RA60H1317M1A
RoHS Compliance ,136-174MHz 60W 12.5V, 2 Stage Amp. For MOBILE RADIO DESCRIPTION The RA60H1317M1A is a 60-watt RF MOSFET Amplifier Module for 12.5-volt mobile radios that operate in the 136- to 174-MHz range. The battery can be connected directly to the drain of the enhancement-mode MOSFET transistors. The output power and drain current increase as the gate voltage increases. With a gate voltage around 4V (minimum), output power and drain current increases substantially. The nominal output power becomes available at 4.5V (typical) and 5V (maximum). At VGG=5V, the typical gate current is 1 mA. This module is designed for non-linear FM modulation, but may also be used for linear modulation by setting the drain quiescent current with the gate voltage and controlling the output power with the input power. FEATURES • Enhancement-Mode MOSFET Transistors (IDD0 @ VDD=12.5V, VGG=0V) • Pout>60W, T>45% @ VDD=12.5V, VGG=5V, Pin=50mW • Broadband Frequency Range: 136-174MHz • Low-Power Control Current IGG=1mA (typ) at VGG=5V • Module Size: 67 x 19.4 x 9.9 mm RoHS COMPLIANCE • RA60H1317M1A-201 is a RoHS compliant product. • RoHS compliance is indicate by the letter “G” after the Lot Marking. • This product include the lead in the Glass of electronic parts and the lead in electronic Ceramic parts. However ,it is applicable to the following exceptions of RoHS Directions. 1.Lead in the Glass of a cathode-ray tube, electronic parts, and fluorescent tubes. 2.Lead in electronic Ceramic parts. BLOCK DIAGRAM
2 3
1
4 5
1 2 3 4 5
RF Input (Pin) Gate Voltage (VGG), Power Control Drain Voltage (VDD), Battery RF Output (Pout) RF Ground (FIN)
PACKAGE CODE: H2M
ORDERING INFORMATION: ORDER NUMBER RA60H1317M1A-201 SUPPLY FORM Antistatic tray, 10 modules/tray
Publication Date :Apr.2011 1
<
Silicon RF Power Modules >
RA60H1317M1A
RoHS Compliance ,136-174MHz 60W 12.5V, 2 Stage Amp. For MOBILE RADIO MAXIMUM RATINGS (Tcase=+25°C, unless otherwise specified) SYMBOL PARAMETER VDD VGG Pin Pout Drain Voltage Gate Voltage Input Power f=136-174MHz, Output Power ZG=ZL=50 80 -30 to +100 -40 to +110 W °C °C Tcase(OP) Operation Case Temperature Range Tstg Storage Temperature Range CONDITIONS VGG
RA60H1317M1A
RoHS Compliance ,136-174MHz 60W 12.5V, 2 Stage Amp. For MOBILE RADIO TYPICAL PERFORMANCE (Tcase=+25°C, ZG=ZL=50, unless otherwise specified)
OUTPUT POWER and DRAIN CURRENT versus GATE VOLTAGE 100 90 80
O utput Power Pout ( W)
OUTPUT POWER and DRAIN CURRENT versus GATE VOLTAGE 20 100 90 80
O utput Power Pout ( W) Dr ain Cur r ent IDD ( A)
20 f=155MHz V DD=12.5V Pin=50mW Pout 18 16
Dr ain Cur r ent IDD ( A)
f=136MHz V DD=12.5V Pin=50mW
18 Pout 16 14 12 I DD 10 8 6 4 2 0
70 60 50 40 30 20 10 0 2.0
70 60 50 40 30 20 10 0 2.0 I DD
14 12 10 8 6 4 2 0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Gate Voltage V GG (V)
2.5
3.0
3.5
4.0
