTO REFRESH command wake-ups should be repeated any time the tREF refresh requirement is exceeded. AC characteristics assume tT = 1ns. In addition to meeting the transition rate specification, the clock and CKE must transit between VIH and VIL (or between VIL and VIH) in a monotonic manner. Outputs measured at 1.5V with equivalent load: 14. Timing actually specified by tCKS; clock(s) specified as a reference only at minimum cycle rate. 15. Timing actually specified by tWR plus tRP; clock(s) specified as a reference only at minimum cycle rate. 16. Timing actually specified by tWR. 17. Required clocks are specified by JEDEC functionality and are not dependent on any timing parameter. 18. The IDD current will increase or decrease proportionally according to the amount of frequency alteration for the test condition. 19. Address transitions average one transition every two clocks. 20. CLK must be toggled a minimum of two times during this period. 21.Based on tCK = 7.5ns for -75 and -7E. 22. VIH overshoot: VIH (MAX) = VDDQ + 2V for a pulse width ≤ 3 ns, and the pulse width cannot be greater than one third of the cycle rate. VIL undershoot: VIL (MIN) = -2V for a pulse width ≤ 3ns. 23. The clock frequency must remain constant (stable clock is defined as a signal cycling within timing constraints specified for the clock pin) during access or precharge states (READ, WRITE, including tWR, and PRECHARGE commands). CKE may be used to reduce the data rate. 24. Auto precharge mode only. The precharge timing budget (tRP) begins 7ns for -7E and 7.5ns for -75 after the first clock delay, after the last WRITE is executed. 25. Precharge mode only. 26. JEDEC and PC100 specify three clocks. 27. tAC for -75/-7E at CL = 3 with no load is 4.6ns and is guaranteed by design. 28. Parameter guaranteed by design. 29. PC100 specifies a maximum of 4pF. 30. PC100 specifies a maximum of 5pF. 31. PC100 specifies a maximum of 6.5pF. 32. For -75, CL = 3 and tCK = 7.5ns; for -7E, CL = 2 and tCK = 7.5ns. 33. CKE is HIGH during refresh command period tRFC (MIN) else CKE is LOW. The IDD6 limit is actually a nominal value and does not result in a fail value. 34. PC133 specifies a minimum of 2.5pF. 35. PC133 specifies a minimum of 2.5pF. 36. PC133 specifies a minimum of 3.0pF. 37. For operating frequencies ≤ 45 MHz tCKS = 3.0ns. 4. 5. 6. 7. 8. 9. Q 50pF 10. tHZ defines the time at which the output achieves the open circuit condition; it is not a reference to VOH or VOL. The last valid data element will meet tOH before going High-Z. 11. AC operating and IDD test conditions have VIL = 0V and VIH = 3.0V using a measurement reference level of 1.5V. If the input transition time is longer than 1ns, then the timing is measured from VIL (MAX) and VIH (MIN) and no longer from the 1.5V midpoint. CLK should always be 1.5V referenced to crossover. Refer to Micron Technical Note TN-4809. 12. Other input signals are allowed to transition no more than once every two clocks and are otherwise at valid VIH or VIL levels. 13. IDD specifications are tested after the device is properly initialized. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 39 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 34: Initialize and Load Mode Register 2 T0 CK (( )) (( )) (( )) tCK T1 tCKS tCKH (( )) (( )) (( )) (( )) Tn + 1 tCH (( )) (( )) To + 1 tCL (( )) (( )) Tp + 1 Tp + 2 Tp + 3 CKE (( )) (( )) tCMS tCMH COMMAND (( )) (( )) NOP PRECHARGE (( )) (( )) AUTO REFRESH (( )) NOP NOP (( )) (( )) (( )) AUTO REFRESH (( )) NOP NOP (( )) (( )) (( )) LOAD MODE REGISTER NOP ACTIVE DQM/ DQML, DQMU (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) A0-A9, A11, A12 (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) tAS