Air Feed Mylar Tape Applicator
Mini-Mac Applicator
Application Tooling Specification
Air Feed-Mylar Tape
Part No. 63885-3500
FEATURES
Directly adapts to most crimp presses and automatic wire processors
Applicator designed to industry-standard mounting and shut height of 135.80mm (5.346")
Conductor and insulation rings allow quick adjustment for conductor and insulation crimp height change
Quick set-up time; plus the crimp height, track and feed adjustments can be set without removing the applicator from the crimp press
SCOPE
Products: Nylon closed end connector 12-22 AWG
Testing
Mechanical
The tensile test, or pull test, is a means of evaluating the mechanical properties of the crimped connections. The following chart shows
the UL and government specifications (MIL-T-7928) for various wire sizes. The tensile strength is shown in pounds and indicates the
minimum acceptable force to break or separate the terminal from the conductor.
Color Code
Yellow
Yellow
Red
Red
Red
Blue
Blue
Yellow
Yellow
Red
Blue
Wire Size (AWG)
26
24
22
20
18
16
14
12
10
8
6
*UL - 486 A
3
5
8
13
20
30
50
70
80
90
100
*UL – 486 C
N/A
N/A
8
10
10
15
25
35
40
45
50
*UL – 310
N/A
N/A
8
13
20
30
50
70
80
N/A
N/A
*Military Class 2
7
10
15
19
38
50
70
110
150
225
300
*UL - 486 A - Terminals (Copper conductors only)
*UL - 486 C - Butt Splices, Parallel Splices, Closed End Connectors, and Wire Nuts
*UL - 310 - Quick Disconnects, Flag and Couplers
*Military Class 2- Military Approved Terminals only as listed
Doc No. 63885-3500
Revision: D
Release Date: 12-09-04
Revision Date: 10-04-05
UNCONTROLLED COPY
Page 1 of 7
Air Feed Mylar Tape Applicator
Product List
The following is a partial list of the product order numbers and their specifications that this tool is designed to run. Updates to this list are
available on www.molex.com.
Terminal No.
Terminal Eng. No.
19160-0071
NC-2212
Wire Size
AWG
mm²
12 - 22 3.30 – 0.35
Wire combinations
See Chart 1
OPERATION
Strip Length
mm
In.
9.52 .375
3/8 “
Wire Preparation
Pre-twisted wire not required for OEM applications. For Solid (OEM only)
strip leads to 9.5mm (3/8”). Insert into connector and crimp.
For stranded wire, strip leads to approximately 9.5mm (3/8”). Twist the wire combination even and tight. Trim stripped pretwisted area to 9.5mm (3/8”) and insert into connector and crimp. For more information follow the Quality Crimping Handbook,
(Document no. 64016-0065).
