AHF-10 Series
10 Watts Universal Input Range AC/DC Power Modules
Single and Dual Outputs
Key Features
High Efficiency up to 77% 85~265VAC, 47~440Hz Universal Input Range Single and Dual Output Modules I/O Isolation 3000VAC EMI Complies With EN55022 Class B and FCC part 15, level B EMC Complies With EN61000 MTBF > 300,000 Hours UL 60950-1 Safety Approval IEC61140 Safety Class II Approval Operating Temperature 71] (Reference to Derating Curve)
AHF-10 is a 10-Watt series of AC-DC power modules. These modules have universal input range of 85-265VAC and are available in output voltages of 3.3V, 5V, 12V, 15V, 24V, ±12 and ±15V with efficiency as high as 77%. Other features include continuous short circuit protection, overvoltage protection, output current limitation, EMC EN61000-4(-2,-3,-4) and EMI EN55022 level B approved which conducted noise compliance minimize design-in time, cost and eliminate the need for external components. The AHF-10 series has IEC / EN / UL 60950-1 safety approval qualifies this product for worldwide markets. The series is a wide variety of applications including in commercial and industrial of the MTBF 300,000 hours.
~
85 265 VAC
Universal Voltage
OVP
Protection
3000 VAC
I/O Isolation
EMI
EN55022
EMC
EN61000
Derating Curve
100 80 Output Power (%)
60
40 25% 20 0 -25
~ 10 20 30 40 50 60 70
Ambient Temperature ]
1
MINMAX
REV:9 2008/10
AHF-10 Series
Model Selection Guide
Model Number Output Voltage Output Current Max. mA 2000 2000 833 666 416 {380 {300 Min. mA 200 200 83 66 42 {38 {30 Capacitive Load Max. uF 3900 3300 2200 2200 1000 # 1000 # 1000 Input Current 115VAC, 60Hz @Max. Load @No Load mA (Typ.) mA (Typ.) 137 15 199 15 191 15 191 15 190 15 172 15 169 15 Efficiency @Max. Load % (Typ.) 70 73 76 76 76 77 77
AHF-10S03 AHF-10S05 AHF-10S12 AHF-10S15 AHF-10S24 AHF-10D12 AHF-10D15
#
VDC 3.3 5 12 15 24 {12 {15
For each output.
Environmental Specifications
Parameter Operating Temperature Storage Temperature Humidity Cooling Conducted EMI Conditions Ambient Min. Max. -25 71 -40 85 --95 Free-Air Convection EN55022 Class B specification requirement Air {8KV Cont. {4KV 80~1000MHz 10V/m 80% AM1KHz modulation AC port {2KV DC, SL, TL {2KV not less than 1 min. 1.2/50uS(8/20uS) AC dif. {1KV DC {0.5KV 0.15~80MHz 10Vrms (functional earth ports included) 80% AM 1kHz modulation 30% 10ms 60% 100ms 95% 5000ms Unit ] ] %
Note :
1. Specifications typical at Ta=+25], resistive load, 115VAC, 60Hz input voltage, rated output current unless otherwise noted. 2. Ripple & Noise measurement bandwidth is 0-20 MHz. 3. These power modules require a minimum output loading to maintain specified regulation. 4. Operation under no-load conditions will not damage these devices; however they may not meet all listed specifications. 5. Other input and output voltage may be available, please contact factory. 6. Specifications subject to change without notice. B
Standard EN61000-4-2
Performance Criteria B
EN61000-4-3
A
EN61000-4-4 Conducted EMC EN61000-4-5
B
EN61000-4-6
B
EN61000-4-11
B C C
Input Specifications
Parameter Input Voltage Range Input Frequency Range Inrush Current (Cold Start at 25]) Conditions All Models 115VAC 230VAC Min. 85 47 ----Typ. --------Max. 265 440 10 20 Unit VAC Hz A A
REV:9 2008/10
MINMAX
2
AHF-10 Series
Input Fuse
All Models Built-in Fuse External Fuse (Recommended) 2A / 250VAC 1.5A Slow - Blow Type
Output Specifications
Parameter Output Voltage Accuracy Line Regulation Load Regulation - Single output - Dual output Ripple & Noise (20MHz) Over Voltage Protection Temperature Coefficient Overshoot Current limitation Short circuit protection 85VAC, Hiccup technique, auto-recovery Vin=Min. to Max. Iout=Min. to Max. 3.3 & 5.0VDC Output Models Other Output Models Zener diode clamp Conditions Min. ------------------105 Typ. {1.0 {0.5 {0.5 {2.5 1.5 0.8 120 {0.01 ----Max. {2.0 {1.0 {1.0 {5.0 1.8 1.0 --{0.02 5.0 --Unit % % % % %Vpp of Vo %Vpp of Vo % of Vo %/] % %
Hiccup mode, indefinite (automatic recovery)
General Specifications
Parameter Isolation Voltage Isolation Test Voltage Isolation Resistance Switching Frequency Hold-up Time MTBF 115VAC, 60Hz MIL-HDBK-217F @ 25], Ground Benign Conditions Input to Output, 60 Seconds Input to Output, Flash Tested for 1 Second 500VDC Min. 3000 4700 100 ----300 Typ. ------100 20 --Max. ------------Unit VAC VDC M[ KHz ms K Hours
Block Diagram
Single Output
L EMI Filter and Inrush Current Limiter Rectifier Switching Device Rectifier OVP -Vo Control Circuit Isolation Ref.Amp +Vo
N
Fuse
Dual Output
L
L Fuse
N
N
Fuse
EMI Filter and Rectifier Lnrush Current Inrush Current Line Limiter Limiter and Filter Rectifier
Rectifier Switching Device Switching Device
Rectifier
+Vo
OVP OVP
+Vo Com. Com. -Vo -Vo
Rectifier Rectifier Isolation
Isolation
Control Circuit
PWM
Ref.Amp OVP
Ref.Amp
3
MINMAX
REV:9 2008/10
AHF-10 Series
Mechanical Dimensions
Pin Connections
Pin 1
19.0 [0.75] 10.16 [0.40] 10.16 [0.40] 6.0 [0.24] 0.5 [0.02]
Single Output
Dual Output
AC(N) - AC Neutral AC(L) - AC Line -Vout NC +Vout NC: No Connection Common
2 3 4 5
5
4
3
1.0 [ 0.04]
Bottom
54.0 [2.13]
64.0 [2.52]
Physical Characteristics
Side
Case Size
5.0 [0.20]
: : : :
64.0*45.0*19.0 mm 2.52*1.77*0.75 inches Plastic resin + Fiberglass 92 g UL94V-0
Case Material Weight
2
1
17.78 [0.70] 45.0 [1.77]
Flammability
Tolerance
Millimeters X.X{0.5 X.XX{0.25 {0.1
Inches X.XX{0.02 X.XXX{0.01 {0.004
Pin
REV:9 2008/10
MINMAX
4
很抱歉,暂时无法提供与“AHF-10S12”相匹配的价格&库存,您可以联系我们找货