0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
M2V56D40ATP-75AL

M2V56D40ATP-75AL

  • 厂商:

    MITSUBISHI(三菱)

  • 封装:

  • 描述:

    M2V56D40ATP-75AL - 256M Double Data Rate Synchronous DRAM - Mitsubishi Electric Semiconductor

  • 数据手册
  • 价格&库存
M2V56D40ATP-75AL 数据手册
DDR SDRAM (Rev.1.0) Jul. '01 Preliminary M2S56D20/ 30/ 40AKT MITSUBISHI LSIs 256M Double Data Rate Synchronous DRAM PRELIMINARY Some of contents are subject to change without notice. DESCRIPTION M2S56D20AKT is a 4-bank x 16,777,216-word x 4-bit, M2S56D30AKT is a 4-bank x 8,388,608-word x 8-bit, M2S56D40AKT is a 4-bank x 4,194,304-word x 16-bit, double data rate synchronous DRAM, with SSTL_2 interface. All control and address signals are referenced to the rising edge of CLK. Input data is registered on both edges of data strobe, and output data and data strobe are referenced on both edges of CLK. The M2S56D20/30/40AKT achieves very high speed data rate up to 133MHz, and are suitable for main memory in computer systems. FEATURES - Vdd=Vddq=2.5V+0.2V - Double data rate architecture; two data transfers per clock cycle - Bidirectional, data strobe (DQS) is transmitted/received with data - Differential clock inputs (CLK and /CLK) - DLL aligns DQ and DQS transitions with CLK transitions edges of DQS - Commands entered on each positive CLK edge; - data and data mask referenced to both edges of DQS - 4 bank operation controlled by BA0, BA1 (Bank Address) - /CAS latency- 2.0/2.5 (programmable) - Burst length- 2/4/8 (programmable) - Burst type- sequential / interleave (programmable) - Auto precharge / All bank precharge controlled by A10 - 8192 refresh cycles /64ms (4 banks concurrent refresh) - Auto refresh and Self refresh - Row address A0-12 / Column address A0-9,11(x4)/ A0-9(x8)/ A0-8(x16) - SSTL_2 Interface - 400-mil, 66-pin Thin Small Outline Package (TSOP II) - JEDEC standard Operating Frequencies Speed Grade -75A -75 -10 Clock Rate CL=2 * 133MHz 100MHz 100MHz CL=2.5 * 133MHz 133MHz 125MHz * CL = CAS(Read) Latency MITSUBISHI ELECTRIC 1 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary M2S56D20/ 30/ 40AKT PIN CONFIGURATION(TOP VIEW) X4 X8 X 16 MITSUBISHI LSIs 256M Double Data Rate Synchronous DRAM VDD NC VDDQ NC DQ0 VSSQ NC NC VDDQ NC DQ1 VSSQ NC VDDQ NC NC VDD NC NC /WE /CAS /RAS /CS NC BA0 BA1 A10/AP A0 A1 A2 A3 VDD VDD DQ0 VDDQ NC DQ1 VSSQ NC DQ2 VDDQ NC DQ3 VSSQ NC VDDQ NC NC VDD NC NC /WE /CAS /RAS /CS NC BA0 BA1 A10/AP A0 A1 A2 A3 VDD VDD DQ0 VDDQ DQ1 DQ2 VSSQ DQ3 DQ4 VDDQ DQ5 DQ6 VSSQ DQ7 VDDQ LDQS NC VDD NC LDM /WE /CAS /RAS /CS NC BA0 BA1 A10/AP A0 A1 A2 A3 VDD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 VSS DQ15 VSSQ DQ14 DQ13 VDDQ DQ12 DQ11 VSSQ DQ10 DQ9 VDDQ DQ8 VSSQ UDQS NC VREF VSS UDM /CLK CLK CKE NC A12 A11 A9 A8 A7 A6 A5 A4 VSS VSS VSS DQ7 NC VSSQ VSSQ NC NC DQ6 DQ3 VDDQ VDDQ NC NC DQ5 NC VSSQ VSSQ NC NC DQ4 DQ2 VDDQ VDDQ NC NC VSSQ VSSQ DQS DQS NC NC VREF VREF VSS VSS DM DM /CLK /CLK CLK CLK CKE CKE NC NC A12 A12 A11 A11 A9 A9 A8 A8 A7 A7 A6 A6 A5 A5 A4 A4 VSS VSS 64pin STSOP PIN PITCH 0.4 mm CLK,/CLK CKE /CS /RAS /CAS /WE DQ0-7 DQS DM Vref : Master Clock : Clock Enable : Chip Select : Row Address Strobe : Column Address Strobe : Write Enable : Data I/O : Data Strobe : Write Mask : Reference Voltage A0-12 BA0,1 Vdd VddQ Vss VssQ : Address Input : Bank Address Input : Power Supply : Power Supply for Output : Ground : Ground for Output MITSUBISHI ELECTRIC 2 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary M2S56D20/ 30/ 40AKT MITSUBISHI LSIs 256M Double Data Rate Synchronous DRAM PIN FUNCTION SYMBOL TYPE DESCRIPTION CLK, /CLK Input Clock: CLK and /CLK are differential clock inputs. All address and control input signals are sampled on the crossing of the positive edge of CLK and negative edge of /CLK. Output (read) data is referenced to the crossings of CLK and /CLK (both directions of crossing). Clock Enable: CKE controls internal clock. When CKE is low, internal clock for the following cycle is ceased. CKE is also used to select auto / self refresh. After self refresh mode is started, CKE becomes asynchronous input. Self refresh is maintained as long as CKE is low. Chip Select: When /CS is high, any command means No Operation. Combination of /RAS, /CAS, /WE defines basic commands. A0-11 specify the Row / Column Address in conjunction with BA0,1. The Row Address is specified by A0-12. The Column Address is specified by A0-9,11(x4), A0-9(x8) and A0-8(x16). A10 is also used to indicate precharge option. When A10 is high at a read / write command, an auto precharge is performed. When A10 is high at a precharge command, all banks are precharged. Bank Address: BA0,1 specifies one of four banks to which a command is applied. BA0,1 must be set with ACT, PRE, READ, WRITE commands. Data Input/Output: Data bus CKE Input /CS /RAS, /CAS, /WE Input Input A0-12 Input BA0,1 DQ0-15(x16), DQ0-7(x8), DQ0-3(x4), Input Input / Output DQS Input / Output Data Strobe: Output with read data, input with write data. Edge-aligned with read data, centered in write data. Used to capture write data. For the x16, LDQS corresponds to the data on DQ0-DQ7; UDQS correspond to the data on DQ8-DQ15 Input Data Mask: DM is an input mask signal for write data. Input data is masked when DM is sampled HIGH along with that input data during a WRITE access. DM is sampled on both edges of DQS. Although DM pins are input only, the DM loading matches the DQ and DQS loading. For the x16, LDM corresponds to the data on DQ0-DQ7; UDM corresponds to the data on DQ8-DQ15. Power Supply for the memory array and peripheral circuitry. VddQ and VssQ are supplied to the Output Buffers only. SSTL_2 reference voltage. DM Input Vdd, Vss VddQ, VssQ Vref Power Supply Power