MITSUBISHI HIGH VOLTAGE DIODE MODULE
RM600DY-66S
High Voltage Diode Module HIGH POWER SWITCHING USE INSULATED TYPE
RM600DY-66S
● IF ................................................................... 600A ● VRRM ...................................................... 3300V ● Insulated Type ● 2-element in a Pack ● Copper Baseplate
APPLICATION Traction drives, High Reliability Converters / Inverters, DC choppers
OUTLINE DRAWING & CIRCUIT DIAGRAM
Dimensions in mm
130 114 57 ± 0.25 57 ± 0.25 4-M8 NUTS (E) A1 K1 (C)
20
(E) A2
K2 (C)
K1
124 ± 0.25 140
C
K2
C
A1
E
A2
E
C
E
G
6-φ7 MOUNTING HOLES
40
CIRCUIT DIAGRAM
61.5 18
15
38
High Voltage Diode Module
5
LABEL
30
May 2009 1
MITSUBISHI HIGH VOLTAGE DIODE MODULE
RM600DY-66S
High Voltage Diode Module HIGH POWER SWITCHING USE INSULATED TYPE
MAXIMUM RATINGS
Symbol VRRM VRSM VR(DC) IF IFSM I 2t Viso Tj Top Tstg Item Repetitive peak reverse voltage Non-repetitive peak reverse voltage Reverse DC voltage DC forward current Surge forward current Current-squared, time integration Isolation voltage Junction temperature Operating temperature Storage temperature Conditions Tj = 25 °C Tj = 25 °C Tj = 25 °C TC = 25 °C Tj = 25 °C start, tw = 8.3 ms Half sign wave Tj = 25 °C start, tw = 8.3 ms Half sign wave Charged part to the baseplate RMS sinusoidal, 60Hz 1min. — — — Ratings 3300 3300 2200 600 4800 96 6000 –40 ~ +150 –40 ~ +125 –40 ~ +125 Unit V V V A A kA2s V °C °C °C
ELECTRICAL CHARACTERISTICS
Symbol IRRM VFM trr Irr Qrr Erec Item Repetitive reverse current Forward voltage (Note 1) VRM = VRRM IF = 600 A VR = 1650 V, IF = 600 A di/dt = –1200 A/µs Ls=200nH, Tj = 125 °C Conditions Tj = 25 °C Tj = 125 °C Tj = 25 °C Tj = 125 °C Min — — — — — — — — Limits Typ — — 3.75 3.75 0.75 450 300 0.23 Max 4.0 15 4.55 — — — — — Unit mA V µs A µC J/P
Reverse recovery time Reverse recovery current Reverse recovery charge Reverse recovery energy (Note 2)
Note 1. It doesn't include the voltage drop by internal lead resistance. 2. Erec is the integral of 0.1VR x 0.1Irr x dt.
High Voltage Diode Module
May 2009 2
MITSUBISHI HIGH VOLTAGE DIODE MODULE
RM600DY-66S
High Voltage Diode Module HIGH POWER SWITCHING USE INSULATED TYPE
THERMAL CHARACTERISTICS
Symbol Rth(j-c) Rth(c-f) Item Thermal resistance Contact thermal resistance Conditions Junction to case (per 1/2 module) Case to Fin, λgrease = 1W/m·K D(c-f)=100µm, (per 1/2 module) Min — — Limits Typ — 24.0 Max 48.0 — Unit K/kW K/kW
MECHANICAL CHARACTERISTICS
Symbol Mt Ms m Item Mounting torque Mass Conditions M8: Main terminals screw M6: Mounting screw — Min 6.67 2.84 — Limits Typ — — 1.5 Max 8.24 3.43 — Unit N·m N·m kg
PERFORMANCE CURVES
FORWARD CHARACTERISTICS (TYPICAL) 1200 0.4 REVERSE RECOVERY ENERGY CHARACTERISTICS (TYPICAL) VR = 1650V, di/dt = 1200A/µs Tj = 125°C, LS = 200nH
1000
REVERSE RECOVERY ENERGY Erec (J/p)
7
FORWARD CURRENT IF (A)
0.3
800
600
0.2
400
0.1
200 Tj = 25°C Tj = 125°C 0 1 2 3 4 5 6
0
0
0
200
400
600
800
1000 1200 1400
FORWARD VOLTAGE VF (V)
FORWARD CURRENT IF (A)
High Voltage Diode Module
May 2009 3
MITSUBISHI HIGH VOLTAGE DIODE MODULE
RM600DY-66S
High Voltage Diode Module HIGH POWER SWITCHING USE INSULATED TYPE
REVERSE RECOVERY CHARACTERISTICS (TYPICAL) 102
7 5
REVERSE RECOVERY SAFE OPERATING AREA (RRSOA) 104
7 5
1600 1400 1200 1000 800 600 400 200 0 VR ≤ 2200V, di/dt ≤ 1450A/µs Tj = 125°C
VR = 1650V, di/dt = 1200A/µs Tj = 125°C, LS = 200nH
REVERSE RECOVERY CURRENT Irr (A)
REVERSE RECOVERY TIME trr (µs)
3 2
3 2
101
7 5 3 2
103 Irr
7 5 3 2
100
7 5 3 2
trr
102
7 5 3 2
10-1 2 10
2
3 45
7 103
2
3 45
7 104
101
REVERSE RECOVERY CURRENT Irr (A)
0
1000
2000
3000
4000
FORWARD CURRENT IF (A)
REVERSE VOLTAGE VR (V)
TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS 1.2
NORMALIZED TRANSIENT THERMAL IMPEDANCE
Rth(j–c) = 48K/kW 1.0
0.8
0.6
0.4
0.2
0 -3 10 2 3 5 7 10-2 2 3 5 7 10-1 2 3 5 7 100 2 3 5 7 101 TIME (s)