Hydraulic Press Assembly
Hydraulic Press Assembly
Operation Manual
Order No. 19286-1000
Description
Operation
Maintenance
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 1 of 30
Hydraulic Press Assembly
Safety Warnings and Information
Read and understand all of the instructions and safety information in this manual before
operating or servicing this tool.
Keep this manual available when using this tool.
Replacement manuals are available for download at no charge at www.molex.com.
SAFETY ALERT SYMBOL
This symbol is used to call your attention to hazards or unsafe practices which could result in an injury
or property damage. The signal word, defined below, indicates the severity of the hazard. The message
after the signal word provides information for preventing or avoiding the hazard.
DANGER:
DANGER
Indicates an imminently hazardous situation which, if not avoided, could result in death or serious injury.
WARNING:
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION:
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
CAUTION may also be used to alert against unsafe practices associated with events that could lead
to personal injury.
WARNING
Always wear proper eye protection when
Operating or servicing this equipment.
Failure to wear eye protection could result
in serious eye injury from flying debris.
WARNING
Never wear clothing or jewelery that is loose or
That could potentially hang into the equipement
and get caught.
Failure to observe this warning could result in
Severe Injury or death.
WARNING
Never operate, service, install, or adjust this
machine without proper instruction and without
first reading and understanding the instructions
in this manual and all applicable tool and/or
wire processing machine.
manuals.
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
WARNING
Heavy Object
To avoid muscle strain or back injury, use lifting
aids and proper lifting techniques when removing
or replacing.
Failure to observe these precautions may result in
injury or property damage.
WARNING
Never install or service this machine while
connected to any electrical power source.
Disconnect power by unplugging this tool
from its power source.
Failure to observe this warning could result
In severe injury or death.
WARNING
Always wear proper ear protection
when Operating or servicing this applicator.
Failure to observe these precautions may result in
Injury or property damage.
UNCONTROLLED COPY
Page 2 of 30
Hydraulic Press Assembly
WARNING
WARNING
Do not use compressed air to clean
this equipment.
The forces created by compressed
air can force debris into the tool.
Never use this tool without guards or safety devices
that are intended to prevent hands from remaining
in the die space.
Failure to observe this warning could result
In severe injury or death.
Failure to observe these precautions may
result in injury or property damage.
WARNING
WARNING
Hand/Foot Operated
Maximum Capacity: 10,000 PSI
Do not exceed the PSI hydraulic rating noted
on the pump nameplate or tamper with the
internal high-pressure relief valve.
Before operating the hydraulic pump, all hose
connections must be tightened with proper tools.
Do not over-tighten. Connections need only be
tightened securely and leak-free. Over-tightening
may cause premature thread failure or may cause
high-pressure fittings to split at pressures lower
than their rated capacities
Pump
Before replenishing the oil level, retract the
system to prevent overfilling the pump reservoir.
An overfill may cause personal injury due
to excess reservoir pressure created when
cylinders are retracted.
Should a hydraulic hose ever rupture, burst, or need
to be disconnected, immediately shut off the pump
and shift the control valve twice to release all pressure.
WARNING
Never attempt to grasp a leaking hose under pressure
with your hands. The force of escaping hydraulic fluid
could cause serious injury.
Air
Hydraulic
Do not subject the hose to potential hazard such as fire,
Pump
extreme heat or cold, sharp surfaces, or heavy impact.
Do not allow the hose to kink, twist, curl, or bend so
tightly that the oil flow within the hose is blocked or
reduced. Periodically inspect the hose for wear because
any of these conditions can damage the hose and
possibly result in personal injury.
Cylinder
Do not exceed rated capacities of the cylinders.
Excess pressure may result in personal injury.
Do not set poorly balanced or off- center
loads on a cylinder. The load may tip and
cause personal injury.
Do not use the hose to move attached equipment.
Stress may damage hose and possibly cause personal
injury.
Hose material and coupler seals must be compatible
with the hydraulic fluid used. Hoses must not encounter
corrosive materials such as creosote-impregnated
objects and some paints. Consult the manufacturer
before painting a hose.
Creating pressure beyond rated capacities
may result in personal injury.
WARNING
Air
Supply
Shut off and disconnect the air supply when
the pump is not in use or before breaking
any connection in the system.