Supply Input MITSUBISHI ELECTRIC 3 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M BLOCK DIAGRAM DLL DQ0 - 15 UDQS,LDQS I/O Buffer QS Buffer Memory Array Bank #0 Memory Array Bank #1 Memory Array Bank #2 Memory Array Bank #3 Mode Register Control Circuitry Address Buffer Clock Buffer A 0-12 BA0,1 C L K /C L K C K E /CS Control Signal Buffer /RAS /CAS / WE UDM, LDM Type Designation Code This rule is applied to only Synchronous DRAM family. M 2 S 56 D 3 0 A TP –75A Speed Grade 10: 125 MHz@CL=2.5,100MHz@CL=2.0 75: 133 MHz@CL=2.5,100MHz@CL=2.0 75 A: 133MHz@CL=2.5,133MHz@CL=2.0 Package Type TP: TSOP(II) Process Generation Function Reserved for Future Use n Organization 2 2: x4, 3: x8, 4: x16 D DR Synchronous DRAM Density 56: 256M bits Interface V:LVTTL, S:SSTL_3, _2 Memory Style (DRAM) Mitsubishi Main Designation MITSUBISHI ELECTRIC 4 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M BASIC FUNCTIONS The M2S56D20/30/40AKT provides basic functions, bank (row) activate, burst read / write, bank (row) precharge, and auto / self refresh. Each command is defined by control signals of /RAS, /CAS and /WE at CLK rising edge. In addition to 3 signals, /CS ,CKE and A10 are used as chip select, refresh option, and precharge option, respectively. To know the detailed definition of commands, please see the command truth table. /CLK CLK /CS /RAS /CAS /WE CKE A10 Chip Select : L=select, H=deselect Command Command Command Refresh Option @refresh command Precharge Option @precharge or read/write command define basic commands Activate (ACT) [/RAS =L, /CAS =/WE =H] ACT command activates a row in an idle bank indicated by BA. Read (READ) [/RAS =H, /CAS =L, /WE =H] READ command starts burst read from the active bank indicated by BA. First output data appears after /CAS latency. When A10 =H at this command, the bank is deactivated after the burst read (autoprecharge, R EADA ) Write (WRITE) [/RAS =H, /CAS =/WE =L] WRITE command starts burst write to the active bank indicated by BA. Total data length to be written is set by burst length. When A10 =H at this command, the bank is deactivated after the burst write (auto-precharge, W RITEA ) Precharge (PRE) [/RAS =L, /CAS =H, /WE =L] PRE command deactivates the active bank indicated by BA. This co mmand also terminates burst read /write operation. When A10 =H at this command, all banks are deactivated (precharge all, P REA ). A uto-Refresh (REFA) [/RAS =/CAS =L, /WE =CKE =H] REFA command starts auto-refresh cycle. Refresh address including bank address are generated internally. After this command, the banks are precharged automatically. MITSUBISHI ELECTRIC 5 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M COMMAND TRUTH TABLE COMMAND Deselect No Operation Row Address Entry & Bank Activate Single Bank Precharge Precharge All Banks Column Address Entry & Write Column Address Entry & Write with Auto-Precharge Column Address Entry & Read Column Address Entry & Read with Auto-Precharge Auto-Refresh Self-Refresh Entry Self-Refresh Exit Burst Terminate Mode Register Set REFA REFS REFSX TERM MRS H H L L H H H L H H H H L L H L L L L L X H H L L L X H H L H H X H L L X X X X X L X X X X X L X X X X X V 1 2 READA H H L H L H V H V READ H H L H L H V L V MNEMONIC DESEL NOP ACT PRE PREA WRITE WRITEA CKE n-1 H H H H H H H CKE n X X H H H H H /CS H L L L L L L /RAS X H L L L H H /CAS X H H H H L L /WE X H H L L L L BA0,1 X X V V X V V A10 /AP X X V L H L H A0-9, 11-12 X X V X X V V note H=High Level, L=Low Level, V=Valid, X=Don't Care, n=CLK cycle number NOTE: 1. Applies only to read bursts with autoprecharge disabled; this command is undefined (and should not be used) for read bursts with autoprecharge enabled, and for write bursts. 2. BA0-BA1 select either the Base or the Extended Mode Register (BA0 = 0, BA1 = 0 selects Mode Register;BA0=1 , BA1 = 0 selects Extended Mode Register; other combinations of BA0-BA1 are reserved; A0-A12 provide the op-code to be written to the selected Mode Register. MITSUBISHI ELECTRIC 6 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M FUNCTION TRUTH TABLE Current State IDLE / C S /RAS H L L L L L L L ROW ACTIVE H L L L L L L L L READ(AutoPrecharge Disabled) H L L L L L L L L X H H H L L L L X H H H H L L L L X H H H H L L L L / C A S / W E Address X H H L H H L L X H H L L H H L L X H H L L H H L L X H L X H L H L X H L H L H L H L X H L H L H L H L X X BA BA, CA, A10 BA, RA BA, A10 X Op-Code, ModeAdd X X BA BA, CA, A10 BA, CA, A10 BA, RA BA, A10 X Op-Code, ModeAdd X X BA BA, CA, A10 BA, CA, A10 BA, RA BA, A10 X Op-Code, ModeAdd Command DESEL NOP TERM READ / WRITE ACT PRE / PREA REFA MRS DESEL NOP TERM READ / READA WRITE / WRITEA ACT PRE / PREA REFA MRS DESEL NOP TERM READ / READA WRITE / WRITEA ACT PRE / PREA REFA MRS Action NOP NOP ILLEGAL ILLEGAL Bank Active, Latch RA NOP Auto-Refresh Mode Register Set NOP NOP NOP Begin Read, Latch CA, Determine Auto-Precharge Begin Write, Latch CA, Determine Auto-Precharge Bank Active / ILLEGAL Precharge / Precharge All ILLEGAL ILLEGAL NOP (Continue Burst to END) NOP (Continue Burst to END) Terminate Burst Terminate Burst, Latch CA, Begin New Read, Determine AutoPrecharge ILLEGAL Bank Active / ILLEGAL Terminate Burst, Precharge ILLEGAL ILLEGAL 2 3 2 4 5 5 2 2 Notes MITSUBISHI ELECTRIC 7 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M FUNCTION TRUTH TABLE (continued) Current State WRITE(AutoPrecharge Disabled) /CS /RAS /CAS /WE Address H L L L L L L L L H READ with Auto-Precharge L L L L L L L L WRITE with Auto-Precharge H L L L L L L L L X H H H H L L L L X H H H H L L L L X H H H H L L L L X H H L L H H L L X H H L L H H L L X H H L L H H L L X H L H L H L H L X H L H L H L H L X H L H L H L H L X X BA BA, CA, A10 