0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
FCPM-6000RC

FCPM-6000RC

  • 厂商:

    MINI

  • 封装:

    -

  • 描述:

    FCPM-6000RC

  • 数据手册
  • 价格&库存
FCPM-6000RC 数据手册
USB / Ethernet FCPM-6000RC Integrated Frequency Counter & Power Meter 50Ω -30 dBm to +20 dBm, 1 MHz to 6000 MHz The Big Deal • Automatically synchronized power & frequency measurements • USB and Ethernet control • Includes GUI with measurement applications software, simplifying complex measurements • Measurement speed 30ms Applications • • • • CASE STYLE: JL2029 Included Accessories Description Model No. Production testing systems Field testing & remote location monitoring automatic, scheduled data collection Evaluate high-power, multi-port devices with built-in virtual couplers/attenuators & other software tools. Software Package USB-RJ45-CBL-7+ 2.6 ft. USB cable Qty. 1 RoHS Compliant See our web site for RoHS Compliance methodologies and qualifications Product Overview Mini-Circuits’ FCPM-6000RC Integrated Frequency Counter & Power Meter is a compact (5.00 x 2.66 x 1.36”) precision test device controlled via USB or Ethernet (HTTP and Telnet protocols) or operated as standalone test instrument. It simplifies test setups by enabling synchronized frequency and power measurements from a single device. The unit features an LCD display allowing convenient readings directly off the measurement head, while our user-friendly GUI software enables easy remote test management via USB or Ethernet. Full software support is provided, including our user-friendly GUI application for Windows and a full API and programming instructions for both Windows and Linux environments (32-bit and 64-bit systems). The latest version of the full software package can be downloaded from https://www.minicircuits.com/softwaredownload/fcpm.html at any time. Key Features Feature Advantages USB & Ethernet control USB HID and Ethernet (HTTP / Telnet) interfaces provide easy compatibility with a wide range of software setups and programming environments ‘Measurement Application’ GUI software built-in Automated measurement setups which allow the user to perform measurements on RF components such as Couplers, Filters, Amplifiers, etc., display numerical data and graphs, and analyze the data. LCD character display LCD character display providing the frequency and power readings, as well as information on the unit’s status. Operates with external or internal reference The FCPM-6000RC can operate either synchronized with an external 10 MHz reference signal or independently, using its internal reference depending on user preference. No calibration required before taking measurement The FCPM-6000RC does not require any reference signal for calibration, reducing test time and simplifying operation. 5V power supply Powered via USB plug from PC, AC adapter or from commercially available Power Over Ethernet (PoE) splitter with 5V output. Trademarks: Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Linux is a registered trademark of Linus Torvalds. Mac is a registered trademark of Apple Corporation. Pentium is a registered trademark of Intel Corporation. Neither Mini-Circuits nor the Mini-Circuits FCPM6000RC are affiliated with or endorsed by the owners of the above referenced trademarks Rev. D Mini-Circuits and the Mini-Circuits logo are registered trademarks of Scientific Components Corporation. Mini-Circuits ® www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com M169105 EDR-11250 FCPM-6000RC RAV 180902 Page 1 of 8 Integrated Frequency Counter & Power Meter FCPM-6000RC Electrical Specifications (CW) 1, -30 dBm to +20 dBm, 1 to 6000 MHz Parameter Dynamic range 2,3,4 @ 25ºC @ 0ºC to 50ºC VSWR @ -30 to +5 dBm 5,6 Uncertainty of Power Measurement @ 25ºC @ +5 to +15 dBm @ +15 to +20 dBm @ -30 to +5 dBm 5,6 Uncertainty of Power Measurement @ 0ºC to 50ºC @ +5 to +15 dBm @ +15 to +20 dBm Freq. Range (MHz) Min. Typ. Max. Units 1 - 5700 -30 − +20 5700 - 6000 -28 − +20 1 - 6000 -27 − +20 1 - 6000 − 1.05 1.25 :1 1 - 3000 − ± 0.10 ± 0.30 dB 3000 - 6000 − ± 0.15 ± 0.30 dB 1 - 3000 − ± 0.15 ± 0.30 dB 3000 - 6000 − ± 0.15 ± 0.30 dB 1 - 3000 − ± 0.20 ± 0.40 dB 3000 - 6000 − ± 0.20 ± 0.40 dB 1 - 3000 − ± 0.25 − dB 3000 - 6000 − ± 0.25 − dB 1 - 3000 − ± 0.20 − dB 3000 - 6000 − ± 0.20 − dB 1 - 3000 − ± 0.35 − dB dB dBm 3000 - 6000 − ± 0.30 − Power