0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
S2D11R

S2D11R

  • 厂商:

    MINMAX(捷拓)

  • 封装:

  • 描述:

    S2D11R - 2-3W, High Isolation DIP, Single & Dual Output DC/DC Converters - Minmax Technology Co., Lt...

  • 数据手册
  • 价格&库存
S2D11R 数据手册
S2D00R Series 2-3W, High Isolation DIP, Single & Dual Output DC/DC Converters Key Features Low Cost 3000VDC Isolation MTBF > 800,000 Hours 40mV P-P Ripple and Noise Input 5, 12 and 24VDC Output 5, 12, 15, {12 and {15VDC Temperature Performance -25] to +71] Short Circuit Protection UL 94V-0 Package Material Internal SMD Construction Minmax's S2D00R Model 2-3W DC/DC's are specially designed to provide high levels of isolation 3000VDC in a low-profile 24-pin DIP package. The series consists of 15 models with input voltages of 5V, 12V and 24VDC which offers regulated output voltages of 5V, 12V, 15V, {12V and {15VDC. The S2D00R series is an excellent selection for a variety of applications including mixed analog/digital subsystems, railroad/transportation equipments, medical equipment subsystems, process/machine control equipments, automatic test instrumentation. $ Low Cost 3000 VDC I/O Isolation Low Noise Block Diagram Single Output Dual Output +Vin LC Filter -Vin Bipolar Push-Pull Inverter Low Dropout Regulator +Vo +Vin LC Filter -Vin -Vo Bipolar Push-Pull Inverter Positive Regulator +Vo Com. Negative Regulator -Vo 1 MINMAX REV:0 2005/04 S2D00R Series Model Selection Guide Model Number Input Voltage Output Voltage Output Current Input Current Reflected Ripple Current mA (Typ.) Efficiency VDC S2D01R S2D02R S2D03R S2D04R S2D05R S2D06R S2D07R S2D08R S2D09R S2D10R S2D11R S2D12R S2D13R S2D14R S2D15R 5 (4.75 ~ 5.25) 12 (10.8 ~ 13.2) 24 (21.6 ~ 26.4) VDC 5 12 15 {12 {15 5 12 15 {12 {15 5 12 15 {12 {15 Max. mA 400 165 133 {83 {66 400 165 200 {83 {100 400 165 200 {83 {100 Min. mA 0 0 0 @Max. Load mA (Typ.) 666 628 633 642 639 277 262 397 268 403 138 131 198 134 202 @No Load mA (Typ.) 100 70 50 30 25 15 @Max. Load % (Typ.) 60 63 63 62 62 60 63 63 62 62 60 63 63 62 62 Absolute Maximum Ratings Parameter 5VDC Input Models Input Surge Voltage 12VDC Input Models ( 1000 mS ) 24VDC Input Models Lead Temperature (1.5mm from case for 10 Sec.) Internal Power Dissipation Min. -0.7 -0.7 -0.7 ----Max. 7.5 15 30 260 3,000 Unit VDC VDC VDC ] mW Notes : 1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted. 2. Transient recovery time is measured to within 1% error band for a step change in output load of 50% to 100%. 3. Ripple & Noise measurement bandwidth is 0-20 MHz. 4. All DC/DC converters should be externally fused at the front end for protection. 5. Other input and output voltage may be available, please contact factory. Exceeding the absolute maximum ratings of the unit could cause damage. These are not continuous operating ratings. Environmental Specifications Parameter Operating Temperature Operating Temperature Storage Temperature Humidity Cooling Conditions Ambient Case Min. Max. -25 +71 -25 +90 -40 +125 --95 Free-Air Convection Unit ] ] ] % 6. Specifications subject to change without notice. REV:0 2005/04 MINMAX 2 S2D00R Series Input Specifications Parameter Input Voltage Range Model 5V Input Models 12V Input Models 24V Input Models Reverse Polarity Input Current Short Circuit Input Power Input Filter All Models Min. 4.75 10.8 21.6 ----Typ. 5 12 24 ----Pi Filter Max. 5.25 13.2 26.4 0.5 2500 A mW VDC Unit Output Specifications Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20MHz) Ripple & Noise (20MHz) Ripple & Noise (20MHz) Over Load Transient Recovery Time Transient Response Deviation Temperature Coefficient Output Short Circuit 50% Load Step Change Over Line, Load & Temp. Dual Output, Balanced Loads Vin=Min. to Max. Io=10% to 100% Conditions Min. --------------120 ------Continuous Typ. {2.0 {1.0 {0.2 {0.2 40 ----------{0.01 Max. {4.0 {3.0 {0.5 {0.5 50 75 5 --50 {6 {0.02 Unit % % % % mV P-P mV P-P mV rms % uS % %/] General Specifications Parameter Isolation Voltage Rated Isolation Voltage Test Isolation Resistance Isolation Capacitance Switching Frequency MTBF MIL-HDBK-217F @ 25], Ground Benign Conditions 60 Seconds Flash