Never paint the couplers. Hose deterioration due to
corrosive materials may result in possible personal injury
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 3 of 30
Hydraulic Press Assembly
WARNING
MOLEX CANNOT BE RESPONSIBLE FOR DAMAGE OR INJURY RESULTING FROM UNSAFE PRODUCT
USE, LACK OF MAINTENANCE, OR INCORRECT PRODUCT AND SYSTEM APPLICATION.
CAUTION
Failure to observe these precautions may result in injury or property damage.
CAUTION
Never perform any service or maintenance other than as described in this manual.
Never modify, alter or misuse the equipment
Molex crimp specifications are valid only when used with Molex terminals, applicators and tooling.
Failure to observe this precaution may result in injury and property damage.
Tooling Technical Assistance
Molex offers tooling technical assistance for customers who may need some guidance for tooling adjustments. This support can
be obtained by calling either of the two numbers listed below and asking for the Molex Tooling Group.
Call Toll Free 1-800-786-6539 (US) 1-630-969-4550 (Global).
This assistance is limited to the operation and set-up of a customer’s Molex Press Assembly. Questions with regard to Molex
connector products or how to identify the proper tooling and/ or tooling documentation should be directed to your local Molex
personnel or Customer Service Representative.
When calling for service on the tool a copy of the Tooling Manual and Specific Applicator Tooling Specification Sheet should be
present and a person that is familiar with the applicator should be present. Be sure the following information is supplied:
1.
2.
3.
4.
5.
6.
7.
8.
Customer name
Customer address
Person to contact such as (name, title, e-mail, and telephone number
Press order number (Lease number also if applicable)
Serial number (Lease number also if applicable)
Molex Connector product order number
Urgency of request
Nature of problem
Molex Application Tooling Group
2200 Wellington Court
Lisle, IL 60532, USA
Tel: +1 (630) 969-4550
Fax:+1 (630) 505-0049
Visit our Web site at http://www.molex.com
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 4 of 30
Hydraulic Press Assembly
Table of Contents
Contents
Hydraulic Press Assembly ............................................................................................................................................. 1
Order No. 19286-1000................................................................................................................................................... 1
Safety Warnings and Information .................................................................................................................................. 2
Table of Contents .......................................................................................................................................................... 5
Section 1 ....................................................................................................................................................................... 6
General Description .................................................................................................................................................. 9
1.1
Description .................................................................................................................................................... 9
1.2
Features ........................................................................................................................................................ 9
1.3
Technical Specification .................................................................................................................................. 9
1.4
Delivery Check .............................................................................................................................................. 9
1.5
Tools.............................................................................................................................................................. 9
Section 2 ..................................................................................................................................................................... 10
Hydralic Head Crimper (19286-0117) .......................................................................................................................... 10
Principal Mechanical Parts of the 19286-0117 (PPHHLS) ...................................................................................... 11
2.1
Set-Up ......................................................................................................................................................... 12
2.2
Hydraulic Connections and Optional Bench Mounting................................................................................. 12
2.3. Installation of Tool Kits ................................................................................................................................ 13
2.4
Terminal Specifications and Crimping Operation......................................................................................... 14
Section 3 ..................................................................................................................................................................... 15
Terminal Locator (19286-0300) ............................................................................................................................... 15
3.1
Removing and Installing the Guards and the Terminal Locator Assembly................................................... 16
3.2
Operation..................................................................................................................................................... 16
3.3
Adjustments................................................................................................................................................. 18
3.4
Tool Change Over ....................................................................................................................................... 19
Section 4 ..................................................................................................................................................................... 20
Preventive Maintenance.......................................................................................................................................... 20
4.1
Lubrication ................................................................................................................................................... 21
4.2
Bleeding Air From The System .................................................................................................................... 21
4.3
Inspecting The Hydraulic Fluid Level ........................................................................................................... 21
4.4
Draining and Flushing the Reservoir ........................................................................................................... 21
4.5
Refilling The Reservoir ................................................................................................................................ 21
4.6
Venting the Reservoir .................................................................................................................................. 22
4.7
Priming the Pump Unit................................................................................................................................. 22
4.8
Periodic Cleaning ........................................................................................................................................ 22
4.9
Spare Parts ................................................................................................................................................. 23
4.10 Perishable Parts (Tool Kits) ......................................................................................................................... 23
4.11 Storage ........................................................................................................................................................ 23
Section 5 ..................................................................................................................................................................... 24
5.1
19286-1000 Main Parts List and Assembly Drawings ................................................................................. 25
5.1
19286-0051 Parts List and Assembly Drawing ............................................................................................ 26
5.2
19286-0117 Parts List and Assembly Drawing ............................................................................................ 27
5.3
19286-0300 Parts List and Assembly Drawing ............................................................................................ 28
5.4
Troubleshooting ........................................................................................................................................... 29
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 5 of 30
Hydraulic Press Assembly
Section 1
General Description
1
Description
2
Setup and Adjustments
3
Crimping Dies Go-No go
4
Preventive Maintenance
5
Parts List, Assembly Drawings and Troubleshooting
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 6 of 30
Hydraulic Press Assembly
Section 1
General Description
1.1.
