Air Powered Tool
AIR POWERED TOOL
Operating and Maintenance Instructions
Order No: 63816-0100
Optional Bench Adapter with Foot Switch
Order No: 63816-0500
Description
Operation
Maintenance
Order No: TM-638160100
Revision: B
Release Date: 02-20-08
Revision Date: 05-28-10
UNCONTROLLED COPY
Page 1 of 17
Air Powered Tool
Table of Contents
1.
Safety Warnings and Information
2.
General Description
3.
Set-Up and Adjustments
4.
Preventive Maintenance
5.
Parts List, Assembly Drawings and Troubleshooting
Order No: TM-638160100
Revision: B
Release Date: 02-20-08
Revision Date: 05-28-10
UNCONTROLLED COPY
Page 2 of 17
Air Powered Tool
Section 1
Safety Warnings and Information
Read and understand all of the instructions and safety information in this
manual before operating or servicing this tool.
Keep this manual available when using this tool.
Replacement manuals are available upon request at no charge at
www.molex.com.
SAFETY
ALERT
SYMBOL
This symbol is used to call your attention to hazards or unsafe practices which could result in an injury
or property damage. The signal word, defined below, indicates the severity of the hazard. The message
after the signal word provides information for preventing or avoiding the hazard.
DANGER
WARNING
CAUTION
DANGER:
Indicates an imminently hazardous situation which, if not avoided, will result in
death or serious injury.
WARNING:
Indicates a potentially hazardous situation which, if not avoided, will result in
death or serious injury.
CAUTION:
Indicates a potentially hazardous situation which, if not avoided, may result in
minor or moderate injury. CAUTION may also be used to alert against unsafe
practices associated with events that could lead to personal injury.
WARNING
WARNING
Wear eye protection when operating
or servicing this tool.
Pinch points:
Keep hands away from the crimping
head when crimping.
Failure to wear eye protection could
result in serious eye injury from flying
debris.
WARNING
Failure to observe this warning could
result In severe injury or death.
WARNING
Wear appropriate ear protection when Inspect tool and dies before use. Replace any worn or damaged parts.
operating this tool.
A damaged or improperly assembled tool can break and strike someone
nearby.
Failure to wear ear protection could
result in loss of hearing over a period Failure to observe this warning could result in severe injury or death.
of time.
Order No: TM-638160100
Revision: B
Release Date: 02-20-08
Revision Date: 05-28-10
UNCONTROLLED COPY
Page 3 of 17
Air Powered Tool
NEVER
INSTALL OR SERVICE THIS MACHINE WHILE CONNECTED TO THE COMPRESSED AIR
SOURCE.
NEVER
WEAR LOOSE CLOTHING OR JEWELRY THAT MAY CATCH IN THE MOVING PARTS OF THIS
TOOL.
CAUTION
THE MOLEX 63816-0100 AIR POWERED TOOL IS DESIGNED TO BE USED WITH CRIMP TOOL
HEADS AND TOOLING SUPPLIED BY MOLEX. USE OF TOOL HEADS OR TOOLING FROM ANY
OTHER SOURCE MAY RESULT IN DAMAGE OR INJURY. MOLEX WILL NOT BE LIABLE FOR ANY
DAMAGE OR INJURY FROM USE OF NON-MOLEX COMPONENTS IN THIS TOOL.
WORK SAFELY AT ALL TIMES
For Service, Contact Your Local Molex Sales Office
Molex Application Tooling Group
2200 Wellington Court
Lisle, Illinois 60532 USA
Tel: 1-630-969-4550
Fax: 1-630-505-0049
Order No: TM-638160100
Revision: B
Release Date: 02-20-08
Revision Date: 05-28-10
UNCONTROLLED COPY
Page 4 of 17
Air Powered Tool
Section 2
General Description
2.1
Description
2.2
Features
2.3
Technical Specifications
2.4
Delivery Check
2.5
Tools
Order No: TM-638160100
Revision: B
Release Date: 02-20-08
Revision Date: 05-28-10
UNCONTROLLED COPY
Page 5 of 17
Air Powered Tool
2 General Description
Principal Mechanical Parts
AIR HOSE
TRIGGER
MAIN UNIT
FOOT SWITCH
(Optional)
AIR POWERED
CRIMP ADAPTER
BENCH MOUNT
CLAMP (Optional)
SWIVEL LOCK
Figure 2-1
2.1 Description
The Molex Air Powered Tool is designed to crimp a variety of insulated and uninsulated terminals and splices. This
tool has an automatic retractable system which returns the crimping adapter along with the crimping dies to the
starting position when the maximum force is reached. It is equipped with a special brake that will stop the forward
motion of the crimping dies when the trigger is released. The crimping head can be rotated 360° for better access
in difficult working situations. This unit requires a power unit and a modular crimp tool head.