BA, CA, A10 BA, RA BA, A10 X Command DESEL NOP TERM READ / READA WRITE / WRITEA ACT PRE / PREA REFA Action NOP (Continue Burst to END) NOP (Continue Burst to END) ILLEGAL Terminate Burst, Latch CA, Begin Read, Determine Auto-Precharge Terminate Burst, Latch CA, Begin Write, Determine Auto-Precharge Bank Active / ILLEGAL Terminate Burst, Precharge ILLEGAL ILLEGAL NOP (Continue Burst to END) NOP (Continue Burst to END) ILLEGAL ILLEGAL for Same Bank ILLEGAL for Same Bank Bank Active / ILLEGAL Precharge / ILLEGAL ILLEGAL ILLEGAL NOP (Continue Burst to END) NOP (Continue Burst to END) ILLEGAL ILLEGAL for Same Bank ILLEGAL for Same Bank Bank Active / ILLEGAL Precharge / ILLEGAL ILLEGAL ILLEGAL 7 7 2 2 6 6 2 2 3 3 2 Notes Op-Code, ModeMRS Add X DESEL X BA BA, CA, A10 BA, CA, A10 BA, RA BA, A10 X NOP TERM READ / READA WRITE / WRITEA ACT PRE / PREA REFA Op-Code, ModeMRS Add X X BA BA, CA, A10 BA, CA, A10 BA, RA BA, A10 X DESEL NOP TERM READ / READA WRITE / WRITEA ACT PRE / PREA REFA Op-Code, ModeMRS Add MITSUBISHI ELECTRIC 8 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M FUNCTION TRUTH TABLE (continued) Current State PRECHARGING /CS /RAS /CAS /WE Address H L L L L L L L ROW ACTIVATING H L L L L L L L WRITE RECOVERING H L L L L L L L X H H H L L L L X H H H L L L L X H H H L L L L X H H L H H L L X H H L H H L L X H H L H H L L X H L X H L H L X H L X H L H L X H L X H L H L X X BA BA, CA, A10 BA, RA BA, A10 X Command DESEL NOP TERM READ / WRITE ACT PRE / PREA REFA Action NOP (Idle after tRP) NOP (Idle after tRP) ILLEGAL ILLEGAL ILLEGAL NOP (Idle after tRP) ILLEGAL ILLEGAL NOP (Row Active after tRCD) NOP (Row Active after tRCD) ILLEGAL ILLEGAL ILLEGAL ILLEGAL ILLEGAL ILLEGAL NOP NOP ILLEGAL ILLEGAL ILLEGAL ILLEGAL ILLEGAL ILLEGAL 2 2 2 2 2 2 2 2 2 2 2 4 Notes Op-Code, ModeMRS Add X X BA BA, CA, A10 BA, RA BA, A10 X DESEL NOP TERM READ / WRITE ACT PRE / PREA REFA Op-Code, ModeMRS Add X DESEL X BA BA, CA, A10 BA, RA BA, A10 X NOP TERM READ / WRITE ACT PRE / PREA REFA Op-Code, ModeMRS Add MITSUBISHI ELECTRIC 9 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M FUNCTION TRUTH TABLE (continued) Current State REFRESHING / C S /RAS /CAS / W E Address H L L L L L L L MODE REGISTER SETTING H L L L L L L L X H H H L L L L X H H H L L L L X H H L H H L L X H H L H H L L X H L X H L H L X H L X H L H L X X BA BA, CA, A10 BA, RA BA, A10 X Command DESEL NOP TERM READ / WRITE ACT PRE / PREA REFA Action NOP (Idle after tRC) NOP (Idle after tRC) ILLEGAL ILLEGAL ILLEGAL ILLEGAL ILLEGAL ILLEGAL NOP (Row Active after tRSC) NOP (Row Active after tRSC) ILLEGAL ILLEGAL ILLEGAL ILLEGAL ILLEGAL ILLEGAL Notes Op-Code, ModeMRS Add X X BA BA, CA, A10 BA, RA BA, A10 X DESEL NOP TERM READ / WRITE ACT PRE / PREA REFA Op-Code, ModeMRS Add A BBREVIATIONS: H=High Level, L=Low Level, X=Don't Care BA=Bank Address, RA=Row Address, CA=Column Address, NOP=No Operation NOTES: 1. All entries assume that CKE was High during the preceding clock cycle and the current clock cycle. 2. ILLEGAL to bank in specified state; function may be legal in the bank indicated by BA, depending on the state of that bank. 3. Must satisfy bus contention, bus turn around, write recovery requirements. 4. NOP to bank precharging or in idle state. May precharge bank indicated by BA. 5. ILLEGAL if any bank is not idle. 6. Refer to Read with Auto -Precharge in page 24. 7. Refer to Write with Auto-Precharge in page 26. ILLEGAL = Device operation and/or data-integrity are not guaranteed. MITSUBISHI ELECTRIC 10 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M FUNCTION TRUTH TABLE for CKE Current State CKE n-1 H L L L L L L H L L H H H H H H H L H ANY STATE other than listed above L L H L X X X X X X X X X X Exit CLK Suspend at Next Cycle Maintain CLK Suspend 3 H L X X X X X Begin CLK Suspend at Next Cycle 3 CKE n X H H H H H L X H L H L L L L L L X H /CS X H L L L L X X X X X L H L L L L X X /RAS X X H H H L X X X X X L X H H H L X X /CAS X X H H L X X X X X X L X H H L X X X /WE X X H L X X X X X X X H X H L X X X X Address X X X X X X X X X X X X X X X X X X X INVALID Exit Self-Refresh (Idle after tRC) Exit Self-Refresh (Idle after tRC) ILLEGAL ILLEGAL ILLEGAL NOP (Maintain Self-Refresh) INVALID Exit Power Down to Idle NOP (Maintain Self-Refresh) Refer to Function Truth Table Enter Self-Refresh Enter Power Down Enter Power Down ILLEGAL ILLEGAL ILLEGAL Refer to Current State =Power Down Refer to Function Truth Table 2 2 2 2 2 2 2 2 Action Notes 1 1 1 1 1 1 1 SELFREFRESHING POWER DOWN ALL BANKS IDLE ABBREVIATIONS: H=High Level, L=Low Level, X=Don't Care NOTES: 1. CKE Low to High transition will re-enable CLK and other inputs asynchronously. A minimum setup time must be satisfied before any command other than EXIT. 2. Power-Down and Self-Refresh can be entered only from the All Banks Idle State. 3. Must be legal command. MITSUBISHI ELECTRIC 11 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M SIMPLIFIED STATE DIAGRAM POWER APPLIED POWER ON PRE PREA CHARGE ALL SELF REFRESH REFS MRS REFSX MODE REGISTER SET MRS IDLE REFA AUTO REFRESH CKEL CKEH Active Power Down CKEL CKEH ACT POWER DOWN ROW ACTIVE WRITE WRITE WRITEA READA READ READ READ BURST STOP WRITE READ TERM WRITEA READA READA WRITEA PRE PRE PRE READA PRE CHARGE Automatic Sequence Command Sequence MITSUBISHI ELECTRIC 12 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M POWER ON SEQUENCE Before starting normal operation, the following power on sequence is necessary to prevent a SDRAM from damaged or multifunctioning. 