HS Dock™ Plug Extractor Kit
HS Dock™
Plug
Extractor Kit
Application Tooling
Specification Sheet
Order No. 62202-0220
FEATURES
This tool is designed for the removal of wafers from an HS Dock™ plug connector assembled to a printed
circuit board.
SCOPE
Products: 1.20mm by 3.50mm Pitch Plateau HS Dock™ Plug, Right Angle, 72 Circuits. See Product List below
for specific part numbers.
Product List
The following is a partial list of the product order numbers and their specifications this tool is designed to run.
Updates to this list are available on www.molex.com.
Series No. Circuit Size
Assembly Order Number
75018
72
75018-0100 75018-0301 75018-0305 75018-4100 75018-7100
Tool Operation
1. Place the Upper Housing Puller over the connector, ensuring the two tabs are behind both ends of the shroud
and the support legs are aligned over the front edge of the PCB. See Figure 1.
UPPER
HOUSING
PULLER
Figure 1
CONNECTOR
2. Rotate the thumbscrew clockwise so the upper housing will be pulled away from the connector. After the
housing is loose, rotate the thumbscrew counterclockwise to remove the Upper Housing Puller and finish
removing (by hand) the upper housing from the connector. See Figure 2.
Doc No: ATS-622020220
Revision: B
Release Date: 01-21-09
Revision Date: 10-08-13
UNCONTROLLED COPY
Page 1 of 3
HS Dock™ Plug Extractor Kit
CONNECTOR
UPPER
HOUSING
Figure 2
3. Press down on the front of the retention clip by hand or use a small, piece of flat stock. It will become loose
enough to remove it by hand. See Figure 3.
4. Rotate the thumbscrew of the Wafer Extractor counter-clockwise to open the tool. Slide the tool over the first
wafer by capturing the tips of the wafer in the three corresponding pockets, (these pockets will hook under the
wafer being removed). This will align the support legs over two adjacent wafers and the lower housing. See
Figure 4.
RETENTION
CLIP
THUMBSCREW
WAFER
EXTRACTOR
POCKETS
Figure 3
Figure 4
5. Rotate the thumbscrew clockwise to pull the wafer from the PCB. When an audible “click” is heard, this
indicated the wafer has been extracted. Discard the extracted wafer. See Figure 5.
THUMBSCREW
WAFER
Figure 5
Doc No: ATS-622020220
Revision: B
Release Date: 01-21-09
Revision Date: 10-08-13
UNCONTROLLED COPY
Page 2 of 3
HS Dock™ Plug Extractor Kit
6. Load the new wafer in the empty cavity of the lower housing.
7. Align the wafer tips to the edge of the compression pad on the Wafer Press. Make sure the plunger of the
press is approximately in the center so the wafer will be engaged. Pull down the toggle clamp until the wafer is
completely seated. See Figure 6.
RETENTION CLIP
ALIGNMENT HOLES
TOGGLE
CLAMP
UPPER
HOUSING
WAFER
Figure 6
Figure 7
COMPRESSION PAD
8. Install the retention clip to the lower housing by aligning the holes in the stiffener to the bosses in the lower
UPPER HOUSING/
housing. While holding the stiffener in place, slide
RETENTION
CLIP PRESS
the upper housing on until it just starts to engage
the stiffener. See Figure 7.
Figure 8
9. Place the Upper Housing/Retention Clip Press over
the connector ensuring the moveable bar is in front
of the connector. Rotate the two thumbscrews
counterclockwise until resistance is felt with both
thumbscrews. Now the moveable bar is aligned
with the upper housing. Continue rotating the
thumbscrews simultaneously until they stop. See
Figure 8.
10. To open the tool, rotate thumbscrews clockwise
until they stop. Remove the clip press from the
connector.
CAUTION: Molex application tooling specifications are valid only when used with Molex connectors and tooling.
Contact Information
For more information on Molex application tooling please contact Molex at 1-800-786-6539.
Visit our Web site at http://www.molex.com
Doc No: ATS-622020220
Revision: B
Release Date: 01-21-09
Revision Date: 10-08-13
UNCONTROLLED COPY
Page 3 of 3