MSLU400 Series
2W, Miniature SMD, Single & Dual Output DC/DC Converters
Key Features
Efficiency up to 80% 1500VDC Isolation MTBF > 2,000,000 Hours Low Cost Input 5, 12 and 24VDC Output 3.3, 5, 12, {5, {12 and {15VDC Temperature Performance -25] to +75] Lead Frame Technology UL 94V-0 Package Material Internal SMD Construction
1500 VDC
SMD
$
Low Cost Low Profile
I/O Isolation
Minmax's MSLU400 2W DC/DC's are in "gull-wing" SMT package, weigh a mere 2.2 grams. The series consists of 18 models with input voltages of 5V,12V and 24VDC which offers standard output voltages of 3.3V, 5V, 12V, {5V, {12V and {15VDC for the choice. Their impressive guaranteed efficiencies enable all models to deliver their fully rated output power from -25] to +75] without heat sinking or forced-air cooling. The MSLU400 series are excellent selections for a variety of applications including data communication equipments, distributed power systems, telecommunication equipments and industrial robot systems. The MSLU400 units are available in tape and reel package.
Absolute Maximum Ratings
Parameter Input Surge Voltage ( 1000 mS ) 5VDC Input Models 12VDC Input Models 24VDC Input Models Min. -0.7 -0.7 -0.7 ----Max. 9 18 30 300 650 Unit VDC VDC VDC ] mW
Environmental Specifications
Parameter Operating Temperature Operating Temperature Storage Temperature Humidity Cooling Conditions Ambient Case Min. -25 -25 -25 --Max. +75 +90 +125 95 Unit ] ] ] %
Lead Temperature (1.5mm from case for 10 Sec.) Internal Power Dissipation
Free-Air Convection
Exceeding the absolute maximum ratings of the unit could cause damage. These are not continuous operating ratings. Leadfree Reflow Solder Process as per IPC/JEDEC J-STD-020C peak temp. 245C/10 sec.
1
MINMAX
REV:4 2009/01/20
MSLU400 Series
Model Selection Guide
Model Number Input Voltage Output Voltage Output Current Input Current Load Regulation Efficiency
VDC MSLU401 MSLU402 MSLU404 MSLU406 MSLU408 MSLU409 MSLU411 MSLU412 MSLU414 MSLU418 MSLU419 MSLU421 MSLU422 MSLU424 MSLU428 MSLU429
5 (4.5 ~ 5.5)
12 (10.8 ~ 13.2)
24 (21.6 ~ 26.4)
VDC 3.3 5 12 {5 {12 {15 3.3 5 12 {12 {15 3.3 5 12 {12 {15
Max. mA 500 400 165 {200 {83 {66 500 400 165 {83 {66 500 400 165 {83 {66
Min. mA 10 8 3 {4 {1.5 {1 10 8 3 {1.5 {1 10 8 3 {1.5 {1
@Max. Load mA (Typ.) 471 548 514 541 524 521 191 222 209 208 206 96 111 105 105 104
@No Load mA (Typ.)
60
30
15
% (Max.) 11 11 11 10 7 7 8 8 5 5 5 8 8 5 5 5
@Max. Load % (Typ.) 70 73 77 74 76 76 72 75 79 80 80 72 75 79 79 79
Capacitive Load
Models by Vout Maximum Capacitive Load # For each output 3.3V 47 5V 47 12V 10 {5V # 10 {12V # 4.7 {15V # 4.7 Unit uF
Input Fuse Selection Guide
5V Input Models 1000mA Slow - Blow Type 12V Input Models 500mA Slow - Blow Type 24V Input Models 200mA Slow - Blow Type
Input Specifications
Parameter Input Voltage Range Reverse Polarity Input Current Input Filter Model 5V Input Models 12V Input Models 24V Input Models All Models Min. 4.5 10.8 21.6 --Typ. 5 12 24 --Max. 5.5 13.2 26.4 0.3 A VDC Unit
Internal Capacitor
REV:4 2009/01/20
MINMAX
2
MSLU400 Series
Output Specifications
Parameter Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20MHz) Ripple & Noise (20MHz) Ripple & Noise (20MHz) Temperature Coefficient Output Short Circuit Over Line, Load & Temp. Conditions Dual Output, Balanced Loads For Vin Change of 1% Io=20% to 100% Min. ------------0.5 Second Max. Typ. {0.1 {1.2 100 ----{0.01 Max. {1.0 {1.5 120 200 15 {0.02 Unit % % % mV P-P mV P-P mV rms %/]
See Model Selection Guide
General Specifications
Parameter Isolation Voltage Rated Isolation Voltage Test Isolation Resistance Isolation Capacitance Switching Frequency MTBF MIL-HDBK-217F @ 25], Ground Benign Conditions 60 Seconds Flash Tested for 1 Second 500VDC 100KHz,1V Min. 1500 1650 10 --50 2000 Typ. ------60 100 --Max. ------100 120 --Unit VDC VDC G[ pF KHz K Hours
Notes :
1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted. 2. Ripple & Noise measurement bandwidth is 0-20 MHz. 3. These power converters require a minimum output loading to maintain specified regulation. 4. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 5. All DC/DC converters should be externally fused on the front end for protection. 6. Other input and output voltage may be available, please contact factory. 7. Specifications subject to change without notice. 8. It is not recommended to use water-washing process on SMT units.