Linearity @ 25ºC 1 - 6000 − ± 3.0 − % Power Resolution 1 - 6000 0.01 − − dB 1 - 40 MHz − 1 − Frequency Resolution Frequency Uncertainty (@1 sec measurement sample time) 4,7 Averaging Range Frequency Aging Using int. Reference Measurement Speed (for power meas.) @ Low Noise Mode @ Faster Mode 40-190 MHz − 10 − 190-6000 MHz − 100 − Hz 1 - 40 MHz − ±2 − 40-190 MHz − ±20 − 190-1400 MHz − ±200 − 1400 - 6000 MHz − ±800 − 1 - 6000 1 − 999 − − − − ±1.0 ppm/year − 100 − − 30 − 1 - 6000 Hz msec Sample time (for frequency meas.) 8 − 100 1000 3000 msec Input Impedance − − 50 − Ω Reference In Frequency − − 10 − MHz Reference In Impedance − − 50 − Ω Reference In Power − -5 − +10 dBm 1 - 6000 4.5 5 5.5 V Current (via USB port, in USB control) 1 - 6000 − 370 500 mA Current (via USB port, in Ethernet control) 1 - 6000 − 380 500 mA Supply Voltage via USB port Ethernet communication Supports both Telnet and HTTP protocols over TCP/IP with dynamic(DHCP) or static IP 1 All specifications apply to continuous wave (CW) signals. continuous safe operational power limit: +23 dBm. Performance is guaranteed up to +20 dBm. 3 The FCPM-6000RC can operate down to -32 dBm, however performance is guaranteed only in the range specified in the table. 4 Minimum power for Frequency measurement at 190-240 MHz may degrade by up to 3 dB due to measurement band switching. 5 When using Faster mode at high frequencies below -20dBm, use of averaging is recommended to prevent noise errors. 6 When using Faster mode power reading below -20dBm, uncertainty value may increase by up to 0.2 dB relative to Low noise mode power reading. 7 Accuracy shown using external 10 MHz reference synchronized to test signal. Using Internal Reference adds 2 ppm of tested frequency to the accuracy values shown. 8 Software function set by user, default option 1000 mec. 2 Maximum Mini-Circuits ® www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com Page 2 of 8 Integrated Frequency Counter & Power Meter Absolute Maximum Ratings Parameter Connections Reference Input Ratings Operating Temperature Storage Temperature 6V 15 V DC Voltage @ Reference Input RF Power(CW) @ Reference Input Power & Control -30°C to 70°C DC Voltage @ RF port (BNC-Female) Signal Input 0°C to 50°C VUSB Max. RF Power(CW) @ RF port FCPM-6000RC (N-Typ-Male) (Push-Pull connector) +25 dBm 25 V +13 dBm Permanent damage may occur if any of these limits are exceeded. Operating in the range between operating power limits and absolute maximum ratings for extended periods of time may result in reduced life and reliability. Mini-Circuits ® www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com Page 3 of 8 FCPM-6000RC Integrated Frequency Counter & Power Meter Typical Performance Curves VSWR Uncertainty of Power Measurement @ +25°C 0.2 1.15 0°C 1.12 0.1 UUncertainty (dB) +25°C +50°C VSWR (:1) 1.09 1.06 1.03 0.0 -0.1 -30 dBm -10 dBm 0 dBm +5 dBm +10 dBm +15 dBm +20 dBm -0.2 -0.3 -0.4 1.00 0 1000 2000 3000 4000 5000 0 6000 1000 Frequency (MHz) 2000 3000 4000 Frequency (MHz) 5000 6000 Linearity @ +25OC 8% -30 to 0 dBm 6% 0 to +20 dBm Linearity (%) 4% 2% 0% -2% -4% 0 1000 2000 3000 4000 5000 6000 Frequency (MHz) Typ. Input Power Threshhold for Frequency Measurement @ +25°C -27 Uncertainty of Frequency Measurement @ +25°C 500 Uncertainty (Hz) Power In (dBm) -30 dBm -20 dBm -10 dBm 0 dBm +5 dBm +15 dBm +20 dBm 300 -30 -33 -36 100 -100 -300 -39 -500 -42 0 1000 2000 3000 4000 Frequency (MHz) 5000 0 6000 Mini-Circuits 1000 2000 3000 4000 Frequency (MHz) 5000 6000 ® www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com Page 4 of 8 FCPM-6000RC Integrated Frequency Counter & Power Meter Outline Drawing (JL2029) Note 9 Indicates Grey per Pantone 427C Indicates Cutout P/N: B16-10-174+ REV: ORx1 Outline Dimensions ( inch mm ) 9 A B C D E F G H J K L WT. GRAMS 5.00 (127.0) 2.66 (67.6) 1.36 (34.5) 1.31 (33.3) 0.50 (12.7) 2.300 (58.42) 0.18 (4.6) 4.000 (101.60) 0.50 (12.7) 81 (2057) 20 (508) 500 FCPM-6000RC to be used with the supplied control cable only. Mini-Circuits ® www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com Page 5 of 8 FCPM-6000RC Integrated Frequency Counter & Power Meter Connection diagrams Connection diagram for USB control RJ45 connector - Not in use for USB control Push-Pull connector Connect to D.U.T. USB-RJ45-CBL-7+ USB Type A plug Connect to computer USB