tAH 5 ROW CODE ALL BANKS SINGLE BANK tAS tAH ROW A10 CODE BA0, BA1 ALL BANKS (( )) (( )) BANK DQ (( )) T = 100µs MIN Power-up: VDD and CLK stable High-Z (( )) tRP tRFC tRFC tMRD Precharge all banks AUTO REFRESH AUTO REFRESH Program Mode Register 1, 3, 4 DON’T CARE UNDEFINED TIMING PARAMETERS -7E SYMBOL* tAH tAS tCH tCL tCK (3) tCK (2) tCKH MIN 0.8 1.5 2.5 2.5 7 7.5 0.8 MAX MIN 0.8 1.5 2.5 2.5 7.5 10 0.8 -75 MAX UNITS ns ns ns ns ns ns ns SYMBOL* tCKS tCMH tCMS tMRD3 tRFC tRP MIN 1.5 0.8 1.5 2 66 15 -7E MAX MIN 1.5 0.8 1.5 2 66 20 -75 MAX UNITS ns ns ns tCK ns ns *CAS latency indicated in parentheses. NOTE: 1. 2. 3. 4. 5. The mode register may be loaded prior to the AUTO REFRESH cycles if desired. If CS is HIGH at clock HIGH time, all commands applied are NOP. JEDEC and PC100 specify three clocks. Outputs are guaranteed High-Z after command is issued. A12 should be a LOW at tP + 1. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 40 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure35: Power-Down Mode 1 T0 CLK tCK T1 tCL tCKS CKE tCKS tCKH tCH T2 (( )) (( )) (( )) (( )) Tn + 1 Tn + 2 tCKS (( )) (( )) tCMS tCMH COMMAND PRECHARGE NOP NOP (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) (( )) NOP ACTIVE DQM/ DQML, DQMU A0-A9, A11, A12 ALL BANKS ROW A10 SINGLE BANK (( )) (( )) ROW tAS BA0, BA1 tAH (( )) (( )) (( )) BANK(S) (( )) (( )) (( )) BANK High-Z DQ Two clock cycles Precharge all active banks All banks idle, enter power-down mode Input buffers gated off while in power-down mode All banks idle Exit power-down mode DON’T CARE TIMING PARAMETERS -7E SYMBOL* tAH tAS tCH tCL tCK (3) MIN 0.8 1.5 2.5 2.5 7 MAX MIN 0.8 1.5 2.5 2.5 7.5 -75 MAX UNITS ns ns ns ns ns SYMBOL* tCK (2) tCKH tCKS tCMH tCMS MIN 7.5 0.8 1.5 0.8 1.5 -7E MAX MIN 10 0.8 1.5 0.8 1.5 -75 MAX UNITS ns ns ns ns ns *CAS latency indicated in parentheses. NOTE: 1. Violating refresh requirements during power-down may result in a loss of data. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 41 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 36: Clock Suspend Mode1 T0 CLK tCK T1 tCL tCH tCKS tCKH CKE tCKS tCKH T2 T3 T4 T5 T6 T7 T8 T9 tCMS tCMH COMMAND READ NOP NOP NOP NOP NOP WRITE NOP tCMS tCMH DQM/ DQML, DQMU A0-A9, A11, A12 tAS tAH 2 COLUMN e 2 COLUMN m tAS A10 tAS BA0, BA1 tAH tAH BANK BANK tAC tAC DQ tLZ DOUT m tOH tHZ DOUT m + 1 tDS tDH DIN e DIN + 1 DON’T CARE UNDEFINED TIMING PARAMETERS -7E SYMBOL* tAC (3) tAC (2) tAH tAS tCH tCL tCK (3) tCK (2) tCKH MIN MAX 5.4 5.4 MIN -75 MAX 5.4 6 UNITS ns ns ns ns ns ns ns ns ns SYMBOL* tCKS tCMH tCMS tDH tDS tHZ (3) tHZ (2) tLZ tOH MIN 1.5 0.8 1.5 0.8 1.5 -7E MAX MIN 1.5 0.8 1.5 0.8 1.5 -75 MAX UNITS ns ns ns ns ns ns ns ns ns 0.8 1.5 2.5 2.5 7 7.5 0.8 0.8 1.5 2.5 2.5 7.5 10 0.8 5.4 5.4 1 3 1 3 5.4 6 *CAS latency indicated in parentheses. NOTE: 1. For this example, the burst length = 2, the CAS latency = 3, and auto precharge is disabled. 2. x16: A9, A11 and A12 = “Don’t Care” x8: A11 and A12 = “Don’t Care” x4: A12 = “Don’t Care” PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 42 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 37: Auto Refresh Mode T0 CLK tCK T1 T2 tCH (( )) (( )) (( )) Tn + 1 tCL (( )) (( )) (( )) To + 1 CKE tCKS tCMS COMMAND tCKH tCMH NOP AUTO REFRESH NOP PRECHARGE (( )) ( ( NOP )) (( )) (( )) (( )) (( )) AUTO REFRESH NOP (( )) ( ( NOP )) (( )) (( )) (( )) (( )) (( )) (( )) ACTIVE DQM / DQML, DQMU A0-A9, A11, A12 ALL BANKS ROW A10 SINGLE BANK tAS BA0, BA1 tAH (( )) (( )) ROW BANK(S) (( )) (( )) (( )) tRP tRFC tRFC (( )) (( )) (( )) BANK DQ High-Z Precharge all active banks DON’T CARE TIMING PARAMETERS -7E SYMBOL* tAH tAS tCH tCL tCK (3) tCK (2) MIN 0.8 1.5 2.5 2.5 7 7.5 MAX MIN 0.8 1.5 2.5 2.5 7.5 10 -75 MAX UNITS ns ns ns ns ns ns SYMBOL* tCKH tCKS tCMH tCMS tRFC tRP MIN 0.8 1.5 0.8 1.5 66 15 -7E MAX MIN 0.8 1.5 0.8 1.5 66 20 -75 MAX UNITS ns ns ns ns ns ns *CAS latency indicated in parentheses. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 43 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 38: Self Refresh Mode T0 CLK tCK T1 tCH tCL T2 (( )) (( )) Tn + 1 tCKS ≥ tRAS(MIN)1 (( )) (( )) (( )) (( )) (( )) To + 1 To + 2 CKE tCKS tCMS COMMAND tCKH tCMH NOP AUTO REFRESH PRECHARGE (( )) (( )) (( )) (( )) (( )) (( )) NOP ( ( (( ) ) or COMMAND INHIBIT AUTO REFRESH )) DQM/ DQML, DQMU (( )) (( )) (( )) (( )) (( )) (( )) A0-A9, A11,A12 ALL BANKS A10 SINGLE BANK (( )) (( )) t AS BA0, BA1 tAH (( )) (( )) (( )) (( )) BANK(S) DQ High-Z tRP Precharge all active banks (( )) (( )) tXSR2 Enter self refresh mode Exit self refresh mode (Restart refresh time base) DON’T CARE CLK stable prior to exiting self refresh mode TIMING PARAMETERS -7E SYMBOL* tAH tAS tCH tCL tCK (3) tCK (2) tCKH MIN 0.8 1.5 2.5 2.5 7 7.5 0.8 MAX MIN 0.8 1.5 2.5 2.5 7.5 10 0.8 -75 MAX UNITS ns ns ns ns ns ns ns SYMBOL* tCKS tCMH tCMS tRAS tRP tXSR MIN 1.5 0.8 1.5 37 15 67 -7E MAX MIN 1.5 0.8 1.5 44 20 75 -75 MAX UNITS ns ns ns ns ns ns 120,000 120,000 *CAS latency indicated in parentheses. NOTES: 1. No maximum time limit for Self Refresh. tRAS(MAX) applies to non-Self Refresh mode. 2. tXSR requires minimum of two clocks regardless of frequency or timing. 3. As a general rule, any time Self Refresh is exited, the DRAM may not reenter the Self Refresh mode until all rows have been refreshed by the Auto Refresh command at the distributed refresh rate, tREF, or faster. However, the following exceptions are allowed a. The DRAM has been in Self Refresh mode for a minimum of 64mS prior to exiting. b. TXSR is not violated c.. At least two Auto Refresh commands are preformed during each 7.81mS interval while the DRAM remains out of the Self Refresh mode. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 44 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 39: Read – Without Auto Precharge1 T0 CLK tCKS CKE tCMS COMMAND tCMH NOP READ NOP NOP NOP PRECHARGE NOP ACTIVE T1 tCK tCKH tCL T2 tCH T3 T4 T5 T6 T7 T8 ACTIVE tCMS DQM/ DQML, DQMU tAS A0-A9, A11, A12 tAS A10 tAS BA0, BA1 tAH ROW tCMH COLUMN m 2 ROW tAH ROW ALL BANKS ROW DISABLE AUTO PRECHARGE BANK SINGLE BANK BANK BANK tAH BANK tAC DQ tRCD tRAS tRC tLZ CAS Latency tAC tOH DOUT m tAC tOH DOUT m + 1 tAC tOH DOUT m + 2 tOH DOUT m + 3 tHZ tRP DON’T CARE UNDEFINED TIMING PARAMETERS -7E SYMBOL* tAC (3) tAC (2) tAH tAS tCH tCL tCK (3) tCK (2) tCKH tCKS MIN MAX 5.4 5.4 MIN -75 MAX 5.4 6 UNITS ns ns ns ns ns ns ns ns ns ns SYMBOL* tCMH tCMS tHZ (3) tHZ (2) tLZ tOH tRAS tRC tRCD tRP MIN 0.8 1.5 -7E MAX MIN 0.8 1.5 -75 MAX UNITS ns ns ns ns ns ns ns ns ns ns 0.8 1.5 2.5 2.5 7 7.5 0.8 1.5 0.8 1.5 2.5 2.5 7.5 10 0.8 1.5 5.4 5.4 1 3 37 60 20 15 1 3 44 66 20 20 5.4 6 120,000 120,000 *CAS latency indicated in parentheses. NOTE: 1. For this example, the burst length = 4, the CAS latency = 2, and the READ burst is followed by a “manual” PRECHARGE. 2. x16: A9, A11, and A12 = “Don’t Care” x8: A11 and A12 = “Don’t Care” x4: A12 = “Don’t Care” PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 45 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 40: Read – With Auto Precharge1 T0 CLK tCKS CKE tCMS tCMH COMMAND ACTIVE NOP READ NOP NOP NOP NOP NOP ACTIVE T1 tCK tCKH tCL T2 tCH T3 T4 T5 T6 T7 T8 tCMS DQM/ DQML, DQMU tAS A0-A9, A11, A12 tAH tCMH ROW COLUMN m 2 ROW tAS A10 tAH ENABLE AUTO PRECHARGE ROW ROW tAS BA0, BA1 tAH BANK BANK BANK tAC DQ tRCD tRAS tRC tLZ CAS Latency tAC tOH DOUT m tAC tOH DOUT m + 1 tAC tOH DOUT m + 2 tOH DOUT m + 3 tHZ tRP DON’T CARE UNDEFINED TIMING PARAMETERS -7E SYMBOL* tAC (3) tAC (2) tAH tAS tCH tCL tCK (3) tCK (2) tCKH tCKS MIN MAX 5.4 5.4 MIN -75 MAX 5.4 6 UNITS ns ns ns ns ns ns ns ns ns ns SYMBOL* tCMH tCMS tHZ (3) tHZ (2) tLZ tOH tRAS tRC tRCD tRP MIN 0.8 1.5 -7E MAX MIN 0.8 1.5 -75 MAX UNITS ns ns ns ns ns ns ns ns ns ns 0.8 1.5 2.5 2.5 7 7.5 0.8 1.5 0.8 1.5 2.5 2.5 7.5 10 0.8 1.5 5.4 5.4 1 3 37 60 15 15 1 3 44 66 20 20 5.4 6 120,000 120,000 *CAS latency indicated in parentheses. NOTE: 1. For this example, the burst length = 4, and the CAS latency = 2. 2. x16: A9, A11, and A12 = “Don’t Care” x8: A11 and A12 = “Don’t Care” x4: A12 = “Don’t Care” PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 46 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 41: Single Read – Without Autor Precharge1 T0 CLK tCKS CKE tCMS tCMH COMMAND ACTIVE NOP READ tCMS tCMH DQM / DQML, DQMU tAS A0-A9, A11,A12 tAS A10 tAS BA0, BA1 tAH ROW tAH ROW tAH BANK DISABLE AUTO PRECHARGE BANK SINGLE BANKS BANK(S) BANK COLUMN m3 T1 tCK tCKH tCL T2 tCH T3 T4 T5 T6 T7 T8 NOP 2 NOP 2 PRECHARGE NOP ACTIVE NOP ROW ALL BANKS ROW tAC DQ tRCD tRAS tRC tLZ CAS Latency tOH DOUT m tHZ tRP DON’T CARE UNDEFINED TIMING PARAMETERS -7E SYMBOL* tAC (3) tAC (2) tAH tAS tCH tCL tCK (3) tCK (2) tCKH tCKS MIN MAX 5.4 5.4 MIN -75 MAX 5.4 6 UNITS ns ns ns ns ns ns ns ns ns ns SYMBOL* tCMH tCMS tHZ (3) tHZ (2) tLZ tOH tRAS tRC tRCD tRP MIN 0.8 1.5 -7E MAX MIN 0.8 1.5 -75 MAX UNITS ns ns ns ns ns ns ns ns ns ns 0.8 1.5 2.5 2.5 7 7.5 0.8 1.5 0.8 1.5 2.5 2.5 7.5 10 0.8 1.5 5.4 5.4 1 3 37 60 15 15 1 3 44 66 20 20 5.4 6 120,000 120,000 *CAS latency indicated in parentheses. NOTE: 1. For this example, the burst length = 1, the CAS latency = 2, and the READ burst is followed by a “manual” PRECHARGE. 2. PRECHARGE command not allowed else tRAS would be violated. 3. x16: A9, A11, and A12 = “Don’t Care” x8: A11 and A12 = “Don’t Care” x4: A12 = “Don’t Care” PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 47 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 42: Single Read – With Auto Precharge1 T0 CLK tCKS CKE tCMS tCMH COMMAND ACTIVE NOP NOP2 NOP2 READ NOP NOP ACTIVE NOP T1 tCK tCKH tCL T2 tCH T3 T4 T5 T6 T7 T8 tCMS DQM / DQML, DQMU tAS A0-A9, A11 tAH tCMH ROW COLUMN m3 ROW tAS A10 tAH ENABLE AUTO PRECHARGE ROW ROW tAS BA0, BA1 tAH BANK BANK BANK tAC t OH DQ tRCD tRAS tRC CAS Latency tRP DOUT m tHZ DON’T CARE UNDEFINED TIMING PARAMETERS -7E SYMBOL* tAC (3) tAC (2) tAH tAS tCH tCL tCK (3) tCK (2) tCKH tCKS MIN MAX 5.4 5.4 MIN -75 MAX 5.4 6 UNITS ns ns ns ns ns ns ns ns ns ns SYMBOL* tCMH tCMS tHZ (3) tHZ (2) tLZ tOH tRAS tRC tRCD tRP MIN 0.8 1.5 -7E MAX MIN 0.8 1.5 -75 MAX UNITS ns ns ns ns ns ns ns ns ns ns 0.8 1.5 2.5 2.5 7 7.5 0.8 1.5 0.8 1.5 2.5 2.5 7.5 10 0.8 1.5 5.4 5.4 1 3 37 60 15 15 1 3 44 66 20 20 5.4 6 120,000 120,000 *CAS latency indicated in parentheses. NOTE: 1. For this example, the burst length = 1, and the CAS latency = 2. 2. PRECHARGE command not allowed else tRAS would be violated. 3. x16: A9, A11, and A12 = “Don’t Care” x8: A11 and A12 = “Don’t Care” x4: A12 = “Don’t Care” PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 48 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 43: Alternating Bank Read Accesses1 T0 CLK tCKS CKE tCMS COMMAND tCMH NOP READ NOP ACTIVE NOP READ NOP ACTIVE T1 tCK tCKH tCL T2 tCH T3 T4 T5 T6 T7 T8 ACTIVE tCMS DQM/ DQML, DQMU tAS A0-A9, A11, A12 tAH tCMH ROW COLUMN m 2 ROW COLUMN b 2 ROW tAS A10 tAH ENABLE AUTO PRECHARGE ROW ENABLE AUTO PRECHARGE ROW ROW tAS BA0, BA1 tAH BANK 0 BANK 3 BANK 3 BANK 0 BANK 0 tAC DQ tRCD - BANK 0 tRAS - BANK 0 tRC - BANK 0 tRRD tLZ CAS Latency - BANK 0 tAC tOH DOUT m tAC tOH DOUT m + 1 tAC tOH DOUT m + 2 tAC tOH DOUT