4.5
5.0
5.5
Gate Voltage V GG (V)
OUTPUT POWER and DRAIN CURRENT versus GATE VOLTAGE 100 90 80
O utput Power Pout ( W)
20 f=174MHz V DD=12.5V Pin=50mW 18 Pout 16
Dr ain Cur r ent IDD ( A)
70 60 50 40 30 20 10 0 2.0 I DD
14 12 10 8 6 4 2 0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Gate Voltage V GG (V)
Publication Date :Apr.2011 5
<
Silicon RF Power Modules >
RA60H1317M1A
RoHS Compliance ,136-174MHz 60W 12.5V, 2 Stage Amp. For MOBILE RADIO OUTLINE DRAWING (mm)
67±1 60±1 2-R2±0.5 49.8±1
(3.26)
19.4±1
10.7±1
①②
③
④
15±1
12.5±1 17±1 44±1 56±1
3.1+0.6/-0.4
0.6±0.2
7.3±0.5
4±0.5 (2.6)
1 2 3 4 5
INPUT TERMINAL (Pin ) GATE BIAS DC SUPPLY TERMINAL (VGG) DRAIN BIAS DC SUPPLY TERMINAL (VDD) OUTPUT TERMINAL (Pout) Fin (GND)
Publication Date :Apr.2011 6
(9.9)
18±1
<
Silicon RF Power Modules >
RA60H1317M1A
RoHS Compliance ,136-174MHz 60W 12.5V, 2 Stage Amp. For MOBILE RADIO TEST BLOCK DIAGRAM
Power Meter 1 2
DUT
3 4
5
Spectrum Analyzer
Signal Generator
Attenuator
Preamplifier
Attenuator
Directional Coupler
ZG=50
ZL=50
Directional Coupler
Attenuator
Power Meter
C1
C2
+ DC Power Supply VGG C1, C2: 4700pF, 22uF in parallel
+ DC Power Supply VDD
1 2 3 4 5
INPUT TERMINAL (Pin ) GATE BIAS DC SUPPLY TERMINAL (VGG) DRAIN BIAS DC SUPPLY TERMINAL (VDD) OUTPUT TERMINAL (Pout) Fin (GND)
EQUIVALENT CIRCUIT
②
③
①
④ ⑤
Publication Date :Apr.2011 7
<
Silicon RF Power Modules >
RA60H1317M1A
RoHS Compliance ,136-174MHz 60W 12.5V, 2 Stage Amp. For MOBILE RADIO RECOMMENDATIONS and APPLICATION INFORMATION: Construction: This module consists of a glass-epoxy substrate soldered onto a copper flange. For mechanical protection, a metal cap is attached (which makes the improvement of RF radiation easy). The MOSFET transistor chips are die bonded onto metal, wire bonded to the substrate, and coated with resin. Lines on the substrate (eventually inductors), chip capacitors, and resistors form the bias and matching circuits. Wire leads soldered onto the glass-epoxy substrate provide the DC and RF connection. Following conditions must be avoided: a) Bending forces on the glass-epoxy substrate (for example, by driving screws or from fast thermal changes) b) Mechanical stress on the wire leads (for example, by first soldering then driving screws or by thermal expansion) c) Defluxing solvents reacting with the resin coating on the MOSFET chips (for example, Trichloroethylene) d) ESD, surge, overvoltage in combination with load VSWR, and oscillation ESD: This MOSFET module is sensitive to ESD voltages down to 1000V. Appropriate ESD precautions are required. Mounting: A thermal compound between module and heat sink is recommended for low thermal contact resistance. The module must first be screwed to the heat sink, then the leads can be soldered to the printed circuit board. M3 screws are recommended with a tightening torque of 4.0 to 6.0 kgf-cm.
