1200850011

1200850011

  • 厂商:

    MOLEX10(莫仕)

  • 封装:

    -

  • 描述:

    CONN PLUG FMALE 4POS GOLD SCREW

  • 数据手册
  • 价格&库存
1200850011 数据手册
Achieve non-arcing connections in a one-step installation process with the Brad® Ultra-Lock® (M12) EX Connection System, designed for industrial automation use in Class I, Division 2 and Zone 2 hazardous areas Brad Ultra-Lock (M12) EX cordsets and receptacles provide process automation installers a safe, quick connection interface for instrumentation and control devices in potentially explosive and hazardous areas. The patented push-to-lock technology provides a simple and secure operatorindependent connection. Ultra-Lock connectors are designed to eliminate connector-related intermittent signals in the harshest environments. The Ultra-Lock (M12) EX connector has been designed with an integral isolating ring that limits the access to the release mechanism of the connector. The connector can be pushed on, but requires a screwdriver to disconnect. With this characteristic, the connection point is considered normally non-arcing and, therefore, suitable for use in a hazardous Class I, Division 2 and Zone 2 classified areas. Brad® Ultra-Lock® (M12) EX Connection System for Zone 2 Hazardous Locations 120614  Single Ended Cordsets 120613  Double Ended Cordsets 120615 Receptacles Features and Benefits Certified Class I, Division 2 and Zone 2 cordsets and receptacles Meets safety requirements for hazardous usage areas Integral isolating ring with access notch design on cordset Ensures a code-compliant connection without additional installation steps Pre-wired molded connections with polarized positioning on cordset Provides excellent performance in high vibration applications; provides fast installation eliminating wiring termination errors Push-to-lock connector design Provides a quick, secure and reliable connection Radial sealed Provides IP67 / IP68 / IP69K watertight connection for temporary submersion; consistent operator-independent seal Brad® Ultra-Lock® (M12) EX Connection System for Zone 2 Hazardous Locations Left: Female Single Ended (Series 120614) Right: Male Single Ended (Series 120614) Specifications Reference Information FM File No.: Certificate 3039279 (for US) and 3039279C (for Canada) C  lass I, Division 2, Groups A, B, C  , D T6 when installed per control drawing SD-120614-999 Class1, Zone 2, Aex nA IIC T6 w  hen installed per control CSA File No.: Certificate 2251424 (for Canada) C  lass I, Division 2, Groups A, B, C, D Class I, Zone 2, IIC Note: for FM and CSA Certificates see product specification PS-120614-001 Electrical Voltage (max.): 125V – 3 and 4 Pole 32V – 5 Pole Current (max.): 4.0A Contact Resistance: < 5mOhms Environmental Protection: IP67 / IP68 / IP69K Operating Temperature: -20 to +40°C Physical Isolating Ring: Stainless Steel 303 Coupling Nut: Nickel Plated Brass O-ring: VITON Contact Carrier: PUR Connector Body: TPE Contact: Copper Alloy with Gold over Nickel plating Brad® Ultra-Lock® (M12) EX Connection System for Zone 2 Hazardous Locations Cables K05 – Yellow TPE jacket, 22 AWG PVC conductors, 300V, UL PLTC-ER, -40 to +105°C K03 – Yellow TPE jacket, 18 AWG PVC conductors, 300V, UL PLTC-ER, -40 to +105°C C02 – Yellow thermostat rubber cable, 18 AWG EPDM conductor 300V, SJOOW (UL) – SJOW (CSA), -50 to +105°C A18 – PVC insulated Conductors, 22 AWG, 300V, 19x#34 stranding, UL 1061, 80°C A16 – PVC insulated Conductors, 18 AWG, 300V, 19x#34 stranding, UL 1061, 80°C Additional Product Information How it works Mate/Disconnect Sequence* 1. Align keyways and push-to-lock connector to make connection 2. After mated connector is locked in place, there is no possibility to disconnect by hand 3. Insert #1 standard screwdriver into access notch, twist-to-release Ultra-Lock mechanism and pull at the same time to disconnect 4. The connector is now disconnected from the receptacle *W  ARNING – Explosion Hazard - DO NOT CONNECT OR DISCONNECT WHILE ENERGIZED 1. Push-to-mate connector Integral Isolating Ring Access notch Ultra-Lock Receptacle #1 Screwdriver required to release latch or disconnect 2. Integral isolating ring does not allow pull-to-disconnect 3. Insert tool, twist and pull 4. Disconnect Brad® Ultra-Lock® (M12) EX Connection System for Zone 2 Hazardous Locations Ordering Information Single-Ended