2.2 Features
Light weight tool for high quantities of terminations.
Crimps a wide range of products with interchangeable tool heads and tool kits, which reduce the overall cost and
provide production flexibility.
Modular crimp heads are easily and quickly interchanged to reduce production down time.
Operated by hand or foot, stationary unit available.
Modular crimp heads can be rotated to at any angle to accommodate the operator.
Order No: TM-638160100
Revision: B
Release Date: 02-20-08
Revision Date: 05-28-10
UNCONTROLLED COPY
Page 6 of 17
Air Powered Tool
2.3 Technical Specifications
Dimensions (with tool head adaptor)
Length
342.9mm (13.50”)
Diameter
65.0mm (2.56“)
Weight
1.3kg (2.98lbs)
Production Rate
600 cycles per hour maximum, depending on operator skill and tool kit installed.
Operating Parameters
Cycle Time
Air Consumption per Cycle
Required pressure of filtered air suppy
1.0 seconds
.721 L (.025 cubic feet)
6 to 6.5 bar (87 to 94 psi) 8 bar maximum (116 psi)
2.4 Delivery Check
Carefully remove the Pneumatic Crimping Tool from its shipping container and determine that the following
items are included in the package.
63816-0100
TM-638160100
Pneumatic Crimping Unit with tooling adaptor
Operation Manual
2.5 Tools
The following tools are recommended for setup and adjustments to this tool.
1.
2.
3.
4.
Metric standard hex wrench set
Adjustable wrench
Wire stripper / cutter
Screwdriver
Order No: TM-638160100
Revision: B
Release Date: 02-20-08
Revision Date: 05-28-10
UNCONTROLLED COPY
Page 7 of 17
Air Powered Tool
Section 3
Set-Up and Adjustments
3.1.
Set-up
3.2.
Installing or Changing Modular Crimp Heads
3.3.
Operation
3.4.
Terminal Crimping
Order No: TM-638160100
Revision: B
Release Date: 02-20-08
Revision Date: 05-28-10
UNCONTROLLED COPY
Page 8 of 17
Air Powered Tool
3.1 Set-Up
1. Read the following instructions before attempting to operate this tool.
2. Connect an 8mm or 5/16” air hose to the fitting attached to the rear of the tool and to air supply 6 to 6.5 bar (87
to 94 psi). Do not exceed 8 bar (116 psi). May cause injury or damage to the tool. Air supply must be
equipped with an air filter regulator (not supplied by Molex). (Available from any industrial supply co.). See
Figure 3-1.
TRIGGER
SAFETY
TO AIR
SUPPLY
TRIGGER
AIR HOSE
MODULE CRIMP
HEAD (REF)
FILTER REGULATOR
LUBRICATOR
(NOT SUPPLIED)
Figure 3-1
If changing to the Optional bench adapter, remove the air hose and connect the tubing from the footswitch. See
Figure 3-2.
SECURE AIR
CRIMPING TOOL
IN POSITION
CONNECT TUBING FROM
FOOT SWITCH
WITH FITTING
TO AIR
SUPPLY
MODULE CRIMP
HEAD
(Reference)
(NOT SUPPLIED)
BENCH
ADAPTER
(OPTIONAL)
FOOT SWITCH
(OPTIONAL)
FILTER REGULATOR
LUBRICATOR
(NOT SUPPLIED)
Figure 3-2
Order No: TM-638160100
Revision: B
Release Date: 02-20-08
Revision Date: 05-28-10
UNCONTROLLED COPY
Page 9 of 17
Air Powered Tool
3. Next lock the trigger on the actuator by flipping the safety switch. Push the safety switch all the way down on the
end of the trigger to lock. See Figure 3-3.
