AJM-24 SERIES
AC/DC Power Module 24W, Industrial & Medical Safety
FEATURES
►Fully encapsulated Plastic Case
►3 Mounting Versions:
- PCB Mounting with Solder Pins
- Chassis Mounting with Screw Terminals
- DIN-Rail Mounting
►Package Dimension 74x54x19.5 mm (PCB Version)
►Universal Input 85-264VAC, 47-440 Hz
►Protection Class ll
►Extended Operating Temp.Range -40°C to +65°C at full Load
►LED Output Indicator (Chassis Version Models)
►Eco Design, compliant to Energy Star specification and ErP
Directive 2009/125/EC
►Industrial Safety to UL/IEC/EN 60950-1 and UL508
►Medical Safety Approval to UL/IEC/EN 60601-1 3rd Edition
►Over Load and Over Temperature Protection
►3 Year Product Warranty
PRODUCT OVERVIEW
The new MINMAX AJM-24 series is a range of fully encapsulated AC/DC power modules. These high performance products feature an extended operating
temperature range of -40°C to +80°C. Universal input voltage 85-264VAC and UL/IEC/EN safety approvals including medical safety and UL508 listing
qualify these power supplies modules for applications in products with worldwide markets. The modules comply with the latest European ErP Directive and
meet Energy Star requirements. EMI-filter meets EN55022, class B and FCC,part15, class B.
The AJM-24 series power modules provide an economical solution for many space critical applications in commercial, medical and industrial electronic
equipment.
Model Selection Guide
Model Number PCB Mounting
Output
(For model with Chassis
Voltage
Output Current
Input Current
Max. capacitive
Load
Max.
115VAC, 60Hz
230VAC, 50Hz
@Max. Load
Mounting, add suffix C)
VDC
5
9
12
15
24
±12
±15
AJM-24S05
AJM-24S09
AJM-24S12
AJM-24S15
AJM-24S24
AJM-24D12
AJM-24D15
mA
3000
2666
2000
1600
1000
±1000
±800
(typ.)
@Max. Load, 115VAC
mA(typ.)
286
424
424
424
424
424
424
Efficiency
µF
2200
1000
1000
680
470
470#
330#
# For each output
172
255
255
255
255
255
255
%
76
82
82
82
82
82
82
Input Specifications
Parameter
Model
Min.
Typ.
Max.
Unit
VAC
AC Voltage Input Range
85
---
264
Input Frequency Range
47
---
440
Hz
120
---
370
VDC
W
All Models
DC Voltage Input Range
No-Load Power Consumption
Inrush Current (Cold Start at 25℃)
E-mail:sales@minmax.com.tw
2014/03/31 REV:0
---
---
0.3
115VAC
---
---
20
A
230VAC
---
---
35
A
Tel:886-6-2923150
Page 1 of 5
AJM-24 SERIES
AC/DC Power Module 24W, Industrial & Medical Safety
Output Specifications
Parameter
Conditions
Output Voltage Accuracy
Line Regulation
Min.
Typ.
--±2.0
--±0.5
Single Output Model
--±0.5
Dual Output Models
--±2.5
No minimum Load Requirement
1.5
5.0VDC Output Models
--0-20 MHz Bandwidth
Other Output Models
--1.0
Load Regulation
Min.Load
Ripple & Noise
Over Voltage Protection
Temperature Coefficient
Overshoot
Zener diode clamp
85VAC, Hiccup Mode, auto-recovery
(long term overload condition may cause damage)
Current Limitation
Short Circuit Protection
Max.
Unit
---------
%
%
%
%
1.8
1.3
%VPP of Vo
%VPP of Vo
-----
120
±0.02
---
--5
% of Vo
%/℃
%
105
---
---
%Inom.
Continous
General Specifications
Parameter
Conditions
I/O Isolation Voltage (reinforced)
Leakage Current
I/O Isolation Resistance
Switching Frequency
Hold-up Time
MTBF (calculated)
EMC Emission
EMC Immunity according EN61000-6-1
Min.
500 VDC
115VAC, 60Hz
230VAC, 50Hz
MIL-HDBK-217F@25℃, Ground Benign
Conducted and radiated
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Protection Class II
Safety Approvals
Typ.
Max.
Unit
4000
----VACrms
--80
--µA
1000
----MΩ
--132
--KHz
--20
--ms
--80
--ms
400,000
----Hours
EN 55011 class B, EN 55022 class B, FCC part 15 class B
Specification Requirement
Performance Criteria
Air ±8KV Cont. ±4KV
B
80~1000MHz, 10V/m 80% AM, 1KHz modulation
A
AC port ±2KV DC, SL, TL ±2KV not less than 1 min.