Cordsets, Female Female Straight Pole Current (max.) Voltage (max.) 3 4 4.0A 5 125 32 Cable Type Cable Jacket (Cable Code) Wire Size (AWG) Length (m) *Certifications Eng. No. Order No. Female 90° Eng. No. Order No. PLTC-ER TPE (K05) 22 (1) LW03000K05M020 120614-0001 LW03001K05M020 120614-0007 SJOOW RUBBER (C02) 18 (1), (2) LW03000C02M020 120614-4001 LW03001C02M020 120614-4005 TPE (K05) 22 PLTC-ER TPE (K03) SJOOW RUBBER (C02) PLTC-ER TPE (K03) 2 18 LW04000K05M020 120614-0005 LW04001K05M020 120614-0008 LW04000K03M020 120614-2001 LW04001K03M020 120614-2005 (1), (2) LW04000C02M020 120614-4002 LW04001C02M020 120614-4006 (1) LW05000K03M020 120614-2002 LW05001K03M020 120614-2006 (1) Single-Ended Cordsets, Male Male Straight Pole Current (max.) Voltage (max.) 3 4 4.0A 5 125 32 Cable Type Cable Jacket (Cable Code) Wire Size (AWG) PLTC-ER TPE (K05) 22 SJOOW RUBBER (C02) 18 TPE (K05) 22 PLTC-ER TPE (K03) SJOOW RUBBER (C02) PLTC-ER TPE (K03) Length (m) 2 18 *Certifications Male 90° Eng. No. Order No. Eng. No. Order No. (1) LW03006K05M020 120614-0003 LW03007K05M020 120614-0009 (1), (2) LW03006C02M020 120614-4003 LW03007C02M020 120614-4007 LW04006K05M020 120614-0006 LW04007K05M020 120614-0010 LW04006K03M020 120614-2003 LW04007K03M020 120614-2007 (1), (2) LW04006C02M020 120614-4004 LW04007C02M020 120614-4008 (1) LW05006K03M020 120614-2004 LW05007K03M020 120614-2008 (1) Double-Ended Cordsets Female Straight to Male Straight Pole Current (max.) Voltage (max.) 3 4 4.0A 5 125 Cable Type Cable Jacket (Cable Code) Wire Size (AWG) Length (m) *Certifications Eng. No. Order No. Pole 4 5 4.0A TPE (K05) 22 (1) LWLW3030K05M010 120613-0001 LWLW3031K05M010 120613-0005 RUBBER (C02) 18 (1), (2) LWLW3030C02M010 120613-4001 LWLW3031C02M010 120613-4005 TPE (K05) 22 LWLW4030K05M010 120613-0002 LWLW4031K05M010 120613-0006 LWLW4030K03M010 120613-2001 LWLW4031K03M010 120613-2005 (1), (2) LWLW4030C02M010 120613-4002 LWLW4031C02M010 120613-4006 (1) LWLW5030K03M010 120613-2002 LWLW5031K03M010 120613-2006 PLTC-ER TPE (K03) RUBBER (C02) 32 PLTC-ER TPE (K03) Voltage (max.) Cable Type Cable Jacket (Cable Code) 125 32 Order No. SJOOW SJOOW 3 Eng. No. PLTC-ER 2 18 (1) Female Straight to Male 90° Current (max.) Female 90° to Male Straight Wire Size (AWG) Length (m) *Certifications Eng. No. Order No. Female 90° to Male 90° Eng. No. Order No. PLTC-ER TPE (K05) 22 (1) LWLW3032K05M010 120613-0003 LWLW3033K05M010 120613-0007 SJOOW RUBBER (C02) 18 (1), (2) LWLW3032C02M010 120613-4003 LWLW3033C02M010 120613-4007 TPE (K05) 22 LWLW4032K05M010 120613-0004 LWLW4033K05M010 120613-0008 PLTC-ER TPE (K03) SJOOW RUBBER (C02) PLTC-ER TPE (K03) 18 2 (1) LWLW4032K03M010 120613-2003 LWLW4033K03M010 120613-2007 (1), (2) LWLW4032C02M010 120613-4004 LWLW4033C02M010 120613-4008 (1) LWLW5032K03M010 120613-2004 LWLW5033K03M010 120613-2008 * (1) Certified for US installations (2) Certified for Canadian installations Brad® Ultra-Lock® (M12) EX Connection System for Zone 2 Hazardous Locations Ordering Information Female Receptacles Pole Current (max.) 3 4 4.0A 5 Voltage (max.) Wire Type Wire Size (AWG) Length (m) ½” - 14NPT Front Panel Mount ¼” - 18NPT Front Panel Mount Eng. No. Order No. Eng. No. Order No. LWR3000A18C300 120615-0001 LWR3A00A18C300 120615-0004 PVC UL1061 (A18) 22 Voltage (max.) Wire Type Wire Size (AWG) Length (m) ½” - 14NPT Front Panel Mount ¼” - 18NPT Front Panel Mount Eng. No. Eng. No. 125 PVC UL1061 (A18) LWR3006A18C300 120615-1001 LWR3A06A18C300 120615-1004 22 0.305 LWR4006A18C300 120615-1002 LWR4A06A18C300 120615-1005 LWR5006A18C300 120615-1003 LWR5A06A18C300 120615-1006 125 32 0.305 LWR4000A18C300 120615-0002 LWR4A00A18C300 120615-0005 LWR5000A18C300 120615-0003 LWR5A00A18C300 120615-0006 Male Receptacles Pole Current (max.) 3 4 5 4.0A 32 Order No. Order No. Applications Field Instrumentation and Control Devices in Class I, Division 2 and Zone 2 Hazardous areas: –O  il and Gas Production and Transportation Facilities –O  il Refineries –P  etrochemical Complexes –W  aste Water Processing Plants –P  harmaceutical Manufacturing –F  ood and Beverage Processing www.molex.com/link/bradultralockex.html Order No. 987650-6781 Rev. 2 Printed in USA/KC/2012.08 ©2012 Molex
1200850011 价格&库存

很抱歉,暂时无法提供与“1200850011”相匹配的价格&库存,您可以联系我们找货

免费人工找货
1200850011
    •  国内价格
    • 7+231.07115
    • 13+226.36775
    • 25+221.84571

    库存:9