Description
1.2.
Features
1.3.
Technical Specifications
1.4.
Delivery Check
1.5.
Tools
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 7 of 30
Hydraulic Press Assembly
Principal Mechanical Parts of the 19286-1000
FILTER
REGULATOR
GAUGE
AIR
HOSE
HYDRAULIC HOSE
ASSEMBLY
HYDRAULIC
HEAD
ASSEMBLY
PUTT PUMP
POWER UNIT
C-FRAME STAND
ASSEMBLY
RESERVOIR
UNIT
VENTED CAP
TERMINAL
LOCATOR
ASSEMBLY
Figure 1-1
CRIMP DIES
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 8 of 30
Hydraulic Press Assembly
General Description
1.4
1.1 Description
Carefully remove the Molex Hydraulic Press
Assembly from its shipping container and
determine that the following items are included in
the package.
The Molex Hydraulic Press Assembly includes
the basic Molex Hydraulic Head Crimper (Order
No. 19286-0117) with added features to Crimp
the Imperium Plus product line.
Delivery Check
The crimping Dies are not included with the
19286-1000 press assembly. Refer to the
Section 2.4 for the application chart for die order
numbers and description.
Hydraulic Head Crimper
19286-0117
C-Frame Stand Assembly 19286-0051
Terminal Locator Assembly 19286-0300
Pump Assembly with hoses, filter, regulator,
and gauge assembly (Includes vented cap
for pump)
1.2 Features
Operation Manual
A fully adjustable terminal locator designed for
the Imperium Product Line
All guards and terminal locator can be reversed
for right or left hand operation
Crimping dies are easily and quickly
interchanged to reduce production down time.
Complete portable system that allows tool to be
moved and stored easily.
1.3 Technical Specification
1.5
ATS-192861000
Tools
The following tools are recommended for setup
and adjustments to this tool.
1.
2.
3.
4.
5.
Metric standard hex wrench set
Inch standard hex wrench set
Adjustable wrench
Wire stripper / cutter
Screw driver
Pneumatic:
Supply Pressure: 100 PSI (6.9 Bars)
125-PSI max. (8.6 Bars max.)
Cycle Time: 15 seconds
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 9 of 30
Hydraulic Press Assembly
Section 2
Hydralic Head Crimper (19286-0117)
Set-Up and Operation
2.1.
Setup
2.2.
Connection and Bench Mounting
2.3.
Installation of Tool Kits
2.4.
Terminal Specifications and Crimping Operation
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 10 of 30
Hydraulic Press Assembly
Principal Mechanical Parts of the 19286-0117 (PPHHLS)
FILTER
REGULATOR
GAUGE
AIR
HOSE
HYDRAULIC HOSE
ASSEMBLY
PUTT PUMP
POWER UNIT
HYDRAULIC
HEAD
ASSEMBLY
RESERVOIR
UNIT
VENTED CAP
REF
C-FRAME STAND
ASSEMBLY
(NOT INCLUDED WITH
THE 19286-0117 PRESS
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
Figure 2-1
UNCONTROLLED COPY
Page 11 of 30
Hydraulic Press Assembly
CAUTION: Always disconnect the air supply until the system is ready to operate.
2.1 Set-Up
The principal mechanical parts of the 19286-1000 are illustrated in Figure 2-1 and Section 5 in this
document.
Air Supply Hook-Up
WARNING: Seal all external pipe connections with a high quality, non-hardening pipe sealant. Teflon
tape may also be used to seal hydraulic connections if only one layer of tape is used.
1. Select the 1/4 NPT threaded fittings that are compatible with your air supply.
2. Remove the red plastic thread protector from the putt pump on the air connection. Pull out and discard then
attach the air fitting.
3. Next, install the fittings to the filter, regulator, and gauge unit. The air supply should be 20 CFM (550 L/M)
and 100 PSI (6.9 Bars) to obtain the rated hydraulic output. Air pressure should be regulated to a maximum
of 125 PSI (8.6 Bars). See Figure 2-2.
