Tool Kit for 250 Slip-in Receptacle Terminals
Tool Kit
Order No. 63825-7570
Application Tooling
Specification Sheet
TYPE 4C
Hand Crimp Tool
Order No. 63825-7500
FEATURES
%
%
%
%
A full cycle ratcheting hand tool ensures complete crimps
Ergonomically designed soft handles
Precisely designed crimping profiles with simple contact positioning
Easy handling due to outstanding force ratio
Tool kits are easily installed into the Hand Crimp Tool or the 63816-0300 Power Crimp Head which is installed
into the 63816-0200 (110 V) or the 63816-0250 (220 V) Battery Powered Tool.
Many different Tool kits can be used with a single Battery Powered Tool.
This tool is IPC/WHMA-A-620 Class 2 and RoHS compliant.
SCOPE
Products: .250 Slip-on Receptacle Terminals for 10-14 AWG Wire.
Insulation Diameter
Strip Length
Terminal Insulation
Terminal Terminal Order No. Wire Size
IPC/WHMA-A620 (1)
Series No.
Maximum (2)
Reel Form Only (3) AWG mm²
mm
In.
mm
In.
mm
In.
10 5.25 3.80-4.55 .150-.179
5.30
.209
35725-2710
35725
12 3.30
3.80
.150
5.30
.209
5.20-5.80 .205-.228
35725-2740
14 2.00
N/A
N/A
5.30
.209
(1) To achieve optimum IPC-A620 insulation crimps, use this insulation OD range.
(2) Overall insulation OD specification for terminal.
(3) The terminals above are reeled parts only. Customer to cut off terminal from reel: 0.50 mm (.020”) maximum
DEFINITION OF TERMS
CONDUCTOR
CRIMP HEIGHT
INSULATION
CRIMP
WIRE
SEAM
STRIP LENGTH
BELL MOUTH
FRONT
CUT-OFF TAB
Doc No: ATS-6382575HM Release Date: 05-17-13
Revision:A
Revision Date: 05-17-13
BRUSH
UNCONTROLLED COPY
Page 1 of 8
Tool Kit for 250 Slip-in Receptacle Terminals
CONDITIONS:
After crimping, the conductor profiles should measure the following (See notes below).
Terminal Series No.
35725
Terminal Series No.
35725
Conductor Crimp
Profile
Height
Width
2
AWG mm
mm
In.
mm
In.
A B C
10 5.25 2.60-2.70 .102-.106 3.70-3.90 .146-.154
X
12 3.30 2.15-2.25 .085-.089 3.70-3.90 .146-.154
X
14 2.00 1.90-2.00 .075-.079 3.70-3.90 .146-.154 X
Wire Size
Insulation Crimp
Height
Width
AWG mm2
mm
In.
mm
In.
10 5.25 5.10-5.30 .201-.209 4.85-5.15 .191-.203
12 3.30 4.80-4.95 .189-.195 4.85-5.15 .191-.203
14 2.00 4.50-4.65 .177-.183 4.85-5.15 .191-.203
Wire Size
Pull Force Minimum
N
343
290
190
Lbs
77.1
65.2
42.7
Tool Qualification Notes:
1. Pull Force should be measured with no influence from the insulation crimp.
2. The above specifications are guidelines to an optimum crimp.
Note:
A crimp height chart is provided with this manual as Reference Only. Due to the wide range of wires, strands,
insulation diameters, and durometers, actual crimp height measurements may very slightly. An occasional,
destructive, pull force test should be preformed to check hand tool crimp. Pull Force value must exceed the
minimum pull force specifications listed.
CAUTION: Install only Molex terminals listed above with this tool. Do not crimp hardened objects as damage
can occur to the tool or die.
POWER
CRIMP
HEAD
LIFT UP ON
THE LOCATOR
PUNCHES
M4 X 18 LONG
BHCS
M4 X 10 LONG
BHCS
ANVILS
PRESS DOWN
ON THE BRASS
PIVOT SHAFT
SWING
LOCATOR
OPEN
Figure 1
Figure 2
INSTALLATION
To install the Tool Kit into the Power Crimp Head follow the steps below:
Doc No: ATS-6382575HM Release Date: 05-17-13
Revision:A
Revision Date: 05-17-13
UNCONTROLLED COPY
Page 2 of 8
Tool Kit for 250 Slip-in Receptacle Terminals
Anvils and Punches Installation
1. Insert the Anvils into the bottom slots of the nest. Install the M4 x 10 long BHCS and tighten in place.
2. Insert the Punches into the top slots of the nest. Install the M4 x 18 long BHCS and tighten in place. See
Figure 1.
