AJM-24S12C

AJM-24S12C

  • 厂商:

    MINMAX(捷拓)

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
AJM-24S12C 数据手册
AJM-24 SERIES AC/DC Power Module 24W, Industrial & Medical Safety FEATURES ►Fully encapsulated Plastic Case ►3 Mounting Versions: - PCB Mounting with Solder Pins - Chassis Mounting with Screw Terminals - DIN-Rail Mounting ►Package Dimension 74x54x19.5 mm (PCB Version) ►Universal Input 85-264VAC, 47-440 Hz ►Protection Class ll ►Extended Operating Temp.Range -40°C to +65°C at full Load ►LED Output Indicator (Chassis Version Models) ►Eco Design, compliant to Energy Star specification and ErP Directive 2009/125/EC ►Industrial Safety to UL/IEC/EN 60950-1 and UL508 ►Medical Safety Approval to UL/IEC/EN 60601-1 3rd Edition ►Over Load and Over Temperature Protection ►3 Year Product Warranty PRODUCT OVERVIEW The new MINMAX AJM-24 series is a range of fully encapsulated AC/DC power modules. These high performance products feature an extended operating temperature range of -40°C to +80°C. Universal input voltage 85-264VAC and UL/IEC/EN safety approvals including medical safety and UL508 listing qualify these power supplies modules for applications in products with worldwide markets. The modules comply with the latest European ErP Directive and meet Energy Star requirements. EMI-filter meets EN55022, class B and FCC,part15, class B. The AJM-24 series power modules provide an economical solution for many space critical applications in commercial, medical and industrial electronic equipment. Model Selection Guide Model Number PCB Mounting Output (For model with Chassis Voltage Output Current Input Current Max. capacitive Load Max. 115VAC, 60Hz 230VAC, 50Hz @Max. Load Mounting, add suffix C) VDC 5 9 12 15 24 ±12 ±15 AJM-24S05 AJM-24S09 AJM-24S12 AJM-24S15 AJM-24S24 AJM-24D12 AJM-24D15 mA 3000 2666 2000 1600 1000 ±1000 ±800 (typ.) @Max. Load, 115VAC mA(typ.) 286 424 424 424 424 424 424 Efficiency µF 2200 1000 1000 680 470 470# 330# # For each output 172 255 255 255 255 255 255 % 76 82 82 82 82 82 82 Input Specifications Parameter Model Min. Typ. Max. Unit VAC AC Voltage Input Range 85 --- 264 Input Frequency Range 47 --- 440 Hz 120 --- 370 VDC W All Models DC Voltage Input Range No-Load Power Consumption Inrush Current (Cold Start at 25℃) E-mail:sales@minmax.com.tw 2014/03/31 REV:0 --- --- 0.3 115VAC --- --- 20 A 230VAC --- --- 35 A Tel:886-6-2923150 Page 1 of 5 AJM-24 SERIES AC/DC Power Module 24W, Industrial & Medical Safety Output Specifications Parameter Conditions Output Voltage Accuracy Line Regulation Min. Typ. --±2.0 --±0.5 Single Output Model --±0.5 Dual Output Models --±2.5 No minimum Load Requirement 1.5 5.0VDC Output Models --0-20 MHz Bandwidth Other Output Models --1.0 Load Regulation Min.Load Ripple & Noise Over Voltage Protection Temperature Coefficient Overshoot Zener diode clamp 85VAC, Hiccup Mode, auto-recovery (long term overload condition may cause damage) Current Limitation Short Circuit Protection Max. Unit --------- % % % % 1.8 1.3 %VPP of Vo %VPP of Vo ----- 120 ±0.02 --- --5 % of Vo %/℃ % 105 --- --- %Inom. Continous General Specifications Parameter Conditions I/O Isolation Voltage (reinforced) Leakage Current I/O Isolation Resistance Switching Frequency Hold-up Time MTBF (calculated) EMC Emission EMC Immunity according EN61000-6-1 Min. 500 VDC 115VAC, 60Hz 230VAC, 50Hz MIL-HDBK-217F@25℃, Ground Benign Conducted and radiated Standard EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 Protection Class II Safety Approvals Typ. Max. Unit 4000 ----VACrms --80 --µA 1000 ----MΩ --132 --KHz --20 --ms --80 --ms 400,000 ----Hours EN 55011 class B, EN 55022 class B, FCC part 15 class B Specification Requirement Performance Criteria Air ±8KV Cont. ±4KV B 80~1000MHz, 10V/m 80% AM, 1KHz modulation A AC port ±2KV DC, SL, TL ±2KV not less than 1 min. B 1.2/50µS(8/20µS) AC dif. ±2KV DC ±1KV B 0.15~80MHz, 10Vrms (functional earth ports included) B 80% AM, 1KHz modulation