4. Before installing the hydraulic hose, unscrew the square nut on the putt pump outlet and discard. Attach the
hose assembly to the hydraulic fluid outlet.
HYDRAULIC
HOSE
QUICK DISCONNECT
COUPLER
FILTER, REGULATOR,
AND GAUGE
LUBRICATOR
(OPTIONAL)
FILTER CAP RED
FOR SHIPPING AND
BLACK (VENTED)
FOR OPERATION
HYDRAULIC HEAD
ASSEMBLY
AIR SUPPLY
CUSTOMER
SUPPLIED
DUST CAP
REF
PUMP
AIR HOSE
Figure 2-2
2.2 Hydraulic Connections and Optional Bench Mounting
1.
2.
3.
4.
Remove the dust cap from the cylinder on the crimp head.
Connect the quick disconnect coupler onto the cylinder inlet on the crimp head. See figure 2-2.
Replace the red filler cap on the pump reservoir with the black-vented cap that is supplied with the unit.
To mount the hydraulic head assembly to the optional C-Frame stand, loosen the three thumbscrews in
the stand.
5. Place the hydraulic head in the stand with the cylinder facing up. Tighten the thumbscrews; making sure
the hydraulic head is securely positioned.
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 12 of 30
Hydraulic Press Assembly
Note: The safety guard panals will need to be removed before attempting to fasten the hydraulic to a work
bench. See Section 3.1 Removing and Installing the Guards and the Terminal Locator Assembly for more
information.
6. When using the optional C-Frame stand, be sure the C-Frame stand assembly is securely fastened to a
clean, sturdy workbench or table in a well-lighted area. Fasten the stand with four #3/8-16 SHCSs, nuts,
and washers of sufficient length for the tabletop. (Not supplied). See Figure 2-4. (Some stands may have
two mounting holes instead of four.)
C-FRAME
STAND
#3/8-16
SHCS (4)
C-FRAME
STAND
HYDRAULIC
HEAD
#3/8 WASHER
(8)
THUMB
SCREW (3)
Figure 2-3
2.3.
Installation of Tool Kits
WORK BENCH
Figure 2-4
#3/8-16
HEX NUT (4)
CAUTION: Always disconnect the air supply until the system is ready to operate
Before crimping, set the recommended air pressure gauge for the hydraulic pump (See Section 2.1) to obtain
the proper crimp.
#8-32 SET SCREW
TOP TOOL HOLDER
PUNCH
(NEST)
TOOL
HOLDERS
ANVIL
(INDENTOR)
Figure 2-5
#8-32 SETSCREW
LOWER TOOL
HOLDER
HYDRAULIC
HEAD
1. Connect the female coupler firmly with the male coupler of high-pressure rubber hose, which is attached
to the hydraulic pump.
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 13 of 30
Hydraulic Press Assembly
2. Select the proper set of dies for the terminal being crimped. The wire size is marked on each die. See
Section 2.4.
CAUTION: Be sure to use the correct pair of dies for the appropriate wire and terminal.
3. Loosen the #8-32 setscrew in the upper tool holder in the hydraulic head assembly. Place the punch (Nest)
in the top tool holder and retighten the setscrew. See Figure 2.5.
4. Loosen the #8-32 set screw in the lower tool holder in the hydraulic head assembly. Then, place the anvil
(Indentor) in the lower tool holder of the hydraulic head assembly and retighten the setscrew.
CAUTION: A wrong combination of dies may cause critical damage to the tool.
2.4
Terminal Specifications and Crimping Operation
SCOPE
This tooling is designed to crimp Molex Imperium and Imperium Plus.
Imperium and Imperium Plus
Wire
Size
Wire
Finish
Bare Copper
1 AWG
Pre-Tinned
Post-Tinned
Bare Copper
2/0
Pre-Tinned
Post-Tinned
Crimp Die Application Chart
Wire Type
Terminal ►Crimp Die
Press
Conductor Diameter.range (mm) Order No.
Order No.
Order No.
779 (strand)/30
171423-1401 19290-0100
(9.40 Max. Conductor Diameter)
817 (strand)/30
171423-1401 19290-0100 19286-1000
(9.40 Max. Conductor Diameter)
779 (strand)/30
171423-1401 19290-0100
(9.40 Max. Conductor Diameter)
1254 (strand)/30
171423-1201 19290-0350
(11.3 Max. Conductor Diameter)
1330 (strand)/30
171423-1001 19290-0300 19286-1000
(12.50-11.35mm Diameter)
1254 (strand)/30
171423-1001 19290-0300
(12.50-11.35mm Diameter)
►See the ATS Document for the proper Crimp Die.