m + 3 tAC tOH DOUT b tRP - BANK 0 tRCD - BANK 0 tRCD - BANK 3 CAS Latency - BANK 3 DON’T CARE UNDEFINED TIMING PARAMETERS -7E SYMBOL* tAC (3) tAC (2) tAH tAS tCH tCL tCK (3) tCK (2) tCKH tCKS MIN MAX 5.4 5.4 MIN -75 MAX 5.4 6 UNITS ns ns ns ns ns ns ns ns ns ns SYMBOL* tCMH tCMS tLZ tOH tRAS tRC tRCD tRP tRRD MIN 0.8 1.5 1 3 37 60 15 15 14 -7E MAX MIN 0.8 1.5 1 3 44 66 20 20 15 -75 MAX UNITS ns ns ns ns ns ns ns ns ns 0.8 1.5 2.5 2.5 7 7.5 0.8 1.5 0.8 1.5 2.5 2.5 7.5 10 0.8 1.5 120,000 120,000 *CAS latency indicated in parentheses. NOTE: 1. For this example, the burst length = 4, and the CAS latency = 2. 2. x16: A9, A11, and A12 = “Don’t Care” x8: A11 and A12 = “Don’t Care” x4: A12 = “Don’t Care” PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 49 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 44: Read – Full-Page Burst1 T0 CLK tCKS CKE tCMS COMMAND tCMH NOP READ NOP NOP NOP NOP T1 tCL tCH tCKH tCK T2 T3 T4 T5 T6 (( )) (( )) Tn + 1 Tn + 2 Tn + 3 Tn + 4 (( )) (( )) (( )) (( )) (( )) (( )) ACTIVE NOP BURST TERM NOP NOP tCMS DQM/ DQML, DQMU tAS A0-A9, A11, A12 tAH tCMH ROW COLUMN m 2 (( )) (( )) tAS A10 tAH ROW (( )) (( )) tAS BA0, BA1 tAH BANK BANK (( )) (( )) tAC tAC DQ tLZ tRCD CAS Latency tOH DOUT m tAC tOH DOUT m+1 DOUT tAC ( ( tOH ) ) (( )) m+2 (( )) tAC tOH DOUT m-1 tAC tOH Dout m tOH DOUT m+1 512 (x16) locations within same row 1,024 (x8) locations within same row 2,048 (x4) locations within same row tHZ Full page completed Full-page burst does not self-terminate. 3 Can use BURST TERMINATE command. DON’T CARE UNDEFINED TIMING PARAMETERS -7E SYMBOL* tAC (3) tAC (2) tAH tAS tCH tCL tCK (3) tCK (2) tCKH MIN MAX 5.4 5.4 MIN -75 MAX 5.4 6 UNITS ns ns ns ns ns ns ns ns ns SYMBOL* tCKS tCMH tCMS tHZ (3) tHZ (2) tLZ tOH tRCD MIN 1.5 0.8 1.5 -7E MAX MIN 1.5 0.8 1.5 -75 MAX UNITS ns ns ns ns ns ns ns ns 0.8 1.5 2.5 2.5 7 7.5 0.8 0.8 1.5 2.5 2.5 7.5 10 0.8 5.4 5.4 1 3 15 1 3 20 5.4 6 *CAS latency indicated in parentheses. NOTE: 1. For this example, the CAS latency = 2. 2. x16: A9, A11, and A12 = “Don’t Care” x8: A11 and A12 = “Don’t Care” x4: A12 = “Don’t Care” 3. Page left open; no tRP. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 50 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 45: Read – DQM Operation1 T0 CLK tCKS CKE tCMS COMMAND tCMH NOP READ NOP NOP NOP NOP NOP NOP T1 tCK tCKH tCL T2 tCH T3 T4 T5 T6 T7 T8 ACTIVE tCMS DQM/ DQML, DQMU tAS A0-A9, A11, A12 tAH tCMH ROW COLUMN m 2 ENABLE AUTO PRECHARGE tAS A10 tAH ROW tAS BA0, BA1 tAH BANK DISABLE AUTO PRECHARGE BANK tAC DQ tLZ tRCD CAS Latency tOH DOUT m tAC tAC tOH DOUT m + 2 tOH DOUT m + 3 tHZ tLZ tHZ DON’T CARE UNDEFINED TIMING PARAMETERS -7E SYMBOL* tAC (3) tAC (2) tAH tAS tCH tCL tCK (3) tCK (2) tCKH MIN MAX 5.4 5.4 MIN -75 MAX 5.4 6 UNITS ns ns ns ns ns ns ns ns ns SYMBOL* tCKS tCMH tCMS tHZ (3) tHZ (2) tLZ tOH tRCD MIN 1.5 0.8 1.5 -7E MAX MIN 1.5 0.8 1.5 -75 MAX UNITS ns ns ns ns ns ns ns ns 0.8 1.5 2.5 2.5 7 7.5 0.8 0.8 1.5 2.5 2.5 7.5 10 0.8 5.4 5.4 1 3 15 1 3 20 5.4 6 *CAS latency indicated in parentheses. NOTE: 1. For this example, the burst length = 4, and the CAS latency = 2. 2. x16: A9, A11, and A12 = “Don’t Care” x8: A11 and A12 = “Don’t Care” x4: A12 = “Don’t Care” PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 51 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 46: Write – Without Auto Precharge1 T0 CLK tCKS CKE tCMS COMMAND tCMH NOP WRITE NOP NOP NOP NOP PRECHARGE NOP ACTIVE tCK tCKH T1 tCL T2 tCH T3 T4 T5 T6 T7 T8 T9 ACTIVE tCMS tCMH DQM/ DQML, DQMU tAS A0-A9, A11, A12 tAH COLUMN m 2 ALL BANKs ROW DISABLE AUTO PRECHARGE BANK SINGLE BANK BANK BANK ROW ROW tAS A10 tAH ROW tAS BA0, BA1 tAH BANK tDS DQ tRCD tRAS tRC tDH DIN m tDS tDH tDS tDH