zQSFP+ Multi-Port Connector Tooling
2-by-2
zQSFP+
Extraction Tool
Application Tooling
Specification Sheet
Order No. 62202-5220
FEATURES
Used for removal of a zQSFP+ assembly from a PCB
Removes connector from the PCB without damage to the board
Use tool 62202-5260 to insert 171565 and 171722 connector assemblies
Use tool 62202-5310 to insert 172564 connector assemblies
SCOPE
Products: zQuad Small Form-factor Pluggable Plus (zQSFP+) Cage Assembly, with Elastomeric Gasket or Metal
EMI Gasket, 2 by 2 Enhanced EMI Cage Construction.
Connector Series No.
Connector Order No.
171565
171565-0001 171565-0002 171565-0003 171565-2001 171565-2002 171565-2003
171722
171722-2001 171722-2002 171722-2003 171722-2062
172564
171564-2001 171564-2002 171564-2003
Notes:
1. See the following pages for tooling operation instructions.
2. These tools require a “Keep Out Zone” around the connector free of components. The right and left sides
should be 0.08” (2mm). See Figure 1.
zQSFP+ CAGE
ASSEMBLY
zQSFP+ CAGE
172564 ASSEMBLY
5mm
MINIMUM
3.5mm
MINIMUM
(BOTH SIDES)
Doc. No: ATS-622025220
Revision: C
PCB
KEEP OUT
ZONE
Release Date: 04-15-13
Revision Date: 02-10-17
2mm
MINIMUM
(BOTH SIDES)
Figure 1
UNCONTROLLED COPY
PCB
KEEP OUT
ZONE
Page 1 of 3
zQSFP+ Multi-Port Connector Tooling
SUPPORT LOCK
(INSERT)
REMOVE THE
SCREWS AND
WASHERS
PCB
CONNECTOR
ASSEMBLY
SLIDE UP
SLIDE
REMOVE
UPPER
TOOLING
SUPPORT BLOCK
(FULLY SEATED)
SUPPORT
TOOLING
Figure 2
Figure 3
CONNECTOR ASSEMBLY
Description
The following instructions are used for removing a 2-by-2 connector from a PCB:
Operation
1. Disassemble the (2) halves by unscrewing the screws on the top of
the “upper tooling”. See Figure 2.
2. Remove the upper tooling from the support tooling.
3. Insert the support tooling into the cage ports until it is fully seated.
See Figure 3.
4. Place the top removal assembly over the support tooling and the
cage assembly, aligning the screw holes of the top removal
assembly with the threaded holes in the support blocks. See Figure
4.
5. If the top removal assembly does not fit over the cage, the side
supports of the top assembly can be adjusted farther from the cage
sides.
6. Place the washers and M5 screws into the holes in the top removal
assembly; turn the screws clockwise until they are started in the
support blocks.
SCREWS
AND
WASHERS
TOP
REMOVAL
ASSEMBLY
SUPPORT
TOOLING
PCB
Figure 4
Doc. No: ATS-622025220
Revision: C
Release Date: 04-15-13
Revision Date: 02-10-17
UNCONTROLLED COPY
Page 2 of 3
zQSFP+ Multi-Port Connector Tooling
7. Using a 4mm hex wrench, tighten each screw, one turn in an alternating pattern until the cage assembly is
removed from the PCB. See Figure 5.
SUPPORT
TOOLING
PCB
PCB
CONNECTOR
ASSEMBLY
CONNECTOR
ASSEMBLY REMOVED
Figure 5
CAUTION: Molex application tooling specifications are valid only when used with Molex connectors and tooling.
Application Tooling Support
Phone: +1-402-458-TOOL (8665)
E-Mail: applicationtooling@molex.com
Website: www.molex.com/applicationtooling
Doc. No: ATS-622025220
Revision: C
Release Date: 04-15-13
Revision Date: 02-10-17
UNCONTROLLED COPY