A 50Hz/60Hz, 30A/m 30%, 10ms B 60%, 100ms, 95%, 5000ms C According IEC/EN 60536 IEC/EN 60950-1, 60601-1 3rd, 2XMOPP cUL/UL 60950-1, 60601-1 3rd, 2XMOPP, UL 508 listed Environmental Specifications Parameter Conditions Ambient Above +65℃ Above +65℃ Temperature Range (operational) Power Derating (5V Output Models) Power Derating (Other Models) Storage Temperature Range Over Temperature Protection Humidity (non condensing) Cooling E-mail:sales@minmax.com.tw 2014/03/31 REV:0 -40℃ -40℃ Shutdown at 90℃ (automatic recovery at approx.67℃) --Free-Air convection Tel:886-6-2923150 Page 2 of 5 +80℃ 0.75W / ℃ 1.2W / ℃ +95℃ 95% rel. H AJM-24 SERIES AC/DC Power Module 24W, Industrial & Medical Safety Notes 1 This product is not designed for use in critical life support systems, equipment used in hazardous environment, nuclear control systems or other such 2 Specifications typical at Ta=+25℃, resistive load, 115VAC, 60Hz input voltage, after warm-up time rated output current unless otherwise noted. 3 Safety approvals cover frequency 47-63 Hz. 4 We recommend to protect the converter by a slow blow fuse in the input supply line. 5 Other input and output voltage may be available, please contact factory. 6 To order the module with chassis mount package, please add a suffix C (e.g. AJM-24S05C). 7 Part number for DIN-Rail mounting bracket: AC-DIN-01 8 That “natural convection” is about 20LFM but is not equal to still air (0 LFM). 9 Specifications are subject to change without notice. applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. Package Specifications PCB Mounting Mechanical Dimensions Pin Connections 6.0 [0.24] 7 11.43 [0.45] 6 5 0.7 [0.03] 8.89 [0.35] 11.43 [0.45] 4 3 1.0 [ 0.04] 8.89 [0.35] 74.0 [2.91] 6.3 [0.25] 41.4 [1.63] 62.0 [2.44] Mounting M4.0 Thread 6.3 [0.25] 19.5 [0.77] Pin Single Output Dual Output 1 AC (N) AC (N) 2 AC (L) AC (L) 3 No Pin No Pin 4 -Vout -Vout 5 No Pin Common 6 +Vout +Vout 7 No Pin No Pin 2 5.0 [0.20] 46.0 [1.81] Bottom View 1 ►All dimensions ►Pin 54.0 [2.13] Physical Characteristics Case Size : 74.0x54.0x19.5mm (2.91x2.13x0.77 inches) Case Material : Plastic resin + Fiberglass (flammability to UL 94V-0 rated) Pin Material : Copper Alloy with Gold Plate Over Nickel Subplate Weight : 137g E-mail:sales@minmax.com.tw 2014/03/31 REV:0 in mm (inches) ►Tolerance: ±0.5 20.32 [0.80] Tel:886-6-2923150 Page 3 of 5 (±0.02) diameter — 1.0 ±0.1 (0.04±0.004) AJM-24 SERIES AC/DC Power Module 24W, Industrial & Medical Safety Package Specifications Chassis Mounting (order code suffix C) Mechanical Dimensions Connections Indication LED 46.0 [1.81] 7 6 5 4 3 2 Top view 1 54.0 [2.13] 4 x 3.5 DCON Pin Single Output Dual Output 1 AC (N) AC (N) 2 AC (L) AC (L) 3 NC NC 4 -Vout -Vout 5 NC Common 6 +Vout +Vout 7 NC NC POWER"GOOD"INDICATOR 86.0 [3.39] 96.0 [3.78] NC: No Connection 10.0 [0.39] 5.0 [0.20] 16.8 [0.66] 23.3 [0.92] 76.0 [2.99] Physical Characteristics Case Size : 96.0x54.0x23.3mm (3.78x2.13x0.92 inches) Case Material : Plastic resin + Fiberglass (flammability to UL 94V-0 rated) Weight : 147g Package Specifications with DIN Rail Mounting Bracket Mechanical Dimensions Indication LED Top view 2 1 54.0 [2.13] 7 6 5 4 3 46.0 [1.81] 4 x 3.5 DCON POWER"GOOD"INDICATOR 86.0 [3.39] 96.0 [3.78] 3.0 [0.12] 23.3 [0.92] 11.0 [0.43] 5.0 [0.20] 10.0 [0.39] 16.8 [0.66] 76.0 [2.99] Physical Characteristics Case Size : 96.0x54.0x23.3mm (3.78x2.13x0.92 inches) Case Material : Plastic resin + Fiberglass (flammability to UL 94V-0 rated) Weight : 201g E-mail:sales@minmax.com.tw 2014/03/31 REV:0 Tel:886-6-2923150 Page 4 of 5 ►All dimensions in mm (inches) ►Tolerance: ±0.5 (±0.02) AJM-24 SERIES AC/DC Power Module 24W, Industrial & Medical Safety DIN-Rail Mounting Bracket (Order code for Kit : AC-DIN-01) Minmax Technology Co., Ltd. 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: sales@minmax.com.tw 2014/03/31 REV:0 Page 5 of 55
AJM-24S12C 价格&库存

很抱歉,暂时无法提供与“AJM-24S12C”相匹配的价格&库存,您可以联系我们找货

免费人工找货