1. Apply VDD before or the same time as VDDQ 2. Apply VDDQ before or at the same time as VTT & Vref 3. Maintain stable condition for 200us after stable power and CLK, apply NOP or DSEL 4. Issue precharge command for all banks of the device 5. Issue EMRS 6. Issue MRS for the Mode Register and to reset the DLL 7. Issue 2 or more Auto Refresh commands 8. Maintain stable condition for 200 cycle After these sequence, the DDR SDRAM is idle state and ready for normal operation. MODE REGISTER Burst Length, Burst Type and /CAS Latency can be programmed by setting the mode register (MRS). The mode register stores these data until the next MRS command, which may be issued when both banks are in idle state. After tMRD from a MRS command, the DDR SDRAM is ready for new command. BA1 BA0 A12 A11 A10 A 9 0 0 0 0 0 0 A8 DR A7 0 A6 A5 A4 A3 BT A2 A1 BL A0 CLK /CLK /CS /RAS /CAS /WE BA0 BA1 LTMODE A11-A0 V CL 000 001 010 Latency Mode 011 100 101 110 111 0 1 /CAS Latency R R 2 R R R 2.5 R Burst Type NO YES Burst Length BL 000 001 010 011 100 101 110 111 0 1 BT=0 R 2 4 8 R R R R BT=1 R 2 4 8 R R R R Sequential Interleaved DLL Reset R: Reserved for Future Use MITSUBISHI ELECTRIC 13 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M EXTENDED MODE REGISTER DLL disable / enable mode can be programmed by setting the extended mode register (EMRS). The extended mode register stores these data until the next EMRS command, which may be issued when all banks are in idle state. After tMRD from a EMRS command, the DDR SDRAM is ready for new command. CLK /CLK / CS /RAS /CAS BA1 BA0 A12 A11 A10 A9 0 1 0 0 0 0 A8 0 A7 0 A6 0 A5 0 A4 0 A3 0 A2 0 A1 DS A0 DD /WE BA0 BA1 A11-A0 V DLL Disable 0 1 0 1 DLL Enable DLL Disable Normal Weak Drive Strength MITSUBISHI ELECTRIC 14 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M /CLK CLK Command Address DQS DQ CL= 2 BL= 4 /CAS Latency Q0 Q1 Q2 Q3 D0 D1 D2 D3 Read Y Write Y Burst Length Burst Length Initial Address A2 0 0 0 0 1 1 1 1 A1 0 0 1 1 0 0 1 1 0 0 1 1 A0 0 1 0 1 BL Sequential 0 1 2 3 8 4 5 6 7 0 1 4 2 3 0 2 1 1 2 3 4 5 6 7 0 1 2 3 0 1 0 2 3 4 5 6 7 0 1 2 3 0 1 3 4 5 6 7 0 1 2 3 0 1 2 4 5 6 7 0 1 2 3 5 6 7 0 1 2 3 4 Column Addressing Interleaved 6 7 0 1 2 3 4 5 7 0 1 2 3 4 5 6 0 1 2 3 4 5 6 7 0 1 2 3 0 1 1 0 3 2 5 4 7 6 1 0 3 2 1 0 2 3 0 1 6 7 4 5 2 3 0 1 3 2 1 0 7 6 5 4 3 2 1 0 4 5 6 7 0 1 2 3 5 4 7 6 1 0 3 2 6 7 4 5 2 3 0 1 7 6 5 4 3 2 1 0 0 1 0 1 0 1 0 1 0 1 MITSUBISHI ELECTRIC 15 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M ABSOLUTE MAXIMUM RATINGS Symbol Vdd VddQ VI VO IO Pd Topr Tstg Parameter Supply Voltage Supply Voltage for Output Input Voltage Output Voltage Output Current Power Dissipation Operating Temperature Storage Temperature Ta = 25 C o Conditions with respect to Vss with respect to VssQ with respect to Vss with respect to VssQ Ratings -0.5 ~ 3.7 -0.5 ~ 3.7 -0.5 ~ Vdd+0.5 -0.5 ~ VddQ+0.5 50 1000 0 ~ 70 -65 ~ 150 Unit V V V V mA mW o o C C DC OPERATING CONDITIONS (Ta=0 ~ 70 o C, unless otherwise noted) Symbol Vdd VddQ Vref VIH(DC) VIL(DC) VIN(DC) VTT Parameter Supply Voltage Supply Voltage for Output Input Reference Voltage High-Level Input Voltage Low-Level Input Voltage Input Voltage Level, CLK and /CLK I/O Termination Voltage Limits Min. 2.3 2.3 0.49*VddQ Vref + 0.15 -0.3 -0.3 0.36 Vref - 0.04 Typ. 2.5 2.5 0.50*VddQ Max. 2.7 2.7 0.51*VddQ VddQ+0.3 Vref - 0.15 VddQ + 0.3 VddQ + 0.6 Vref + 0.04 Unit V V V V V V V V Notes 5 VID(DC) Input Differential Voltage, CLK and /CLK 7 6 CAPACITANCE (Ta=0 ~ 70 o C, Vdd = VddQ = 2.5V + 0.2V, Vss = VssQ = 0V, unless otherwise noted) Symbol CI(A) CI(C) CI(K) CI/O Parameter Input Capacitance, address pin Input Capacitance, control pin Input Capacitance, CLK pin I/O Capacitance, I/O, DQS, DM pin Test Condition VI=1.25v f=100MHz VI=25mVrms Delta Unit Min. Max. Cap.(Max.) 2.0 2.0 2.0 4.0 3.0 3.0 3.0 5.0 0.25 0.50 0.50 pF pF pF pF Limits Notes 11 11 11 11 MITSUBISHI ELECTRIC 16 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M AVERAGE SUPPLY CURRENT from Vdd (Ta=0 ~ 70 o C, Vdd = VddQ = 2.5V + 0.2V, Vss = VssQ = 0V, Output Open, unless otherwise noted) Symbol Parameter/Test Conditions OPERATING CURRENT: One Bank; Active-Precharge; t RC = t RC MIN; t CK IDD0 = t CK MIN; DQ, DM and DQS inputs changing twice per clock cycle; address and control inputs changing once per clock cycle OPERATING CURRENT: One Bank; Active-Read-Precharge; IDD1 Burst = 2; t RC = t RC MIN; CL = 2.5; t CK = t CK MIN; IOUT= 0mA; Address and control inputs changing once per clock cycle PRECHARGE POWER-DOWN STANDBY CURRENT: All banks idle; powerdown mode; CKE < VIL (MAX); t CK = t CK MIN Organization x4 x8 x16 x4 x8 x16 x4/x8/x16 Limits(Max.) -75A 105 110 120 110 115 135 20 -75 105 110 120 110 115 135 20 -10 100 105 115 105 110 130 20 Unit Notes IDD2P IDLE STANDBY CURRENT: /CS > V IH (MIN); All banks idle; IDD2F CKE > V IH (MIN); t CK = t CK MIN; Address and other control inputs changing once per clock cycle IDD3P ACTIVE POWER-DOWN STANDBY CURRENT: One bank active; powerdown mode; CKE < V IL (MAX); t CK = t CK MIN ACTIVE STANDBY CURRENT: /CS > V IH (MIN); CKE > V IH (MIN); One IDD3N bank; Active-Precharge; t RC = t RAS MAX; t CK = t CK MIN; DQ,DM and DQS inputs changing twice per clock cycle; address and other control inputs changing once per clock cycle x4/x8/x16 40 40 40 x4/x8/x16 30 60 30 60 65 75 150 170 210 145 165 200 185 3 250 260 290 30 55 mA 60 70 140 160 200 135 155 180 175 3 230 240 280 20 20 20 x4/x8/x16 65 75 OPERATING CURRENT: Burst = 2; Reads; Continuous burst;One bank active; IDD4R Address and control inputs changing once per clock cycle;CL=2.5; t CK = t CK MIN; IOUT = 0 mA OPERATING CURRENT: Burst = 2; Writes; Continuous burst; One bank active; IDD4W Address and control inputs changing once per clock cycle; CL=2.5; t CK = t CK MIN;DQ, DM and DQS inputs changing twice per clock cycle IDD5 IDD6 AUTO REFRESH CURRENT: t RC = t RFC (MIN) SELF REFRESH CURRENT: CKE < 0 .2V x4 x8 x16 x4 x8 x16 x4/x8/x16 x4/x8/x16 x4 150 170 210 145 165 200 185 3 250 260 290 IDD7 OPERATING CURRENT-Four bank Operation: Four bank interleaving with BL=4 -Refer to the Notes 20 x8 x16 AC OPERATING CONDITIONS AND CHARACTERISTICS (Ta=0 ~ 70 o C, Vdd = VddQ = 2.5V + 0.2V, Vss = VssQ = 0V, Output Open, unless otherwise noted) Limits Min. Vref + 0.31 Vref - 0.31 0.7 -5 -2 -16.8 16.8 VddQ + 0.6 5 2 0.5*VddQ - 0.2 0.5*VddQ + 0.2 Max. Symbol Parameter / Test Conditions Unit V V V V µA µA Notes VIH(AC) High-Level Input Voltage (AC) VIL(AC) Low-Level Input Voltage (AC) VID(AC) Input Differential Voltage, CLK and /CLK VIX(AC) Input Crossing Point Voltage, CLK and /CLK IOZ II IOH IOL Off-state Output Current /Q floating Vo=0~VddQ Input Current / VIN=0 ~ VddQ Output High Current (VOUT = VTT+0.84V) Output High Current (VOUT = VTT-0.84V) 7 8 mA mA MITSUBISHI ELECTRIC 17 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M AC TIMING REQUIREMENTS (Ta=0 ~ 70 o C, Vdd = VddQ = 2.5V +0.2V, Vss = VssQ = 0V, unless otherwise noted) Symbol tAC AC Characteristics Parameter DQ Output Valid data delay time from CLK//CLK -75A Min. -0.75 -0.75 0.45 0.45 CL=2.5 tCK tDS tDH tDIPW tHZ tLZ tDQSQ tHP tQH tDQSS tDQSH tDQSL tDSS tDSH tMRD CLK cycle time CL=2 Input Setup time (DQ,DM) Input Hold time(DQ,DM) DQ and DM input pulse width (for each input) Data-out-high impedance time from CLK//CLK Data-out-low impedance time from CLK//CLK DQ Valid data delay time from DQS Clock half period Output DQS valid window Write command to first DQS latching transition DQS input High level width DQS input Low level width DQS falling edge to CLK setup time DQS falling edge hold time from CLK Mode Register Set command cycle time tCLmin or tCHmin tHP-0.75 0.75 0.35 0.35 0.2 0.2 15 0 0.4 0.25 0.9 0.9 0.4 0.9 0.6 1.1 0.6 1.25 7.5 0.5 0.5 1.75 -0.75 -0.75 0.75 0.75 0.5 tCLmin or tCHmin tHP-0.75 0.75 0.35 0.35 0.2 0.2 15 0 0.4 0.25 0.9 0.9 0.4 0.9 0.6 1.1 0.6 1.25 15 10 0.5 0.5 1.75 -0.75 -0.75 0.75 0.75 0.5 tCLmin or tCHmin tHP-1.0 0.75 0.35 0.35 0.2 0.2 15 0 0.4 0.25 1.1 1.1 0.4 0.9 0.6 1.1 0.6 1.25 15 10 0.6 0.6 2 -0.8 -0.8 0.8 0.8 0.6 15 ns ns ns ns ns ns ns ns ns tCK tCK tCK tCK tCK ns ns tCK tCK ns ns tCK tCK 19 19 16 15 14 14 7.5 Max 0.75 0.75 0.55 0.55 15 Min. -0.75 -0.75 0.45 0.45 7.5 -75 Max 0.75 0.75 0.55 0.55 15 Min. -0.8 -0.8 0.45 0.45 8 -10 Max 0.8 0.8 0.55 0.55 15 Unit ns ns tCK tCK ns Notes tDQSCK DQ Output Valid data delay time from CLK//CLK tCH tCL CLK High level width CLK Low level width tWPRES Write preamble setup time tWPST tWPRE tIS tIH tRPST tRPRE Write postamble Write preamble Input Setup time (address and control) Input Hold time (address and control) Read postamble Read preamble MITSUBISHI ELECTRIC 18 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M AC TIMING REQUIREMENTS(Continues) (Ta=0 ~ 70 o C, Vdd = VddQ = 2.5V +0.2V, Vss = VssQ = 0V, unless otherwise noted) -75A Min. 45 65 75 20 20 15 15 35 1 75 200 1 1 7.8 Max 120,000 Min. 45 65 75 20 20 15 15 35 1 75 200 1 1 7.8 -75 Max 120,000 Min. 50 70 80 20 20 15 15 35 1 80 200 1 1 7.8 -10 Max 120,000 Symbol tRAS tRC tRFC tRCD tRP tRRD tWR tDAL tWTR tXSNR tXSRD tXPNR tXPRD tREFI AC Characteristics Parameter Row Active time Row Cycle time(operation) Auto Ref. to Active/Auto Ref. command period Row to Column Delay Row Precharge time Act to Act Delay time Write Recovery time Auto Precharge write recovery + precharge time Internal Write to Read Command Delay Exit Self Ref. to non-Read command Exit Self Ref. to -Read command Exit Power down to command Exit Power down to -Read command Average Periodic Refresh interval Unit ns ns ns ns ns ns ns ns tCK ns tCK tCK tCK µs Notes 18 17 Output Load Condition DQS V TT = V REF 50 Ω VOUT Zo=50 Ω 30pF V REF V REF DQ V REF Output Timing Measurement Reference Point MITSUBISHI ELECTRIC 19 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M Notes 1. All voltages referenced to Vss. 2. Tests for AC timing, IDD, and electrical, AC and DC characteristics, may be conducted at nominal reference/supply voltage levels, but the related specifications and device operation are guaranteed for the full voltage range specified. 3. AC timing and IDD tests may use a VIL to VIH swing of up to 1.5V in the test environment, but input timing is still referenced to VREF (or to the crossing point for CK//CK), and parameter specifications are guaranteed for the specified AC input levels under normal use conditions. The minimum slew rate for the input signals is 1V/ns in the range between VIL(AC) and VIH(AC). 4. The AC and DC input level specifications are as defined in th e SSTL_2 Standard (i.e. the receiver will effectively switch as a result of the signal crossing the AC input level, and will remain in that state as long as the signal does not ring back above (below) the DC input LOW (HIGH) level. 5. VREF is expected to be equal to 0.5*VddQ of the transmitting device, and to track variations in the DC level of the same. Peak-to-peak noise on VREF may not exceed +2% of the DC value. 6. VTT is not applied directly to the device. VTT is a system su pply for signal termination resistors, is expected to be set equal to VREF, and must track variations in the DC level of VREF. 7. VID is the magnitude of the difference between the input level on CLK and the input level on /CLK. 8. The value of VIX is expected to equal 0.5*VddQ of the transmitting device and must track variations in the DC level of the same. 9. Enables on-chip refresh and address counters. 10. IDD specifications are tested after the device is properly initialized. 11. This parameter is sampled. VddQ = 2.5V+ 0.2V, Vdd = 2.5V + 0.2V , f = 100 MHz, Ta = 25 o C, VOUT(DC) = VddQ/2, VOUT(PEAK TO PEAK) = 25mV. DM inputs are grouped with I/O pins - reflecting the fact that they are matched in loading (to facilitate trace matching at the board level). 