Chart 1
Wire Combinations for Nylon- Insulated Closed End Connectors
Part No. 191600071 (NC-2212)
Wire Gauge (AWG)
Wire Type
Rating
14
16
18
20
22
Stranded or Solid
1
1
UL & CSA
Stranded or Solid
1
1
UL & CSA
Stranded or Solid
1
2
UL & CSA
Stranded or Solid
1
1
1
UL & CSA
Stranded or Solid
1
1
2
UL & CSA
Stranded or Solid
1
1
1
UL & CSA
Stranded or Solid
1
1
2
UL & CSA
Stranded or Solid
1
1
3
UL & CSA
Stranded or Solid
1
1
UL & CSA
Stranded or Solid
1
2
UL & CSA
Stranded or Solid
1
3
UL & CSA
Stranded or Solid
1
1
UL & CSA
Stranded or Solid
1
2
CSA
Stranded or Solid
1
3
CSA
Stranded or Solid
1
4
CSA
Stranded or Solid
1
1
1
1
CSA
Stranded or Solid
3
UL & CSA
Stranded or Solid
2
UL & CSA
Stranded or Solid
2
1
UL & CSA
Stranded only
2
2
UL & CSA
Stranded or Solid
2
1
UL & CSA
Stranded or Solid
2
2
UL & CSA
Stranded or Solid
2
1
UL & CSA
Stranded or Solid
2
2
UL & CSA
Stranded or Solid
2
3
UL & CSA
Stranded or Solid
2
1
1
UL & CSA
Stranded or Solid
2
1
1
UL & CSA
Stranded or Solid
2
1
1
UL & CSA
Stranded or Solid
1
1
2
UL & CSA
Stranded or Solid
1
1
UL & CSA
Doc No. 63885-3500
Revision: D
Release Date: 12-09-04
Revision Date: 10-04-05
Wire Combinations for Nylon- Insulated Closed End Connectors
Part No. 191600071 (NC-2212)
Wire Type
Wire Gauge (AWG)
Rating
14
16
18
20
22
Stranded or Solid
1
1
UL & CSA
Stranded or Solid
1
2
UL & CSA
Stranded or Solid
1
3
UL & CSA
Stranded or Solid
1
1
UL & CSA
Stranded or Solid
1
2
UL & CSA
Stranded or Solid
1
3
UL & CSA
Stranded or Solid
1
4
UL & CSA
Stranded or Solid
1
1
UL & CSA
Stranded or Solid
1
2
UL & CSA
Stranded or Solid
1
3
UL & CSA
Stranded or Solid
1
4
UL & CSA
Stranded or Solid
1
5
UL & CSA
Stranded or Solid
1
2
1
UL & CSA
Stranded or Solid
1
2
1
UL & CSA
Stranded or Solid
1
2
2
UL & CSA
Stranded or Solid
1
1
1
UL & CSA
Stranded or Solid
1
2
1
UL & CSA
Stranded or Solid
1
1
2
UL & CSA
Stranded Only
5
UL only
Stranded or Solid
4
UL & CSA
Stranded or Solid
4
1
UL & CSA
Stranded or Solid
4
1
UL & CSA
Stranded or Solid
3
UL & CSA
Stranded or Solid
3
1
UL & CSA
Stranded or Solid
3
2
UL & CSA
Stranded or Solid
3
1
UL & CSA
Stranded or Solid
3
2
UL & CSA
Stranded or Solid
3
3
UL & CSA
Stranded or Solid
3
1
1
UL & CSA
Stranded or Solid
2
UL & CSA
UNCONTROLLED COPY
Page 2 of 7
Air Feed Mylar Tape Applicator
Wire Combinations for Nylon- Insulated Closed End Connectors
Part No. 191600071 (NC-2212)
Wire Gauge (AWG)
Wire Type
Rating
14
16
18
20
22
Stranded or Solid
2
1
UL & CSA
Stranded or Solid
2
2
UL & CSA
Stranded or Solid
2
3
UL & CSA
Stranded or Solid
2
1
UL & CSA
Stranded or Solid
2
2
UL & CSA
Stranded or Solid
2
3
UL & CSA
Stranded or Solid
2
1
1
UL & CSA
Stranded or Solid
2
2
1
UL & CSA
Stranded or Solid
2
3
1
UL & CSA
Stranded or Solid
2
1
2
UL & CSA
Stranded or Solid
2
1
3
UL & CSA
Stranded or Solid
1
1
UL & CSA
Stranded or Solid
1
2
UL & CSA
Stranded or Solid
1
3
UL & CSA
Stranded or Solid
1
4
UL & CSA
Stranded or Solid
1
5
UL & CSA
Stranded or Solid
1
1
UL & CSA
Stranded or Solid
1
2
UL & CSA
Stranded or Solid
1
3
UL & CSA
Stranded or Solid
1
4
UL & CSA
Stranded or Solid