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 14 of 30
Hydraulic Press Assembly
Section 3
Terminal Locator (19286-0300)
3.1
Installing Guards and Terminal Lcator Assemblies
3.2
Operation
3.3
Adjustments
3.4
Tool Change Over
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 15 of 30
Hydraulic Press Assembly
3.1 Removing and Installing the Guards and the Terminal Locator Assembly
CAUTION: Always disconnect the air supply until the system is ready to operate.
The safety guards and the terminal locator assembly are factory installed on the 19286-1000 Press.
The clear safety guard panels will need to be temporarily removed for crimp die replacement or terminal
locator replacement.
1.
2.
3.
4.
Remove the (12) twelve M5 SHCS holding the front and side safety guards.
Remove the safety guards. See Figure 3-1.
When all set up and adjustments are made reinstall the safety guards.
Tighten the M5 SHCS.
REMOVE THIS SAFTEY GUARD
PANEL BEFORE MOUNTING
THE PRESS TO A WORK BENCH
SIDE
SAFTEY GUARD
PANEL REMOVED
M5 SHCS (4)
FRONT
SAFTEY GUARD
PANEL REMOVED
Figure 3-1
M5 SHCS (4)
The Terminal Locator Assembly 192860300 is for the Imperium and Imperium Plus product line. This
assembly ensures the correct location of the terminal during crimping.
3.2 Operation
1. Insert the properly stripped cable into the terminal barrel.
2. Position the terminal into the slot of the safety guard shown in figure 3-2 and above the the lower crimp
tool (anvil) until it stops.
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 16 of 30
Hydraulic Press Assembly
LOWER TOOLING
(ANVIL)
TERMINAL STOP
192860306 (REF)
POSITION TERMINAL
THROUGH SAFETY
GUARD SLOT
TERMINAL
SERIES 171562
(REF)
TERMINAL LOACATOR
ASSEMBLY
Figure 3-2
SAFETY GUARD
3. The rim of the terminal should be against the stop of the terminal locator assembly.
4. For the correct terminal placement and the proper locator see Figure 3-3 and 3-4.
17.3mm-18.3mm
UPPER TOOLING
(PUNCH)
RIM OF TERMINAL
AGAINST STOP
STOP RECEPTACLE
No. 192860301
TERMINAL SERIES
No. 171562
LOWER CRIMP
TOOL (ANVIL)
Figure 3-3
Note: During termination a slight movement of the locator stop may occur. This is normal the locator stop will
return to the correct position once the terminal is removed from the press.
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 17 of 30
Hydraulic Press Assembly
UPPER TOOLING
(PUNCH)
15.0mm-14.0mm
RIM OF TERMINAL
AGAINST STOP
STOP PLUG
No. 192860307
LOWER CRIMP
TOOL (ANVIL)
TERMINAL SERIES
No. 171423
Figure 3-4
1. Depress the pedal on the putt pump to activate the tool. The crimping process is done in small
increments gradually allowing the press to fully crimp the terminal into the wire.
2. After the terminal is fully crimp, depress the elevated portion of the pedal to release the pump. This will
allow the tool to release.
3. Remove the crimp and inspect for proper crimp location.
3.3 Adjustments
CAUTION: Always disconnect the air supply when before any adjustments or changing out tooling.
The Terminal Location Adjustment must be adjusted,
so that the crimp is located as shown on Figuure 3-3
and 3-4.
ADJUSTING
SCREWS
LOCATOR
STOP
Note: It is not necessary to remove the safety
guarding to make this adjustment.
1. Insert a 4.0mm socket style wrench thru the holes
provided in the safety guards, and loosen the two
locking screws. Do not remove them. See Figure
3-5.
2. Using the 4.0mm socket wrench, turn the adjusting
screws to achieve the correct crimp location.
3. Turning the adjusting screws clockwise will
increase the distance from the rim to the crimp.
4. Turning the screws counter-clockwise decreases
this distance.
5. After adjustment are made, retighten the two locking screws.
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
LOCKING
SCREWS
UNCONTROLLED COPY
Figure 3-5
Page 18 of 30
Hydraulic Press Assembly
3.4 Tool Change Over
CAUTION: Always disconnect the air supply when before any adjustments or changing out tooling.