12. The CLK//CLK input reference level (for timing referenced to CLK//CLK) is the point at which CLK and /CLK cross; the input reference level for signals other than CLK//CLK, is VREF. 13. Inputs are not recognized as valid until VREF stabilizes. Exception: during the period before VREF stabilizes, CKE< 0.3VddQ is recognized as LOW. 14. t HZ and tLZ transitions occur in the same access time windows as valid data transitions. These parameters are not referenced to a specific voltage level, but specify when the device output is no longer driving (HZ), or begins driving (LZ). 15. The maximum limit for this parameter is not a device limit. The device will operate with a greater value for this parameter, but system performance (bus turnaround) will degrade accordingly. 16. The specific requirement is that DQS be valid (HIGH, LOW, or at some point on a valid transition) on or before this CLK edge. A valid transition is defined as monotonic, and meeting the input slew rate specifications of the device. When no writes were previously in progress on the bus, DQS will be transitioning from High-Z to logic LOW. If a previous write was in progress, DQS could be HIGH, LOW, or transitioning from HIGH to LOW at this time, depending on tDQSS. 17. A maximum of eight AUTO REFRESH commands can be posted to any given DDR SDRAM device. 18. tXPRD should be 200 tCLK in the condition of the unstable CLK operation during the power down mode. 19. For command/address and CK & /CK slew rate > 1.0V/ns. 20. IDD7 : Operating current:Four Bank For Bank are being interleaved with tRC(min),Burst Mode,Address and Control inputs on NOP edge are not changing.Iout = 0mA Timing patterns: tCK=min,tRRD=2*tCK,BL=4,tRCD=3*tCK,Read with Autoprecharge Read:A0 N A1 R0 A2 R1 N R3 A0 N A1 R0 – repeat the same timing with random address changing *100% of data changing at every burst Legend: A=Activate,R=Read,P=Precharge,N=NOP MITSUBISHI ELECTRIC 20 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M Read Operation tCK tCH tCL /CLK CLK Cmd & Add. tDQSCK tRPRE tRPST Valid Data VREF tIS tIH DQS tQH tDQSQ DQ tAC Write Operation / tDQSS=max. /CLK CLK DQS tDQSS tWPRES tDSS tWPST tWPRE tDQSL tDS tDQSH tDH DQ Write Operation / tDQSS=min. /CLK CLK DQS tDQSS tWPRES tWPRE tDQSL tDS tDQSH tDH tDSH tWPST DQ MITSUBISHI ELECTRIC 21 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M OPERATIONAL DESCRIPTION B ANK ACTIVATE The DDR SDRAM has four independent banks. Each bank is activate d by the ACT command with the bank addresses (BA0,1). A row is indicated by the row address A12-0. The minimum activation interval between one bank and the other bank is tRRD. PRECHARGE The PRE command deactivates the bank indicated by BA0,1. When multiple banks are active, the precharge all command (PREA,PRE+A10=H) is available to deactivate them at the same time. After tRP from the precharge, an ACT command to the same bank can be issued. Bank Activation and Precharge All (BL=8, CL=2) /CLK CLK 2 ACT command / tRCmin tRCmin Command ACT tRRD ACT READ tRAS PRE tRP ACT A0-9,11 Xa Xb tRCD Y BL/2 0 1 Xb A10 Xa Xb Xb BA0,1 00 01 00 01 DQS DQ Qa0 Qa1 Qa2 Qa3 Qa4 Qa5 Qa6 Qa7 Precharge all A precharge command can be issued at BL/2 from a read command without data loss. MITSUBISHI ELECTRIC 22 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M READ After tRCD from the bank activation, a READ command can be issued. 1st Output data is available after the /CAS Latency from the READ, followed by (BL-1) consecutive data when the Burst Length is BL. The start address is specified by A11,A9-A0(x4)/A9 -A0(x8)/A8-A0(x16), and the address sequence of burst data is defined by the Burst Type. A READ command may be applied to any active bank, so the row precharge time (tRP) can be hidden behind continuous output data by interleaving the multiple banks. When A10 is high at a READ command, the auto-precharge (READA) is performed. Any command(READ,WRITE,PRE,ACT) to the same bank is inhibited till the internal precharge is complete. The internal precharge starts at BL/2 after READA. The next ACT command can be issued after (BL/2+tRP) from the previous REA DA. Multi Bank Interleaving READ (BL=8, CL=2) /CLK CLK Command A0-9,11 A10 BA0,1 DQS DQ Qa0 Qa1 Qa2 Qa3 Qa4 Qa5 Qa6 Qa7 Qb0 Qb1 Qb2 Qb3 Qb4 Qb5 Qb7 Qb8 ACT tRCD Xa R E A D ACT READ PRE Y Xb Y Xa 0 Xb 0 0 00 00 10 10 00 Burst Length /CAS latency MITSUBISHI ELECTRIC 23 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M READ with Auto-Precharge (BL=8, CL=2,2.5) 0 /CLK CLK BL/2 + tRP 1 2 3 4 5 6 7 8 9 10 11 12 Command ACT tRCD Xa READA BL/2 Y tRP A0-9,11 A10 BA0,1 DQS CL=2 DQ DQS CL=2.5 DQ Xa 1 00 00 Qa0 Qa1 Qa2 Qa3 Qa4 Qa5 Qa6 Qa7 Qa0 Qa1 Qa2 Qa3 Qa4 Qa5 Qa6 Qa7 Internal Precharge Start Timing Asserted Command READ READA WRITE(CL=2) WRITE(CL=2.5) WRITEA(CL=2) WRITEA(CL=2.5) ACT PCG 3 Legal Legal Illegal Illegal Illegal Illegal Legal Legal 4 Legal Legal Illegal Illegal Illegal Illegal Legal Legal 5 Legal Legal Illegal Illegal Illegal Illegal Legal Legal For Different Bank 6 Legal Legal Illegal Illegal Illegal Illegal Legal Legal 7 Legal Legal Illegal Illegal Illegal Illegal Legal Legal 8 Legal Legal Legal Illegal Legal Illegal Legal Legal 9 Legal Legal Legal Legal Legal Legal Legal Legal 10 Legal Legal Legal Legal Legal Legal Legal Legal Operating description when new command asserted. MITSUBISHI ELECTRIC 24 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M WRITE After tRCD from the bank activation, a WRITE command can be issued. 