Block Diagram
Single Output Dual Output
+Vo +Vin Bipolar Push-Pull Inverter -Vin -Vo
-Vin +Vin Bipolar Push-Pull Inverter
+Vo
Com.
-Vo
3
MINMAX
REV:4 2009/01/20
MSLU400 Series
3.3V & 5V output types.
+20% +15% +10% +5% Vnom -5% -10% 0%
Max. Typ. Min.
All other types.
+20% +15% +10% +5% Vnom -5% -10% 100%
+20% +15% +10%
Max.
+20% +15% +10% +5% Vnom
Min.
Output Voltage(%)
Output Voltage(%)
+5% Vnom -5% -10% 0%
Typ.
-5% -10% 100%
20%
40%
60%
80%
20%
40%
60%
80%
Output Load Current (%)
Output Load Current (%)
Tolerance Envelopes Graph (3.3V & 5V Output)
Tolerance Envelopes Graph (All other Output)
REV:4 2009/01/20
MINMAX
4
MSLU400 Series
Test Configurations
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with a inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0[ at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.
To Oscilloscope + Battery + Lin Current Probe +Vin +Out Load
Capacitor mounted close to the power module helps ensure stability of the unit, it is comended to use a good quality low Equivalent Series Resistance (ESR < 1.0[ at 100 KHz) capacitor of a 2.2uF for the 5V input devices, a 1.0uF for the 12V input devices and a 0.47uF for the 24V devices.
Output Ripple Reduction
+ DC Power Source + Cin -Vin -Out +Vin DC / DC Converter +Out Load
DC / DC Converter -Vin -Out
Cin
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.33uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter.
+Vin Single Output DC / DC Converter -Vin -Out +Out Copper Strip Cout Copper Strip Scope Resistive Load
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 1.5uF capacitors at the output.
+ DC Power Source -
+Vin Single Output DC / DC Converter -Vin
+Out
Cout -Out
Load
+ DC Power Source
+Vin
+Out Dual Output Com. DC / DC Converter Cout Load
+Vin Dual Output DC / DC Converter -Vin
+Out Com. -Out
Copper Strip Cout Copper Strip Cout Copper Strip Scope Scope Resistive Load
-
-Vin
-Out
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 90° C. The derating curves are determined from measurements obtained in an experimental apparatus.
Design & Feature Considerations
Maximum Capacitive Load
The MSLU400 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Position of air velocity probe and thermocouple 15mm / 0.6in
50mm / 2in
Air Flow
DUT
5
MINMAX
REV:4 2009/01/20
MSLU400 Series
Mechanical Dimensions
Single Output
0.25 [0.01]
8 5
Connecting Pin Patterns
Top View ( 2.54 mm / 0.1 inch grids )
9.3 [0.37]
7.62mm
0~4 °
R0.5 1 2 4
1.8mm 11.3mm 2.54mm
13.7 [0.54]
13.3 [0.52] 13.0 [0.51]
7.0 [0.28]
8.6 [0.34]
8.9 [0.35]
SEATING PLANE
13.1mm
3.04 [0.12]
2.54 [0.10]
5.08 [0.20]
(Magnification of A)
1.3mm Min
A
1.6 [0.06]
0.3 [0.01]
0.6 [0.02]
1.5 ±0.1 [0.06±0.004] 6.15 [0.24]
1.5 ±0.1 [0.06±0.004] 6.15 [0.24]
c 0.15 M S
12.3 [0.48]
Dual Output
10 7
9.3 [0.37]
0.25 [0.01]
1
2
4
5
0~4 °
R0.5
7.62mm 1.8mm
13.1mm
7.0 [0.28]
16.3 [0.64]
16.0 [0.63] 15.7 [0.62]
8.6 [0.34]
8.9 [0.35]
SEATING PLANE
2.54mm
11.3mm
3.07 [0.12]
2.54 [0.10]
5.08 [0.20]
2.54 [0.10]
(Magnification of A)
1.3mm Min
A
1.6 [0.06]
0.3 [0.01]
0.6 [0.02]
1.5 ±0.1 [0.06±0.004] 6.15 [0.24]
1.5 ±0.1 [0.06±0.004] 6.15 [0.24]
c 0.15 M S
12.3 [0.48]
Tolerance
Millimeters X.X{0.25 X.XX{0.13
Inches X.XX{0.01 X.XXX{0.005 {0.002
Pin
{0.05
REV:4 2009/01/20
MINMAX
6
MSLU400 Series
Pin Connections
Pin 1 2 4 5 7 8 10 Single Output -Vin +Vin -Vout +Vout No Pin NA No Pin Dual Output -Vin +Vin Common -Vout +Vout No Pin NA Weight (Single Output) : Weight (Dual Output) NA : Not Available for Electrical Connection Flammability : UL94V-0 : 1.5g 2.2g Case Material : Non-Conductive Black Plastic Case Size (Dual Output) : 16.3*9.3*8.7 mm 0.64*0.37*0.34 inches
Physical Characteristics
Case Size (Single Output) : 13.7*9.3*8.7 mm 0.54*0.37*0.34 inches
7
MINMAX
REV:4 2009/01/20