SAFETY
(UNLOCKED)
SAFETY
(LOCKED)
TRIGGER
Figure 3-3
Note: Always use the safety or disconnect air supply when changing crimping heads.
4. For the proper crimping head see the tool part number on the label of the terminal/connector container.
5. Strip proper wire to minimum length located on label of terminal/connector container or on the air powered crimp
tool head specification sheet.
3.2 Installing or Changing Modular Crimp Heads
Before starting any work on any electrical applications:
1. Make sure there are no live cables or parts in the immediate area of the user.
2. Make sure the safety is in the locked position before changing heads.
WARNING
Remove the power source from the crimping tool before
installing and removing the modular crimp head.
Installing or Changing heads procedure:
1.
2.
3.
4.
Remove the locking pins (2) from the air powered crimp adapter on the air powered tool.
Pull the modular crimp head out of the adapter head.
To replace the modular crimp head, select the correct modular crimp head for the application needed.
While holding the air powered tool in one hand, grasp the modular crimp head with the other hand and slide it into
the air powered crimp adapter until the holes in the side plates of the crimp head line up with the holes in the
adapter.
5. Replace the locking pins (2) making sure that the modular crimp head is secure. The locking pins can be inserted
from either side of the adapter. See Figure 3-4.
Order No: TM-638160100
Revision: B
Release Date: 02-20-08
Revision Date: 05-28-10
UNCONTROLLED COPY
Page 10 of 17
Air Powered Tool
AIR POWERED
CRIMP ADAPTER
MODULAR
CRIMP HEAD
(NOT INCLUDED)
LOCKING PINS (2)
Figure 3-4
3.3 Operation:
To actuate the crimping tool, first lift the safety lock lever on the trigger. See Figure 3-3.
The tool can now be actuated by depressing the trigger and holding until the ram is fully extended.
After the ram has been extended fully, release the trigger and the ram will return.
If using the optional bench mount, lift the safety lock lever as described above. The tool is now actuated by
depressing the footswitch.
3.4 Terminal Crimping
Specifications and Instructions for crimping are included with the individual Modular Crimp Heads.
Order No: TM-638160100
Revision: B
Release Date: 02-20-08
Revision Date: 05-28-10
UNCONTROLLED COPY
Page 11 of 17
Air Powered Tool
Section 4
Preventive Maintenance
4.1
Periodic Cleaning
4.2
Storage
4.3
Warranty
4.4
Maintenance
Order No: TM-638160100
Revision: B
Release Date: 02-20-08
Revision Date: 05-28-10
UNCONTROLLED COPY
Page 12 of 17
Air Powered Tool
4.1 Periodic Cleaning
Always clean tool after use and keep moving parts clear of dirt and debris.
This tool is maintenance free, only the sliding ram in the crimping head has to be oiled regularly.
Before use:
1. Inspect dies for wear or damage such as cracks, gouges, or chips.
2. Inspect the tool for damage or leaks. If damage is detected, contact Molex to have the tool evaluated.
After use:
1. Wipe all tool surfaces clean with a damp cloth and mild detergent. Excessive dirt and grit can contribute to the
premature wear of the tool’s internal mechanical parts. If this tool becomes dirty with excessive debris it may jam
and become damaged during operation.
2. Fully retract the ram. Store in a cool, dry place.
WARNING
Do not use solvents or flammable liquids to
clean the crimping tool.
Solvents or flammable liquids could ignite and
cause serious injury or property damage.
Monthly:
1. Thoroughly clean all surfaces.
Annually or After 10,000 Crimps
1. Return the tool to a Molex representative for inspection.
A routine should be established to keep the tool as free from dirt as possible.
Order No: TM-638160100
Revision: B
Release Date: 02-20-08
Revision Date: 05-28-10
UNCONTROLLED COPY
Page 13 of 17
Air Powered Tool
An example of a maintenance chart is shown below. Copy and use this chart to track the maintenance of this
crimping tool or use this as a template to create your own schedule or use your company’s standard chart, if
applicable.