tDS tDH DIN m + 1 DIN m + 2 DIN m + 3 t WR 3 tRP DON’T CARE TIMING PARAMETERS -7E SYMBOL* tAH tAS tCH tCL tCK (3) tCK (2) tCKH tCKS tCMH MIN 0.8 1.5 2.5 2.5 7 7.5 0.8 1.5 0.8 MAX MIN 0.8 1.5 2.5 2.5 7.5 10 0.8 1.5 0.8 -75 MAX UNITS ns ns ns ns ns ns ns ns ns SYMBOL* tCMS tDH tDS tRAS tRC tRCD tRP tWR MIN 1.5 0.8 1.5 37 60 15 15 14 -7E MAX MIN 1.5 0.8 1.5 44 66 20 20 15 -75 MAX UNITS ns ns ns ns ns ns ns ns 120,000 120,000 *CAS latency indicated in parentheses. NOTE: 1. For this example, the burst length = 4, and the WRITE burst is followed by a “manual” PRECHARGE. 2. 14ns to 15ns is required between and the PRECHARGE command, regardless of frequency. 3. x16: A9, A11, and A12 = “Don’t Care” x8: A11 and A12 = “Don’t Care” x4: A12 = “Don’t Care” PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 52 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 47: Write – With Auto Precharge1 T0 CLK tCKS CKE tCMS COMMAND tCMH NOP WRITE NOP NOP NOP NOP NOP NOP ACTIVE tCK tCKH T1 tCL T2 tCH T3 T4 T5 T6 T7 T8 T9 ACTIVE tCMS tCMH DQM/ DQML, DQMU tAS A0-A9, A11, A12 tAH COLUMN m 2 ENABLE AUTO PRECHARGE ROW ROW ROW tAS A10 tAH ROW tAS BA0, BA1 tAH BANK BANK BANK tDS DQ tRCD tRAS tRC tDH DIN m tDS tDH tDS tDH tDS tDH DIN m + 1 DIN m + 2 DIN m + 3 tWR tRP DON’T CARE TIMING PARAMETERS -7E SYMBOL* tAH tAS tCH tCL tCK (3) tCK (2) tCKH tCKS tCMH MIN 0.8 1.5 2.5 2.5 7 7.5 0.8 1.5 0.8 MAX MIN 0.8 1.5 2.5 2.5 7.5 10 0.8 1.5 0.8 -75 MAX UNITS ns ns ns ns ns ns ns ns ns SYMBOL* tCMS tDH tDS tRAS tRC tRCD tRP tWR MIN 1.5 0.8 1.5 37 60 15 15 1 CLK + 7ns -7E MAX MIN 1.5 0.8 1.5 44 66 20 20 1 CLK + 7.5ns -75 MAX UNITS ns ns ns ns ns ns ns – 120,000 120,000 *CAS latency indicated in parentheses. NOTE: 1. For this example, the burst length = 4. 2. x16: A9, A11, and A12 = “Don’t Care” x8: A11 and A12 = “Don’t Care” x4: A12 = “Don’t Care” PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 53 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 48: Single Write – Without Auto Precharge1 T0 CLK tCKS CKE tCMS COMMAND tCMH NOP WRITE NOP 2 NOP 2 PRECHARGE NOP ACTIVE NOP tCK tCKH T1 tCL T2 tCH T3 T4 T5 T6 T7 T8 ACTIVE tCMS tCMH DQM / DQML, DQMU tAS A0-A9, A11 tAH COLUMN m 3 ALL BANKS ROW DISABLE AUTO PRECHARGE BANK SINGLE BANK BANK BANK ROW tAS A10 tAH ROW tAS BA0, BA1 tAH BANK tDS DQ tRCD tRAS tRC tDH DIN m t WR 4 tRP DON’T CARE TIMING PARAMETERS -7E SYMBOL* tAH tAS tCH tCL tCK (3) tCK (2) tCKH tCKS tCMH MIN 0.8 1.5 2.5 2.5 7 7.5 0.8 1.5 0.8 MAX MIN 0.8 1.5 2.5 2.5 7.5 10 0.8 1.5 0.8 -75 MAX UNITS ns ns ns ns ns ns ns ns ns SYMBOL* tCMS tDH tDS tRAS tRC tRCD tRP tWR MIN 1.5 0.8 1.5 37 60 15 15 14 -7E MAX MIN 1.5 0.8 1.5 44 66 20 20 15 -75 MAX UNITS ns ns ns ns ns ns ns ns 120,000 120,000 *CAS latency indicated in parentheses. NOTE: 1. For this example, the burst length = 1, and the WRITE burst is followed by a “manual” PRECHARGE. 2. 14ns to 15ns is required between and the PRECHARGE command, regardless of frequency. With a single write tWR has been increased to meet minimum tRAS requirement. 3. x16: A8, A9, and A11 = “Don’t Care” x8: A9 and A11 = “Don’t Care” x4: A11 = “Don’t Care” 4. PRECHARGE command not allowed else tRAS would be violated. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 54 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 49: Single Write – With Auto Precharge1 T0 CK tCKS CKE tCMS COMMAND tCMH NOP2 NOP2 NOP2 WRITE NOP NOP NOP ACTIVE NOP tCK tCKH T1 tCL T2 tCH T3 T4 T5 T6 T7 T8 T9 ACTIVE tCMS DQM/ DQML, DQMU tAS A0-A9, A11, A12 tAH tCMH ROW COLUMN m 3 ENABLE AUTO PRECHARGE ROW tAS A10 tAH ROW ROW tAS BA0, BA1 tAH BANK BANK BANK tDS DQ tRCD tRAS tRC tDH DIN m tWR4 tRP DON’T CARE TIMING PARAMETERS -7E SYMBOL* tAH tAS tCH tCL tCK (3) tCK (2) tCKH tCKS tCMH MIN 0.8 1.5 2.5 2.5 7 7.5 0.8 1.5 0.8 MAX MIN 0.8 1.5 2.5 2.5 7.5 10 0.8 1.5 0.8 -75 MAX UNITS ns ns ns ns ns ns ns ns ns SYMBOL* tCMS tDH tDS tRAS tRC tRCD tRP tWR MIN 1.5 0.8 1.5 37 60 15 15 1 CLK + 7ns -7E MAX MIN 1.5 0.8 1.5 44 66 20 20 1 CLK + 7.5ns -75 MAX UNITS ns ns ns ns ns ns ns – 120,000 120,000 *CAS latency indicated in parentheses. NOTE: 1. For this example, the burst length = 1. 