Unlocking Tool for CMX Receptacle Crimp Terminal
Unlocking
Tool
Application Tooling
Specification Sheet
Order No. 63824-3900
FEATURES
This Tool is for locking and unlocking the TPA from a 70 Way CMX or Euro6 Connector.
SCOPE
Products: CMX Receptacle Connectors
Connector Series No.
34853
34853-0111
34853-0121
34853-0112
34853-0122
Connector Order No.
34853-0113 34853-0114
34853-0123 34853-0124
34853-0115
34853-0125
34853-0116
34853-0126
Unlocking and Opening the (TPA) Secondary Lock
For the CMX receptacle assembly, follow the steps below:
1. Insert the tool into the (2) side slots of the (TPA) secondary lock on each sides until it stops. See Figure 1.
The (2) two catch pivots on the sides of the tool will engage the TPA.
2. Push on the tool until the TPA contacts with the inside edge of the tool and the locking latches click into place.
3. The tool is now secure on the in the TPA. See Figure 2.
4. Gently push the blade engagement slide “IN” until it is about even with the face of the tool.
5. Still holding the front of the tool, pull out until the TPA stops.
6. Remove the tool and check the position of the TPA.
SIDE SLOTS
EXTRACTOR TOOL
TPA LATCH
LOCKING LATCH
Figure 1
BLADE ENGAGEMENT SLIDE
(SHOWN IN THE “OUT” POSITION)
Doc No: ATS-638243900
Revision: A
Release Date: 11-18-13
Revision Date: 11-18-13
UNCONTROLLED COPY
Page 1 of 2
Unlocking Tool for CMX Receptacle Crimp Terminal
TPA LATCH
HOLD HERE TO
OPEN THE TPA
EXTRACTOR
TOOL
BLADE ENGAGEMENT SLIDE
(SHOWN IN THE “IN” POSITION)
HOLD HERE TO RELEASE THE TOOL
FROM THE CONNECTOR
Figure 2
Closing the (TPA) secondary lock
On a CMX receptacle assembly, follow the steps below:
Secondary lock can be closed manually or during the final connector check.
This procedure is done after the insertion of all female terminals.
1. Insert the extractor tool into the (2) side slots of the (TPA) secondary lock on each sides.
2. Pull out with the tool. See Figure 2.
3. Remove the tool and check for placement.
Note:
One of the functions of the secondary lock (TPA) is to detect if any of the terminals are not fully seated in the
cavities. If the secondary lock does not close, reopen the TPA.
Push on the terminals one at a time to make sure they are locked in place.
Close the secondary lock see step 2 and 3.
Check visually the locking latches are in the correct position.
Visit our Web site at http://www.molex.com
Doc No: ATS-638243900
Revision: A
Release Date: 11-18-13
Revision Date: 11-18-13
UNCONTROLLED COPY
Page 2 of 2