E_T-1W & F_T-1W Series
1W, FIXED INPUT, ISOLATED & UNREGULATED DUAL/SINGLE OUTPUT DC-DC CONVERTER
m ulti-country patent protection RoHS FEATURES
Small Footprint SMD Package Style 3KVDC Isolation Temperature Range: -40°C to +85°C No Heat sink Required Industry Standard Pinout Internal SMD construction No External Component Required RoHS Compliance
PRODUCT PROGRAM
Input P art Number F0303T-1W F0305T-1W F0505T-1W F0509T-1W F0512T-1W F0515T-1W E0505T-1W E0509T-1W E0512T-1W 5 4.5-5.5 Voltage (VDC) Nominal 3.3 Range 3.0-3.6 Voltage (VDC) 3.3 5 5 9 12 15 ±5 ±9 ±12 ±15 5 9 12 12 10.8-13.2 15 ±5 ±9 ±12 ±15 Output Current (mA) Max 304 200 200 110 84 66 ±100 ±55 ±42 ±33 200 110 84 66 ±100 ±55 ±42 ±33 Min 30 20 20 11 9 7 ±10 ±6 ±5 ±4 20 11 9 7 ±10 ±6 ±5 ±4 73 75 70 76 78 79 71 77 78 79 69 73 73 74 71 73 74 75 UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL Efficiency Certificate (%, Typ.)
APPLICATIONS
The E_T-1W&F_T-1W Series are specially designed for applications where a group of polar power supplies are isolated from the input power supply in a distributed power supply system on a circuit board. These products apply to: 1) W here the voltage of the input power supply is fixed (voltage variation ≤ ±10%); 2) W here isolation is necessary between input and output (isolation voltage ≤3000VDC); 3) W here the regulation of the output voltage and the output ripple noise are not demanding. Such as: purely digital circuits, ordinary low frequency analog circuits, and IGBT power device driving circuits.
E0515T-1W F1205T-1W F1209T-1W F1212T-1W F1215T-1W E1205T-1W E1209T-1W E1212T-1W E1215T-1W
Note: The E_T-W2/F_T-W2 series also are available in our company.
ISOLATION SPECIFICATIONS
Item Isolation voltage Isolation resistance Test Conditions Tested for 1 minute and 1mA max Test at 500VDC Min 3000 1000 Typ Max Units VDC MΩ
OUTPUT SPECIFICATIONS
Item Output power Test Conditions For Vin change of 1%(3.3V output) For Vin change of 1%(Others output) 10% to 100% load 3.3V output 15 12.8 8.3 6.8 6.3 10% to 100% load 5V output Load regulation 10% to 100% load 9V output 10% to 100% load 12V output 10% to 100% load 15V output Output voltage accuracy Temperature drift Output ripple &Noise* 100% full load 20MHz Bandwidth E_T-1W series F_T-1W series 50 75 100 Min 0.1 Typ. Max 1 ±1.5 ±1.2 20 15 10 10 10 0.03 75 100 % /°C mVp-p KHz % Units W
MODEL SELECTION
Rated Power Package Style Output Voltage Input Voltage Product Series
Line regulation
See tolerance envelope graph
MORNSUN Science& Technology co.,Ltd.
Address: 2th floor 6th building, Huangzhou Industrial District, Guangzhou, China Tel: 86-20-38601850 Fax:86-20-38601272 Http://www.mornsun-power.com
Switching frequency
Full load, nominal input
*Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power Converter section, application notes. Note: 1. All specifications measured at TA=25°C, humidity220 oC ) 2 6 0o C
1 0 Sec Max
2 2 0o C
Vin (VDC) 3 .3/5 12 -
Cin ( uF) 4.7 2.2 -
Single Vout ( VDC) 5 9 12 15
Cout (uF) 10 4.7 2.2 1
Dual Vout (VDC) ±3.3/5 ±9 ±12 ±15
Cout ( uF) 4.7 2.2 1 1
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
First Angle Projection
RECOMMENDED FOOTPRINT Top view,grid:2.54*2.54mm(0.1*01inch) 7.50 (0.295) 11.20 (0.441) 1211 10 87 Top View Sigle/Dual output
It ’s not recommended to connect any external capacitor in t he application field with less than 0.5 watt output.
Output Voltage Regulation and Over- voltage Protection Circuit The simplest device for output voltage regulation, over-voltage and over-current protection is a linear voltage regulator with overheat protection that is connected to the i nput or output end in series (Figure2).
Dual O u tput Vi n GND
R EG REG
2.00 (0.079) 8 7
2.54 (0.100)
0.60 (0.024)
12 11 10
+Vout 0V
DC DC
REG
-Vout
6.50 (0.254) 6.25 (0.244)
Side View 4.25 (0.166) FOOTPRINT DETAILS Pin 1 2 Single GND Vin 0V
(0.039)
Single O utput Vi n
R EG REG
+Vout
1.30
Dual GND Vin 0V -Vo +Vo NC
GND
DC DC
0V
(Figure2) Overload Protection Under normal operating conditions, the output circuit of t hese products has no protection against overload. The simplest method is to connect a self-recovery fuse in series at the input end or add a circuit breaker to the circuit. No parallel connection or plug and play.
NC 8 +Vo Others NC NC:No Connection
Note: Unit:mm(inch) Pin section:0.50*0.30mm(0.020*0.012inch) Pin section tolerances: 0.10mm( 0.004inch) General tolerances: 0.15mm( 0.006inch)
MORNSUN reserves the copyright
Specifications subject to change without notice.
F_T-1W &E_T-1W
A/1-2008
Page 2 of 2
很抱歉,暂时无法提供与“F0505T-1W”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+13.485
- 30+13.02
- 100+12.09
- 500+11.16
- 1000+10.695