2. Requires one clock plus time (7ns to 7.5ns) with auto precharge or 14ns to 15ns with PRECHARGE. 3. x16: A9, A11, and A12 = “Don’t Care” x8: A11 and A12 = “Don’t Care” x4: A12 = “Don’t Care” 4. WRITE command not allowed else tRAS would be violated. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 55 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 50: Alternating Bank Write Accesses1 T0 CLK tCKS CKE tCMS COMMAND tCMH NOP WRITE NOP ACTIVE NOP WRITE NOP NOP ACTIVE tCK tCKH T1 tCL T2 tCH T3 T4 T5 T6 T7 T8 T9 ACTIVE tCMS DQM/ DQML, DQMU tAS A0-A9, A11, A12 tAH tCMH ROW COLUMN m 3 ROW COLUMN b 3 ROW tAS A10 tAH ENABLE AUTO PRECHARGE ROW ENABLE AUTO PRECHARGE ROW ROW tAS BA0, BA1 tAH BANK 0 BANK 1 BANK 1 BANK 0 BANK 0 tDS DQ tRCD - BANK 0 tRAS - BANK 0 tRC - BANK 0 tRRD tDH DIN m tDS tDH tDS tDH tDS tDH tDS tDH DIN b tDS tDH tDS tDH tDS tDH DIN m + 1 DIN m + 2 DIN m + 3 DIN b + 1 DIN b + 2 tRP - BANK 0 DIN b + 3 tRCD - BANK 0 tWR - BANK 0 tRCD - BANK 1 tWR - BANK 1 DON’T CARE TIMING PARAMETERS -7E SYMBOL* tAH tAS tCH tCL tCK (3) tCK (2) tCKH tCKS tCMH MIN 0.8 1.5 2.5 2.5 7 7.5 0.8 1.5 0.8 MAX MIN 0.8 1.5 2.5 2.5 7.5 10 0.8 1.5 0.8 -75 MAX UNITS ns ns ns ns ns ns ns ns ns SYMBOL* tCMS tDH tDS tRAS tRC tRCD tRP tRRD tWR MIN 1.5 0.8 1.5 37 60 15 15 14 Note 2 -7E MAX MIN 1.5 0.8 1.5 44 66 20 20 15 Note 2 -75 MAX UNITS ns ns ns ns ns ns ns ns ns 120,000 120,000 *CAS latency indicated in parentheses. NOTE: 1. For this example, the burst length = 4. 2. Requires one clock plus time (7ns or 7.5ns) with auto precharge or 14ns to 15ns with PRECHARGE. 3. x16: A9, A11, and A12 = “Don’t Care” x8: A11 and A12 = “Don’t Care” x4: A12 = “Don’t Care” PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 56 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 51: Write – Full-Page Burst T0 CLK tCKS CKE tCMS COMMAND tCMH NOP WRITE NOP NOP NOP T1 tCL tCH tCKH tCK T2 T3 T4 T5 (( )) (( )) Tn + 1 Tn + 2 Tn + 3 (( )) (( )) (( )) (( )) ACTIVE NOP BURST TERM NOP tCMS tCMH DQM/ DQML, DQMU tAS A0-A9, A11, A12 tAH COLUMN m 1 (( )) (( )) ROW (( )) (( )) tAS A10 tAH ROW (( )) (( )) tAS BA0, BA1 tAH BANK BANK (( )) (( )) tDS DQ tRCD tDH DIN m tDS tDH tDS tDH tDS tDH DIN m + 1 DIN m + 2 DIN m + 3 (( )) (( )) tDS tDH DIN m - 1 Full-page burst does not self-terminate. Can use BURST TERMINATE command to stop.2, 3 512 (x16) locations within same row 1,024 (x8) locations within same row 2,048 (x4) locations within same row Full page completed DON’T CARE TIMING PARAMETERS -7E SYMBOL* tAH tAS tCH tCL tCK (3) tCK (2) tCKH -75 MAX MIN 0.8 1.5 2.5 2.5 7.5 10 0.8 MAX UNITS ns ns ns ns ns ns ns SYMBOL* tCKS tCMH tCMS tDH tDS tRCD -7E MIN 1.5 0.8 1.5 0.8 1.5 15 MAX MIN 1.5 0.8 1.5 0.8 1.5 20 -75 MAX UNITS ns ns ns ns ns ns MIN 0.8 1.5 2.5 2.5 7 7.5 0.8 *CAS latency indicated in parentheses. NOTE: 1. x16: A9, A11, and A12 = “Don’t Care” x8: A11 and A12 = “Don’t Care” x4: A12 = “Don’t Care” 2. tWR must be satisfied prior to PRECHARGE command. 3. Page left open; no tRP. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 57 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 52: Write – DQM Operation1 T0 CLK tCKS CKE tCMS COMMAND tCMH NOP WRITE NOP NOP NOP NOP NOP T1 tCK tCKH tCL T2 tCH T3 T4 T5 T6 T7 ACTIVE tCMS tCMH DQM/ DQML, DQMU tAS A0-A9, A11, A12 tAH COLUMN m 2 ENABLE AUTO PRECHARGE ROW tAS A10 tAH ROW tAS BA0, BA1 tAH DISABLE AUTO PRECHARGE BANK BANK tDS DQ tRCD tDH DIN m tDS tDH tDS tDH DIN m + 2 DIN m + 3 DON’T CARE TIMING PARAMETERS -7E SYMBOL* tAH tAS tCH tCL tCK (3) tCK (2) tCKH MIN 0.8 1.5 2.5 2.5 7 7.5 0.8 MAX MIN 0.8 1.5 2.5 2.5 7.5 10 0.8 -75 MAX UNITS ns ns ns ns ns ns ns SYMBOL* tCKS tCMH tCMS tDH tDS tRCD MIN 1.5 0.8 1.5 0.8 1.5 15 -7E MAX MIN 1.5 0.8 1.5 0.8 1.5 20 -75 MAX UNITS ns ns ns ns ns ns *CAS latency indicated in parentheses. NOTE: 1. For this example, the burst length = 4. 2. x16: A9, A11, and A12 = “Don’t Care” x8: A11 and A12 = “Don’t Care” x4: A12 = “Don’t Care” PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 58 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 53: 54-PIN PLASTIC TSOP (400 mil) 22.22 ±.08 .71 .80 TYP .375 ±.075 TYP 2X 0.10 SEE DETAIL A 2.80 11.76 ±0.20 10.16 ±0.08 R 2X 0.75 PIN #1 ID R 2X 1.00 0.15 +0.03 -0.02 GAGE PLANE 0.25 0.10 0.10 PLATED LEAD FINISH: 90% Sn, 10% Pb OR 100%Sn PLASTIC PACKAGE MATERIAL: EPOXY NOVOLAC PACKAGE WIDTH AND LENGTH DO NOT INCLUDE MOLD PROTRUSION. ALLOWABLE PROTRUSION IS 0.25 PER SIDE. +0.10 -0.05 0.50 ±0.10 0.80 TYP DETAIL A 1.2 MAX NOTE: 1. All dimensions in millimeters . 2. Package width and length do not include mold protrusion; allowable mold protrusion is 0.25mm per side. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 59 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 54: FBGA “FB” Package, 60-Ball, 8mm x 16mm x4, x8 .205 MAX .850 ±.075 .10 A SEATING PLANE A 8.00 ±.10 5.60 .80 TYP PIN #1 ID SOLDER BALL MATERIAL: 62% Sn, 36% Pb, 2% Ag SOLDER BALL PAD: Ø 0.33mm SUBSTRATE: PLASTIC LAMINATE ENCAPSULATION MATERIAL: EPOXY NOVOLAC PIN #1 ID BALL A1 60X Ø .45 BALL A8 8.00 ±.05 16.00 ±.10 .80 TYP 11.20 5.60 ±.05 2.40 ±.05 CTR 2.80 ±.05 1.20 MAX 4.00 ±.05 (Bottom View) NOTE: 1. All dimensions in millimeters. 2. Recommended Pad size for PCB is 0.33mm±0.025mm. 3. Top side part marking decode can be found at: http://www.micron.com/products/fbga/FBGA.asp PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 60 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved. 256Mb: x4, x8, x16 SDRAM Figure 55: VFBGA “FG” Package, 54-ball, 8mm x 14mm x16 0.65 ±0.05 SEATING PLANE C 0.10 C 6.40 54X Ø0.45 SOLDER BALL DIAMETER REFERS TO POST REFLOW CONDITION. THE PREREFLOW DIAMETER IS Ø0.42 BALL A9 0.80 TYP 1.00 MAX BALL A1 ID BALL A1 ID BALL A1 0.80 TYP C L 3.20 ±0.05 7.00 ±0.05 6.40 14.00 ±0.10 3.20 ±0.05 C L 4.00 ±0.05 MOLD COMPOUND: EPOXY NOVOLAC SUBSTRATE MATERIAL: PLASTIC LAMINATE SOLDER BALL MATERIAL: 62% Sn, 36% Pb, 2% Ag OR 96.5% Sn, 3%Ag, 0.5% Cu SOLDER MASK DEFINED BALL PADS: Ø 0.40 8.00 ±0.10 (Bottom View) NOTE: 1. All dimensions in millimeters. 2. Recommended Pad size for PCB is 0.4mm±0.065mm. 3. Top side part marking decode can be found at: http://www.micron.com/products/fbga/FBGA.asp DATA SHEET DESIGNATION Production: This data sheet contains minimum and maximum limits specified over the complete power supply and temperature range for production devices. Although considered final, these specifications are subject to change, as further product development and data characterization sometimes occur. 8000 S. Federal Way, P.O. Box 6, Boise, ID 83707-0006, Tel: 208-368-3900 E-mail: prodmktg@micron.com, Internet: http://www.micron.com, Customer Comment Line: 800-932-4992 Micron, the M logo, and the Micron logo are trademarks of Micron Technology, Inc. PDF: 09005aef8091e6d1/Source: 09005aef8091e6a8 256MSDRAM.pmd – Rev. H; Pub. 2/05 61 Micron Technology, Inc., reserves the right to change products or specifications without notice. ©2003 Micron Technology, Inc. All rights reserved.
MT48LC32M8A2 价格&库存

很抱歉,暂时无法提供与“MT48LC32M8A2”相匹配的价格&库存,您可以联系我们找货

免费人工找货