1
5
UL & CSA
Stranded or Solid
1
1
1
UL & CSA
Stranded or Solid
1
2
1
UL & CSA
Stranded or Solid
1
3
1
UL & CSA
Stranded or Solid
1
4
1
UL & CSA
Stranded or Solid
1
1
2
UL & CSA
Stranded or Solid
1
1
3
UL & CSA
Stranded or Solid
1
1
4
UL & CSA
Doc No. 63885-3500
Revision: D
Release Date: 12-09-04
Revision Date: 10-04-05
Wire Combinations for Nylon- Insulated Closed End Connectors
Part No. 191600071 (NC-2212)
Wire Type
Wire Gauge (AWG)
Rating
14
16
18
20
22
Stranded or Solid
1
2
2
UL & CSA
Stranded or Solid
1
2
3
UL & CSA
Stranded or Solid
1
3
2
UL & CSA
Stranded or Solid
6
UL & CSA
Stranded or Solid
5
UL & CSA
Stranded or Solid
5
1
UL & CSA
Stranded or Solid
4
UL & CSA
Stranded or Solid
4
1
UL & CSA
Stranded or Solid
4
2
UL & CSA
Stranded or Solid
3
UL & CSA
Stranded or Solid
3
1
UL & CSA
Stranded or Solid
3
2
UL & CSA
Stranded or Solid
3
3
UL & CSA
Stranded or Solid
2
UL & CSA
Stranded or Solid
2
1
UL & CSA
Stranded or Solid
2
2
UL & CSA
Stranded or Solid
2
3
UL & CSA
Stranded or Solid
2
4
UL & CSA
Stranded or Solid
1
1
UL & CSA
Stranded or Solid
1
2
UL & CSA
Stranded or Solid
1
3
UL & CSA
Stranded or Solid
1
4
UL & CSA
Stranded or Solid
1
5
UL & CSA
Stranded or Solid
6
UL & CSA
Stranded or Solid
5
UL & CSA
Stranded or Solid
4
UL & CSA
Stranded or Solid
3
UL & CSA
Stranded or Solid
2
UL & CSA
UNCONTROLLED COPY
Page 3 of 7
Air Feed Mylar Tape Applicator
Tool Calibration
To recalibrate this Applicator, make sure the power is completely shut off
on the press.
1. The Mini-Mac applicator must be properly installed in the press.
2. Crimping dies must be properly installed in the Mini-Mac applicator.
3. The recommended method of measuring the crimp height of the
conductor dies is the soft metal slug method, (See Figure 4).
4. The slug must have a diameter 0.51mm (.020”) larger than the “X”
No Go dimension before crimping.
5. Place the soft metal slug (solder) into the nest of the bottom die and
crimp (by hand cycling the press) similar to a terminal. The crimp
height can be measured with a blade type micrometer or dial caliper,
(Dimension “X”).
6. Adjustment of the crimp height can be accomplished by indexing the
conductor cam. The letter “A” gives the loosest position and “K” gives
the tightest position. A total adjustment of 0.50mm (.020”) can be
achieved by adjusting the conductor cam.
CONDUCTOR
CRIMP DIE
USE SOFT METAL
SLUG METHOD
E2
“X” CRIMP
HEIGHT
E1
CRIMP PROFILE
Use soft metal slug (solder) method to measure
the “X” dimension. Verify tooling crimp height
calibration by referring to the Go/No Go
dimensions shown in the chart below.
Figure 2
Note: If the crimp height is too tight on the setting “A”, check the shut height of the press. See the Industrial Mini-Mac Applicator
Manual Section 2.1 for adjustments.
CRIMP SPECIFICATIONS
Wire Size
AWG
mm²
12-22
0.20
“X” Dimension Conductor Crimp
Mean
Go
No Go
In
mm
In
mm
In
mm
.102 2.59 .099 2.51 .106 2.69
Pull Force Min.
Lbs
N
Pull Force should be measured with no influence from the insulation crimp. The above specifications are guidelines to an optimum
crimp.