socket Reference input (connect to external reference if needed) Connection diagram for Ethernet control, using power adapter RJ45 connector - Connected to LAN network port USB Type A plug Connect to USB-AC/DC-5 power adaptor Push-Pull connector Connect to D.U.T. USB-RJ45-CBL-7+ USB-AC/DC-5 Reference input (connect to external reference if needed) Connection diagram for Ethernet control, using PoE system Push-Pull connector Connect to D.U.T. USB-RJ45-CBL-7+ Reference input (connect to external reference if needed) Note: Commercially available PoE splitter not supplied by Mini-Circuits RJ45 connector for LAN data PoE Splitter RJ45 connector Connected to PoE/LAN port USB Type A plug for +5V power only Mini-Circuits ® www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com Page 6 of 8 Integrated Frequency Counter & Power Meter FCPM-6000RC Software & Documentation Download: • Mini-Circuits’ full software and support package including user guide, Windows GUI, DLL files, programming manual and examples can be downloaded free of charge from https://www.minicircuits.com/softwaredownload/fcpm.html. Please contact testsolutions@minicircuits.com for support • Minimum System Requirements Parameter Requirements Interface USB HID or HTTP Get/Post or Telnet protocols System requirements GUI: Windows 32 & 64 bit systems from Windows 98 up to Windows 10 USB API (ActiveX & .Net) Windows 32 & 64 bit systems with ActiveX or .Net support from Windows 98 up to Windows 10 USB direct programming support Linux, Windows systems from Windows 98 up to Windows 10 HTTP or Telnet Any computer with a network port and Ethernet-TCP/IP (HTTP or Telnet protocols) support Hardware Pentium ® II or higher, RAM 256 MB Y control cable for USB and Ethernet (supplied) Model to be used with the supplied control cable only Graphical User Interface (GUI) for Windows Key Features: • • • • • • • • Automatically synchronized power and frequency measurements. Relative and Average power measurements Setting measurement speed for power and frequency independantly. Freq. & Power measurment data recording Measurement application tools online graphical display of power measurement USB, HTTP or Telnet control of FCPM Setting Ethernet configuration Application Programming Interface (API) Windows Support: • API DLL files exposing the full power sensor functionality • ActiveX COM DLL file for creation of 32-bit programs • .Net library DLL file for creation of 32 / 64-bit programs • HTTP Get/Post and Telnet protocols use SCPI commands to provide full control. • Supported by most common programming environments (refer to application note AN-49-001 for summary of tested environments) Linux Support: • Full power sensor control in a Linux environment is achieved by way of USB interrupt commands. Mini-Circuits ® www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com Page 7 of 8 Integrated Frequency Counter & Power Meter Ordering Information Model FCPM-6000RC Description FCPM-6000RC Integrated Frequency Counter & Power Meter Included Accessories Part No. Description USB-RJ45-CBL-7+ 6.6 ft (2 m) “Y” data cable with USB Type-A and RJ45 plug connectors 9 9 FCPM-6000RC to be used with the supplied control cable only. Optional Accessories Description USB-AC/DC-5 AC/DC 5VDC Power Adapter with US, EU, IL, UK, AUS, and China power plugs 10,11 USB-RJ45-CBL-7+ (spare) 6.6 ft (2 m) “Y” data cable with USB Type-A and RJ45 plug connectors NF-SM50+ N-Type Female to SMA Male Adapter (For mating with SMA devices). NF-SF50+ N-Type Female to SMA Female Adapter NF-BM50+ N-Type Female to BNC Male Adapter. 10 11 Power plugs for other countries are also available, if you need a power plug for a country not listed in the table please contact testsolutions@minicircuits. com for support. The USB-AC/DC-5 may be used to provide the 5VDC power input via USB port if operating with Ethernet control. Not required if using USB control. Calibration Description CAL-FCPM-6000RC Calibration Service Click Here Additional Notes A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document. B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions. C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp Mini-Circuits ® www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com Page 8 of 8
FCPM-6000RC 价格&库存

很抱歉,暂时无法提供与“FCPM-6000RC”相匹配的价格&库存,您可以联系我们找货

免费人工找货