0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
LK1AF-5V

LK1AF-5V

  • 厂商:

    MITSUBISHI

  • 封装:

  • 描述:

    LK1AF-5V - SLIM POWER RELAY WITH HIGH INRUSH CURRENT CAPABILITY - Mitsubishi Electric Semiconductor

  • 数据手册
  • 价格&库存
LK1AF-5V 数据手册
VDE SLIM POWER RELAY WITH HIGH INRUSH CURRENT CAPABILITY 2. High insulation resistance between contact and coil 1) Creepage distance and clearances between contact and coil: Min. 6 mm .236 inch (In compliance with IEC65) 2) Surge withstand voltage between contact and coil: 10,000 V or more 3. High noise immunity realized by the card separation structure between contact and coil 4. Popular terminal pitch in AV equipment field mm inch 16.5 .650 COM Coil N.O. 20 .787 1 .039 7.5 .295 1 .039 LK-RELAYS Creepage distance and clearances in compliance with IEC65 24.0 .945 11.0 .433 25.0 .984 Card Partition wall mm inch FEATURES 1. High inrush current capability 1) Operating load capability: inrush 100 A, steady 5 A 2) UL/CSA, TV-5 5. Space-saving slim type Base area: Width 11 × Length 24 mm Width .433 × Length .945 inch 6. Conforms to the various safety standards UL, CSA, VDE, TÜV, SEMKO, SEV, BSI approved SPECIFICATIONS Contact Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity Rating Max. switching power (resistive Max. switching voltage load) Max. switching current Expected Mechanical (at 180 cpm) life (min. Electrical (at 20 cpm) ope.) (at rated load) 1 Form A Max. 100 mΩ Silver alloy 5 A 277 V AC, 5 A 30 V DC 1,385 VA, 150 W 277 V AC, 30 V DC 5A (AC), 5 A (DC) 2 × 106 105 Characteristics Max. operating speed Initial insulation resistance*1 Initial Between open contacts breakdown Between contacts and coil voltage*2 Initial surge voltage between contact and coil*3 Operate time*4 (at nominal voltage) Release time (without diode)*4 (at nominal voltage) Temperature rise (at 70°C) 20 cpm Min. 1,000 MΩ (at 500 V DC) 1,000 Vrms for 1 min 4,000 Vrms for 1 min Min. 10,000 V Approx. 7 ms (at 20°C 68°F) Approx. 2 ms (at 20°C 68°F) Coil Nominal operating power Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section. *2 Detection current: 10mA *3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981 *4 Excluding contact bounce time. *5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs *6 Half-wave pulse of sine wave: 6 ms *7 Detection time: 10 µs *8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24). 530 mW Max. 35°C with nominal coil voltage at 5A contact carrying current (resistance method) Min. 200 m/s2 Functional*5 Shock resistance Destructive*6 Min. 1,000 m/s2 10 to 55 Hz Functional*7 at double amplitude of 1.5 mm Vibration resistance 10 to 55 Hz Destructive at double amplitude of 1.5 mm Conditions for operation, Ambient temp. –40 to +70°C -40 to +158°F transport and storage*8 Humidity 5 to 85%R.H. (Not freezing and condensAir pressure 86 to 106 kPa ing at low temperature) Unit weight Approx. 12 g .42 oz TYPICAL APPLICATIONS • AV equipment: TV’s, VTR’s, etc. • OA equipment • HA equipment ORDERING INFORMATION Ex. LK 1a F — 24V Coil voltage (DC) 5, 9, 12, 24 V Contact arrangement 1a: 1 Form A Protective construction F: Flux-resistant type UL/CSA, TÜV, SEMKO, TV-5 approved type is standard. (Note) Standard packing Carton: 100 pcs. Case: 500 pcs. 59 LK TYPES AND COIL DATA (at 20°C 68°F) Part No. LK1aF-5V LK1aF-9V LK1aF-12V LK1aF-24V Nominal voltage, V DC 5 9 12 24 Pick-up voltage V DC (max.) (Initial) 3.5 6.3 8.4 16.8 Drop-out voltage V DC (min.) (Initial) 0.5 0.9 1.2 2.4 Coil resistance, Ω (±10%) 47 153 272 1,087 Nominal operating current, mA (±10%) 106.4 58.8 44.2 22.1 Nominal