5. Before changing out the tooling the safety guard panels must be removed.
6. Remove the (8) eight M5 SHCS holding the front and side safety guards.
7. Remove the safety guards. See Figure 3-6.
SIDE
SAFTEY GUARD
PANEL REMOVED
FRONT
SAFTEY GUARD
PANEL REMOVED
M5 SHCS (4)
M5 SHCS (4)
Figure 3-6
8.
9.
10.
11.
12.
13.
To change the locator stop remove the (2) two M5 x 18 long SHCS on the locking block.
Remove the (2) springs in the frame stop.
Lift out the locator stop and set aside.
Install the new locator stop.
Replace the (2) springs and the locking block.
Install the (2) two M5 x 18 long SHCS on the locking block and tighten. See Figure 3-7.
REMOVE
LOCATOR
STOP
LOCKING
BLOCK
FRAME
STOP
M5 X 18 LONG
SHCS (2)
SPRING
(2)
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
NEW
LOCATOR
STOP
Figure 3-7
UNCONTROLLED COPY
Page 19 of 30
Hydraulic Press Assembly
Section 4
Preventive Maintenance
4.1
Lubrication
4.2
Bleeding Air From the System
4.3
Inspecting the Hydraulic Fluid Level
4.4
Draining and Flushing the Reservoir
4.5
Refilling the Reservoir
4.6
Venting the Reservoir
4.7
Priming the Pump Unit
4.8
Periodic Cleaning
4.9
Spare Parts
4.10
Perishable Parts
4.11
Storage
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 20 of 30
Hydraulic Press Assembly
4.1 Lubrication
WARNING: Any repair or servicing, which
requires dismantling the pump must be
performed in a dirt-free environment by a
qualified technician.
CAUTION: Always disconnect air supply before all
maintenance.
If the pump is operated on a continuous duty cycle for
extended periods, the manufacturer recommends an
automatic airline oiler be installed in the air inlet as
close to the pumping unit as possible.
Set the unit to feed approximately 1 drop of oil per
minute into the system. Use SAE No. 10 oil.
4.2 Bleeding Air From The System
During the initial moments of activation or after
prolonged use, a significant amount of air may
accummulate within the hydraulic system. This
entrapped air may cause the cylinder to respond
slowly or behave in an unstable manner.
To remove the air, run the system through several
cycles (extending and retracting the ram) free of any
load. The rams must be at a lower level than the pump
to allow air to be released through the pump reservoir.
4.4 Draining and Flushing the Reservoir
IMPORTANT: Wipe the pump exterior completely
clean before attempting this procedure!
1. Loosen and remove the six screws that fasten
the pump assembly to the reservoir. Remove the
pump assembly from the reservoir. Do not
damage the gasket, filter, or safety valve.
2. Clean the inside of the reservoir and refill with a
suitable, non-flammable flushing oil. Rinse the
filter clean.
3. Place the pump assembly back onto the reservoir
and secure with two of the six screws. For best
results, assemble the screws in opposite corners
of the housing.
4. Run the unit for several minutes. Use the same
method described in Section 3-7 (Priming the
pump unit)
5. Drain and clean the reservoir once more.
6. Refill the reservoir with an approved, clean
hydraulic oil and replace the pump assembly
(with gasket) on the reservoir. Assemble the six
machine screws and torque 25 to 30 in. lbs.
IMPORTANT: Drain and clean the other hydraulic
system components (hoses, cylinders, etc.) before
reconnecting them to the pump. This will prevent
contaminated oil from re-entering the pump.
4.5 Refilling The Reservoir
4.3 Inspecting The Hydraulic Fluid Level
CAUTION: Always disconnect air supply before all
maintenance.
1. Check the oil level in the reservoir after every
10 hours of use.
2. The oil level should come to within 1/2" of the
filler plug with all hoses attached.
3. Drain and replenish the reservoir with an
approved, high-grade hydraulic oil such as
OTC 16355 after every 300 hours of use.
Hoses: Hydraulic hoses on this unit carry a rating of
10,000 PSI.
Replacement hoses must carry the same rating.
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
CAUTION: Always disconnect air supply before all
maintenance.
1. If additional oil must be added to the reservoir,
use only an approved high-grade hydraulic oil
such as OTC 16355 (215 SSU @ 100° F).