B
1.2/50µS(8/20µS) AC dif. ±2KV DC ±1KV
B
0.15~80MHz, 10Vrms (functional earth ports included)
B
80% AM, 1KHz modulation
A
50Hz/60Hz, 30A/m
30%, 10ms
B
60%, 100ms, 95%, 5000ms
C
According IEC/EN 60536
IEC/EN 60950-1, 60601-1 3rd, 2XMOPP
cUL/UL 60950-1, 60601-1 3rd, 2XMOPP, UL 508 listed
Environmental Specifications
Parameter
Conditions
Ambient
Above +65℃
Above +65℃
Temperature Range (operational)
Power Derating (5V Output Models)
Power Derating (Other Models)
Storage Temperature Range
Over Temperature Protection
Humidity (non condensing)
Cooling
E-mail:sales@minmax.com.tw
2014/03/31 REV:0
-40℃
-40℃
Shutdown at 90℃ (automatic recovery at approx.67℃)
--Free-Air convection
Tel:886-6-2923150
Page 2 of 5
+80℃
0.75W / ℃
1.2W / ℃
+95℃
95% rel. H
AJM-24 SERIES
AC/DC Power Module 24W, Industrial & Medical Safety
Notes
1
This product is not designed for use in critical life support systems, equipment used in hazardous environment, nuclear control systems or other such
2
Specifications typical at Ta=+25℃, resistive load, 115VAC, 60Hz input voltage, after warm-up time rated output current unless otherwise noted.
3
Safety approvals cover frequency 47-63 Hz.
4
We recommend to protect the converter by a slow blow fuse in the input supply line.
5
Other input and output voltage may be available, please contact factory.
6
To order the module with chassis mount package, please add a suffix C (e.g. AJM-24S05C).
7
Part number for DIN-Rail mounting bracket: AC-DIN-01
8
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
9
Specifications are subject to change without notice.
applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet.
Package Specifications PCB Mounting
Mechanical Dimensions
Pin Connections
6.0 [0.24]
7
11.43
[0.45]
6
5
0.7 [0.03]
8.89
[0.35]
11.43
[0.45]
4
3
1.0 [ 0.04]
8.89
[0.35]
74.0 [2.91]
6.3
[0.25]
41.4 [1.63]
62.0 [2.44]
Mounting M4.0 Thread
6.3
[0.25]
19.5 [0.77]
Pin
Single Output
Dual Output
1
AC (N)
AC (N)
2
AC (L)
AC (L)
3
No Pin
No Pin
4
-Vout
-Vout
5
No Pin
Common
6
+Vout
+Vout
7
No Pin
No Pin
2
5.0 [0.20]
46.0 [1.81]
Bottom View
1
►All dimensions
►Pin
54.0 [2.13]
Physical Characteristics
Case Size
:
74.0x54.0x19.5mm (2.91x2.13x0.77 inches)
Case Material
:
Plastic resin + Fiberglass (flammability to UL 94V-0 rated)
Pin Material
:
Copper Alloy with Gold Plate Over Nickel Subplate
Weight
:
137g
E-mail:sales@minmax.com.tw
2014/03/31 REV:0
in mm (inches)
►Tolerance: ±0.5
20.32 [0.80]
Tel:886-6-2923150
Page 3 of 5
(±0.02)
diameter — 1.0 ±0.1 (0.04±0.004)
AJM-24 SERIES
AC/DC Power Module 24W, Industrial & Medical Safety
Package Specifications Chassis Mounting (order code suffix C)
Mechanical Dimensions
Connections
Indication LED
46.0 [1.81]
7
6
5
4
3
2
Top view
1
54.0 [2.13]
4 x 3.5
DCON
Pin
Single Output
Dual Output
1
AC (N)
AC (N)
2
AC (L)
AC (L)
3
NC
NC
4
-Vout
-Vout
5
NC
Common
6
+Vout
+Vout
7
NC
NC
POWER"GOOD"INDICATOR
86.0 [3.39]
96.0 [3.78]
NC: No Connection
10.0 [0.39]
5.0 [0.20]
16.8 [0.66]
23.3 [0.92]
76.0 [2.99]
Physical Characteristics
Case Size
:
96.0x54.0x23.3mm (3.78x2.13x0.92 inches)
Case Material
:
Plastic resin + Fiberglass (flammability to UL 94V-0 rated)
Weight
:
147g
Package Specifications with DIN Rail Mounting Bracket
Mechanical Dimensions
Indication LED
Top view
2
1
54.0 [2.13]
7
6
5
4
3
46.0 [1.81]
4 x 3.5
DCON
POWER"GOOD"INDICATOR
86.0 [3.39]
96.0 [3.78]
3.0 [0.12]
23.3 [0.92]
11.0 [0.43]
5.0
[0.20]
10.0 [0.39]
16.8 [0.66]
76.0 [2.99]
Physical Characteristics
Case Size
:
96.0x54.0x23.3mm (3.78x2.13x0.92 inches)
Case Material
:
Plastic resin + Fiberglass (flammability to UL 94V-0 rated)
Weight
:
201g
E-mail:sales@minmax.com.tw
2014/03/31 REV:0
Tel:886-6-2923150
Page 4 of 5
►All dimensions
in mm (inches)
►Tolerance: ±0.5
(±0.02)
AJM-24 SERIES
AC/DC Power Module 24W, Industrial & Medical Safety
DIN-Rail Mounting Bracket (Order code for Kit : AC-DIN-01)
Minmax Technology Co., Ltd.
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: sales@minmax.com.tw
2014/03/31 REV:0
Page 5 of 55