WRA_SP-3W & WRB_SP-3W Series
3W, WIDE INPUT, IAOLATED & REGULATED DUAL/SINGLE OUTPUT DIP DC-DC CONVERTER
multi-country patent protection RoHS FEATURES
W ide (2:1) input range Efficiency up to 82% Short circuit protection(automatic recovery) Operating temperature: -40°C to +85°C Internal SMD construction 1.5KVDC Isolation Metal shielding package No Heat sink required No external component required Industry standard Pinout MTBF>1,000,000 hours RoHS Compliance
PRODUCT PROGRAM
Part Number W RA0505SP-3W W RA0509SP-3W W RA0512SP-3W W RA0515SP-3W W RB0505SP-3W W RB0509SP-3W W RB0512SP-3W W RB0515SP-3W W RA1205SP-3W W RA1209SP-3W W RA1212SP-3W W RA1215SP-3W W RB1205SP-3W W RB1209SP-3W W RB1212SP-3W W RB1215SP-3W W RB1224SP-3W W RA2405SP-3W W RA2409SP-3W W RA2412SP-3W W RA2415SP-3W W RB2405SP-3W W RB2409SP-3W W RB2412SP-3W W RB2415SP-3W W RB2424SP-3W W RA4805SP-3W W RA4809SP-3W W RA4812SP-3W W RA4815SP-3W W RB4805SP-3W W RB4809SP-3W W RB4812SP-3W W RB4815SP-3W W RB4824SP-3W Input Voltage (VDC) Nominal Range M ax* Voltage (VDC) ±5 ±9 ±12 ±15 5 9 12 15 ±5 ±9 ±12 ±15 5 9 12 15 24 ±5 ±9 ±12 ±15 5 9 12 15 24 ±5 ±9 ±12 ±15 5 9 12 15 24 Output Current Max ±300 ±166 ±125 ±100 600 333 250 200 ±300 ±166 ±125 ±100 600 333 250 200 125 ±300 ±166 ±125 ±100 600 333 250 200 125 ±300 ±166 ±125 ±100 600 333 250 200 125 (mA) Min ±30 ±16 ±12 ±10 60 33 25 20 ±30 ±16 ±12 ±10 60 33 25 20 12 ±30 ±16 ±12 ±10 60 33 25 20 12 ±30 ±16 ±12 ±10 60 33 25 20 12 Efficiency (%, Typ) 68 70 72 71 68 70 72 71 74 76 78 79 76 78 80 79 81 78 80 82 81 78 80 82 81 80 78 79 80 81 78 79 80 81 80
5
4.5-9
11
12
9-18
22
APPLICATIONS
The WRB_SP-3W & WRA_SP-3W Series are specially designed for applications where a wide range input voltage power supplies are isolated from the input power supply in a distributed power supply system on a circuit board. These products apply to: 1) Where the voltage of the input power supply is wide range (voltage range: 2:1); 2) Where isolation is necessary between input and output(isolation voltage≤ 1500VDC); 3) Where the regulation of the output voltage and the output ripple noise are demanded.
24
18-36
40
48
36-72
80
MODEL SELECTION WRB0512SP-3W
Rated Power Package Style O utput Voltage Input Voltage Product Series
*Input voltage can’t exceed this value, or will cause the permanent damage. Note: The load shouldn't be less than 10%, otherwise ripple will increase dramatically. Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
OUTPUT SPECIFICATIONS
I tem Output power P ositive voltage accuracy Negative voltage accuracy Load regulation Line regulation Temperature drift (Vout) Ripple & Noise** Switching frequency Test conditions Refer to product program Refer to recommended circuit Refer to recommended circuit From 10% to 100% load Input voltage from low to high Refer to recommended circuit 20MHz Bandwidth 100% load, nominal input voltage Min 0.3 Typ ±1 ±3 ±0.5 ±0.2 75 300 Max Units 3 W ±3 ±5 % ±1* ±0.5 ±0.03 %/ °C 150 m Vp-p KHz
MORNSUN Science & Technology co.,Ltd.
Address: 2th floor 6th building, Hangzhou Industrial District, Guangzhou, China Tel: 86-20-38601850 Fax: 86-20-38601272 http://www.mornsun-power.com
*Dual output models unbalanced load: ±5%. **Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power Converter section, application notes.
MORNSUN reserves the copyright
Specifications subject to change without notice.
WRA_SP-3W & WRB_SP-3W
A/1-2008
Page 1 of 2
COMMON SPECIFICATIONS
I tem Storage humidity Operating temperature Storage temperature Temp. rise at full load Lead temperature No-load power consumption I solation voltage I solation resistance I solation Capacitance Cooling Short circuit protection Case material MTBF W eight Tested for 1 minute and 1 mA max 1500 Test at 500VDC Input/Output Free air convection Continuous, automatic recovery Aluminium alloy 1000 15 K hours g 1000 100 1.5mm from case for 10 seconds 0.2 -40 -55 15 300 W VDC MΩ pF Test Conditions Min Typ M ax 95 85 125 °C Units %
Recommended Circuit All the WRA_SP-3W & WRB_SP-3W Series have been tested according to the following recommended t esting circuit before leaving factory (Figure 1). This series should be tested under load.
Vin
Ci n
+Vout
DC
DC
0V -Vout
GND Single Output Vin
Cin
+Vout
DC
DC
0V
GND
If
you
(Figure 1) want to further ripple, you
decrease can
the
Note: 1. All specifications measured at TA=25°C, humidity
很抱歉,暂时无法提供与“WRB1212SP-3W”相匹配的价格&库存,您可以联系我们找货
免费人工找货