1st input data is set from the WRITE command with data strobe input, following (BL-1) data are written into RAM, when the Burst Length is BL. The start address is specified by A11,A9-A0(x4)/A9-A0(x8)/A8-A0(x16), and the address sequence of burst data is defined by the Burst Type. A WRITE command may be applied to any active bank, so the row precharge time (tRP) can be hidden behind continuous input data by interleaving the multiple banks. From the last data to the PRE command, the write recovery time (tWRP) is required. When A10 is high at a WRITE command, the auto-precharge(WRITEA) is performed. Any command(READ,WRITE,PRE,ACT) to the same bank is inhibited till the internal precharge is complete. The next ACT command can be issued after tDAL from the last input data cycle. Multi Bank Interleaving WRITE (BL=8) /CLK CLK Command A0-9,11 ACT tRCD Xa D Ya Xb WRITE ACT tRCD D Yb WRITE PRE PRE A10 BA0,1 DQS DQ Xa Xa 00 0 Xb 0 0 0 00 10 10 00 10 Da0 Da1 Da2 Da3 Da4 Da5 Da6 Da7 Db0 Db1 Db2 Db3 Db4 Db5 Db6 Db7 MITSUBISHI ELECTRIC 25 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M WRITE with Auto -Precharge (BL=8) 0 /CLK CLK Command A0-9,11 A10 BA0,1 DQS DQ Da0 Da1 Da2 Da3 Da4 Da5 Da6 Da7 1 2 3 4 5 6 7 8 9 10 11 12 ACT tRC Xa D WRITEA tDAL Y ACT Xb Xa 1 Xb 00 00 00 Asserted Command READ READA WRITE WRITEA ACT PCG 3 Illegal Illegal Legal Legal Legal Legal 4 Illegal Illegal Legal Legal Legal Legal 5 Illegal Illegal Legal Legal Legal Legal For Different Bank 6 Illegal Illegal Legal Legal Legal Legal 7 Illegal Illegal Legal Legal Legal Legal 8 Legal Legal Legal Legal Legal Legal 9 Legal Legal Legal Legal Legal Legal 10 Legal Legal Legal Legal Legal Legal Operating description when new command asserted. MITSUBISHI ELECTRIC 26 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M BURST INTERRUPTION [Read Interrupted by Read] Burst read operation can be interrupted by new read of any bank. Random column access is allowed. READ to READ interval is minimum 1CLK. Read Interrupted by Read (BL=8, CL=2) /CLK CLK Command A0-9,11 A10 BA0,1 DQS DQ Qai0 Qai1 Qaj0 Qaj1 Qaj2 Qaj3 Qak0 Qak1 Qak2 Qak3 Qak4 Qak5 Qal0 Qal1 Qal2 Qal3 Qal4 Qal5 Qal6 Qal7 READ READ READ READ Yi Yj Yk Yl 0 0 0 0 00 00 10 01 [Read Interrupted by precharge] Burst read operation can be interrupted by precharge of the same bank. READ to PRE interval is minimum 1 CLK. A PRE command to output disable latency is equivalent to the /CAS Latency. As a result, READ to PRE interval determines valid data length to be output. The figure below shows examples of BL=8. Read Interrupted by Precharge (BL=8) /CLK CLK Command DQS DQ Command READ PRE Q0 Q1 Q2 Q3 Q4 Q5 READ PRE CL=2.5 DQS DQ Command DQS DQ Q0 Q1 Q0 Q1 Q2 Q3 READ PRE MITSUBISHI ELECTRIC 27 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M Read Interrupted by Precharge (BL=8) /CLK CLK Command DQS DQ Command READ Q0 Q1 Q2 Q3 Q4 Q5 READ PRE PRE CL=2.0 DQS DQ Command DQS DQ Q0 Q1 Q0 Q1 Q2 Q3 READ PRE MITSUBISHI ELECTRIC 28 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M [Read Interrupted by Burst Stop] Burst read operation can be interrupted by a burst stop command( TERM). READ to TERM interval is minimum 1 CLK. A TERM command to output disable latency is equivalent to the /CAS Latency. As a result, READ to TERM interval determines valid data length to be output. The figure below shows examples of BL=8. Read Interrupted by TERM (BL=8) /CLK CLK Command DQS DQ Command READ TERM Q0 Q1 Q2 Q3 Q4 Q5 READ TERM CL=2.5 DQS DQ Command DQS DQ Command DQS DQ Command READ Q0 Q1 Q2 Q3 Q4 Q5 Q0 Q1 Q0 Q1 Q2 Q3 R E A D TERM READ TERM TERM CL=2.0 DQS DQ Command DQS DQ Q0 Q1 Q0 Q1 Q2 Q3 R E A D TERM MITSUBISHI ELECTRIC 29 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M [Read Interrupted by Write with TERM] Read Interrupted by TERM (BL=8) /CLK CLK Command READ TERM WRITE CL=2.5 DQS DQ Command DQS DQ Q0 Q1 Q2 Q3 D0 D1 D2 D3 D4 D5 D6 D7 Q0 Q1 Q2 Q3 D0 D1 D2 D3 D4 D5 READ TERM WRITE CL=2.0 MITSUBISHI ELECTRIC 30 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M [Write interrupted by Write] Burst write operation can be interrupted by write of any bank. Random column access is allowed. WRITE to WRITE interval is minimum 1 CLK. Write Interrupted by Write (BL=8) /CLK CLK Command A0-9,11 WRITE WRITE WRITE WRITE Yi Yj Yk Yl A10 BA0,1 0 0 0 0 00 00 10 00 DQS DQ Dai0 Dai1 Daj0 Daj1 Daj2 Daj3 Dak0 Dak1 Dak2 Dak3 Dak4 Dak5 Dal0 Dal1 Dal2 Dal3 Dal4 Dal5 Dal6 Dal7 [Write interrupted by Read] Burst write operation can be interrupted by read of the same or the other bank. Random column access is allowed. Internal WRITE to READ command interval(tWTR) is minimum 1 CLK. The input data on DQ at the interrupting READ cycle is "don't care". tWTR is referenced from the first positive edge after the last data input. Write Interrupted by Read (BL=8, CL=2.5) /CLK CLK Command A0-9,11 A10 BA0,1 DM tWTR QS DQ Dai0 Dai1 Qaj0 Qaj1 Qaj2 Qaj3 Qaj4 Qaj5 Qaj6 Qaj7 WRITE READ Yi Yj 0 0 00 00 MITSUBISHI ELECTRIC 31 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M [Write interrupted by Precharge] Burst write operation can be interrupted by precharge of the same or all bank. Random column access is allowed. tWR is referenced from the first positive CLK edge after the last data input. Write Interrupted by Precharge (BL=8, CL=2.5) /CLK CLK Command A0-9,11 A10 BA0,1 DM QS DQ WRITE PRE Yi 0 00 00 tWR Dai0 Dai1 MITSUBISHI ELECTRIC 32 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M [Initialize and Mode Register sets] Initialize and MRS /CLK CLK CKE Command A0-9,11 A10 BA0,1 DQS DQ tMRD Extended Mode Register Set 1 NOP PRE EMRS MRS PRE AR AR MRS ACT Code Code Xa Code Code 1 Code Xa 10 00 00 Xa tMRD Reset DLL tRP tRFC tRFC tMRD Mode Register Set, [AUTO REFRESH] Single cycle of auto-refresh is initiated with a REFA(/CS=/RAS=/CAS=L,/WE=CKE=H) command. The refresh address is generated internally. 