2. Clean the entire area around the filler plug before
adding oil to the reservoir.
3. Remove the filler plug and insert a clean funnel
with filter.
4. The ram must be fully retracted and the air
supply disconnected when adding the oil to the
reservoir.
UNCONTROLLED COPY
Page 21 of 30
Hydraulic Press Assembly
4.6 Venting the Reservoir
To improve oil delivery and increase useable oil
capacity, vent the reservoir by removing the vent
screw from the filler plug before using the pump.
See Figure 4-1.
3. Remove the screwdriver and depress the pump
end of the pedal once more.
4. If the ram extends or pressure builds, the pump
has been sucessfully primed.
5. If the pump does not respond, repeat the
procedure, repeatedly jogging the air intake
valve while holding the pedal in the RELEASE
position.
4.8 Periodic Cleaning
CAUTION: Always disconnect air supply before all
maintenance.
VENT
SCREW
A routine should be established to keep the pump
as free from dirt as possible.
Figure 4-1
4.7 Priming the Pump Unit
If the pump unit must be primed, perform the
following procedure:
1. Depress the release end of the pedal while
holding down the air intake valve with a flathead
screwdriver. The air intake valve is located
directly under the pedal in the area marked
PUMP. This "button" is depressed
simultaneously with the RELEASE area of the
pedal during priming.
1. All unused couplers should be sealed with
thread protectors.
2. All hose connections must be free of grit and
grime.
3. Any equipment hooked up to the pump should
also be kept clean.
4. Use only approved, clean hydraulic oil, such as
OTC 16355 in this unit and change as
recommended (every 300 hours).
An example of a maintenance chart is shown
below. Copy and use this chart to track the
maintenance of your 19286-1000 or use this as
a template to create you own schedule or use
your company’s standard chart, if applicable.
2. Allow the pump to cycle approximately 15
seconds.
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 22 of 30
Hydraulic Press Assembly
Preventive Maintenance Chart
Daily: Clean. See Section 5.5.
As Required: Lubricate. See Section 5.1.
CHECK SHEET MONTH
Week
YEAR _________
Daily
Use
Days of the Week
MON
TUE
WED
THU
FRI
SAT
SUN
Solution
1
2
3
4
Lubrication
Change Hydraulic
oil
Bleeding Air From
the System
1 drop per minute
into the system
Use SAE No. 10 Oil
300 Hours
Use OTC 16355
After prolong use
Refilling Reservoir
10 hours or when needed
Cleaning
Hose connections free of grit
and dirt. Pump kept clean
Run the system thru
several cycles.
Use 215 SSU@100°F
(otc 16355)
Use soft cloth
Schedule should be adjusted up or down depending on usage. Molex recommends that a log of preventive
maintenance be kept with the tool.
4.9 Spare Parts
Customers are responsible for maintaining the tool. Spare parts are available from Molex. Moving and
functioning parts can be damaged or wear out over time and will require replacement. Molex recommends that
the customer keep some or all of them in stock to reduce production down time.
4.10 Perishable Parts (Tool Kits)
Customers are responsible for maintaining the 19286-1000. Perishable parts are those parts that come in
contact with the product and will wear out over time. Molex recommends that all customers keep at least one
set of the perishable tooling in stock at all times. This will reduce the amount of production down time.
4.11 Storage
When storing the 19286-1000 assembly, disconnect the air supply and store in a dry location. If the pump is
disconnected from the hydraulic head, reinstall the dust cap on the cylinder inlet. When transporting, reinstall
the red-vented cap on the pump reservoir.
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 23 of 30
Hydraulic Press Assembly
Section 5
5.1.
Parts Lists and Assembly Drawing
5.2.
Troubleshooting
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 24 of 30
Hydraulic Press Assembly
5.1 19286-1000 Main Parts List and Assembly Drawings
19286-1000 - Hydraulic Press Assembly Figure 6-1
Item Order No.
Description
Qty
1
19286-0051
C-FrameStand Assembly
1 (Figure 5-2)
2
19286-0117 Putt Pump Hydraulic Head Crimper
1 (Figure 5-3)
3
19286-0300
Terminal Locator Assembly
1 (Figure 5-4)
2
1
2
1
Figure 5-1
3
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 25 of 30
Hydraulic Press Assembly
5.1
19286-0051 Parts List and Assembly Drawing
19286-0051 - C-Frame Stand Assembly Figure 5-2
Item
Order No.