Locator Installation and Removal
Follow the steps below to install or replace the locator. See Figure 2.
To install the locator
1. Position the locator with the hole over the brass pivot shaft and snap it into place.
To remove the locator
1. Open the crimp hand tool.
2. Swing the existing locator open and away from the hand tool.
3. Firmly press down on the brass pivot shaft with your thumb, while pulling the locator up. Slip the locator off the
top of the brass pivot shaft.
HANDLE
OPEN
TERMINAL
WIRE AGAINST
WIRE STOP
WIRE IN TERMINAL
JAWS
PARTIALLY
CLOSED
LOCATOR
CLOSED
OPERATION
Figure 3
PUSH HERE TO
OPEN WIRE STOP
Open the tool by squeezing the handles together, at
the end of the closing stroke, the ratchet mechanism
will release the handles, and the hand tool will
spring open.
Figure 4
CONDUCTOR
PUNCH
WIRES AGAINST
LOCATOR STOP
LOCATOR
Crimping Terminals
1. Select the desired terminal listed in the
preceding charts.
2. Some terminals with large insulation grips may
interfere with the crimp tooling when swinging
the locator into position. This terminal must
then be loaded into the locator in the
closed/crimp position. See Figure 3.
TERMINAL
CONDUCTOR ANVIL
3. Press down on the wire stop on the locator as
shown in Figure1. Insert the proper terminal
Figure 5
into the proper nest opening. Make sure when
choosing the nest opening, it will correspond with the A, B or C profile on the hand tool.
Doc No: ATS-6382575HM Release Date: 05-17-13
Revision:A
Revision Date: 05-17-13
INSULATION
PUNCH
UNCONTROLLED COPY
WIRE
INSULATION
ANVIL
Page 3 of 8
Tool Kit for 250 Slip-in Receptacle Terminals
4. Insert the proper wire over the terminal.
5. Gently touch the wire stop with the end of the wire. See Figure 4 and 5.
6. Compress the terminal by squeezing the tool handles until the ratchet mechanism cycle has been completed.
Release handles to open the jaws.
7. Remove the crimped terminal from the terminal locator by pressing down on the wire stop and gently pulling on
the wire. The terminal locator can be in either position.
8. Visually inspect the crimped terminal for proper crimp location.
Note: The tamper proof ratchet action will not release the tool until it has been fully closed.
For the Battery Power Tool:
1. Cycle the Battery Power Tool to crimp the
terminal to the wire.
2. Remove the crimped terminal from the
terminal locator by pressing down on the wire
stop and gently pulling on the wire. The
terminal locator can be in either position.
3. Visually inspect the crimped terminal for
proper crimp location.
LUBRICATION
POINTS
(BOTH SIDES)
LIGHT OIL
(EVERY MONTH
OR
5,000 CRIMPS)
Maintenance
It is recommended that each operator of the tool
be made aware of, and responsible for, the
following maintenance steps:
Figure 6B
Figure 6A
1. Remove dust, moisture and other contaminants with a clean brush, or soft, lint-free cloth.
2. Do not use any abrasive materials that could damage the tool.
3. Make certain all pins; pivot points and bearing surfaces in the tool head are protected with a thin coat of high
quality machine oil. Do not oil excessively. This tool was engineered for durability, but like any fine piece of
equipment, it needs cleaning and lubrication for a maximum service life of trouble-free crimping. The use of
light oil, such as 30 weight automotive oil, every 5,000 crimps or monthly, will significantly enhance the tool life
and ensure a stable calibration. See Figure 6A or 6B for lubrication points.
4. Store the tool in a clean and dry area when not in use.
Miscrimps or Jams for Crimp Hand Tools Only (See Figure 9)
Should this tool ever become stuck or jammed in a partially closed position, Do Not force the handles open or
closed. The tool will open easily by rotating the small slotted screw marked with an arrow. See Figure 9.
Warranty
This tool kit is for electrical terminal crimping purposes only. This tool kit is made of the best quality materials. All
vital components are long life tested. All tools are warranted to be free of manufacturing defects for a period of 30
days. Should such a defect occur, we will repair or exchange the tool kit free of charge. This repair or exchange
will not be applicable to altered, misused, or damaged tools.
CAUTION: Molex crimp specifications are valid only when used with Molex terminals and tooling.