Tested for 1 Second 500VDC 100KHz,1V Min. 3000 3300 1000 --40 800 Typ. ------50 80 --Max. ------100 ----Unit VDC VDC M[ pF KHz K Hours Capacitive Load Models by Vout Maximum Capacitive Load # For each output 5V 470 12V 470 15V 470 {12V # 220 {15V # 220 Unit uF Input Fuse Selection Guide 5V Input Models 1000mA Slow - Blow Type 12V Input Models 750mA Slow - Blow Type 24V Input Models 350mA Slow - Blow Type 3 MINMAX REV:0 2005/04 S2D00R Series 100 90 Efficiency (%) 80 70 60 50 Efficiency (%) 100 90 80 70 60 50 Low Nom Input Voltage (V) High Low Nom Input Voltage (V) High Efficiency vs Input Voltage ( Single Output ) Efficiency vs Input Voltage ( Dual Output ) 90 80 Efficiency (%) Efficiency (%) 10 20 40 60 80 70 60 50 40 30 20 100 90 80 70 60 50 40 30 20 10 20 40 60 80 100 Load Current (%) Load Current (%) Efficiency vs Output Load ( Single Output ) Efficiency vs Output Load ( Dual Output ) 100 80 Output Power (%) 100LFM 200LFM Output Power (%) 100 80 100LFM 200LFM 60 Natural convection 400LFM 60 Natural convection 400LFM 40 40 20 0 -25 20 0 50 60 70 80 ] 90 100 110 -25 〜 〜 50 60 70 80 ] 90 100 110 Ambient Temperature Ambient Temperature Derating Curve ( Single output ) Derating Curve ( Dual output ) REV:0 2005/04 MINMAX 4 S2D00R Series Test Configurations Input Reflected-Ripple Current Test Setup Input reflected-ripple current is measured with a inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0[ at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz. To Oscilloscope + Battery + Lin Current Probe +Vin +Out Load In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0[ at 100 KHz) capacitor of a 2.2uF for the 5V input devices, a 1.0uF for the 12V input devices and a 0.47uF for the 24V and 48V devices. + DC Power Source + Cin -Vin -Out +Vin DC / DC Converter +Out Load DC / DC Converter -Vin -Out Cin Peak-to-Peak Output Noise Measurement Test Use a Cout 0.33uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Vin Single Output DC / DC Converter -Vin -Out +Out Copper Strip Cout Scope Resistive Load Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 1.5uF capacitors at the output. + DC Power Source -Vin +Vin Single Output DC / DC Converter -Out +Out Cout Load +Vin Dual Output DC / DC Converter -Vin +Out Com. Copper Strip Cout Cout Scope Resistive Load Scope + DC Power Source - +Vin +Out Dual Output DC / DC Com. Converter Cout Load -Out -Vin -Out Design & Feature Considerations Maximum Capacitive Load The S2D00R series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. For optimum performance we recommend 220uF maximum capacitive load for dual outputs and 470uF capacitive load for single outputs. The maximum capacitance can be found in the data sheet. Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 90°C. The derating curves are determined from measurements obtained in an experimental apparatus. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. Position of air velocity probe and thermocouple 15mm / 0.6in 50mm / 2in Air Flow DUT 5 MINMAX REV:0 2005/04 S2D00R Series Mechanical Dimensions Top View ( 2.54 mm / 0.1 inch grids ) Connecting Pin Patterns Single Output 31.8 [1.25] Side 0.50 [0.020] 2.0 [0.08] 2.54 [0.100] 2.5 [0.10] 10.2 [0.40] 3.8 [0.15] Dual Output 12 Bottom 24 23 15 14 13 10 11 12 15.22 [0.600] Tolerance Millimeters X.X{0.25 X.XX{0.13 {0.05 Inches X.XX{0.01 X.XXX{0.005 {0.002 Pin Pin Connections Pin 1 2 10 11 12 13 14 15 23 24 Single Output +Vin +Vin NC NC -Vout +Vout NC NC -Vin -Vin NC: No Connection Dual Output +Vin +Vin Common Common NC -Vout NC +Vout -Vin -Vin 20.3 [0.80] Physical Characteristics 31.8*20.3*10.2 mm 1.25*0.80*0.40 inches Case Size : Case Material Weight Flammability : Non-Conductive Black Plastic : 12.1g : UL94V-0 The S2D00R converter is encapsulated in a low thermal resistance molding compound that has excellent resistance/electrical characteristics over a wide temperature range or in high humidity environments. The encapsulant and unit case are both rated to UL 94V-0 flammability specifications. Leads are tin plated for improved solderability. REV:0 2005/04 MINMAX 6
S2D11R 价格&库存

很抱歉,暂时无法提供与“S2D11R”相匹配的价格&库存,您可以联系我们找货

免费人工找货