0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MSKW3033

MSKW3033

  • 厂商:

    MINMAX(捷拓)

  • 封装:

  • 描述:

    MSKW3033 - MSKW3000 Series - Minmax Technology Co., Ltd.

  • 数据手册
  • 价格&库存
MSKW3033 数据手册
MSKW3000 Series 5W, Ultra-Wide Input Range SMD, Single & Dual Output DC/DC Converters Key Features Efficiency up to 83% High Power Density 4:1 Input Range I / O Isolation 1500VDC Remote on/off Control SMT Technology Short Circuit Protection EMI Complies With EN55022 Class A MTBF > 1,000,000 Hours 1500 VDC Low Profile SMD Remote on/off EMI EN55022 4:1 Wide Range I/O Isolation Minmax's MSKW3000-Series are in “ gull-wing” SMT package. The series consists of 14 models with input voltage ranges of 9-36VDC and 18-75VDC which provide precisely regulated output voltages of 3.3V, 5V, 12V, 15V, {5V, {12V and {15VDC. The -40] to +71] operating temperature range makes it ideal for data communication equipments, mobile battery driven equipments, distributed power systems, telecommunication equipments, mixed analog/digital subsystems, process/machine control equipments, computer peripheral systems and industrial robot systems. The modules have a maximum power rating of 5W and a typical full-load efficiency of 83%, continuous short circuit,Remote on/off EN55022 Class A conducted noise compliance minimize design-in time, cost and eliminate the need for external filtering. Absolute Maximum Ratings Input Surge Voltage ( 1000 mS ) Parameter 24VDC Input Models 48VDC Input Models Lead Temperature (1.5mm from case for 10 Sec.) Internal Power Dissipation Min. -0.7 -0.7 ----Max. 50 100 260 2,500 Unit VDC VDC ] mW Environmental Specifications Parameter Operating Temperature Operating Temperature Storage Temperature Humidity Cooling Conducted EMI Conditions Ambient Case Min. -40 -40 -40 --Max. +71 +90 125 95 Unit ] ] ] % Exceeding the absolute maximum ratings of the unit could cause damage. These are not continuous operating ratings. Free-Air Convection EN55022 Class A Leadfree Reflow Solder Process as per IPC/JEDEC J-STD-020C peak temp. 245C/10 sec. 1 MINMAX REV:3 2008/10 MSKW3000 Series Model Selection Guide Model Number Input Voltage Output Voltage Output Current Input Current Reflected Ripple Current mA (Typ.) Efficiency VDC MSKW3021 MSKW3022 MSKW3023 MSKW3024 MSKW3025 MSKW3026 MSKW3027 MSKW3031 MSKW3032 MSKW3033 MSKW3034 MSKW3035 MSKW3036 MSKW3037 24 ( 9 ~ 36 ) 48 ( 18 ~ 75 ) VDC 3.3 5 12 15 {5 {12 {15 3.3 5 12 15 {5 {12 {15 Max. mA 1200 1000 417 333 {500 {208 {167 1200 1000 417 333 {500 {208 {167 Min. mA 120 100 41.7 33.3 {50 {20.8 {16.7 120 100 41.7 33.3 {50 {20.8 {16.7 @Max. Load mA (Typ.) 217 260 251 251 260 251 252 109 130 126 125 130 125 126 @No Load mA (Typ.) 20 15 10 10 @Max. Load % (Typ.) 76 80 83 83 80 83 83 76 80 83 83 80 83 83 Capacitive Load Models by Vout Maximum Capacitive Load # For each output 3.3V 2000 5V 2000 12V 470 15V 330 {5V # 680 {12V # 330 {15V # 220 Unit uF Input Fuse Selection Guide 24V Input Models 1500mA Slow-Blow type 48V Input Models 750mA Slow-Blow type Input Specifications Parameter Start Voltage Under Voltage Shutdown Reverse Polarity Input Current Short Circuit Input Power Input Filter All Models Model 24V Input Models 48V Input Models 24V Input Models 48V Input Models Min. 7 14 6 13 ----Typ. 8 16 7 15 --1000 Pi Filter Max. 9 18 8 17 1 3000 A mW VDC Unit REV:3 2008/10 MINMAX 2 MSKW3000 Series Output Specifications Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20MHz) Ripple & Noise (20MHz) Ripple & Noise (20MHz) Over Power Protection Transient Recovery Time Transient Response Deviation Temperature Coefficient Output Short Circuit 25% Load Step Change Over Line, Load & Temp. Dual Output, Balanced Loads Vin=Min. to Max. Io=10% to 100% Conditions Min. --------------115 ------Continuous Typ. {0.5 {0.5 {0.2 {0.3 50 ------250 {2 {0.01 Max. {2.0 {3.0 {1.0 {1.0 85 100 15 --500 {6 {0.02 Unit % % % % mV P-P mV P-P mV rms % uS % %/] General Specifications Parameter Isolation Voltage Rated Isolation Voltage Test Isolation Resistance Isolation Capacitance Switching Frequency MTBF MIL-HDBK-217F @ 25], Ground Benign Conditions 60 Seconds Flash Tested for 1 Second 500VDC 100KHz,1V Min. 1500 1650 1000 ----1000 Typ. ------650 340 --Max. ------750 ----Unit VDC VDC M[ pF KHz K Hours Remote On/Off Control Parameter Supply On Supply off Device Standby Input Current Control Input Current ( on ) Control Input Current ( off ) Control Common Vin=Min. to Max. Vin=Min. to Max. Conditions Min. -0.7 ------Typ. --------Max. 0.8 10 -600 -700 Unit VDC mA uA uA 2.5 to 5.5 VDC or Open Circuit Referenced to Negative Input Notes: 1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted. 2.Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. 3. Ripple & Noise measurement bandwidth is 0-20 MHz. 4. These power converters require a minimum output loading to maintain specified regulation. 5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 6. All DC/DC converters should be externally fused at the front end for protection 7. Other input and output voltage may be available, please contact factory. 8. Specifications subject to change without notice. 9. It is not recommended to use water-washing process on SMT units. 3 MINMAX REV:3 2008/10 MSKW3000 Series Block Diagram Single Output Dual Output +Vin LC Filter +Vo +Vin LC Filter +Vo Com. -Vo -Vin On/OFF PFM Isolation Ref.Amp -Vin On/OFF PFM Isolation Ref.Amp -Vo Input Voltage Transient Rating 150 140 130 120 110 100 Vin ( VDC ) 90 80 70 60 50 40 30 20 10 0 10uS 100uS 1mS 10mS 100mS 24VDC Input Models 48VDC Input Models REV:3 2008/10 MINMAX 4 MSKW3000 Series 90 90 80 Efficiency (%) Efficiency (%) 80 70 70 60 60 50 Low Nom Input Voltage (V) High 50 Low Nom Input Voltage (V) High Efficiency vs Input Voltage ( Single Output ) Efficiency vs Input Voltage ( Dual Output ) 90 80 70 Efficiency (%) 60 50 40 30 20 10 20 40 60 80 100 Load Current(%) 90 80 70 60 50 40 30 20 10 20 40 60 80 100 Load Current(%) Efficiency vs Output Load ( Single Output ) 100 80 Output Power (%) 100LFM Natural convection 400LFM Efficiency vs Output Load ( Dual Output ) 200LFM 60 40 20 0 -40 ~ 50 60 70 80 ] 90 100 110 Ambient Temperature Derating Curve 5 MINMAX REV:3 2008/10 MSKW3000 Series Test Configurations Input Reflected-Ripple Current Test Setup Input reflected-ripple current is measured with a inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0[ at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz. To Oscilloscope + Battery + Lin Current Probe +Vin +Out Load Maximum Capacitive Load The MSKW2000 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. For optimum performance we recommend 100uF maximum capacitive load for dual outputs and 680uF capacitive load for single outputs. The maximum capacitance can be found in the data sheet. DC / DC Converter -Vin -Out Overcurrent Protection To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back into its specified range. Cin Peak-to-Peak Output Noise Measurement Test Use a Cout 0.47uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0[ at 100 KHz) capacitor of a 3.3uF for the 12V input devices and a 2.2uF for the 24V and 48V devices. +Vin Single Output DC / DC Converter -Vin +Out Copper Strip Cout Scope Resistive Load -Out +Vin Dual Output DC / DC Converter -Vin +Out Com. Copper Strip Cout Cout Scope Resistive Load Scope + DC Power Source + Cin +Vin DC / DC Converter -Vin +Out Load -Out -Out Design & Feature Considerations Input Source I Remote On/Off Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn the power module on and off, the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. The switch can be an open collector or equivalent. A logic low is -0.7V to 0.8V. A logic high is 2.5V to 5.5V. The maximum sink current of the switch at on/off terminal during a logic low is 300 uA. The maximum sink current of the switch at on/off terminal = 2.5 to 5.5V is 200uA or open. REV:3 2008/10 Output Ripple Reduction MINMAX 6 MSKW3000 Series A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 3.3uF capacitors at the output. + DC Power Source - +Vin Single Output DC / DC Converter -Vin +Out Cout -Out Load + DC Power Source - +Vin +Out Dual Output Com. DC / DC Converter Cout Load -Vin -Out Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 90° C. The derating curves are determined from measurements obtained in an experimental apparatus. Position of air velocity probe and thermocouple 15mm / 0.6in 50mm / 2in Air Flow DUT 5 MINMAX REV:3 2008/10 MSKW3000 Series Mechanical Dimensions Connecting Pin Patterns Top View ( 2.54 mm / 0.1 inch grids ) 15.26 [0.601] 24 23 22 16 15 14 13 20.6 [0.81] 25.6 [1.01] 22.6 [0.89] 27.94mm 3.0mm Top 1 2 3 9 10 11 12 27.0mm 2.54 [0.100] 33.4 [1.31] 2.7 [0.11] Side 10.2 [0.40] 2.54mm 15.24mm 1.9mm Tolerance Millimeters X.X{0.25 X.XX{0.13 {0.05 0.4 [0.01] 1.50 [0.059] 0.15 Inches X.XX{0.01 X.XXX{0.005 {0.002 Pin Pin Connections Pin 1 2 3 9 10 11 12 13 14 15 16 22 23 24 Single Output Remote On/Off -Vin -Vin NC NC NC NC NC +Vout NC -Vout +Vin +Vin NC NC: No Connection Dual Output Remote On/Off -Vin -Vin Common NC -Vout NC NC +Vout NC Common +Vin +Vin NC Physical Characteristics Case Size : 33.4*20.6*10.2 mm 1.31*0.81*0.40 inches Non-Conductive Black Plastic 14g UL94V-0 Case Material Weight Flammability : : : REV:3 2008/10 MINMAX 8
MSKW3033 价格&库存

很抱歉,暂时无法提供与“MSKW3033”相匹配的价格&库存,您可以联系我们找货

免费人工找货