Doc No. 63885-3500
Revision: D
Release Date: 12-09-04
Revision Date: 10-04-05
UNCONTROLLED COPY
Page 4 of 7
Air Feed Mylar Tape Applicator
PARTS LIST
Mini-Mac Applicator 63885-3500
Item Order No Engineering No.
Description
Quantity
Perishable Tooling
63885-3570
63885-3570
Tool Kit (All “Y” Items)
REF
1
63465-0032
63465-0032
Conductor Punch
1Y
2
63464-0031
63464-0031
Conductor Anvil
1Y
Other Components (Ref. 50050)
31 63466-0912
63466-0912
Anvil Mount
1
32 63466-0913
63466-0913
Terminal Support
1
33 63443-0021
63443-0021
Lower Tooling Key
1
42 63466-0921
63466-0921
Terminal Stripping Blade
1
51 63600-1290
63600-1290
Washer
1
52 63890-0866
63890-0866
Collar-6.4 Lg.
1
53 63890-0867
63890-0867
Collar-9.5 Lg.
1
Frame
81 63801-3301
63801-3301
Air Feed Applicator Frame Head
REF
82 63801-3281
63801-3281
Base
REF
83 63801-5850
63801-5850
Track Assembly
REF
84 63801-3390
63801-3390
Air Kit
REF
Hardware
91
N/A
N/A
M3 by 12 Lg SHCS
1**
92
N/A
N/A
M4 by 10 Lg SHCS
2**
93
N/A
N/A
M4 by 16 Lg. SHCS
1**
94
N/A
N/A
M4 by 45 Lg. SHCS
1**
95
N/A
N/A
M8 by 30 Lg. BHCS
1**
96
N/A
N/A
3mm by 6 Lg. Roll Pin
1**
** Available from an industrial supply company such as MSC (1-800-645-7270).
Note: Crimp profiles used in 63885-3500 are equivalent to 19288-0239/ATP-NC-2212 (UL file number E32244).
Doc No. 63885-3500
Revision: D
Release Date: 12-09-04
Revision Date: 10-04-05
UNCONTROLLED COPY
Page 5 of 7
Air Feed Mylar Tape Applicator
Assembly Drawing
81
1
52
51
81
53
95
42
92
(2)
32
83
31
84
2
91
93
82
96
94
33
Figure 5
Doc No. 63885-3500
Revision: D
Release Date: 12-09-04
Revision Date: 10-04-05
UNCONTROLLED COPY
Page 6 of 7
Air Feed Mylar Tape Applicator
NOTES
1.
2.
3.
4.
5.
Molex recommends an extra perishable tooling kit be maintained at your facility.
Verify tooling alignment by manually cycling the press with applicator before crimping under power. Check that all screws are
tight.
Slugs, terminals, dirt, and oil should be kept clear of work area.
Wear safety glasses at all times.
For recommended maintenance refer to the Mini-Mac Applicator Manual (Document no. 63880-0000).
CAUTION: This applicator should only be used in a press with a shut height of 135.80 mm (5.346”). Tooling damage could
result at a lower setting.
CAUTION: To prevent injury, never operate this applicator without the guards supplied with the press or wire-processing
machine in place. Reference the press or wire processing manufacturer’s instruction manual.
CAUTION: Molex crimp specifications are valid only when used with Molex terminals, applicators and tooling.
Contact Information
For more information on Molex application tooling please contact Molex at 1-800-786-6539.
Molex Application Tooling Group
1150 E. Diehl Road
Naperville, IL 60563
Tel: (630) 969-4550
Fax: (630) 505-0049
Visit our Web site at http://www.molex.com
Doc No. 63885-3500
Revision: D
Release Date: 12-09-04
Revision Date: 10-04-05
UNCONTROLLED COPY
Page 7 of 7
很抱歉,暂时无法提供与“0638853500”相匹配的价格&库存,您可以联系我们找货