8192 REFA cycles within 64ms refresh 256Mbits memory cells. The auto-refresh is performed on 4 banks concurrently. Before performing an auto refresh, all banks must be in the idle state. Auto-refresh to auto-refresh interval is minimum tRFC . Any command must not be supplied to the device before tRFC from the REFA command. Auto-Refresh /CLK CLK /CS /RAS /CAS /WE CKE A0-11 BA0,1 tRFC NOP or DESELECT Auto Refresh on All Banks Auto Refresh on All Banks MITSUBISHI ELECTRIC 33 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M [SELF REFRESH] Self -refresh mode is entered by issuing a REFS command (/CS=/RAS=/CAS=L,/WE=H,CKE=L). Once the self-refresh is initiated, it is maintained as long as CKE is kept low. During the selfrefresh mode, CKE is asynchronous and the only enable input, all other inputs including CLK are disabled and ignored, so that power consumption due to synchronous inputs is saved. To exit the self-refresh, supplying stable CLK inputs, asserting DESEL or NOP command and then asserting CKE for longer than tXSNR/tXSRD. S elf-Refresh /CLK CLK /CS /RAS /CAS /WE CKE A0-11 BA0,1 X X tXSNR Self Refresh Exit tXSRD Y Y MITSUBISHI ELECTRIC 34 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M [Power DOWN] The purpose of CLK suspend is power down. CKE is synchronous inp ut except during the selfrefresh mode. A command at cycle is ignored. From CKE=H to normal function, DLL recovery time is NOT required in the condition of the stable CLK operation during the power down mode. Power Down by CKE /CLK CLK CKE Standby Power Down Command PRE NOP NOP Valid tXPNR/tXPRD CKE Active Power Down Command ACT NOP NOP Valid [ DM CONTROL] DM is defined as the data mask for writes. During writes,DM masks input data word by word. DM to write mask latency is 0. DM Function(BL=8,CL=2) /CLK CLK Command DM WRITE READ Don't Care DQS DQ D0 D1 D3 D4 D5 D6 D7 Q0 Q1 Q2 Q3 Q4 Q5 Q6 masked by DM=H MITSUBISHI ELECTRIC 35 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M Keep safety first in your circuit designs! Mitsubishi Electric Corporation puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of non-flammable material or (iii) prevention against any malfunction or mishap. Notes regarding these materials These materials are intended as a reference to assist our customers in the selection of the Mitsubishi semiconductor product best suited to the customer’s application; they do not convey any license under any intellectual property rights, or any other rights, belonging to Mitsubishi Electric Corporation or a third party. Mitsubishi Electric Corporation assumes no responsibility for any damage, or infringement of any third-party’s rights, originating in the use of any product data, diagrams, charts, programs, algorithms, or circuit application examples contained in these materials. All information contained in these materials, including product data, diagrams, charts, programs and algorithms represents information on products at the time of publication of these materials, and are subject to change by Mitsubishi Electric Corporation without notice due to product improvements or other reasons. It is therefore recommended that customers contact Mitsubishi Electric Corporation or an authorized Mitsubishi Semiconductor product distributor for the latest product information before purchasing a product listed herein. The information described here may contain technical inaccuracies or typographical errors. Mitsubishi Electric Corporation assumes no responsibility for any damage, liability, or other loss rising from these inaccuracies or errors. Please also pay attention to information published by Mitsubishi Electric Corporation by various means, including the Mitsubishi Semiconductor home page (http://www.mitsubishichips.com). When using any or all of the information contained in these materials, including product data, diagrams, charts, programs, and algorithms, please be sure to evaluate all information as a total system before making a final decision on the applicability of the information and products. Mitsubishi Electric Corporation assumes no responsibility for any damage, liability or other loss resulting from the information contained herein. Mitsubishi Electric Corporation semiconductors are not designed or manufactured for use in a device or system that is used under circumstances in which human life is potentially at stake. Please contact Mitsubishi Electric Corporation or an authorized Mitsubishi Semiconductor product distributor when considering the use of a product contained herein for any specific purposes, such as apparatus or systems for transportation, vehicular, medical, aerospace, nuclear, or undersea repeater use. The prior written approval of Mitsubishi Electric Corporation is necessary to reprint or reproduce in whole or in part these materials. If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a license from the Japanese government and cannot be imported into a country other than the approved destination. Any diversion or reexport contrary to the export control laws and regulations of Japan and/or the country of destination is prohibited. Please contact Mitsubishi Electric Corporation or an authorized Mitsubishi Semiconductor product distributor for further details on these materials or the products contained therein. MITSUBISHI ELECTRIC 36 DDR SDRAM (Rev.1.0) Jul. '01 Preliminary MITSUBISHI LSIs M2S56D20/ 30/ 40AKT 256 M D o u b l e D a t a R a t e S y n c h r o n o u s D R A M Revision History Rev. 1.0 Date Jul. ’01 -New registration (Jul. ‘01) Description MITSUBISHI ELECTRIC 37
M2V56D40ATP-75AL 价格&库存

很抱歉,暂时无法提供与“M2V56D40ATP-75AL”相匹配的价格&库存,您可以联系我们找货

免费人工找货