operating power, mW 530 530 530 530 Max. allowable voltage, V DC (at 20°C 68°F) 6.5 11.7 15.6 31.2 mm inch DIMENSIONS 2-0.9 dia 2-.035 dia Max. 25 .984 0.5 .020 4 .157 0.4 .016 Max. 24 .945 16.5 .650 Max. 11 .433 20.0 .787 16.5 .650 PC board pattern (Copper-side view) 2-1.3 dia 2-.051 dia 7.5 .295 0.5 dia. 0.3 .020 dia. .012 1.65 .065 Tolerance ±0.1 ±.004 Schematic (Bottom view) 1 .039 7.5 .295 Dimension : Max. 1mm .039 inch: 1 to 3mm .039 to .118 inch: Min. 3mm .118 inch: General tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 20 .787 1 .039 REFERENCE DATA 1. Max. switching power (AC resistive load) 2. Coil temperature rise Sample: LK1aF-12V, 6 pcs. Point measured: coil inside Contact current: 5 A 10 Coil applied voltage, %V 50 40 30 20 10 0.1 0 Ambient temperature 70°C Ambient temperature 30°C 3. Ambient temperature characteristics Contact current: 5 A 200 180 160 140 120 100 Pick-up voltage 80 60 10 Cold start Allowable ambient temperatures against % coil voltages (max. inside the coil temperature set as 115°C 239°F) 1 Temperature rise, °C Contact current, A 0.1 1 10 100 Contact voltage, V 1000 80 100 110 120 90 Coil applied voltage, %V 20 30 40 50 60 70 Ambient temperature, °C 80 4. Life curve Operation frequency: 20 times/min. (ON/OFF = 1.5s: 1.5s) Ambient temperature: room temperature 100 5-1. Operate & release time (without diode) Sample: LK1aF-12V, 20 pcs. 5-2. Operate & release time (with diode) Sample: LK1aF-12V, 20 pcs. 15 Operate & release time, ms 15 Operate & release time, ms Operate time Release time Operate time Release time 250V AC resistive load Life, ×104 10 10 Max. Min. 10 5 Max. Min. Max. Min. 5 Max. Min. 1 0 1 2 3 4 5 0 70 Contact current, A 100 130 Coil applied voltage, %V 0 70 100 130 Coil applied voltage, %V 60 LK 6-1. Electrical life test (5 A 277 V AC, resistive load) Sample: LK1aF-12V, 6 pcs. Operation frequency: 20 times/min. (ON/OFF = 1.5s: 1.5s) Ambient temperature: 26°C 79°F Change of pick-up and drop-out voltage Ratio against the rated voltage, %V 100 Change of contact resistance 50 Contact resistance, mΩ 80 40 Circuit: Contact welding detection and Miscontacting detection circuit 60 Max. 40 Pick-up voltage Min. 30 20 Max. Min. 0 0 5 No. of operations, ×104 10 AC277V DC12V 20 Drop-out voltage 0 0 5 No. of operations, ×10 4 10 Max. Min. 10 Ratio against the rated voltage, % V 6-2. Electrical life test (UL lamp load test TV-5) Tested sample: LK1aF-12V, 6 pcs. • Overload test Load: 7.5 A 120 V AC (60 Hz), Inrush: 111 A Operation frequency: 10 times/min (ON: OFF = 1 s: 5 s) No. of operations: 50 ope. • Endurance test Load: 5A 120 V AC (60 Hz), Inrush: 78 A Operation frequency: 10 times/min (ON: OFF = 1 s: 5 s) No. of operations: 25,000 ope. Change of pick-up and drop-out voltage 100 Change of contact resistance 50 Contact resistance, mΩ 80 40 60 Pick-up voltage 40 Max. Min. 30 20 20 Drop-out voltage 0 0 No. of operations, ×104 Max. Min. 2.5 10 Max. Min. 0 0 No. of operations, ×104 2.5 NOTES 1. Cleaning This relay is not the sealed type, so it cannot be immersion cleaned. Be careful that flux does not overflow onto the PC board or penetrate inside the relay. 2. Soldering We recommend the following soldering conditions. 1) Automatic soldering * Preheating: 100°C 212°F, within 2 mins (PC board solder surface) * Soldering: 260°C 500°F, within 5 s 2) Hand soldering * Iron tip temperature: 280 to 300°C 536 to 571°F * Soldering iron: 30 to 60W * Soldering time: Within 3 s For Cautions for Use, see Relay Technical Information (Page 11 to 39). 61
LK1AF-5V 价格&库存

很抱歉,暂时无法提供与“LK1AF-5V”相匹配的价格&库存,您可以联系我们找货

免费人工找货