Soldering and Defluxing: This module is designed for manual soldering. The leads must be soldered after the module is screwed onto the heat sink. The temperature of the lead (terminal) soldering should be lower than 350°C and shorter than 3 second. Ethyl Alcohol is recommend for removing flux. Trichloroethylene solvents must not be used (they may cause bubbles in the coating of the transistor chips which can lift off the bond wires). Thermal Design of the Heat Sink: At Pout=60W, VDD=12.5V and Pin=50mW each stage transistor operating conditions are: Stage 1 2
st
Pin (W) 0.05 5.0
Pout (W) 5.0 60.0
Rth(ch-case) (°C/W) 2.1 0.5
IDD @ T=45% (A) 0.8
VDD (V) 12.5
nd
9.8
The channel temperatures of each stage transistor Tch = Tcase + (VDD x IDD - Pout + Pin) x Rth(ch-case) are: Tch1 = Tcase + (12.5V x 0.8A - 5.0W + 0.05W) x 2.1°C/W = Tcase + 10.6 °C Tch2 = Tcase + (12.5V x 9.8A - 60W + 5.0W) x 0.5°C/W = Tcase + 33.8 °C For long-term reliability, it is best to keep the module case temperature (Tcase) below 90°C. For an ambient temperature Tair=60°C and Pout=60W, the required thermal resistance Rth (case-air) = ( Tcase - Tair) / ( (Pout / T ) Pout + Pin ) of the heat sink, including the contact resistance, is: Rth(case-air) = (90°C - 60°C) / (60W/45% – 60W + 0.05W) = 0.41 °C/W When mounting the module with the thermal resistance of 0.41 °C/W, the channel temperature of each stage transistor is: Tch1 = Tair + 40.6 °C Tch2 = Tair + 63.8 °C The 175°C maximum rating for the channel temperature ensures application under derated conditions.
Publication Date :Apr.2011 8
<
Silicon RF Power Modules >
RA60H1317M1A
RoHS Compliance ,136-174MHz 60W 12.5V, 2 Stage Amp. For MOBILE RADIO Output Power Control: By the gate voltage (VGG). Around VGG=4V, the output power and drain current increases substantially. Around VGG=4.5V (typical) to VGG=5V (maximum), the nominal output power becomes available. Oscillation: To test RF characteristics, this module is put on a fixture with two bias decoupling capacitors each on gate and drain, a 4.700 pF chip capacitor, located close to the module, and a 22 µF (or more) electrolytic capacitor. When an amplifier circuit around this module shows oscillation, the following may be checked: a) Do the bias decoupling capacitors have a low inductance pass to the case of the module? b) Is the load impedance ZL=50? c) Is the source impedance ZG=50? ATTENTION: 1.High Temperature; This product might have a heat generation while operation,Please take notice that have a possibility to receive a burn to touch the operating product directly or touch the product until cold after switch off. At the near the product,do not place the combustible material that have possibilities to arise the fire. 2. Generation of High Frequency Power; This product generate a high frequency power. Please take notice that do not leakage the unnecessary electric wave and use this products without cause damage for human and property per normal operation. 3. Before use; Before use the product,Please design the equipment in consideration of the risk for human and electric wave obstacle for equipment. PRECAUTION FOR THE USE OF MITSUBISHI SILICON RF POWER AMPLIFIER DEVICES: 1.The specifications of mention are not guarantee values in this data sheet. Please confirm additional details regarding operation of these products from the formal specification sheet. For copies of the formal specification sheets, please contact one of our sales offices. 2.RA series products (RF power amplifier modules) and RD series products (RF power transistors) are designed for consumer mobile communication terminals and were not specifically designed for use in other applications. In particular, while these products are highly reliable for their designed purpose, they are not manufactured under a quality assurance testing protocol that is sufficient to guarantee the level of reliability typically deemed necessary for critical communications elements. In the application, which is base station applications and fixed station applications that operate with long term continuous transmission and a higher on-off frequency during transmitting, please consider the derating, the redundancy system, appropriate setting of the maintain period and others as needed. For the reliability report which is described about predicted operating life time of Mitsubishi Silicon RF Products , please contact Mitsubishi Electric Corporation or an authorized Mitsubishi Semiconductor product distributor. 3.RA series products and RD series Products use MOSFET semiconductor technology. They are sensitive to ESD voltage therefore appropriate ESD precautions are required. 4.In order to maximize reliability of the equipment, it is better to keep the devices temperature low. It is recommended to utilize a sufficient sized heat-sink in conjunction with other cooling methods as needed (fan, etc.) to keep the case temperature for RA series products lower than 60deg/C under standard conditions, and less than 90deg/C under extreme conditions. 