Description
Quantity
1
19286-0302
Side Guard
1
2
19286-0304
Front Guard
1
3
19286-0310
Left Side Guard
1
4
19286-0311
Mounting Bracket
4
5
19286-0400
Guard Assembly (All parts listed)
0
6
19286-0401
Adapter Plate
4
7
19286-0402
Spacer Plate
1
8
19286-0126
Right Plate
1
9
19286-0127
Left Plate
1
10
19286-0128
Base Plate
1
11
19286-0129
Back Plate
1
12
63600-1863
Thumb Screw
3
13
N/A
M5 by 10 Long SHCS
12**
14
N/A
M6 by 30 Long SHCS
8**
** The following purchased parts are available from an Industrial supply company such as MSC (1-800-645-7270).
13
(4)
3
14
8
11
(4)
9
12
(3)
6
(4)
7
13
4
(4)
14
(4)
(4)
10
2
1
Figure 5-2
13
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
(4)
Page 26 of 30
Hydraulic Press Assembly
5.2
19286-0117 Parts List and Assembly Drawing
19286-0117 - Main Assembly Figure 5-3
Item Order No.
Description
4
19286-0041
Hydraulic Hose Assembly-6 Feet
5
19286-0049
Filter Regulator with Gauge
6
19286-0059
Putt Pump Power Unit
7
19286-0103 Air Hose 1/4 NPT Male Fitting-10 Feet
8
19286-0051
C-Frame Stand Assembly
9
19286-0005
Hydraulic Head Assembly
10
19286-0006
HHLS Tool Holder
Order separately
Qty
1
1
1
1
Optional
1
2
2
4
1
6
3
7
5
Figure 5-3
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 27 of 30
Hydraulic Press Assembly
5.3
19286-0300 Parts List and Assembly Drawing
19286-0300 – Terminal Locator Assembly Figure 5-3
Item
Order No.
Description
Quantity
1
11-21-5694 (AM8921-221)
Compression Spring
2
2
19286-0301
Stop Receptacle
1
3
19286-0306
Terminal Stop Retainer
1
4
19286-0307
Stop Plug
1
5
19286-0308
Frame Stop
1
6
19286-0309
Locking Block
1
7
19286-0312
Terminal Stripper Bar
2
8
19286-0313
Filler Bar
1
9
N/A
M3 by 8 long SHCS
2**
10
N/A
M5 by 18 long SHCS
4**
11
N/A
M5 by 25 long SHCS
4**
12
N/A
M6 by 20 long SHCS
2**
13
N/A
M5 Flat Washer
4**
** The following purchased parts are available from an Industrial supply company such as MSC (1-800-645-7270).
19286-0051
REF
2
4
(2)
7
11
(4)
5
12
(4)
(2)
3
13
9
10 (2)
1
(2)
8
(2)
6
10
Figure 5-3
(2)
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 28 of 30
Hydraulic Press Assembly
5.4 Troubleshooting
Symptom
Pump reciprocates but no
oil delivery.
(Ram will not extend)
Low oil delivery.
(Ram extends slowly)
Pump will not build to maximum
Pressure.
(No visible leakage)
Pump builds pressure but will
not hold system pressure.
Cause
Low oil level.
Pump not primed.
Check oil filter for contamination.
Reservoir not vented
Inadequate air supply:
1. Check air input supply.
2. Contamination, check airside of pump.
Thoroughly inspect the slot in the air
cylinder tub.
Solution
Replenish oil reservoir.
Depress air intake valve and hydraulic
release valve simultaneously.
Invert pump. Fill intake filter with oil.
Depress pedal end marked “pump.
Remove filter and clean.
1. Should be 20 CFM mininum.
2. Clean and reassemble.
Hydraulic failure:
1. Check the oil filter forcontamination.
2. Air in hydraulic system.
1. Clean and reinstall.
2. Bleed the system as described
in "Preventative Maintenance"
Section.
Check the air supply.
100 PSI is required to obtain
maximum pressure.
Check hydraulic connections.
Refit as needed.
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 29 of 30
Hydraulic Press Assembly
For more information use the Crimping Testing and Inspection Handbook for Industrial (Closed Barrel
products).
There is no charge for this book, which can be found on the Molex Website (www.molex.com) or contact you local
Molex sales engineer.
Visit our Web site at http://www.molex.com
Doc No. TM-192861000 Release Date: 10-12-12
Revision: A
Revision Date: 10-12-12
UNCONTROLLED COPY
Page 30 of 30