Preventive Maintenance Chart
CHECK SHEET MONTH
Week
YEAR _________
Daily
Use
Days of the Week
MON
TUE
WED
THU
FRI
SAT
Solution
SUN
1
2
3
4
Cleaning
Lubrication
Daily
Sliding ram
into crimping head
After use
Use SAE No. 10 Oil
Schedule should be adjusted up or down depending on usage. Molex recommends that a log of preventive
maintenance be kept with the tool.
4.2 Storage
In order to protect the tool against damages, this tool should be cleaned carefully and stored in a clean and dry
location.
4.3 Warranty
All tools are warranted free of manufacturing defects for a period of 30 days. Should such a defect occur, we will
repair or exchange the tool free of charge. This repair or exchange will not be applicable to altered, misused, or
damaged tools. This tool is designed for hand use only. After one year Molex recommends the crimping tool be
returned to Molex for inspection. Only the heads of the crimping tool are permitted to be changed by the operator.
If seals are damaged the warranty is void.
CAUTION: Molex crimp specifications are valid only when used with Molex terminals and tooling.
4.4 Maintenance
Crimping nest should be kept free of oil and all foreign particles.
Crimp tool head assemblies should be lubricated monthly by placing a few drops of light machine oil on the sliding
ram of the crimping tool.
Check the lubricator in the air supply and fill with SAE 10W oil as needed.
Check the air filter. To clean, remove the bowl and the filter element and clean with denatured alcohol.
Order No: TM-638160100
Revision: B
Release Date: 02-20-08
Revision Date: 05-28-10
UNCONTROLLED COPY
Page 14 of 17
Air Powered Tool
Section 5
Parts List, Assembly Drawing and Troubleshooting
5.1.
Parts List and Assembly Drawings
5.2.
Troubleshooting
Order No: TM-638160100
Revision: B
Release Date: 02-20-08
Revision Date: 05-28-10
UNCONTROLLED COPY
Page 15 of 17
Air Powered Tool
5.1
Parts List and Assembly Drawings
Item Order No
Description
Quantity
1
63816-0100
Air Powered Crimp Tool
1
2
63816-0700
Air Powered Crimp Adapter
(Included)
3
63816-0500 Optional Bench Adapter with Foot Switch (Sold Separately)
3
1
MODULE
CRIMP TOOL
(Reference)
3
2
3
Figure 5-1
Order No: TM-638160100
Revision: B
Release Date: 02-20-08
Revision Date: 05-28-10
UNCONTROLLED COPY
Page 16 of 17
Air Powered Tool
5.2
Troubleshooting
Symptom
Hand Actuated Unit
Power unit piston
will not
extend when actuated.
Foot Actuated Unit
Cause
Power unit not connected to
main air supply.
Connect power unit to main air supply.
Faulty hand switch assembly.
Replace switch assembly.
Air line connections to power
unit reversed.
Disconnect main air supply, then reverse
the air line connections on crimping unit.
Power unit piston
will not
Faulty foot switch.
extend when actuated.
Improper lubrication.
Loss of power.
Internal seals of crimping unit
worn or damaged.
Americas Headquarters
Lisle, Illinois 60532 U.S.A.
1-800-78MOLEX
amerinfo@molex.com
Solution
Far East North Headquarters
Yamato, Kanagawa, Japan
81-462-65-2324
feninfo@molex.com
Replace switch assembly.
Check for lubrication in the main air supply.
Replace the seals or contact a Molex
Sales Engineer.
Far East South Headquarters
Jurong, Singapore
65-6-268-6868
fesinfo@molex.com
European Headquarters
Munich, Germany
49-89-413092-0
eurinfo@molex.com
Corporate Headquarters
2222 Wellington Ct.
Lisle, IL 60532 U.S.A.
630-969-4550
Fax: 630-969-1352
Visit our Web site at http://www.molex.com
Order No: TM-638160100
Revision: B
Release Date: 02-20-08
Revision Date: 05-28-10
UNCONTROLLED COPY
Page 17 of 17
很抱歉,暂时无法提供与“0638160500”相匹配的价格&库存,您可以联系我们找货
免费人工找货