5.RA series products are designed to operate into a nominal load impedance of 50. Under the condition of operating into a severe high load VSWR approaching an open or short, an over load condition could occur. In the worst case there is risk for burn out of the transistors and burning of other parts including the substrate in the module. 6.The formal specification includes a guarantee against parasitic oscillation under a specified maximum load mismatch condition. The inspection for parasitic oscillation is performed on a sample basis on our manufacturing line. It is recommended that verification of no parasitic oscillation be performed at the completed equipment level also. 7.For specific precautions regarding assembly of these products into the equipment, please refer to the supplementary items in the specification sheet. 8.Warranty for the product is void if the products protective cap (lid) is removed or if the product is modified in any way from it’s original form. 9.For additional “Safety first” in your circuit design and notes regarding the materials, please refer the last page of this data sheet. 10. Please refer to the additional precautions in the formal specification sheet. Publication Date :Apr.2011 9
<
Silicon RF Power Modules >
RA60H1317M1A
RoHS Compliance ,136-174MHz 60W 12.5V, 2 Stage Amp. For MOBILE RADIO
Keep safety first in your circuit designs!
Mitsubishi Electric Corporation puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of non-flammable material or (iii) prevention against any malfunction or mishap.
Notes regarding these materials
•These materials are intended as a reference to assist our customers in the selection of the Mitsubishi semiconductor product best suited to the customer’s application; they do not convey any license under any intellectual property rights, or any other rights, belonging to Mitsubishi Electric Corporation or a third party. •Mitsubishi Electric Corporation assumes no responsibility for any damage, or infringement of any third-party’s rights, originating in the use of any product data, diagrams, charts, programs, algorithms, or circuit application examples contained in these materials. •All information contained in these materials, including product data, diagrams, charts, programs and algorithms represents information on products at the time of publication of these material s, and are subject to change by Mitsubishi Electric Corporation without notice due to product improvements or other reasons. It is therefore recommended that customers contact Mitsubishi Electric Corporation or an authorized Mitsubishi Semiconductor product distributor for the latest product information before purchasing a product listed herein. The information described here may contain technical inaccuracies or typographical errors. Mitsubishi Electric Corporation assumes no responsibility for any damage, liability, or other loss rising from these inaccuracies or errors. Please also pay attention to information published by Mitsubishi Electric Corporation by various means, including the Mitsubishi Semiconductor home page (http://www.MitsubishiElectric.com/). •When using any or all of the information contained in these material s, including product data, diagrams, charts, programs, and algorithms, please be sure to evaluate all information as a total system before making a final decision on the applicability of the information and products. Mitsubishi Electric Corporation assumes no responsibility for any damage, liability or other loss resulting from the information contained herein. •Mitsubishi Electric Corporation semiconductors are not designed or manufactured for use in a device or system that is used under circumstances in which human life is potentially at stake. Please contact Mitsubishi Electric Corporation or an authorized Mitsubishi Semiconductor product distributor when considering the use of a product contained herein for any specific purposes, such as apparatus or systems for transportation, vehicular, medical, aerospace, nuclear, or undersea repeater use. •The prior written approval of Mitsubishi Electric Corporation is necessary to reprint or reproduce in wh ole or in part these materials. •If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a license from the Japanese government and cannot be imported into a country other than the approved destination. Any diversion or re-export contrary to the export control laws and regulations of Japan and/or the country of destination is prohibited. •Please contact Mitsubishi Electric Corporation or an authorized Mitsubishi Semiconductor product distributor for further details on these materials or the products contained therein.
© 2011 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
Publication Date :Apr.2011 10