Doc No: ATS-6382575HM Release Date: 05-17-13
Revision:A
Revision Date: 05-17-13
UNCONTROLLED COPY
Page 4 of 8
Tool Kit for 250 Slip-in Receptacle Terminals
CAUTIONS
1. Manually powered hand tools are intended for low volume or field repair. This tool is NOT intended for
production use. Repetitive use of this tool should be avoided.
2. Insulated rubber handles are not protection against electrical shock.
3. Wear eye protection at all times.
4. Use only the Molex terminals specified for crimping with this tool.
CAUTION: Repetitive use of this tool should be avoided.
Certification
Molex does not certify or re-certify commercial grade hand tools but rather supplies the following guidelines for
customers to re-certify hand tools.
%
This tool is qualified to pull force only. To re-certify, crimp a terminal to a wire, which has been stripped
12.7mm (1/2”) long, so there is no crimping of the insulation. Pull the terminal and wire at a rate no faster than
25mm (1.00”) per minute. See the Molex web site for the Quality Crimp Handbook for more information on pull
testing.
% When the hand tool is no longer capable of achieving minimum pull force, it should be taken out of service and
replaced.
% This tool is very difficult to disassemble and reassemble. Customer repair is not recommended.
Doc No: ATS-6382575HM Release Date: 05-17-13
Revision:A
Revision Date: 05-17-13
UNCONTROLLED COPY
Page 5 of 8
Tool Kit for 250 Slip-in Receptacle Terminals
The chart below shows all applications for this Tool Kit.
Tool Kit
Order No.
Tool
Tool
Power Head
Adapter
Figure
Order no.
Description
Order No.
Description
No.
63810-1050 Hand Crimp Frame (Short)
N/A
N/A
9
63810-1000 Hand Crimp Frame (Long)
N/A
N/A
9
63825-7570
63816-0200 Battery Power Tool (110 V) 63816-0300 Power Crimp Head
10
63816-0250 Battery Power Tool (220 V) 63816-0300 Power Crimp Head
10
Applications for the Tool Kit
Hand Crimp Tool
Battery Powered Tool
POWER
CRIMP
HEAD
TOOLING KIT
TOOLING KIT
BATTERY
POWERED
TOOL
LOCKING PINS
HAND CRIMP
FRAME LONG
AND SHORT
Figure 7
Figure 8
WARNING: NEVER operate service, install tool kits, or adjust the Power Crimp Head without proper
instruction and without first reading and understanding the instructions in the proper Manual or
Specification Sheet. See Chart above for the correct Manual or Specification Sheet.
WARNING: NEVER install tooling or service this tool while it is into any power source. Make sure the
power is turned off.
CAUTION: Keep fingers away from the crimping area when operating this tool. It may cause severe injury.
CAUTION: Wear safety glasses when operating or serving this tool.
Doc No: ATS-6382575HM Release Date: 05-17-13
Revision:A
Revision Date: 05-17-13
UNCONTROLLED COPY
Page 6 of 8
Tool Kit for 250 Slip-in Receptacle Terminals
HAND TOOL PARTS LIST
Item Number
1
2
3
4
Order Number
63810-1000
63825-7570
63811-4773
63825-7575
Description
Hand Crimp Frame (Long)
Tool Kit with Locator
Locator Base
Locator (only)
M4 X 8mm
LONG BHCS
Quantity
1
1
1
REF
1
3
RATCHET
RELEASE SCREW
2
WITH TOOL KIT
4
LOCATOR ONLY
M4 X 10mm
LONG BHCS
M4 X 18mm
LONG BHCS
Figure 9
2
Doc No: ATS-6382575HM Release Date: 05-17-13
Revision:A
Revision Date: 05-17-13
UNCONTROLLED COPY
Page 7 of 8
Tool Kit for 250 Slip-in Receptacle Terminals
POWER HEAD PARTS LIST
Item
1
2
Order No
63816-0300
63825-7570
Engineering No.
63816-0300
63825-7570
Description
Power Crimp Head
Tool Kit with Locator
Quantity
1
1
2
1
1
M4 by 8 Long
BHCS
M4 by 18 Long
BHCS
M4 by 10 Long
BHCS
2
Figure 10
Visit our Web site at http://www.molex.com
Doc No: ATS-6382575HM Release Date: 05-17-13
Revision:A
Revision Date: 05-17-13
UNCONTROLLED COPY
Page 8 of 8
很抱歉,暂时无法提供与“0638257500”相匹配的价格&库存,您可以联系我们找货
免费人工找货